Maan Ahamed Fadhil’s scientific contributions

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


Figure 1. A description of blood glucose monitoring methods.
Figure 2. The HB-100 Microwave Sensor's circuit Experimental Measurement of Blood Dielectric Properties
Figure 3. Model of a theoretical system.
Figure 4. Integrated experimental system setup
Innovative Non-Invasive Blood Sugar Level Monitoring for Diabetes Using UWB Sensor
  • Article
  • Full-text available

October 2022

·

461 Reads

·

4 Citations

Marwa Mawfaq

·

·

·

[...]

·

Ghanim Al-Sultan

Globally, hundred millions of person are affected of diabetes, whether Type-1-or Type-2-, affects people all over the world, and diabetes is a leading cause of mortality in many nations. Regular the level of sugar in the blood in both types assist to reduce the danger of diabetes hyperglycemia (blood sugar levels > 200 mg/dL) or hypoglycemia (blood sugar levels < 70 mg/dL) problems, for example, Kidney failure, heart problems, blindness, and even death are all possibilities. They need frequently check the sugar level of blood in a day. This is one of the most crucial challenges that diabetics often face to take a blood sample and measure the sugar level daily. Numerous non-invasive methods have been proposed to solve this problem. Most previous articles are inaccuracy and most of these studies independent on blood directly. The objectives of this research are to design and implement a prototype of a wearable (UWB) non-invasive system that can prevent infections with low cost and low complexity, to minimize the error in readings of patients when they use invasive or non-invasive ways to improve the lifestyle and To find a certain technique that can be used in vast field with the patient himself at any time. The proposed UWB has been achieved an integrated easy, flexible, wearable and good accuracy. The UWB outperformed previously implemented systems shown in earlier works, both in terms of easy to use and low cost.

Download

Citations (1)


... Monitoring technology and advancements in medical industry technology have had a significant impact on our daily lives [11], [12], [13,14,15,16,17]. Among the various biological signals used in Monitoring health applications, the ECG signal is commonly employed. ...

Reference:

Clinical Fusion for Real-Time Complex QRS Pattern Detection in Wearable ECG Using the Pan-Tompkins Algorithm
Innovative Non-Invasive Blood Sugar Level Monitoring for Diabetes Using UWB Sensor