This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (3)


Concept of new power supply system topology using 380 V and 48 V DC bus for future datacenters and telecommunication buildings
  • Conference Paper

October 2015

·

4 Reads

·

7 Citations

Toru Tanaka

·

Naoki Hanaoka

·

Akiko Takahashi

·

[...]

·

Nobuhiko Yamashita

HVDC Power Supply System Implementation

March 2015

·

22 Reads

·

2 Citations

NTT Technical Review

The high-voltage direct current (HVDC) power supply system is ready to implement and is expected to reduce energy consumption and costs in telecommunication buildings and datacenters. In this article, we explain the implementation status of this system and discuss standardization efforts. We also review the technical requirements and power supply system guidelines that were developed by the NTT Group to further promote HVDC systems. © 2015, Nippon Telegraph and Telephone Corp. All rights reserved.


Citations (3)


... As can be observed from Fig. 4, the circuit features a few passive components, such as , , and , where and are the LLC series resonant inductor and capacitor, respectively, and is the magnetizing inductor [19,21]. The magnetizing inductance behaves as a shunt inductor [22]. Fig. 5 also displays the circuit switching waveforms. ...

Reference:

Performance Comparison Analysis of a High Voltage DC LLC Resonant Converter for Telecom and Datacenter Applications
Concept of new power supply system topology using 380 V and 48 V DC bus for future datacenters and telecommunication buildings
  • Citing Conference Paper
  • October 2015

... -Inrush currents: the power electronic converters are equipped with electromagnetic interference filters. However, the inrush current that passes through these filters will produce voltage fluctuations in the DC bus and ultimately affect the operation of other devices connected to the common DC bus [85]. ...

Effect of inrush current flowing into EMI filter on the operation of ICT equipment in HVDC system
  • Citing Conference Paper
  • September 2014

... Nippon telegraph and telephone (NTT) is a Japanese telecommunications company headquartered in Tokyo that has carried out substantial research on the distribution of high voltage DC power to telecommunications and data center applications. NTT published an article in 2015 [68] on the implementation of a 100-kW system with a maximum rated voltage of 400 VDC as a distributed voltage to meet the basic requirements of ITU-T L.1201 [69] international standards. ...

HVDC Power Supply System Implementation
  • Citing Article
  • March 2015

NTT Technical Review