This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (25)


The influence of nonlinear load on the autonomous electrical network at parallel work of the active power filter
  • Article
  • Full-text available

December 2020

·

18 Reads

Electrical Engineering and Power Engineering

R.V. Vlasenko

·

Purpose. The purpose of the article is to investigate the modes of operation of a three-phase active power filter in the composition of an autonomous electrical network when connected to a network of three-phase nonlinear load of different spectral character. Methodology. For the purposes of the research, we used the provisions of pq-theory of power, theory of electric circuits, theory of automatic control, mathematical modeling in the Matlab package. Findings. The obtained graphs and spectral composition of the network voltage, load current, which allows to evaluate the efficiency of the use of a active power filter in the filtering mode in the autonomous electric network, which is a synchronous generator. Originality. Efficiaty parallel operation of a active power filter in the filtering mode with a synchronous genera-tor under sharply variable non-linear loading is proved. Practical value. Using the proposed method will allow to create a three-phase active power filter for its applica-tion in autonomous electrical networks, represented by a synchronous generator with automatic control of the excita-tion voltage.

Download

ДОСЛІДЖЕННЯ РЕЖИМУ ТРИФАЗНОГО СИЛОВОГО АКТИВНОГО ФІЛЬТРА В СИЛОВОМУ КОЛІ ДУГОВОЇ ПЕЧІ ПРИ КОЛИВАННЯХ АКТИВНОЇ ПОТУЖНОСТІ

December 2019

·

138 Reads

Arc furnace is a common smelting furnace for metallurgical production. At the same time, there is a stochastic operating mode in the arc furnace, that widespread in the industry. The combustion arc in the arc furnace is accompanied by a generation to the power supply network of reactive power, higher harmonics and there is asymmetry of currents. This leads to fluctuations not only in reactive power, but also causes fluctuations in active power. Static compensating devices such as condenser batteries, power passive filters, synchronous compensators do not have time to react to the sharply variable operating mode of the arc furnace. The latest advances in the compensation of inactive components power are the use of three-phase active power filters, which do not have the phenomenon of resonance of voltages and currents, as well as they react to change the load during their work. In the work the model of the three-phase active power filter with an arc furnace to the visual modeling environment is synthesized. The parameters of the arc fur-nace substitution scheme are brought to the low side of the electric transformer the furnace. Parameters of three-phase active power filter are calculated for this type of arc furnace. In the course of the study, ob-tained the data of the consumption of active and reactive power of the load and the network, as well as the coefficient of distortion of the sinusoidality of the current load curve and the network. The received oscillo-gram of network voltage, load current, current active power filter, network current and spectral diagram of higher harmonics of load current and network. All the results obtained were analyzed and perform conclu-sions for them.





Interrelation of a clarke and fortescue transformation for the three-phase asymmetrical electrical network

August 2019

·

30 Reads

Purpose. Determination of the analytical interrelation of Clarke and Fortescue transformation for an asymmetric sinusoidal system of currents of a three-phase four-wire network. Methodology. To find the way for the use of the direct, reverse and zero sequences as components of the power circulating in the intersection of the four-wire current line, a problem is set to determine the interrelation of Clarke (α-β-0) and Fortescue (1-2-0) transformations. An analysis of the order of calculation of the direct, reverse and zero sequences components is carried out for the general case and for every separate phase. Comparison of Clarke transformation for separate sequences is performed using Euler formulae in an exponential form. Analytical relations determining the components of the current and voltage of direct and reverse sequences in domain α-β-0 are obtained. The said relations are used as the basis for instantaneous power decomposition in the use of p-q theory. The performed numerical calculation of current and voltage components, as well as power according to p-q theory, confirms the obtained analytical results. Findings. Interrelation of direct and reverse sequence conversion of voltages (currents) in domain 1-2-0 (Fortescue transformation) with voltages (currents) in domain α-β-0 (Clarke transformation) is analytically substantiated, which makes it possible to separate in the latter the components caused by the action of direct and reverse sequences. Originality. Analytical determination of direct, reverse sequence components in domain α-β is proposed to use these components during calculation of instantaneous power according to p-q theory for four-wire lines. Practical value. The obtained results present a part of the analysis of electric power components in electrical four-wire networks with asymmetric parameters of the mode and they can be developed for networks with nonsinusoidal voltages and currents.


Figure 2 -Functional diagram of the three-phase parallel active power filter of the pre-charged subsystem of the capacitor
Figure 3 -Oscillograms, in which: a -load current ld i ; b -given APF current APF i ; c -mains current S i ; d -capacitor voltage dc U CONСLUSIONS. 1. The process of APF voltage control of he capacitor can be technically implemented without usage of additional devices, by adjusting the basic compensation algorithm. 2. The process of controlling by the charge of the capacitor requires restrictions on the minimum level voltage, provided management of APF, for a maximum voltage and current conditions on the choice of the elements of the power circuit. 3. The charging process and discharging of the capacitor may occur along with the process of compensation and no matter, as long as does not exceed the maximum current of the compensator valve. 4. Charge the capacitor at the beginning of the scheme takes place uncontrollably through the counter of the diodes circuit, causing an inrush current, which is limited inductance range of APF network.
THREE-PHASE PARALLEL ACTIVE POWER FILTER SYSTEM PRE-CHARGE CAPACITOR

August 2019

·

155 Reads

·

1 Citation

International Transactions in Operational Research

ua Purpose. Development of a subsystem of the previous phase capacitor charging power of parallel active filter as part of the control system. Methodology. Based on the analysis set out in known publications implement subsystem previous charge the capacitor, which provides support and control DC voltage in a given range of compensation provided in the inactive components of power. On the basis of the order of formation current power active filter selected parameter is used to set the intensity of battery-power. The algorithm of compensation, further comprising adjusting the current power active filter equivalent to the value of charging power under conditions of capacitor voltage deviation limits specified range. Results. Based on an algorithm taking into account the known technical solutions developed active filter circuit of the power subsystem charge the capacitor. Through modeling experiments implemented in algorithm modes and the correct conclusions. It is noted that at the beginning of the scheme is unmanageable because of counter-diode circuit, causing the current cast, which limited inductance range of network power active filter. Originality. When using SAF quality testing given current vary depending on the power circuit and the voltage level of the ca-pacitor. The voltage capacitor for handling should be higher than the voltage, in some cases-much higher. In a famous study dedicated modes SAF authors examined the scheme processes and modes of position provide the necessary current levels SAF network, but the formation of the charge in the capacitor DC link remains unexplored. There are technical solutions that provide the capacitor charging process with certain conditions and requirements, but the use of additional circuitry to implement a charge capacitor when SAF leads to complications schematics and accordingly the use of appropriate controls. Practical value. In the course of an experiment for the following modes: charge the capacitor SAF mode of compensation for the load conditions, compensation for increased load conditions. References 13 Figure 3. Key words: active power filter, battery capacity, charge level of the capacitor, pq-power theory.



ASSESSMENT OF ELECTRICAL NETWORK POWER COMPONENTS DURING OPERATION OF AN ACTIVE POWER FILTER ACCORDING TO IEEE 1459-2010 STANDARD

August 2019

·

39 Reads

The paper deals with assessment of power components according to ІЕЕЕ 1459-2010 standard during operation of a three-phase active power filter in complex with a nonlinear unbalanced load under the conditions of balanced and unbalanced network voltage. Correction of the algorithm of Fryze theory taking into consideration the cases of load currents' and network voltage unbalance has been proposed. Fryze algorithm correction is performed with determination of power and currents values according to ІЕЕЕ 1459-2010 standard. A comparative assessment of the quality of operation of the active power filter has been carried out with the use of algorithms based on different power theories (pq-theory, Fryze theory). OCENA KOMPONENTÓW MOCY SIECI ELEKTRYCZNEJ PODCZAS PRACY AKTYWNEGO FILTRA WEDŁUG IEEE 1459-2010 STANDARD Streszczenie. Praca dotyczy oceny składników energetycznych, zgodnie z normą ІЕЕЕ 1459-2010 podczas działania trójfazowego filtru aktywnego w kompleksie z nieliniowym o obciążeniu niesymetrycznym w warunkach zrównoważonego i niezrównoważonego napięcia sieci. Autorzy zaproponowali algorytm korekcji oparty na teorii Fryzego. Algorytm ten został opracowany z określeniem wartości mocy i prądów ,zgodnie z normą ІЕЕЕ 1459-2010. Porównawcze oceny jakości działania filtru aktywnego zostały przeprowadzone z wykorzystaniem algorytmu na podstawie teorii mocy (pq-teorii, teoria Fryzego).


Investigation of the effect of method and parameters of the control of one-phase active filter on quality of electric energy

June 2019

·

26 Reads

Power active filters are widespread devices and attract the attention of researchers due to their multifunctional properties, such as reactive power compensation, filtering of higher current harmonics and load balancing. The IGBT modules as a switches of converter are used to build the modern power filter. An important aspect in designing the device is the system for forming the control pulses for these switches. The paper deals with the most common systems for forming control pulses, which are based on the relay control methods and pulse-width modulation control methods. A comparative study of two control systems was carried out and the time diagrams of the filter currents and their spectrums were obtained. According to the performed research the conclusions with the recommendations are presented.


Citations (11)


... The APF, shunt hybrid active power filter (SHAPF), and current decomposition reduce harmonics, reactive power, and load imbalance. Also, the use of APF/SHAPF in load imbalance conditions is carried out, using hysteresis control [20], IRPT [21], [22], SRF [23], [24], and fuzzy [25], [26]. The harmonic currents in this study were reduced through SHAPF with model predictive control (MPC) at a balanced load in three-phased three and four wires [27] and discussed in a separate article. ...

Reference:

Three-phase four-wire shunt hybrid active power filter model with model predictive control in imbalance distribution networks
Four-Wire Three-Phase Active Power Filter With Fuzzy Controller For Compensation Of Distortion of Currents Unbalance in the Conditions of Fluctuated Load
  • Citing Conference Paper
  • September 2019

... Since it is operating with an MPC controller, APF becomes more reliable compared to passive filters [4][5]. Several references talked about SAPF techniques as three-phase and using the park -Clark transformation [6][7][8][9][10][11]. ...

THREE-PHASE PARALLEL ACTIVE POWER FILTER SYSTEM PRE-CHARGE CAPACITOR

International Transactions in Operational Research

... These issues consequently lead to increased energy losses, for example, in transmission lines. Mitigation of such problems can be achieved through various means such as unified power quality conditioners (UPQCs) [2] or active power filters (APFs) [3], for example. However, the correct design and installation of these power quality improvement systems require a reliable EAF model [4]. ...

Analysis of three-phase parallel active power filter operation mode with arc furnace active power’s fluctuations

... As shown in [9], the both structures of fuzzy controllers based on the rules of Mamdani and Sugeno bases are the same, but they differ if compare their settings [9]. In comparison with the Mamdani algorithm, Sugeno's algorithm differs in the following [11]: the number of rules is reduced to four in comparison with nine in the Mamdani algorithm; the number of control points is taken twenty-one (step is equal to one) in comparison with the number of control points is taken three (step is equal to ten) in the Mamdani algorithm; the control surface is nonlinear in in comparison with the linear one in the Mamdani algorithm. ...

FUZZY-PID CONTROLLER IN THE PULSE WIDTH MODULATION SYSTEM FOR CONTROLLING OF THREE-PHASE PARALLEL ACTIVE POWER FILTER CONVERTER

... Певним досягненням силової перетворювальної техніки в частині компенсації неактивних складових потужності (реактивної потужності та вищих гармонік струму) є застосування силових активних фільтрів (САФ). САФ поєднують в собі функції компенсації реактивної потужності, фільтрації вищих гармонік струму та симетруванні струмів навантаження застосування шляхом використання певних алгоритмів активної фільтрації [2,3]. ...

LIMITATIONS OF CURRENT OF THE THREE-PHASE ACTIVE POWER FILTER IN THE CONDITIONS OF OVERLOAD AND SHORT CIRCUIT

Electrical Engineering & Electromechanics

... Недоліком даного способу є субгармоніки, які виникають при зміні частоти комутації. В порівнянні з ШІМ метод РР має більш просту будову, зокрема, відсутні складні налаштування ПІ-регулятора, має кращі показники регулювання при роботі з різними сигналами напруги мережі [13]. Зважаючи на зазначені переваги РР, для подальших досліджень обрано систему керування силовим активним фільтром з РР. ...

FUZZY-PID CONTROLLER IN THE METHOD PULSE WIDTH MODULATION CONVERTER ACTIVE POWER FILTER
  • Citing Article
  • June 2018

ELECTRICAL AND COMPUTER SYSTEMS

... The problem of harmonic power quality affects business productivity and causes high economic value (6). From these losses, a solution is needed to reduce power quality problems so that they are not negatively affected by nonlinear loads from other consumers by using active filter devices (7). Harmonic compensation can be done by combining a passive filter and an active filter (8). ...

INVESTIGATION OF THE INFLUENCE OF THE TRANSFORMER OF A SERIES ACTIVE FILTER ON THE QUALITY OF VOLTAGE

Electrical Engineering and Power Engineering

... 3a) та включає три трансформатори (Linear transformer 1-3) первинна обмотка яких під'єднана в розрив силового кола фаз мережі. Для спрощення дослідження режиму вторинна обмотка отримує живлення від програмованого джерела ЕРС (Controlled voltage sourse[1][2][3]. Керуючим сигналом джерела ЕРС є сигнал * SF u . ...

THE ANALYSIS OF ENERGY PROCESSES IN THREE-PHASE ACTIVE POWER FILTER USING SPECTRAL MODELING

Electrical Engineering and Power Engineering

... To implement the developed technique, a block diagram of the subsystem of the current limitation of the active power filter shown in Fig. 1 is proposed. The proposed block diagram ( Fig. 1) is implemented in the subsystem of current formation (pq-theory power control), the control system of the APF in the composition of the electric power complex whose model (Fig. 2) is constructed in a graphical environment of simulation modeling and described in [9]. To determine the current of the compensation of the APF, the pq-theory of instantaneous power [4] was chosen, and as the method of pulse control of transistors of the converter -the method of relay current control (RCC) [11], the block (Relay current control) (Fig. 2). ...

ADAPTIVE CONTROL OF CURRENT CONTROLLER RELAY FOR THREE-PHASE ACTIVE POWER FILTER

Electrical Engineering and Power Engineering

... Algorithm for current formation is laid in Block determining given current APF (Current generation block). This block is built on the basis of the theory of full power Fryze and presented in the paper [5]. Block of control pulses for switch elements of the converter (Pulse shaping block) realizes method relay current control, that used in work [6]. ...

CORRECTION ALGORITHM FOR DETERMINING THE GIVEN CURRENT ACTIVE POWER FILTER BASED ON THE THEORY POWER FRYZE IN TERMS OF ASYMMETRY

Electrical Engineering and Power Engineering