This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


Ground Selector for Ungrounded Three-Phase Distribution Systems
  • Article

January 1923

·

4 Reads

·

6 Citations

P. Ackerman

Ever since three-phase distribution has been known, a controversy has been going on with respect to the relative merits of grounded and ungrounded neutral. The inability of locating and isolating a ground fault is the chief disadvantage of the ungrounded neutral system, this being the reason why lately the grounded neutral has been given preference. The purpose of the so-called ground selector is to provide means to permit the selective clearance of a ground fault in an ungrounded neutral system. The device thus eliminates the mentioned disadvantage and raises the ungrounded neutral system to the same operating ating standard as the grounded neutral system, retaining at the same time the many other advantages inherent to the ungrounded system. The paper describes the functioning of the ground selector and compares in detail the two systems. Two ground selector installations on largely different systems are described and the practical operating results are reported and discussed. The conclusion is reached that the ungrounded neutral system equipped with a ground selector combines the advantages of the ungrounded and grounded neutral systems without being afflicted with their respective disadvantages.

Citations (1)


... A method of temporarily changing an ungrounded system into a grounded system, thus enabling the fault to be detected, was described by Ackerman [17] in 1923. in the 1950s, a pulsing device was developed that, when attached to an ungrounded electrical distribution system, would put electrical current pulses on the energized electrical system, which would allow someone with a sensitive ammeter to clamp around the conductors or, if the conductors were in a conduit, around the conduit. The electrical pulse would hopefully have a stronger deflection of the ammeter on the conduit containing the faulted conductor allowing one to find the fault location. ...

Reference:

A History of Grounding and Earthing Practices in the United States: Part 1: A Discussion of How the Earth Has Been Used for Electrical Conduction Through the 1920s
Ground Selector for Ungrounded Three-Phase Distribution Systems