Will Hansen’s research while affiliated with University of Michigan and other places

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


Pore Structure Of Hydrated Cement Determined By Mercury Porosimetry And Nitrogen Sorption Techniques.
  • Article

February 2011

·

31 Reads

·

8 Citations

Materials Research Society symposia proceedings. Materials Research Society

·

Will Hansen

The pore structure (i.e. total pore volume, surface area and pore-size distribution curves) was measured using mercury porosimetry and nitrogen sorption. Hydrated portland cement (type I) of water-cement (w/c) ratios 0.3, 0.4 and 0.6 by weight was analyzed at three degrees of hydration (i.e., 30%, 50% and 80%; 70% for the 0.3 w/c system) corresponding to low, intermediate and high levels of hydration. The effect of curing temperature (3°, 23°, and 43°C) on pore structure was also studied. The two techniques were evaluated as well on porous Vycor glass, which has a narrow pore size distribution in the size range accessible to both. Results obtained by both techniques on porous Vycor glass agreed well. However neither technique can be used alone to study the entire pore structure in well-hydrated cement due to the wide range in pore sizes and the presence of micropores. Due to the unstable pore structure in cement a specimen treatment procedure such as methanol replacement, combined with volume-thickness (V-t) analysis, is necessary in order to measure the micropores. At low hydration values the pore structure can be estimated by mercury intrusion porosimetry (MIP). At higher hydration values, however, this technique underestimates total pore volume and surface area due to the presence of micropores which MIP cannot determine. In the pore size range of overlap, higher pore volumes were obtained with MIP. Nitrogen V-t analysis shows that micropores are more pronounced with lower w/c ratios. This finding is consistent with pore size distribution curves obtained by MIP. For a given w/c ratio and degree of hydration the total pore volume measured by MIP was found to be independent of curing temperature in the temperature range studied. At any w/c ratio, capillary porosity is controlled by degree of hydration alone.

Citations (1)


... The NS pore size distribution revealed that the nanoscale pore structure around 10 nm of SACs was consistent with the SEM and MIP analyses. The detectable ranges of NS and MIP were 4-3 × 10 5 nm and 0.35-100 nm, respectively, and the results from NS were more reliable than MIP within the pore width of 0.35-100 nm in this case [22][23][24][25]. So, we adopted the result from NS for the range of nano pores and MIP for the micron pores. ...

Reference:

Facile Preparation of High Strength Silica Aerogel Composites via a Water Solvent System and Ambient Pressure Drying without Surface Modification or Solvent Replacement
Pore Structure Of Hydrated Cement Determined By Mercury Porosimetry And Nitrogen Sorption Techniques.
  • Citing Article
  • February 2011

Materials Research Society symposia proceedings. Materials Research Society