Wei Zhou’s research while affiliated with Shenyang University of Technology and other places

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (2)


Axial vibration analysis of power transformer active part under short-circuit
  • Conference Paper

August 2011

·

56 Reads

·

17 Citations

·

Wei Zhou

·

Yongteng Jing

·

Based on 500kV power transformer, according to the mass-spring system model for the axial vibration of power transformer winding and its nonlinear characteristics, a calculation model is simplified, the modal simulation system of power transformer active part, which composes of core, windings, tensile plates and clamp frames is established, the natural frequencies and vibration modal in different levels of axial pre-compression of transformer active part are calculated, the relations between the changes of axial pre-compression and axial vibration natural frequencies on transformer active part are investigated. Meanwhile, the active part vibration caused by axial short-circuit forces of windings under short-circuit conditions is analyzed.


The analysis and computation of transformer winding short-circuit current and strength on permanent fault after reclosing

August 2011

·

51 Reads

·

1 Citation

·

·

Jian Li

·

[...]

·

Dongxue Li

This paper has analyzed the change of power transformer short-circuit current after reclosing when a permanent faults has occurred on system. The transient process of winding flux and inrush current has been analyzed, and the different of current between initial short-circuit and reclosing can be given. The simulation results of inrush current after reclosing has been given through matlab simulation, it can be as a known condition to calculate winding electromagnetic force, and the winding strength will be checked finally. It has some significance to guide project design.

Citations (1)


... In the case of sudden short-circuit of distribution transformer, huge short-circuit force will be produced in the winding. If the transformer design is not perfect and the short-circuit resistance is not enough, such huge short-circuit force will damage the winding insulation and structural parts, affect the insulation performance of the transformer, or loose the winding, twist and deformation, break the wire, or even collapse the whole winding, or due to insulation loss The winding is burnt out due to the turn to turn short circuit [4,5] . ...

Reference:

A Novel Method for Distribution Transformer Short-circuit Test
Axial vibration analysis of power transformer active part under short-circuit
  • Citing Conference Paper
  • August 2011