This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (8)


Análise de um Aerogerador com Gerador de Indução Duplamente Alimentado Durante um Afundamento de Tensão
  • Conference Paper

October 2022

·

2 Reads

Sba Controle & Automação Sociedade Brasileira de Automatica

Vítor M. Ramos

·

Damásio Fernandes Jr

·

Washington A. Neves

This paper presents the performance analysis of a variable speed wind turbine with a doubly fed induction generator during a grid voltage dip. Simluations are performed with and without the installation of the crowbar protection, tipically present in this kind of wind turbine. It was possible to observe the consequences of the voltage dip on the generator, as well as the importance of the protection to keep the wind turbine within the safe operation conditions.



Métodos para Detecção de Faltas em Linhas de Transmissão do tipo HVDC Multiterminal

December 2020

·

1 Read

Propõe-se realizar um estudo comparativo entre os métodos de detecção de faltas em linhas de transmissão de corrente contínua multiterminal. Os métodos selecionados para o estudo comparativo pertencem ao grupo dos métodos baseados na teoria de ondas viajantes. Foram utilizados métodos que se baseiam na transformada wavelet discreta, na transformada wavelet discreta redundante, na transformada de park e um método que se baseia na energia da derivada de sinais. O desempenho dos métodos foi analisado com base em simulações realizadas via MATLAB/Simulink de um sistema HVDC (do inglês High Voltage Direct Current) multiterminal. Nas análises para avaliar o desempenho dos métodos, foram variados os pontos de falta, o tipo de falta e a resistência de falta, a fim de testar a robustez dos métodos para faltas de alta e baixa impedância. Em todos os métodos avaliados, foi aplicado um limiar autoadaptativo para detecção de faltas. A partir dos resultados, foi verificado que os métodos que fazem uso da transformada de park e da energia da derivada de sinais obtiveram os melhores desempenhos.


Aplicação de Métodos Numéricos na Estimação dos Parâmetros do Modelo de Módulos Fotovoltaicos com um Diodo

December 2020

·

3 Reads

Uma das etapas de fundamental importância na modelagem de módulos fotovoltaicos é o processo de estimação dos parâmetros, sendo os métodos de otimização ferramentas essenciais para a garantia de valores ótimos. Os métodos numéricos são ferramentas amplamente utilizadas nesses processos para obtenção desses parâmetros. Esse trabalho visa aplicar metodologias convencionais e de otimização na estimação dos parâmetros do modelo de um diodo de módulos fotovoltaicos, tendo em que vista que essa temática é imprescindível para estudos baseados em simulações com representação matemática do desempenho desses equipamentos. Por meio de análise estatística pode ser observada que a metodologia de Levenberg-Marquardt empregando como valores iniciais os resultados obtidos pelo método de Villalva levou o modelo a maior representatividade, para o modelo abordado em uma gama de irradiâncias. Dessa forma, pode-se chegar a uma estimação paramétrica que viabilize a melhor aproximação das condições fornecidas pelo manual do fabricante.


Métodos de Detecção de Faltas em Linhas de Transmissão de Corrente Contínua: Uma Análise Comparativa

August 2020

·

6 Reads

Propõe-se realizar um estudo comparativo entre os métodos de detecção de faltas em linhas de transmissão de corrente contínua. Os métodos selecionados para o estudo comparativo pertencem ao grupo dos métodos baseados na teoria de ondas viajantes. Foram utilizados métodos que se baseiam na transformada wavelet discreta redundante e um método que se baseia na energia da derivada de sinais. O desempenho dos métodos foi analisado com base em simulações realizadas via MATLAB/Simulink de um sistema HVDC (do inglês High Voltage Direct Current) bipolar. Nas análises para avaliar o desempenho dos métodos, foram variados os pontos de falta, o tipo de falta e a resistência de falta, a fim de testar a robustez dos métodos para faltas de alta e baixa impedância. Em todos os métodos avaliados, foi aplicado um limiar autoadaptativo para detecção de faltas. A partir dos resultados, foi verificado que os métodos que fazem uso da TWDR Haar e da energia da derivada de sinais obtiveram os melhores desempenhos, porém o método TWDR Haar possui um esforço computacional menor.



Coupling Capacitor Voltage Transformer: A Device to Correct its Secondary Voltage in Real Time

June 2013

·

103 Reads

·

14 Citations

Journal of Control Automation and Electrical Systems

Usually, the secondary voltage of a Coupling Capacitor Voltage Transformer (CCVT) is not a perfect replica of its primary voltage. In this study, the steps to design a hardware capable of performing the correction of the CCVT secondary voltage is presented. The device is basically a recursive digital filter whose parameters are obtained from the CCVT frequency response. The evaluation of the device is made by connecting it to the Real Time Digital Simulator (  RTDS TM\text{ RTDS }^\mathrm{TM} ) and carrying out real time simulations for two case studies: harmonic distortion and short-circuit in a 230 kV system. It is shown that the hardware device brings the CCVT secondary voltage waveform close to the primary voltage signal.


Transmission line controlled switching: A real time approach via RTDS
  • Article
  • Full-text available

April 2011

·

130 Reads

Sba Controle & Automação Sociedade Brasileira de Automatica

The goal of this work is to present a method for controlled switching of transmission line circuit-breakers and to develop a device to control the closing of its contacts. The switching strategy consists on finding a suitable circuit breaker making instant and it is based on a very simple zero crossing algorithm. For the first time, the method is evaluated in real time using a RTDSTM (Real Time Digital Simulator) and its implementation is accomplished in two ways: first, it is used the CBuilder tool of the RTDSTM and second, a DSP (Digital Signal Processor) is used as a control device. Data from the CHESF power system are used to produce case studies. Different line switching events are analyzed: closing and re-closing of shunt compensated lines taking into account trapped charge effects. The performance of the proposed method is compared to the pre-insertion resistors method. The simulations attest the efficiency of the controlled switching, which is economically more attractive.

Download

Citations (2)


... When a fault occurs, it is necessary to intervene and eliminate the resulting overcurrents as quickly as possible, maintaining the system stability, preventing its propagation and potential cascade shutdowns. Up to the present moment, there has been much research on relay protection schemes for ∕2+ lines in the literature, and some protection criteria have been improved: The work in [9] analyzed fault tripping criteria, [10] and [11] proposed new fault location algorithms, [12] and [13] proposed new methods adapting a differential protection scheme for ∕2+ lines, [14] developed a new faulty phase selector and [15] proposed a non-conventional distance protection setting for ∕2+ lines. ...

Reference:

Ground and phase fault classification for half-wavelength transmission lines relaying purposes
Fault location on transmission lines little longer than half-wavelength
  • Citing Article
  • September 2014

Electric Power Systems Research

... In the same way, the harmonic phases of CVT can also be corrected according to the phase deviation curves. Comparing with the capacitive current method, 1,11 the method 12,13 of harmonic measurement using amplitude-frequency characteristic curve of CVT does not change the internal structure of CVT and has great advantages in economy, practicability, and security. When using amplitude-frequency characteristic curve of CVT to correct the CVT harmonic voltages, the harmonic transfer characteristic curves of CVT must be fitted in the laboratory. ...

Coupling Capacitor Voltage Transformer: A Device to Correct its Secondary Voltage in Real Time
  • Citing Article
  • June 2013

Journal of Control Automation and Electrical Systems