S Nussbauber’s scientific contributions

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


Validity and Reliability of Optojump Photoelectric Cells for Estimating Vertical Jump Height
  • Article
  • Full-text available

February 2011

·

4,415 Reads

·

658 Citations

The Journal of Strength and Conditioning Research

Julia F Glatthorn

·

Sylvain Gouge

·

S Nussbauber

·

[...]

·

Vertical jump is one of the most prevalent acts performed in several sport activities. It is therefore important to ensure that the measurements of vertical jump height made as a part of research or athlete support work have adequate validity and reliability. The aim of this study was to evaluate concurrent validity and reliability of the Optojump photocell system (Microgate, Bolzano, Italy) with force plate measurements for estimating vertical jump height. Twenty subjects were asked to perform maximal squat jumps and countermovement jumps, and flight time-derived jump heights obtained by the force plate were compared with those provided by Optojump, to examine its concurrent (criterion-related) validity (study 1). Twenty other subjects completed the same jump series on 2 different occasions (separated by 1 week), and jump heights of session 1 were compared with session 2, to investigate test-retest reliability of the Optojump system (study 2). Intraclass correlation coefficients (ICCs) for validity were very high (0.997-0.998), even if a systematic difference was consistently observed between force plate and Optojump (-1.06 cm; p < 0.001). Test-retest reliability of the Optojump system was excellent, with ICCs ranging from 0.982 to 0.989, low coefficients of variation (2.7%), and low random errors (±2.81 cm). The Optojump photocell system demonstrated strong concurrent validity and excellent test-retest reliability for the estimation of vertical jump height. We propose the following equation that allows force plate and Optojump results to be used interchangeably: force plate jump height (cm) = 1.02 × Optojump jump height + 0.29. In conclusion, the use of Optojump photoelectric cells is legitimate for field-based assessments of vertical jump height.

Download

Citations (1)


... Since its establishment over 10 years ago, the research team of the Center of Research, Studies in Physical Education, Sport and Health (CRSPES) has continuously managed to create useful methods of testing and follow-up monitoring of various parameters and programs. It should be noted that before the test, a workshop was held with the entire research team to discuss methods for testing the relevant parameters presented in this study and the progress in testing with technological equipment, as is the case for speed evaluation using the WITTY photocell system from Microgate, ITA [28], as well as Microgate's OptoJump system [29]. Also, during the execution of the work, the passes (which happened the day before going to the field), testing, and valorization with subsequent tests were carried out with the aim of having as few errors as possible or trying to avoid any complete or occasional omissions in the data. ...

Reference:

Relative Age Effect (RAE) According to Norm Values on Anthropometric Performance and Physical Fitness in 9-11-Year-Old Children
Validity and Reliability of Optojump Photoelectric Cells for Estimating Vertical Jump Height

The Journal of Strength and Conditioning Research