Karloren Guzmán’s research while affiliated with University of New Orleans and other places

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


Fig. 1. Sketch of the system and its components
Fig. 3. Manning's n coefficient versus Reynolds number with biofilm for 0.1 and 0.5% slopes, d 0 = 200 mm
Table 3 . Summary of Critical Shear Stresses D 90 = 0.4 mm Applicable to 150-and 200-mm PVC Sewer Pipes
Fig. 4. Manning's n calculated at different ratios of depth with film at different ages and without biofilm for 0.5% slope, d 0 = 200 mm
Fig. 6. Manning's n calculated at different ratio of depths with biofilm on 0.1 and 0.3% slopes, d 0 = 150 mm

+1

Effect of Biofilm Formation on Roughness Coefficient and Solids Deposition in Small-Diameter PVC Sewer Pipes
  • Article
  • Full-text available

April 2007

·

1,973 Reads

·

32 Citations

Journal of Environmental Engineering

Karloren Guzmán

·

·

·

[...]

·

Maria Ermogenous

The purpose of a sanitary sewer is to carry the peak discharge at the end of the design period, and to transport suspended materials under all flow conditions to prevent deposition of solids, and hence, sewer blockages. To accomplish the latter, the liquid must provide for sufficient shear stress to suspend and transport the particles along the sewer. Published design criteria for critical shear stress in sanitary sewers vary significantly. However, the effect of biological film development on the internal pipe surface has been neglected. Experiments conducted utilizing a pilot-scale sanitary sewer installed in the Hydraulics Laboratory at the University of New Orleans, La., provide evidence that the shear stress to move particles of a given size is independent of slope and pipe diameter, but does depend on the effect of biological film on increasing the roughness coefficient. This critical shear stress, to achieve self-cleansing in sanitary sewers, was found to be in the range of 1.1– 1.4 N / m 2 , depending on the integrity of the biofilm. Based on this principle, a design procedure applicable to small-diameter PVC pipes with slopes between 0.1 and 0.5% was developed.

Download

Citations (1)


... When the shear force in sewers is 1.1-1.4 Pa, it promotes biofilm growth, which may increase the risk of harmful gas generation [28,43] (Figure 2e). ...

Reference:

Methane Production Mechanism and Control Strategies for Sewers: A Critical Review
Effect of Biofilm Formation on Roughness Coefficient and Solids Deposition in Small-Diameter PVC Sewer Pipes

Journal of Environmental Engineering