Science topic

Civil Engineering Software - Science topic

Explore the latest questions and answers in Civil Engineering Software, and find Civil Engineering Software experts.
Questions related to Civil Engineering Software
  • asked a question related to Civil Engineering Software
Question
7 answers
I need help with one survey to reach 3000 people (response). I will be really thankful if anyone can reply and share this survey.
Relevant answer
Answer
I have answered
  • asked a question related to Civil Engineering Software
Question
3 answers
According to my information, the lumped mass is a diagonal mass that has six elements (u1, u2, u3, r1, r2, r3). u1, u2, and u3 have a value equal to (ml/2) while r1, r2, and r3 have a value equal to zero. In Figure (1-a), the matrix is arranged and constructed correctly, while in Figure (2-b), the matrix is unarranged and constructed differently why?
Relevant answer
Answer
Hossein Safar Yousefifard, your answer is interesting. I have the same issue with the extracted matrix. My primary concern is to find the center of rigidity since SAP2000 doesn't have this option. Is there any workaround you suggest?
Thanks in advance.
  • asked a question related to Civil Engineering Software
Question
4 answers
In his name is the judge
Hi
I think the best way to assign the nonlinear effect of steel components like beams that to model it with a plastic hinge.
So To build a nonlinear model of a one-story steel structure I use the Modified Ibarra – Krawinkler model to model my beam. In fact, I model a beam with two hing (zero length element) at the start and end and one elastic beam in the middle.
I used material developed by Lignos and Krawinkler named uniaxial material Bilin and here is more information about this material
After all, when I extract the output belonging to the stress-strain of this material under seismic loading like Kobe I get something like this diagram. (kobe0.5g) based on
"Ibarra L.F., and Krawinkler, H. (2005). “Global collapse of frame structures under seismic excitations”, Rep. No. TB 152, The John A. Blume Earthquake Engineering Center, Stanford University, Stanford, CA."
named article and this diagram (ref1) the stress-strain shows the right modeling and performance. consider that my record is near fault and the diagram of reference also belongs to near-fault loading.
If I use the 1g scale for the Kobe record I get this diagram (kobe1g) and here is the diagram of the 2g scale for the Kobe record (kobe2g) So my best shot is this when the record multiply and the ground accel become higher the material reaches the capacity of its deterioration very more quickly(In fact after a short time the strain of material switch between 1e10 an-1e10 and strain is between about -2 and 2) but it's a little non-sens for me in the other hand there is one benchmark( in the reference is named it before this benchmark is for standard loading) diagram for this material stress-strain (logos) and my diagram is different with it.
In the end here are the 1M$ questions
1- why when I give more scale to record the diagram become like that?
2- and why my diagram is different from the benchmark stress-stress of material?
Any help is greatly appreciated.
Take refuge in the right.
Relevant answer
Answer
Dear Mohammad,
Please note that pre-cap plastic deformation (rotation) capacity is relative, not absolute. It represents the distance between the yield and maximum moments. Although in the two diagrams the absolute maximums are different, the distance between the yield and maximum moments are the same.
Regarding your second question, please make sure you assigned monotonic backbone parameters with some cyclic deterioration. From the rapid in-cycle deterioration (softening) in the diagrams you have sent, I suspect you have assigned the first-cycle (cyclic) backbone parameters.
BR.
  • asked a question related to Civil Engineering Software
Question
4 answers
In his name is the judge
I want to build some parametric structures. my objects is period of first mode, eccentricity and (frequency of torsional mode/frequency of transitional mode). So I decide to use NSGAII for make my parametric structure.
Inputs of optimization are transitional mass, rotational mass, length and width of structure and objects are period of first mode and (frequency of torsional mode/frequency of transitional mode) and in each one I assume eccentricity constant.
So I think there is a problem. I think there is a relation between rotational mass and transitional mass with respect to length and width of structure and eccentricity of mass.
If my guess is true I have to remove rotational mass from my inputs and use the relation instead.
So my big question is
Is there any formula to evaluate rotational mass based on dimension, eccentricity and transitional mass in rectangular plan?
wish you best
Take refuge in the right.
Relevant answer
Answer
If your structure is an 'office' or 'hospital' type building with concrete floors, so that the floors form rigid diaphragms at each storey, mass is associated with the translational response, and mass moment of inertia (MMI) is associated with the torsional response. You need to study an appropriate text on this, or an ETABS program manual, etc. Attached are formulae for calculating the MMI for typical floor shapes, including how to allow for these shapes being offset from the overall centre of mass.
  • asked a question related to Civil Engineering Software
Question
5 answers
In his name is the judge
Hi
I'm trying to make a fuzzy controller in order to optimize my absorber performance in opensees(in python).
I use adaptive neuro-fuzzy inference system (ANFIS) toolbox in matlab to make fuzzy system as controller.
input data for fuzzy logic system are acceleration and velocity of absorber and the output data is force wich controller send it to absorber for performance improvement.
in fact i want controller learn ,based on velocity and acceleration of a point of structure, how much force need for turn structure into it's balance position.
note that quantity of force determine by fuzzy controller system and applying force part of absorbr job.
logically we have to assign come load to the point of structure wich absorber locate there and then get acceleration and velocity of absorber as input training data of fuzzy logic system.
but i realy don't know how can i do this.
note that i want to give force to structure in balance position, in the otherwise i think make train data is possible when using dynamic loading so i entirely confused here
if you have any suggestion i realy eager to hear it.
wish you best
Take refuge in the right.
Relevant answer
Answer
Mohammadhassan Eftekhar To train a fuzzy system utilizing neuro-adaptive approaches, input/output training data from experiments or simulations of the system to be modeled must be collected. In general, ANFIS training works successfully if the training data is completely reflective of the data characteristics that the trained FIS is meant to model.
  • asked a question related to Civil Engineering Software
Question
6 answers
I want to model a Dam in 8 stage.
Relevant answer
Answer
Abaqus is powerful for modeling stage construction via the model-change feature (Interaction module). However, this capability is available in Abaqus Standard only (not yet available for Abaqus Explicit).
  • asked a question related to Civil Engineering Software
Question
4 answers
hello
In order to do my thesis, I need to place the damper I developed at OpenSees on several asymmetric steel benchmarks. For this purpose, to develop asymmetric one- and nine-story structures, I decided to use the method given in the above article, but unfortunately in the article, the structures are parametric and I do not realize this.
Here are some basic questions for me.
One, how the mass and structural members of these structures are defined and modeled.
Second, how can a find period for these structures?
And finally, how is it possible to get the response of these structures under the earthquake record?
My strongest guess is that it is to define stiffness of each structural member as a coefficient of mass or vice versa.
Any help is greatly appreciated.
Take refuge in the right.
Relevant answer
Answer
In his name is the judge
thank all of you Juan Pablo Peñaloza & Kan-Jen Liu & Paul Mathew
Vizhalil my dear friends.
I think found my answer. for researching about kind of structure we use parametric structure to do complete research. for example to see affect of torsionally assymetry structures we develope parametric structures.
It means we Generate structure in 3 diffrent periods like 0.5,0.75,1 second. mass, dimension and stiffness of structure are not important in this case what is important is period only. in the second step we Generate 3 structures which have 3 diffrent torsional ratio (torsional ratio = (period of torsional mode)/(period of Transitional mode)) 0.5,1,1.5 for each single period. so totaly we build 27 diffrent structres which their elements, dimension or materials and etc are not important at all the only main things about them are periods and torsional ratio.
We call these structures parametric and we can use them for Exhaustive research about torsionally assymetry structure in our Purpose. i used parametric structures in case of see tlcgd affect on torsionally assymetry structure.
Take refuge in the right.
  • asked a question related to Civil Engineering Software
Question
4 answers
i had done some work about the debris flow through the experiment and numerical simulation using PFC3D.the particle velocity cloud figure of particle flow could't be well displayed to the reader.
Relevant answer
Answer
This is a good question.
  • asked a question related to Civil Engineering Software
Question
2 answers
i am using Abaqus CDP how can i get the parameters of Damages fc , ft and how to apply the eccentric load to a wall supported Pin-Pin ends? tq
Relevant answer
Answer
This is a good question.
  • asked a question related to Civil Engineering Software
Question
3 answers
I already have application file.
Relevant answer
Answer
This is a good question.
  • asked a question related to Civil Engineering Software
Question
2 answers
Researchers that is currently using Avizo software. 
Relevant answer
Answer
This is a good question.
  • asked a question related to Civil Engineering Software
Question
4 answers
There's a pinned, steel I-beam like IPE300, 5m lenght, 300mm height, flange 10,7mm thick and 150mm width, web 7,1mm. It's made from shell elements. I'm trying to do buckle analysis with load of 10kN/m.
First of all, I recalculated 10kN/m into kN/m² (10/0,15(width of beam's flange) ) and put on upper flange. In buckle analysis I get 1. eigenvalue = 5,07. In LTBeam I got 2,81, so I checked the reaction forces in boundary conditions. The sum of vertical forces in reaction nodes was equal to the 10kN/m load (25kN for side).
Then I put concentrated forces (corresponding to the 10kN/m) in every node over the web in upper flange. In buckle analysis I got 1. eigenvalue = 2,30. Reaction forces are OK (25kN for side).
I'm curious why there's such a big difference between those two kinds of load with equal value for beam. I made recalculation for edge load and there's almost the same result as in concentrated forces case.
Relevant answer
Answer
That is a good question.
  • asked a question related to Civil Engineering Software
Question
3 answers
Good morning,
I am trying to analyze a 2D four-level frame structure that is formed by concrete columns and concrete beams. The original building from where I obtained the frame is a university structure here in Perú. I considered the sections and reinforcements according to constrution plans.
I used user defined hinges that were created by a moment-rotation analysis considerating concrete and steel models. I consider a certain level of axial load in order to obtain moment-rotation diagrams in columns. I didn´t use any automatic hinge definition (ASCE or FEMA) because I would like to obtain results acordding to my own constituve models. I created different hinges for columns and beams and I placed them in every extreme side in columns and beam and in the middle of beams.
The seismic record is Lima 1974 earthquake and I scaled it to a 0.45g aceleration that belong to the maximun aceleration in peruvian seismic resistant norm. The original unit of the seismic record is cm/seg2. I think this is a good level of earthquake in order to generated an inelastic response in the hinges. For that reason I used a scale factor of 0.0247 that means to convert the units cm/seg2 to m/seg2 (x 0.01) and I also considered the value of 2.47 to scale the maximun aceleration of the seismic record to the value of 0.45g. At the end, the scale factor results in 0.01 x 2.47 = 0.0247.
In the nonlinear time history case I also used a initial nonlinear case in order to obtain more degradation (Gravity loads). I also defined geometric nonlinearity parameters in order to obtain more displacements.
The problem is that I didn't obtain a good strength degradation of the hinges and they seem to have a elastic degradation response. For that reason, I ask for your help because I don´t find the problem in the model definition. I check my moment-rotation diagrams and don't have any problem or error.
I would apreciated some help and I share the model definition with all the things that I defined in the analysis.
Thanks.
Relevant answer
Answer
That is a good question.
  • asked a question related to Civil Engineering Software
Question
6 answers
My model is a raft rested on group of stone column, my phases are as follows:
1: Initial phase
2: Installation (raft + stone column)
3: Surface Loading of Raft
3-1: 40% Consolidation
3-2: 70% Consolidation
3-3: 90% Consolidation
After Calculation I get the same results (Settlement & No of Days and steps of solution) for 40% Consolidation and 70% consolidation, and this does not make sense,
so please can anyone know how can I solve this problem?
* attached photos
Relevant answer
Answer
Dear Mr. Khaled,
Do you know how to plot the degree of consolidation in a profile view?
  • asked a question related to Civil Engineering Software
Question
4 answers
Hello!
I am analysing a cable stayed bridge seismic behaviour in Ansys Mechanical APDL, but I have got some problem unfortunately. I wolud like to run multiplie loadsteps in one work session. In every load step I want to prestress a pair of cables so that the other ones are stay prestress free. Every cable in the structure made of LINK 180 element. Here is the snipet of my code where I defining the loads and loadsteps and try to solve them.
!MEGTAMASZTASOK
!///////////////////////////
ALLSEL,ALL,ALL
NSEL,S,LOC,Y,15
NSEL,A,LOC,Y,-15
NSEL,R,LOC,X,0 !MEGTAMASZTAS
D,ALL,UZ,,,0
ALLSEL,ALL,ALL
NSEL,S,LOC,X,0
NSEL,R,LOC,Y,0 !SZELSARU
D,ALL,UZ,,,0,UY
ALLSEL,ALL,ALL
NSEL,S,LOC,X,144
NSEL,R,LOC,Z,-11.285
NSEL,R,LOC,Y,-23.463,23.463 !TELJES MEGTAMASZTAS PILON ALJ
D,ALL,ALL,,,0
ALLSEL,ALL,ALL
NSEL,S,LOC,X,444
NSEL,R,LOC,Z,-11.285
NSEL,R,LOC,Y,-23.463,23.463 !TELJES MEGTAMASZTAS PILON ALJ
D,ALL,ALL,,,0
ALLSEL,ALL,ALL
NSEL,S,LOC,Y,15
NSEL,A,LOC,Y,-15
NSEL,R,LOC,X,588 !MEGTAMASZTAS
D,ALL,UZ,,,0
ALLSEL,ALL,ALL
NSEL,S,LOC,X,588
NSEL,R,LOC,Y,0 !SZELSARU
D,ALL,UZ,,,0,UY
ALLSEL,ALL,ALL
NSEL,S,,,6168,6173,5 !LEKOTES
F,ALL,FZ,-4000*1000
ALLSEL,ALL,ALL
NSEL,S,,,6188,6213,25 !LEKOTES
F,ALL,FZ,-4000*1000
!TERHEK
!///////////////////////////
ACEL,,,9.81 !GRAVITACIO
!KABEL FESZITES
!///////////////////////////
*DO,I,1,2,1
ESEL,S,TYPE,,3
INISTATE,DELETE
ESEL,S,,,3733+2*I,3734+2*I,1,1 !KABEL ELEMEK
INISTATE,SET,CSYS,-2 !LOKALIS KOORDINATRENDSZER
INISTATE,SET,DTYP,STRE !FESZULTSEG
INISTATE,DEFINE,,,,,1000000000 !FESZITESI ERTEK
LSWRITE,I
*ENDDO
FINISH
!MEGOLDAS
!///////////////////////////
/SOLU
ALLSEL
ANTYPE,0 !ANALIZIS FAJTA
PSTRESS,ON
OUTRES,ALL,ALL !FESZITES BEAKCSOLASA
LSSOLVE,1,2,1
FINISH
Ansys solves the problem, but got an error wich says:
*** ERROR *** CP = 626.422 TIME= 17:49:37
LSSOLVE looping is stopped because of a solution error.
In post procesing I have some sort of result, but it has only one load step, and gives a rigidy body displacement (I added the picture as a file).
Do you have any ide what did I mess up? If I prsetess only one pair of cable, and ask Ansys for solution, it perfectly works withou any errors.
My other problem is about elemnt table results. I would like to write out the element table result into a text file, but I don't have any idea how could I extract the results with scripts.
Thank you in advice for your help,
Rafael
Relevant answer
Answer
It is a reflection of the constraints. Can you send me the file of the model to check out?
  • asked a question related to Civil Engineering Software
Question
82 answers
In your opinion which is the best software to analyse a 3D frame:
(a) STAAD
(b) ETABS
(c) ABAQUS
What are the merits of your answer?
Relevant answer
Answer
All of which have been created for a reason. It is up to you what you want to calculate? If you want to work in a finite element area, ABAQUS is a good choice. To analyze and design high-rise buildings under lateral loads, ETABS is great, and also, if you are looking for a 2D pushover analysis, SAP2000 and in case of 3D pushover analysis, PERFORM-3D are proper choices.
  • asked a question related to Civil Engineering Software
Question
4 answers
In pushover analysis,while defining lateral load pattern for there is actually two options available 1. mode 2. ACC. Mode pattern considers the pattern as the mode shape of the structure analysed. What does the 'ACC' mean? how the load is distributed along the structure?
Relevant answer
Answer
I hope this video will help you a lot.
  • asked a question related to Civil Engineering Software
Question
4 answers
How can I model a three-storey structure in opensees with viscous damper the enters harmonic force to top floor?((for obtaining stories acceleration)
Relevant answer
Answer
Dear Heydaru, there is a lot of models include in Opensees software are available and ready to run
  • asked a question related to Civil Engineering Software
Question
21 answers
The tensile damage parameter, dt is defined as the ratio of the cracking strain to the total strain. Similarly, the compressive damage parameter, dc is defined as the ratio between the inelastic strain and total strain. In that case won't the expression (4) and (2) in the attached paper always evaluates to zero?
Relevant answer
Answer
I've made a webtool that should help new users to define these properties. Please find it here:
  • asked a question related to Civil Engineering Software
Question
6 answers
I'm doing an unsteady state project on HEC-RAS, but I get an error the says time series ends before simulation time at the end.
Relevant answer
Answer
Anyone know how to solve time series data in HEC-RAS as attached file?
  • asked a question related to Civil Engineering Software
Question
4 answers
Dear all,
I am writing the Abaqus' output such as stress and strain in a text file. I need to use these as training data. However, the results are repeated and given different set of data because of the differences in the number of iteration.
In the text file I can have the number of elements, increment number and variables but I need the number of iteration as well?
Does Abaqus in Umat output give me just the last iteration?
The attached texts show the data is repeated twice for on iteration and triple for two iterations? (Number of element = 15)
Could you please advise me ?
Best regards
Relevant answer
Answer
Dear Ali
Yes, it gave you the last iteration information that has been converged in each increment.
  • asked a question related to Civil Engineering Software
Question
8 answers
I am using SWAT 2012 New Delhi conference data. when I am using HWSD (FAO) type it is showing that the raster layer hwsd.bil doesn't have attribute table just after its loading ( before defining look up table) as shown in fig 1. and when using SOIL_WATERBASE (faosol.img) it is showing that "I-Ne-3729" doesn't exist in user soil database but it exist (as shown in fig 2.). If I replace it (I-Ne-3729) with some other soil from SWAT default soil of USA, it is showing that - some of the user soil can't be detected by SWAT, should be corrected SWAT RUN.
Relevant answer
Answer
Make sure swat is accessing the correct SWAT2012.mdb database. This file should be in your ArcSWAT project folder. When you create an ArcSWAT project, before doing anything, go to "Edit SWAT Input" ---> "Database" and make sure your soil and landuse and other databases are all there and are correct.
  • asked a question related to Civil Engineering Software
Question
7 answers
I have modeled a 3story-3bay frame in Opensees that it has one vertical shear link in each story. I wanna get the deformation of the links to know their rotation, so I've used the below Recorder , but I did not get any data in my outputs.
recorder Element -file data/ele1003Defo.out -time -ele 1003 section 28 deformation;
would you please help me where is my wrong?
So Thanks,
Relevant answer
Answer
Hi @Elham Noori , it seems you are providing the section tag as input. You need to provide the integration point number at which the results are required. If you have used 5 integration points you have to replace 28 with a number between 1 and 5.
Regards
  • asked a question related to Civil Engineering Software
Question
10 answers
I want to perform analysis on a concrete beam subjected to static load at centre of beam. How can I model steel concrete interaction? How can I model a perfect bond?
  • asked a question related to Civil Engineering Software
Question
5 answers
I am trying to model Reinforced concrete column under Axial load only IN ANSYS.
when i try to model RC column both ended are fixed with axial load i got non convergence problem at early time ,
meaning if the capacity of specimen is 2400KN according to practical results i got in ansys non convergence at 300 KN only
so i think ansys stop solving when the concrete cover cracks and don't wait until the core of column crushed
i have checked the geometry and the material didn't find any things
so can you give me any guidelines or advice or files in this problem.
Relevant answer
Answer
  • asked a question related to Civil Engineering Software
Question
6 answers
I am simulating the flat slab model under cyclic loading. I am using CDPM for the material properties of the concrete. In order to define the stiffness degradation in each cycle, tension and compression recovery for concrete should be defined. Until now, I am just assuming the value and do not know how to calculate the precise value. Anyone has any idea where I can fine the articles? Some links would be very helpful.
Regards
Relevant answer
Answer
Aslani, F., Jowkarmeimandi, R. 2012. Stress-strain model for concrete under cyclic loading. Magazine of Concrete Research, 64(8): 673-685.
  • asked a question related to Civil Engineering Software
Question
3 answers
 I have this problem the following error message appeared to me
Elements to be separated by cohesive elements are of more than one stiffness number (169 and 172, perhaps more). The CZMESH command is ignored
I am trying to modeling  the debonding between concrete and CFRP using 2D analysis. in order to present the debonding I have to use the CZM with contact element. how could I solve this problem could you help me?
after generating the target element and the contact element iused the following command
TB,CZM,3,1,1,CBDD
TBDATA,1,C1,C2,C3,C4,C5,C6   ( HERE I PUT THE VALUES THAT I CALCULATED FOR (C1,C2,...)
R,1
RMODIF,1,3,-1E6
RMODIF,1,12,-1E6
CZMESH,CM_1,CM_2
after that the error message appear how could I solve this problem (the attached photograph show the model with error message. any answer ?
Relevant answer
Answer
Interesting,,
  • asked a question related to Civil Engineering Software
Question
7 answers
Bridge is of a 175m span, post-stressed cables, Software preferably in Sofistik AG, could be in Autodesk Robot 2012.
Relevant answer
Answer
Check the following reference Please.. it might's assist you in your question … Regards…
  • asked a question related to Civil Engineering Software
Question
4 answers
For Curve Segment Cable Stayed bridge. What is the design criteria for max. twisting moment to find manually as per IRC or lrfd or any other standard. or a any equation related to find twisting moment.
Relevant answer
Answer
Good question.. Please share me the best answer might you trust...
Regards…
  • asked a question related to Civil Engineering Software
Question
6 answers
Hello everyone
I am simulating the suspension bridge given on the pictures by ANSYS workbench.
However, I just add the earth gravity force(self weight ) on the structure but it has exceeded the allowable deflection in vertical direction.
So I was wondering whether the anchorages of bridge use the pull force to cancel the self weight of bridge?
I will very appreciate any replies. 
Relevant answer
Answer
Check the following reference Please.. it might's assist you in your question … Regards…
  • asked a question related to Civil Engineering Software
Question
3 answers
I'm new in Bridge Engineering
How can I modelling a steel box girder (deck) using Midas Civil engineering software?
Relevant answer
Answer
Check the following reference Please.. it might's assist you in your question … Regards…
  • asked a question related to Civil Engineering Software
Question
3 answers
for experimental analysis of scour depth at particular site, How can I proceed if I am starter in the civil engg. field ? What experiments are mandatory for this?
Relevant answer
Answer
Good question.. Please share me the best answer might you trust...
Regards…
  • asked a question related to Civil Engineering Software
Question
4 answers
I want to design the composite column in ETABS by section designer command method. After the column section made in section designer i assigned this member in building model but in after the placement the design procedure shows as the concrete frame design instead of composite column design. what should i do in this case? how can i change the design procedure?  
Relevant answer
Answer
Interesting.
  • asked a question related to Civil Engineering Software
Question
3 answers
I've modeled a simple 2 DOF structure in ETABS then manually computed the modal analysis
I used mass story and story stiffness on ETABS data table
but when i compared my manual computation eigenvalue with ETABS eigenvalue, they both not the same
i'm really sure that my manual calculation is correct, can you please help me to find the ETABS modal analysis calculation?
simple 2 DOF structure -> 2 story shear building (only Ux or Uy analysis direction activated)
I found that this only occur if i run model analysis in 3 dimension structure
i've made 2 dimension frame and run modal analysis on it, and the eigenvalue from my manual calculation with program calculation are same
Relevant answer
Answer
Share me the answer please.. Following
  • asked a question related to Civil Engineering Software
Question
4 answers
i am comparing the results of various bracing system for  industrial structure.
while i analysing the structure with X and diagonal bracing it shows less lateral deflection 7-18 mm and 4.73-8.95 mm under various seismic zone.
but in case of K bracing and V bracing it shows large value around 2000mm and lots of instability at joint how do i solve it and whats the reason.
what should i do for getting small displacement
Relevant answer
Answer
Good question.. Please share me the best answer might you trust...
Regards…
  • asked a question related to Civil Engineering Software
Question
17 answers
I have a building plan in 2d format that I want to convert into 3d, kindly suggest recent software available. 
Relevant answer
BIM (buiding information modeling) can be a solution:
-Revit
-Archicad
- VisualArq
  • asked a question related to Civil Engineering Software
Question
4 answers
steel frame design
Relevant answer
Answer
Are there any Tekla APIs for Python?
  • asked a question related to Civil Engineering Software
Question
3 answers
I am trying to model reinforced frame section in 2D using tno diana fem software. How can I define detail reinforcing of X-section in 2D model in TNO DIANA?
Relevant answer
  • asked a question related to Civil Engineering Software
Question
4 answers
hi,can anyone help me about modelling of "LSF . i am try to model a hystersis loop for a gypsum panel shear wall and use of Pinching4 Material. but i can't calibrate the parameters of this Material. can you guide me about this issue? thank
Relevant answer
Answer
please check the solved example in below link:
  • asked a question related to Civil Engineering Software
Question
6 answers
I am currently modeling a simple truss with Newmark Method (time integration method) on SAP 2000, I have read some of article about process of time integration method.
But since I try to compare the "show plot function", it has different shape with the time history input. (please take a look to the picture below)
Anyone who ever use linear time integration method specially newmark method. I hope you have time to help me.
Regards,
Ichsan
Relevant answer
Answer
Dear Bowei,
Thank for your response!
I have solved my problem..
I just change the mass source.. and the graphic shape almost same.
Best regards,
Ichsan
  • asked a question related to Civil Engineering Software
Question
3 answers
I want to know any info about undex and modeling to fem analyze 
Relevant answer
Answer
take a ref point mean of explosive location
in interaction, select the incident wave type/UNDEX and set the parameter
  • asked a question related to Civil Engineering Software
Question
61 answers
Which has better strength; circular, square, rectangular, or any other cross-section of RC columns; if all have the same area, main reinforcement, fc’, and fy ?
Relevant answer
Answer
Nice question!
I am assuming your question is to compare both columns under axial and combined loading,
Regarding the pure axial loading, I believe both are similar. However when it comes to eccentricity, the square/ rectangular is stronger.
  • asked a question related to Civil Engineering Software
Question
5 answers
Hi everybody,
I am currently trying to create a numerical model of a Bögl slab track and I was wondering which is the simplest way to simulate the rail pads between the sleepers and the rails. 
I would appreciate any kind of help, thank you.
Relevant answer
Answer
It depends on what you are trying to study, you can model the railpad in three ways:
1-as a spring-damper linear element. This is the simplest way, however this technique will give limit insight to the behaviour of the pad. For this you will need linear spring stiffness of the pad and damping.
2- you can also model the pad a solid elastic element. This give you more insight into the stress state within the pad. For this you will need pad diminsions, Young's modules and density.
3- finally you can model the pad as a solid hyperelastic element. This accounts for non-linearity in pad behaviour. However, for this you require test data to input the modelling. Please keep in mind this technique may increase your comuptational time significantly sine the stiffness of the pad will be stress dependent.
  • asked a question related to Civil Engineering Software
Question
3 answers
Dear all, 
I am trying to model pile soil interaction. I have a short rigid pile in undrained clay, I use C3D8RP for my soil and C3D8R for my pile. At this stage I used Mohr-Coulomb model. I can see that my Geostatic step gives the correct values of displacements and stresses, but when I go to the results and I run Animate Time History , I can see that the pile punches into the soil under its self weight and the geometry of the pile changes (Diameter increases) and the soil disturbance is very strange. 
Is there any way that I can model the case without having the pile sinks into the soil under its own self weight please?.
I appreciate your help , and thank you in advance.
Relevant answer
Dear Hassan,
You can try this simple SSI model construction in ABAQUS or find similar video from this link. Hope useful.
Dassekpo.
  • asked a question related to Civil Engineering Software
Question
3 answers
I want to model adobe brick as smeared cracking and mortar as zero thickness cohesive element but I dont know from where I can start. What are the data needs to be entered for smeared cracking and zero thickness cohesive element?
Relevant answer
  • asked a question related to Civil Engineering Software
Question
1 answer
I am trying to simulate 1D site response analysis and then to compare with some other software i.e openSees and DeepSoil. Unfortunately, I am new to this software and having a difficulty in understanding. If anyone has Linear, Equivalent or Non-Linear analysis file in LS-Dyna. Please share with me. 
I'm thanking you in advance
Relevant answer
Answer
I am not sure it will work with you or not but in the attached file there txt files contains response spectra 1D. Hope txt file will work with you.
regards
  • asked a question related to Civil Engineering Software
Question
7 answers
The research is the simulation of the embankment subject to the cyclic loading.
The model is  built in PLAXIS 3D. After finishing the structures stage the Volume of foundation;  soil; facing disappear in mesh stage then it can not perform the mesh on it.
Relevant answer
Answer
it looks me that while generating mesh by mistake you might have removed soil face and it generate only the structural face. hope you try again definitely it will generate soil face..follow the PLAXIS manual for the problem..
  • asked a question related to Civil Engineering Software
Question
3 answers
I’m trying to make a moment rotation hysteresis diagram for an HSS to HSS connection in ANSYS. To be able to get the hysteresis diagram, I applied a cyclic loading protocol using a remote displacement at the end of the beam, defined in several analysis steps to represent the displacement at each cycle. Knowing the displacement, it is very simple to determine the rotation of the connection. Nevertheless, I’m not sure of the best way to determine the moment at the connected column face to build the hysteresis diagram.
My question is, do you have any suggestions of a method to obtain results for moment at the column face?
Attached is a picture of the model of the connection that I am using.
Thanks in advance for any help,
Martin
Relevant answer
Answer
Engr. Pedrazzi,
Once again thank you for your answer, you have been very helpful for my work.
I was originally obtaining the moment from the force reactions since my boundary conditions simulate a pinned support, which I believe is similar concept to your suggestion of obtaining the moment reactions.
Nevertheless, using surface as the moment geometry sounds very interesting since I can get the moment values that I’m actually getting at the connected column face, which is the result I’m interested in. I'll let you know when i get new results. 
Once again thanks for your insight. Best regards,
Martin
  • asked a question related to Civil Engineering Software
Question
14 answers
Hey everyone, 
I am now creating a 2D bridge model for the following concrete bridge. It has two spans. The bridge superstructure is basically a concrete slab, with the middle fixed by a shear wall and the two supports built in the abutments. 
My aim is to obtain the natural frequency for this bridge; however, I am not sure what boundary or constraints should I put on the bridge supports. Can someone help with this? 
Relevant answer
Answer
I think this is a concrete box culvert that is probably better modeled by a rigid frame analysis.  The walls are as important as the slab.
  • asked a question related to Civil Engineering Software
Question
1 answer
Currently I am designing a building (width=35 m) over 2 layers of very compressible soils with 35 and 10 m thick and Cc arround 5. Below them is a very stiff soil.
I decided to improve those layers with rigid inclusions, but I do not know how can I introduce the influence of the rigid inclussions into the consolidation (settlement) analysis.
Can anybody help me with this?
Note: Maybe the obvious solution could be to have a deep foundation to the stiff layef, but it is not feasible beccause of a regional settlement could cause an apparent emersion. 
Relevant answer
Answer
Jose, I spent the last two years on the NAICM airport with Parsons, including reviewing the field tests of about 10 different methods for improving the soil for the runway and tower loads.  We did a test with and without inclusions.  In every case, the installation of  inclusions (concrete piles in predrilled holes) disturbed the soil and increased its compressibility by disturbing the e-log-p curve.  See attached pptx file.  Basically, you nearly doubled the settlement with some benefit of upper layer rigidity, but it was hard to tell. 
Greg McNulty
  • asked a question related to Civil Engineering Software
Question
10 answers
I have completed BE in civil engineer and a native of Nepal. And I want to do research regarding the buildings damaged in the Nepal Earthquake 2015. I have the knowledge but don't know how to start one
Relevant answer
Answer
- Site Effects and Associated Structural Damage Analysis
- Earthquake Geotechnical "studying correlation between uncorrected standard penetration resistance (N) and shear wave velocity" and liquefaction studies.
- seismic vulnerability of highway bridges.
- Seismic Performance of Sites
- Structural damage analysis
- ground motion attenuation simulation
  • asked a question related to Civil Engineering Software
Question
3 answers
Hello everybody
I'm using opensees to simulate SSI problems. I modeled the problem using direct method and now I want to know how can I connect my structure to the soil media. I used a rigid beam as foundation (foundation was not designed) and connect it to soil surface without any special elements ( equalDOF was used to constrain the beam and soil movements in X and Y directions). But drift results shows the rocking doesn't happen in correct way. I need an idea to connect soil and structure.
thank you
Relevant answer
Answer
You should look into the work of Gazetas on foundation impedance. His works sometimes in mid 80s to 90s on dynamic impedance may be may be useful. Also see the guideline in the text book of J. E. Bowles. 
You have to really use zero length spring with appropriate characteristics (available in the works cited) 
  • asked a question related to Civil Engineering Software
Question
8 answers
I have modeled a mortar layer sandwich between two single adobe brick. I have given an contact interaction between brick and mortar. I have applied compressive stress of 5 N/mm2 on top of one brick and given pinned condition Ux=Uy=Uz=0 on the base of the other brick. The model run fine with 5 N/mm2 pressure, but when I increase it to 6 N/mm2, the solution does not converge. The model is shown in figure. The step time is as:
Time period 100
Max no. of increment 1000
Initial INcrement size 0.0005
Minimum 1E-300
Max 100
Relevant answer
Answer
Dear Sunesh,
Question: Thanks JD Nzabonimpa for answering, but can you tell me how can I check if there is any slippage between the layer? 
Answer:
First attempt, you have to locate the possible error location by checking job diagnosis. And also you should consider Mr. Sunil Raiyani's recommendations. if you cannot locate the error, try to increase the viscosity parameter or use any of stabilization methods such as damping. but damping can overestimate your response of your structure. make sure to check your results whether they make sense or not. 
  • asked a question related to Civil Engineering Software
Question
17 answers
Hello everyone, I am designing a 7-story steel building using STAAD Pro software. I made it and when I saw it in render view, it showed intermixed I sections at column beam joints. What type of joint is that?
Relevant answer
Answer
Semi rigid joint can be used with relative rigidity.
  • asked a question related to Civil Engineering Software
Question
3 answers
I have modeled a bridge using the bridge modeler , and i want to add rollers in mid span to simulate the bent behavior because i do not have the exact dimensions and properties of the bents .   
Relevant answer
Answer
Dear Abbas AbdulMajeed
Sorry, I sent you that message by mistake. 
In regards to your question, I wouldn't know, I haven't worked that way before...
Regards.  
  • asked a question related to Civil Engineering Software
Question
5 answers
Civil engineers build the 15000 ton and 200m long bridge by and parallel to the existing tracks. When completed, rotate the bridge some degrees to make a seamless connection with the rest of the viaducts&.
Relevant answer
Answer
Even the road connected with each village well built under national standard. Very impressive indeed.
  • asked a question related to Civil Engineering Software
Question
2 answers
Dear all,
I just have architecture drawing of double-deck circle tunnel. Anyone can help me about structure drawing. I want to know their reinforcement, just same shape, dont need identical size.
Thank in advance!
Relevant answer
Answer
 Dear H. Süleyman Gökçe,
Thank you so much for your help. You dont have any structure drawing for these above shape.
  • asked a question related to Civil Engineering Software
Question
2 answers
Hello,
Eurocode 2, 7.3.4 (3):
"In situations where bonded reinforcement is fixed at reasonably close centres within the tension zone (spacing <= 5(c + Φ/2)), the maxiumum final crack spacing may be calculated from expression (7.11)"
srmax = k3 c + k1 k2 k4 Φ / ρpeff          (7.11)
and 
"Where the spacing of the bonded reinforcement exceeds 5(c + Φ/2) or where there is no bonded reinforcement within the tension zone, an upper bound to the crack width may be found by assuming a maxiumum crack spacing srmax = 1,3(h - x)"
where x is the compression zone in pahse 2.
And there is my question:
In members under uniaxial tension there is no compression zone (x = 0). Does that mean, that for such kind of elements a maximum crack spacing is equal to      srmax = 1,3 h?
Or maby this rule applies only for members with existing compression zone? If yes, than what is the upper limit for crack spacing for members subjected to tension?
Best regards,
Bartosz Grzeszykowski
Relevant answer
Answer
Hello Bartosz,
There is a paper that deals specifically with this topic. I hope it does answer your question:
Best wishes
  • asked a question related to Civil Engineering Software
Question
9 answers
Dear all, My model is a raft rested on number of piles, the piles are soil volumes.
The question now for plaxis 3D users:
How can I improve the mesh quality ? should I local refine the mesh for the volume containing the raft and piles? and what value to put it in Fineness factor? and what will be the global mesh density ?
Thanks in Advance
Relevant answer
Answer
Dear Dr.Elmeligi,
it is better to do trial analysis with increasing mesh dimensions and mesh density.. based on the analysis use best fit mesh and density for all parametric study. i am sure you will get better accuracy by doing this kind analysis. 
  • asked a question related to Civil Engineering Software
Question
5 answers
I am having trouble finding information on the use of a 3D IFC file within a building automation program, there seems to be no program that can interrogate a 3D file. 
Relevant answer
Answer
Thanks peter, I would love to read these papers
  • asked a question related to Civil Engineering Software
Question
4 answers
- Slip Failure line
Relevant answer
Answer
Okay Carlos, Awais and Munaf will try plaxis thank you so much.
  • asked a question related to Civil Engineering Software
Question
2 answers
Just as the question.
I've got a detailed and systematical introduction on numerical model of the soil-pile intercation on a sesimic load in the dissertation from the attached link. In figure 3.11 and 3.22 (the atteach picture), page 72, it is reported that real part of the impedance function is obtained from FEA,here Abaqus.
But anyone can tell me how to work it out?
can the analysis be implemented in universal step?
Is this method suitable to a harmonic load uniformly acted at the pile top?
Relevant answer
Answer
actually, it is dynamic stiffness. Kd=F(w)/U(w),w  denotes frequency
  • asked a question related to Civil Engineering Software
Question
8 answers
Dear researchers,
Do you know how I can model TNT blast loading at ground level in Abaqus? 
I'm modelling metro tunnel in Abaqus to study blast loading effect.
Relevant answer
Answer
There are three paths that you can follow in order to simulate blast actions.
1. Use the empirical model CONWEP (it's implemented in ABAQUS) in a FEA. You would need to define the equivalent TNT mass of explosive, the source point (i.e. where the explosive is located), and the solid surfaces on which the wave font impinges.
2. CEL (Coupled-Eulerian-Lagrangian) simulation. You need to model the eulerian volume of air and explosive, as Reza Saidafkan suggested. So it would be computationally and time expensive, e.g. you need to validate not only the solid "structures" but also the eulerian domain. On the other side, you can take into account for "every" kind of reflection, that would be quite significant in an underground scenario of the kind you're investigating. (if you have time, I suggest you to read "A study on the simulation of blast actions on a monument structure" fom Vannucci et al. it's a state of the art of the different approaches to simulate blast actions);
3. You can simulate the scenario of an explosion through a pressure impulse inside a fluid domain (the air) with a CFD simulation, and then "export" the pressure history acting on the solid surfaces on a FEM analysis, and running a simple explicit FE analysis. 
Good luck.
  • asked a question related to Civil Engineering Software
Question
2 answers
_
Relevant answer
  • asked a question related to Civil Engineering Software
Question
1 answer
I need to perform a Time-History Analysis on a building frame embedded in soil using LUSAS. It is a Dynamic SSI Problem, I have tried to perform the analysis by deconvoluting the Earthquake Data of Response Spectra (IS: 1893-2002) . Deconvolution is done using "STRATA" and "DEEP SOIL" (Which appears to be correct) but the problem is that after applying the deconvoluted data at the soil support (fixed in all translations at bottom and fixed in x and z in lateral direction) and recording Secondary Response Spectra at the soil top. the recorded Secondary Spectra is very high when compared to the Target Spectra that I have considered (IS: 1893-2002).
I have come through the topic of Bicanic Bounday Condition used in LUSAS but how to use it and how the load is applied and results are processed??
Relevant answer
Answer
Hi Ramesh,
have you tried to contact LUSAS support? They are very good and helpful.
I guess your issue has to do - primarily - with boundary conditions. You will definitely have to assign viscous boundaries to absorb some of the energy introduced into the system through the time-history base excitation (Rock Outcrop Motion).
Regards, Gian
  • asked a question related to Civil Engineering Software
Question
10 answers
I modelled a helical pile (with a mass at the head) installed in dry sand undergoing seismic shaking at the base. I am trying to mimic a full-scale test we performed in a shaking table. I am using ABAQUS.
My modelling steps are as follows:
Step1: Initial conditions which consists of applying fixation at the base and lateral sides of the model. I also fixed the empty void in the soil (Where the soil will be placed, I know this does not include the effect of driving the pile). I applied the initial state of stresses using the predefined field in abaqus.
Step2: Geostatic step. I applied gravity loading on all the soil. At the end of this step, I checked the stress states with depth and they are matching my initial calculations and all deformations are at of the order of 10^-7. (should they be smaller?)
Step3: Removed fixations at the void inside and activated the interaction between the pile and soil. Also applied the gravity load of the pile so that it will settle slightly in the soil. Checked stresses here and displacements and they look okay.
Step4: Applied the time history of my earthquake at the base. At the first 3 seconds during shaking the soil didnt show any settling, however during the strong shaking the soil starts to settle and reaches 0.5m displacement downwards at the surface. (look at the attached images)
I cannot think of any reason causing this. Your help is greatly appreciated!
Attached are the input file used for the analysis (took about 5 days to run) and several screenshots of the deformations during the shaking.
Also attached several videos of the run in difference scaling factors.
Relevant answer
Answer
I am not an expert in the type of model you are running here, but in my experience anytime I have conducted models of soil, geologic, or hydrogeologic systems, I have found it best to extend my boundary conditions to a point well beyond the zone of influence of the specific area I am evaluating.  From the video representation, I note that your zone of influence appears to extend very close to, or even beyond, your modeled boundaries.  If that is true of your actual model, I suggest you extend your boundary conditions further away from your study area.  That may not resolve your problem, but it will at least eliminate the potential for the boundary conditions to heavily impact your results.
The pattern illustrated by your model output certainly suggests that the soils around and below your pile are consolidating during the shaking.  If your model does not allow for the soils to consolidate, perhaps you are loosing soil volume across the boundaries. 
  • asked a question related to Civil Engineering Software
Question
2 answers
I have modelled masonry building in abaqus using homogenisation technique but i m getting some errors in analysis so now i want to model  masonry building by modelling separate brick and mortar interface so i want to know the procedure for modelling brick and mortar interface and cohesive elements,which type of element should i select to model separate mortar and brick.
I will be be grateful 
Thank you in advance
Relevant answer
Answer
okay sir thank you very much
  • asked a question related to Civil Engineering Software
Question
12 answers
Dear All,
I want to calculate the minimum distance between randomly distributed small squares as shown in the attachment. The length of the small squares is 0.016667 and the length of the total length is 1. Right now, I have the data of the centers of the small squares. I want to find out the minimum distance between these small squares.
Any suggestion would be appreciated.
Thank you.
Best Regards,
Bill
Relevant answer
Answer
Thanks Dr Vagelis Plevris for breif answer.
  • asked a question related to Civil Engineering Software
Question
7 answers
Dear all,
I am going to model ground water level falling in order to determine soil layer settlement.
I would be so grateful if anyone could help me.
Relevant answer
Answer
this refrence will help you
"Applied Soil Mechanics with ABAQUS Applications"
  • asked a question related to Civil Engineering Software
Question
8 answers
I need to study the effect of stiffness contribution from reinforcement and get load-displacement curve considering interaction of reinforced structures/composite structures. Since I'm dealing with large infrastructures (in my case bridges), what would be a user friendly (not necessarily complicated) finite element software for modelling such responses in large structures?  
My available options (those I have the license) are Ansys, Abaqus and Ls-Dyna
Thanks heaps, 
Relevant answer
Answer
i think ABAQUS is the most helpful one..regards
  • asked a question related to Civil Engineering Software
Question
3 answers
Dear Researchers, 
I modeled an RC wall that is subjected to lateral blast pressures using surface to surface contact, where a finite thin part of the underlying soil modeled as an elastic material with only 50mm thick. The bottom surface of that part constrained from movement in all directions, and upper surface connected to the bottom of wall base using surface-to-surface contact using a high coefficient of friction equals to 0.8. After the solution of the dynamic explicit problem, it is found that the wall is moving (slide and overturn) without stoppage till the end of step time! even when subjected to very low levels of loads? When the step time increased, the wall still moves till the end of extended time. I'm expecting that wall shall move certain distance then stop. Is the type of contact i'm using suitable? and how to model such contact by another ways?
Kindly help
Relevant answer
Answer
I agree with Djamel Boutagouga
  • asked a question related to Civil Engineering Software
Question
9 answers
I am working on SAP 2000 for project purposes. I am facing problem while constructing a dome structure. I know to construct it using shell command (Menu>File>New Model>Shell) instead of whole shell, I want a dome framed structure. 
Is there any way to work it out? 
Relevant answer
how are you want this please give more details about what you want to do
  • asked a question related to Civil Engineering Software
Question
14 answers
I am trying to simulate a concrete bridge under seismic loadings. The mentioned bridge have three spans with the length 28 meters. A nonlinear time-history analysis is performed.
This is the wrong massage:
WARNING NewtonRaphson::solvesolveCurrentStep<> -the Integrator failed in update<>
DirectIntegrationAnalysis::analyze<> - the Algorithm failed at time 3.29
OpenSees > analize failed, returned: -3 error flag
WARNING - ForceBeamColumn3d::update - failed to get compatible element forces & deformations for element: 23<dW: << 15307.5, dW0: 43318>
Domain::update - domain failed in update
Newmark::update<> - failed to update the domain
WARNING NewtonRaphson::solvesolveCurrentStep<> -the Integrator failed in update<>
DirectIntegrationAnalysis::analyze<> - the Algorithm failed at time 3.31
OpenSees > analize failed, returned: -3 error flag
WARNING: CTestEnergyIncr::test<> - failed to converge
after: 25 iterations
AcceleratedNewton::solveCurrentStep<> -The ConvergenceTest object failed in test <>
DirectIntegrationAnalysis::analyze<> - the Algorithm failed at time 3.31
OpenSees > analize failed, returned: -3 error flag
CTestEnergyIncr::test<> - iteration: 68 last EnergyIncr: 8.74275e-013 <max: 1e-012>
WARNING - ForceBeamColumn3d::update - failed to get compatible element forces & deformations for element: 32<dW: << 610.496, dW0: 25439.1>
how can i solve it? Thanks
Relevant answer
Answer
Hi,
In my opinion you shoud use OpenSees forum for your questions. In any case, let me try to help you based on my experience:
1. Increasing the integration section number does not increase the speed of convergence. It increases the accuracy and likely to decrease the convergence. I usually use 5 integration sections in forced based elements.
2. Too strict tolerance values may lead to convergence difficulties. On the other hand, too loose ones may not be enough to let the model behave correctly. Tolerence is not a definitive value, it depends on the type of convergence check and your model. Usually, (at least for me) tol=1e-6 to 1e-5 are good values for NormDispIncr. On the other hand, energy and unbalanced load criteria are also good, but may lead to convergence difficulties in the models having exceptionally stiff elements.
3. Decreasing dt usually works in slowly converging models.
4. Increase the number of iterations as max as possible. What I use is max 1000, if it takes more than 1000 iterations, the model is likely to be ill conditioned.
5. There is one more control in fiber section forced based elements which is the number of iterations carried out at integration sections, it could be invoked as "-iter":
i.e. element nonlinearBeamColumn 160 88 105 5 996 19 -iter $niter $tol;
default value of niter is 10, where as for tol, it is 1e-12, in my opinion one should not change the default value of tol. But especially for short length forced based elements, you may try to increase niter.
Apart from those, there are many other parameters controlling convergence. My advice would be first run the model with linear properties, to at least rule out any problem emerging from nonlinear response.
Again, those are only my opinions. You should really discuss this in OpenSees forum.
  • asked a question related to Civil Engineering Software
Question
10 answers
Both AASHTO and ACI codes not refer to this case.
Relevant answer
Answer
For external prestressing tendon there is no strain compatibility with concrete just at the anchorage zones. Accordingly for time dependent losses we can consider the strain history of the sections at anchorages to evaluate the creep and shrinkage losses with some approximation.
For relaxation losses there no difference between the bonded and unbonded tendon in behavior.
For time independent losses as anchorage setting and friction and others we can follow the same methodology which stated in ACI or AASHTO codes.
  • asked a question related to Civil Engineering Software
Question
19 answers
Hello. I am a beginner in this field.
I want to calculate thermoelectric properties with BoltzTraP. I've finished setup of BoltzTraP and ASE and I've run examples. But I have a problem with changing VASP outputs to BoltzTraP inputs using python code that is supported from the developers. Please check the problem below. 
[vasp2bolt]
1 from ase import io
2 from ase.lattice.spacegroup import Spacegroup
3 import vasp2boltz
4
5 ao = io.read('POSCAR')
6
7 sg = Spacegroup(225)
8 ao.info = {'spacegroup': sg, 'unit_cell': 'conventional'}
9
10 foundnelect = False
11 try:
12 for line in open('OUTCAR', 'r'):
13 if 'NELECT' in line:
14 nelect = float(line.split()[2])
15 foundnelect = True
16 except:
17 pass
18 if not foundnelect:
19 print 'Number of electrons not found. Please set the number manually in hte.intrans.'
20 nelect = 1.0
21
22 bs = vasp2boltz.get_vasp_bandstructure()
23 vasp2boltz.write_bandstructure_boltztrap(bs)
24 vasp2boltz.write_structure_boltztrap(ao)
25 vasp2boltz.write_intrans_boltztrap(n_electrons = nelect)
-------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------
[error message]
***************
None
Traceback (most recent call last):
File "pbte64.py", line 31, in <module>
vasp2boltz.write_structure_boltztrap(ao)
File "/home/cgr/pbte64/BT/vasp2boltz.py", line 166, in write_structure_boltztrap
krot=get_kspace_operations(ao)
File "/home/cgr/pbte64/BT/vasp2boltz.py", line 289, in get_kspace_operations
if ('spacegroup' in ao.info) and (ao.info['spacegroup']!=None):
File "/APP/python/lib/python2.7/site-packages/ase/lattice/spacegroup/spacegroup.py", line 189, in __cmp__
AttributeError: 'NoneType' object has no attribute 'no'
-------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------
I know it's a computational problem. But here is the only website that I can ask online.
I would be grateful if someone helps me. Thank you :)
Relevant answer
Answer
I would recommend to use the latest version of vaspkit to generate the input files required for BoltzTrap code. 
  • asked a question related to Civil Engineering Software
Question
7 answers
I am modeling horizontal shear between two concrete blocks (no studs) in SAP2000.
How to model horizontal shear using links? I can't input the value for cohesion and friction of concrete, only a stiffness option is given.
Which link type should I use for partially composite/ or fully composite action? Linear, Multi linear Elastic, friction isolator?
Is there any other way to model horizontal concrete shear in SAP 2000?
Relevant answer
Respected Anna Porras mam,
The field approached by you is very interesting and also vast, so more research can be done in this regard. It's very interesting topic. The following article link may help you for your kind information.
A link object connects two joints, i and j, separated by length L, such that specialized structural behavior may be modeled. Linear, nonlinear, and frequency-dependent properties may be assigned to each of the six deformational degrees-of-freedom (DOF) which are internal to a link, including axial, shear, torsion, and pure bending. Internal deformation is then calculated from joint j displacement relative to joint i, where i may be grounded to simulate a support point. To utilize nonlinear and frequency-dependent properties, corresponding analysis cases must be defined and run.
Link force-deformation (F-D) relationships may be specified for each of the 6-DOF to simulate:
-- Multi-linear springs (uniaxial elasticity)
-- Wen behavior (uniaxial plasticity)
-- Kinematic, Takeda, and pivot hysteretic behavior (multi-linear uniaxial plasticity)
-- Gap (compression-only) and hook (tension-only) elements
-- Isolation devices (biaxial-plasticity and friction-pendulum isolators with optional uplift)
-- Viscoelastic damping is specified in Force/Velocity units
All shear deformation is assumed to occur within a shear spring. Shear-spring location may be specified in terms of distance from joint j, where dj2 is the major-axis shear-spring location, and dj3, the minor-axis. As such, dj2 represents the location for 1-2 plane shearing and 1-3 plane bending, while dj3 is the reverse. Either translation or rotation may induce shear deformation. Each of the six springs and hinges which correlate with internal link deformation may actually be several coincident components which form a system of springs and dashpots. F-D relationships within a single DOF, or among multiple DOF, may be coupled or independent.
Each F-D relationship is defined within a local coordinate system which is specific to that link. Links may be of zero length, as is the case with links grounded at support points. For dynamic analysis, numerical solution requires that mass m, and mass moments of inertia mr1, mr2, and mr3, be assigned to a link such that response captures translational and rotational inertia. Half of each of these values will be assigned to each joint within a link. Internal deformation and internal forces are then reported as output local to each joint. Additional information is available in the CSI Analysis Reference Manual (The Link/Support Element Basic, page 229) and (The Link/Support Element Advanced, page 253).
  • asked a question related to Civil Engineering Software
Question
15 answers
Hi all,
Is there anyway to carry out POA (nonlinear static analysis) in SAP2000 for shell elements? I know the procedure for frame elements but what about for case of shell elements such as slab of bridge. For example, if I want to load to failure the bridge deck that is made of shell elements, how may I have the ultimate load-displacement curve?
Also:
-Do we need to have nonlinear static dead load case prior to running pushover load case? If yes, then we need to change the mass source as well?
-Is the effect of reinforcement modelled in section designer considered for pushover?
regards
Relevant answer
Answer
Arash,
I cannot see your answer.
  • asked a question related to Civil Engineering Software
Question
4 answers
Hi,
I'm not familiar with "OpenSees" software and I've been using Matlab Simulink tool box  to model the semi-active control system to seismic protection of buildings.
Now, I'm interested to utilize OpenSees to do my works. However, I don't know if it is possible to do that (modeling and simulating active control system in OpenSees ).
If anyone has any experience in this field, please help me.
Thank you.
Relevant answer
Answer
OpenSees is open-source. The open-source movement allows researchers and users to build upon each others accomplishments using OpenSees as community-based software. So you should know C# (compiler).
  • asked a question related to Civil Engineering Software
Question
10 answers
if these shapes have been considered with mat 159 concrete , the validation is correct in your point of view?  because cracked locations is same.
of course these shapes are for other sample with lower impact speed .
Relevant answer
Answer
I think your problem comes from the input parameters for material model. You should check if all input parameters are appropriate or not. Why dont you try with MAT084?
  • asked a question related to Civil Engineering Software
Question
6 answers
I want to try out numerical modelling of helical soil nails.
Relevant answer
Answer
hello dear Saurabh
i have a paper in this area and when we modeled the helical piles in 2D the results was not good and we had to modeled it in 3D abaqus
because some loading type have not good result and matching with real results
  • asked a question related to Civil Engineering Software
Question
4 answers
I modeled slab using thin shell elements and I applied slab load as area load to shell element.
Relevant answer
Answer
Since you say that the problem is in modal analysis, I presume that the load is distributed to the beams as expected for vertical loads.
As others have stated, most programs allow you to turn the loads you have applied into masses. Do so for the permanent loads and the percentage of the live loads that correspond to the seismic combinations. Be careful about the self mass of the frame, as most programs will calculate it based on the material you have, If this is the case do not include the load corresponding to the self-weight of the frame into the mass conversion.
Secondly, if it is justified by the type of structure you have, be sure to define a diaphragm on each level, in order to model the in-plane stiffness of the slab. This should distribute the seismic force to all your columns, braces or whatever you have for lateral stiffness.
I hope it helps.
  • asked a question related to Civil Engineering Software
Question
5 answers
Is there any similar expression to measure percentage of C-S-H in hardened cement paste like that in case of CH and CaCO3 by TGA.
Relevant answer
Answer
Dear Souradeep Gupta,
I don't think its possible to quantify C-S-H by TGA, because the temperature zone where C-S-H dehydrates also corresponds to the dehydratino of other phases (gypsum, ettringite and AFm phases).
An excellent reference on this subject in indicated below:
B. Lothenbach, P. Durdzinski, K.D.E. Weerdt, Thermogravimetric analysis, in: A Pract. Guid. to Microstruct. Anal. Cem. Mater., CRC Press, 2015: pp. 177-212. doi:doi:10.1201/b19074-6.
Best regards, Renan.
  • asked a question related to Civil Engineering Software
Question
6 answers
I am modeling a concrete cylinder in abaqus which is under cyclic loads,I used concrete damage model(CDP) to simulate this. the problem is that cycles dont stop and continuously increase. how the sample fails in this case? what is the failure criteria for CDP?
Relevant answer
Answer
The concrete damage plasticity model in Abaqus cannot predict failure. Cracking (tension) and crushing (compression) in concrete are represented by increasing values of the hardening (softening) variables. These variables control the evolution of the yield surface and the degradation of the elastic stiffness. The extent of damage can be tracked using the damage variables. Failure of a structure modeled using CDP in finite element model must be defined by the user based on the state of damage determined in the analysis. The following papers provide more information on the use of the CDP for modeling concrete structures:
I hope this helps you.
  • asked a question related to Civil Engineering Software
Question
16 answers
As far as I know,  the only way to get pore pressure and stress data is graphs in FLAC, that is hard to exploit of number then bringing them to Excel. 
Relevant answer
Answer
Try this example code. You will see the two columns dumped in your console. Yes, you should define fish functions to obtain axial strain (ev below) and deviator stress (s1_s3 below). 
config axi
grid 5 10
gen 0,0 0,0.038 0.019,0.038 0.019,0
m m
prop den 1800
fix y j=1
fix x i=1
ini sxx 100e3 syy 100e3 szz 100e3
apply press 100e3 i=6
apply yv=-3e-7 j=11
prop coh 2.25e3 fri 33 bulk 1e8 shea 0.3e8
def s1_s3
sum=0
loop i(1,igp)
sum=sum+yforce(i,jgp)
end_loop
sigmav=sum/(x(igp,jgp)-x(1,jgp))
s1_s3=sigmav-100e3
end
def ev
ev=(-ydisp(1,11))/(y(1,11)-y(1,1))
end
hist nstep 100
his s1_s3
his ev
step 10000
his dump 1 vs 2
  • asked a question related to Civil Engineering Software
Question
9 answers
Hi All,
I have a question regarding modal analysis on Abaqus. I am using untis of kg, N, m s(seconds). in my model. When I conduct the analysis, I get the natural frequency for many modes. Are these frequencies in rads-1 or Hz?
I have looked at the manual of Abaqus, but I can not find an answer for this. 
Thanks and Regards,
Dimuth
Relevant answer
Answer
Hello. I confirm, it is in Hertz. My advice : run a quick simple case (cantilever beam) and do a sanity check with the analytical equation.
  • asked a question related to Civil Engineering Software
Question
6 answers
Would you please introduce some basic papers in field of numerical simulation of tunnels in FEM, which contains the appropriate element type, constitutive model and important points about construction steps?
Relevant answer
Answer
Dear Mr. Madadi,
here are some publication on this topic:
Lisjak, A.; Tatone, B. S. A.; Mahabadi, O. K.; Grasselli, G.; Marschall, P.; Lanyon, G. W.; La Vaissière, R. de; Shao, H.; Leung, H.; Nussbaum, C.: Hybrid Finite-Discrete Element Simulation of the EDZ Formation and Mechanical Sealing Process Around a Microtunnel in Opalinus Clay
Franciss, F. O.: Weak rock tunneling - A simplified analytical simulation, a PC-based model and design charts for engineering practice
Kamemura, K.; Kimura, H.: A numerical analysis of tunnelling in soft rocks
Zhao, K.; Bonini, M.; Debernardi, D.; Janutolo, M.; Barla, G.; Chen, G.: Computational modelling of the mechanised excavation of deep tunnels in weak rock
Comodromos, E. M.: Numerical method for tunnelling in hard soils and soft rocks
Hoek, E.: Rock-support interaction analysis for tunnels in weak rock masses
  • asked a question related to Civil Engineering Software
Question
6 answers
Hi all
I'm trying to perform a Harmonic analysis of a beam in Ansys APDL. I want to run a lot of simulation, so I would like to solve the model using the modal superposition method. This method gives me only the values on the natural frequencies. Are there any method to extrapolate the natural frequency data to the rest of the frequency for a given range of frequencies??
Kind regards,
German Martinez
Relevant answer
Answer
Dear Germán,
     I faced this kind of problem once. It follows an input list developed in ANSYS release 11.0. I hope it can help you.
Regards,
Carlos
/PREP7
!Material: steel
UIMP,1,EX, , ,2.05e11,
UIMP,1,DENS, , ,7890,
UIMP,1,ALPX, , , ,
UIMP,1,REFT, , , ,
UIMP,1,NUXY, , , ,
UIMP,1,PRXY, , ,0.3,
ET,1,SOLID45
BLOCK,0,0.1,0,0.05,0,0.4,
vatt,1,1,1
ESIZE,0.025,0,
vmesh,all
allsel
nsel,s,loc,z,0
d,all,ux,0
d,all,uy,0
d,all,uz,0
allsel
nummrg,node,1e-6,
numcmp,node
numcmp,elem
FINISH
/SOL
nmodes=20 !Calculate the first 20 modes
ANTYPE,2
MODOPT,LANB,nmodes
MXPAND,nmodes, , ,1
LUMPM,1
PSTRES,0
MODOPT,LANB,nmodes,1,10000, ,OFF
solve
FINISH
/SOLU
ANTYPE,HARMIC ! Harmonic analysis
HROPT,MSUP,nmodes,1,, ! Mode superposition method; number of modes to use
HROUT,ON,
nsel,s,loc,z,0.4
f,all,fx,1
allsel
KBC,1
freq_i=1 !Initial frequency
freq_f=4001 !Final frequency
nfreqs=1000 !Number of frequency points
HARFRQ,freq_i,freq_f,
NSUBST,nfreqs
DMPRAT,0.02 ! Damping ratio
outres,all,all
SOLVE
save
FINISH
/POST26
FILE,file,RFRQ ! File where the results are read. Do not forget to write the right name of the file!
/OUTPUT,C:\Users\Carlos\help_research_gate,,
NSOL,2,54,U,X,node54_midlle
NSOL,3,21,U,X,node21_tip_corner
!Lista as variáveis
PRVAR,2,3,,,
/GROPT,LOGY,ON
PLCPLX,0 !Magnitude plot
/GRID,1 ! TURN GRID ON
/AXLAB,X,Frequency [Hz] ! X-AXIS LABEL
/AXLAB,Y,Displacements [m] ! Y-AXIS LABEL
PLVAR,2,3,,,, , , , , ,
NSOL,2,54,U,X,node54_midlle
NSOL,3,21,U,X,node21_tip_corner
PRVAR,2,3,,,, , , , , ,
  • asked a question related to Civil Engineering Software
Question
11 answers
MINIMUM COLUMN SIZE ACI 318
Relevant answer
Answer
I don't think there is a limitation on the size of columns, as this is controlled by many factors, like:
1- Concrete clear cover to the reinforcement (ties) > 38 mm,
2- Clear spacing between main bars, which should be more than;
    i. 40 mm,
   ii. 1.5 bar diameter,
 iii.  4/3 Max. Aggregate size.
3- Least dimension of the column should be equal to or greater than 16 main bar                diameter.
4- Least dimension of the column should be equal to or greater than 48 tie diameter.
5- Least dimension of the column should be equal to or greater than the tie spacing.
6- Strength requirements.
All these are are indirect limitations.
  • asked a question related to Civil Engineering Software
Question
4 answers
I am doing the postbuckling analysis of composite plates using ABAQUS.  I have made plate from shell element and have assigned the composite layup of four layers to the plate. I want to provide the material non-linearity in the plate, i.e., upgradation (or modificaion) of stiffness when stresses in layers exceeds the strength of plate. Is there any possibility to write a code in MATLAB which include strength and stiffnesses of plate and the link this code with ABAQUS (Like in FORTRAN)?
Relevant answer
Answer
simplest way is to store your results in excel file from where MATLAB can read the because perform operation the the respected values more over the produced results can also be stored to the same 
  • asked a question related to Civil Engineering Software
Question
3 answers
Hi,
I have a query regarding postbuckling analysis of plates(perfect). I am writing a matlab code but I am unable to find the mistake in my program.
I would like to brief of up you the method so that you can inform me if there is anything wrong in my understanding.
After linear analysis, I used the buckling load for running linear stress analysis and calculated the geometric stiffness matrix. Then secant stiffness matrix is calculated and solved the eigen value problem.
And also for simplysupported boundaries, in linear stress analysis considering 2 degrees of freedom (u,v), how is restraints applied?
Also you can share some publications or books if you think can help me.
Relevant answer
Answer
when u will ti work in buckling  of plate- the problem is a three dim not two.
u must used the plane stress or strain elasticity..... and used Von-karman government equation...
  • asked a question related to Civil Engineering Software
Question
13 answers
I want to model a oscillatory flow passing a single cylinder in openfoam. I need to define the velocity and pressure boundary conditions. In the case of velocity boundary condition I defined the inlet as oscillatingfixedvalue and the outlet as zeroGradient (please correct me if I am wrong). However I am not sure about the pressure boundary. should it be just a zeroGradient or I also need to define it as oscillatingfixedvalue ( it has a COS sign instead of SIN in its equation, which may be a problem) . Thanks in advance for your help.
Relevant answer
Answer
Hi Dr. Haddadian 
ZeroGradient for pressure is reported inappropriate for an oscillating velocity inlet, for example, the first link below. 
However, some reports that zeroGradient is fine.
COS can be easily implemented using groovyBC, see the second link for example.
I think it is  a good idea to start from simple boundary conditions like zeroGradient.
Regards,
Yan
  • asked a question related to Civil Engineering Software
Question
7 answers
I have the parabolic function load and I want to model a parabolic load in a beam.
Thanks.
Relevant answer
Answer
I do not think that it is possible. You should approximate it as a series of linearly varying load (several trapezoidal distributed loads) and then apply the distributed load with. Assign> frame loads.
Functions are used for defining dynamic load to describe how load varies as a function of period or time. There are two types of functions:
  1. Response-spectrum functions: Pseudo-spectral acceleration vs. period for use in response-spectrum analysis
  2. Time-history functions: Loading magnitude vs. time for use in time-history
  3. analysis.
Functions are not used for static analysis.
  • asked a question related to Civil Engineering Software
Question
7 answers
i conducted non-linear static analysis over a steel structure in ETAB software.What are the results obtained after the analysis?is it possible to find ductility and energy dissipation of structures
Relevant answer
Answer
Dear Nincy
Yes, you can calculate the ductility and energy dissipation capacity of structures from pushover analysis. I will try to explain it one by one.
1. Ductility
Before starting my explanation, ductility can be referred to any different levels, for example, ductility in the level of curvature, component rotation, component displacement, or overall building behavior. Let us assume that you have done the pushover analysis and one of the most important factor that you need to find straight away is the global building ductility. Ductility itself means the capability of structure to undergo inelastic deformation. It can be calculated by dividing the ultimate roof displacement at failure with the displacement at the first significant yield. Finding the ultimate displacement is quite easy because you will automatically get this point where your model reaches certain failure drift (when your pushover analysis stops or reach certain drift target). The challenge itself is finding the significant yield displacement. One of my recommendation is by trying to find a point of the step where the stiffness of the building drops significantly at the first time. That is the point of significant yielding.
2. Energy dissipation
When you are trying to calculate the energy dissipation of the building, you can calculate this parameter manually by finding the area below your capacity curve (roof drift vs base shear curve). But if you want to find the energy dissipation per element for example. You need to extract the hinge results from output data and calculate the area below the curve for each elements that you want to observe.
I hope my answer can give you an insight about your question. Feel free to discuss.
Best regards,
Andri Setiawan
  • asked a question related to Civil Engineering Software
Question
9 answers
I have downloaded this sketchup file and when I looked at the floor plan, there were thick walls that support beams. I'm not sure if it's a column or just wall. It extends up to 2 meters length and 0.3 m wide. Most columns are 0.5m x 0.5m. Could this be a column? 
Relevant answer
there is in plan buckling and out of plan buckling if the rectangular ratio (width to length) of the rectangular increase there is a possibility in buckling occur at the weak axis of the rectangular
  • asked a question related to Civil Engineering Software
Question
6 answers
Previously, i read an article mentioned that FLAC can model such problem's by using THOGH code. Does anyone know about this modeling and THOGH-FLAC it self?
And, which software's can consider unsaturated condition?
Relevant answer
Answer
Yes there are finite element codes that can deal with the unsaturated conditions.
  • asked a question related to Civil Engineering Software
Question
9 answers
We are trying to transform fracture frequency P10 along the scanline of a tunnel wall to P32, a volumetric intensity measure. Wang, 2005 suggest a methodology in his PhD dissertation to determine this volumetric intensity measure but it is not clear how the direction cosine and the angle between the fisher mean pole and the scanline is determined. Thank you
Relevant answer
Answer
Thank you Ms. Tsambani.
  • asked a question related to Civil Engineering Software
Question
4 answers
Hi all,
I'm using Abaqus to model the linear response of plain concrete tunnel linings.
I created different part instances so that I can mesh them independently and therefore have a symmetric mesh.  However these instances don't seem to be connected and when I try to run the analysis abaqus tells me that these regions are unconnected.
Can anybody help?
Relevant answer
Answer
Thanks for the replies, I have solved the problem by using constraints.
Thank for your help!
  • asked a question related to Civil Engineering Software
Question
7 answers
I want to use an open source and concrete software for future academic works. Please share your opinions about the various free concrete design software.
Relevant answer
Answer
I agree with Mohsen. If you want something free and open, suitable for research purposes, go with Opensees. You can find it at http://opensees.berkeley.edu/
Version 2.4.6 is the latest stable release
Ansys, SAP and others that were mentioned are also fine, but they are NOT free and NOT open source. They are commercial software that you have to pay for.
Opensees is not the easiest software to use, you need some basic programming skills in order to use it and there is no good GUI (Graphical User Interface). The best things with the program can be done with a text editor (writing code in TCL) and no GUI. 
But I don't think that you can do much on design itself with it. Opensees is a good software for structural analysis (linear, non-linear, dynamic, steel/concrete, etc), but I don't think it has ready-to-use features for the design itself. You have to take care of the design requirements yourself - the software will help you only for analysis purposes.
  • asked a question related to Civil Engineering Software
Question
2 answers
I have tried with Geostatic and Static General but there is significant deformation and non convergencies. 
Relevant answer
Answer
The suitable option is *Dload in the input file. Take a look at the attached file which has gravity loads in model containing C3D8R and CIN3D8 elements.
HTH
George