This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (6)


GEORREFERENCIACIÓN DE LAS REDES DE DISTRIBUCIÓN ELÉCTRICA CON APOYO DE IMÁGENES DE SATÉLITE Y SERVICIOS DE CARTOGRAFÍA EN LA WEB
  • Chapter

December 2022

·

3 Reads

Carlos A. Agüero

·

·

Daniel O. Anaut

·

[...]

·

Juan Vignerte

A obra intitulada “Ciências exatas estudos e desafios vol.01”, publicada pela Brazilian Journals Publicações de Periódicos e Editora, apresentam um conjunto dezessete capítulos que visa abordar diversos assuntos relacionados com a área das ciências exatas. Entre eles, uma pesquisa com o intuito de testar a aplicabilidade da metodologia de medição da temperatura de corte do aço ABNT 1045 utilizando-se ferramenta de corte de carbeto metálico revestida com TiN em contato com termopar do tipo K conectado a um circuito de leitura composto de um Arduíno Uno e um computador. Também, uma proposta de análise experimental dos efeitos da técnica de diversidade aplicada na recepção móvel de sinal OFDM acústico submarino. Outra temática é um estudo de validação do desempenho lumínico de um edifício habitacional em Brasília através de simulação computacional e de medições. Assim como um estudo que tem por objetivo contextualizar o conceito da evolução tecnológica em respeito à neurociênciacomputacional a partir do funcionamento do sistema nervoso central humano, tendo comobase os sinais neurais elétricos, sua relação com o mundo no qual compartilhamos a vivência diária e a possibilidade do controle deste mesmo mundo. Um artigo com a finalidade de apresentar a modelagem matemática e simulação computacional do robô manipulador SCARA SR-6 iA da fabricante Fanuc. A demanda de conhecimento sobre robôs industriais, sua crescente utilização em diversos processos produtivos Entre outros. Gostaríamos de agradecer os autores que colaboraram no desenvolvimento dessa obra. Esperamos que a mesma auxilie na compreensão e argumentação dos assuntos aqui tratados.


Georreferenciación de las redes de distribución eléctrica con apoyo de imágenes de satélite y servicios de cartografía en la web / Georreferenciação de redes de distribuição eléctrica com apoio de imagens de satélite e serviço de mapeamento web

May 2022

·

5 Reads

Brazilian Journal of Development

La georreferenciación es un neologismo que hace referencia a la posición con la que se define la ubicación de un objeto espacial (representado por punto, vector, área, volumen) en un sistema de coordenadas y datum determinado. A partir de la georreferenciación, es posible integrar diferentes fuentes de información utilizando como elemento en común la correspondencia geográfica. En este trabajo se presenta la experiencia del grupo de investigación LAT de la Universidad Nacional de Mar del Plata en la georreferenciación del sistema de distribución de energía eléctrica en zonas urbanas y rurales. Se describen los criterios que permitieron aprovechar los planos de las redes de media y baja tensión en una empresa distribuidora del sudeste de la provincia de Buenos Aires evitando la redigitalización de las mismas con el apoyo de imágenes satelitales y servicio de mapeo web como el Bing Map.



Figura 5. Componentes armónicos de la corriente de fase como porcentaje de la fundamental.
Joule losses in feeders that transport harmonic currents in low voltage
  • Article
  • Full-text available

December 2013

·

26 Reads

Ingeniare Revista chilena de ingeniería

A study of Joule losses in electrical feeder lines carrying harmonic currents is presented. Different formulae proposed in the literature were used to estimate the neutral current and electrical losses. In the environment of the Alternative Transients Program, different levels of harmonic distortion were simulated, arriving at findings that show that losses may become considerably higher than in the condition in which active power without distortion is carried. A real case and the importance of reducing the harmonic content associated with losses are analyzed.

Download

Partial cancellation of harmonic currents caused by nonlinear residential loads

January 2005

·

8 Reads

·

5 Citations

Informacion Tecnologica

The index of harmonic distortion of different single-phase residential loads is evaluated and the importance of the effects of attenuation and diversity on the evaluation of distortion indexes of a power distribution system, is analyzed. Starting from signals of currents registered in the laboratory, the loads were modeled as fixed current sources. Then they were combined and simulated with the Electromagnetic Transient Program (EMTP), determining the resulting index of harmonic distortion. With models of nonlinear loads inserted in a distribution system, the diversity and attenuation phenomena were evaluated, in the following cases: i) connection of identical loads (with equal and different powers), and ii) variations in the impedance parameters of the distribution network. The results verify the fact that the rejection of such phenomena can cause an overestimation (up to 40%) in the evaluation of harmonics in a distribution system.


Cancelación Parcial de Corrientes Armónicas Provocadas por Cargas Residenciales No Lineales

December 2004

·

88 Reads

·

1 Citation

Información tecnológica

Se evalúan los índices de distorsión de distintas cargas monofásicas no lineales de uso residencial y se analiza la importancia que revisten los efectos de atenuación y diversidad en la evaluación de los índices de distorsión en sistemas de potencia. A partir de señales de corrientes registradas en laboratorio se modelaron las cargas como fuentes de corrientes fijas. Luego fueron combinadas y simuladas con el Programa Transitorios Electromagnéticos (EMTP), determinando el índice de distorsión armónica resultante. Con modelos de cargas no lineales insertados en un sistema de distribución, se evaluaron los fenómenos de diversidad y atenuación, en los siguientes dos escenarios: i) conexión de cargas idénticas (con potencias iguales y distintas), y ii) variaciones en los parámetros de la impedancia de la red de distribución. Los resultados verifican que despreciar dichos fenómenos puede provocar sobreestimaciones (hasta un 40%) en la evaluación de armónicos para el mismo sistema de distribución estudiado.

Citations (3)


... With regard to the area sites in GIS, which are the layers of land cover of Sofia, the so-called ''polygon topology'' is used. Polygon topologies are useful in analyzing ground connections surfaces (Agüero et al., 2020). They can be presented in tabular form, where the results of the topological criteria for the relationship between the vector data are recorded -intersection of lines at the nodes, overlay of polygon layers, clipping out a subset of polygons with another polygon and other topologic relationships (Harmon et al., 2003). ...

Reference:

A METHODOLOGICAL APPROACH TO THE DEVELOPMENT AND MAPPING OF THE URBAN LAND COVER OF THE CITY OF SOFIA
TOPOLOGY TOOLS FOR NETWORK ANALYSIS ON GIS PLATFORMS
  • Citing Article
  • November 2019

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY

... Some of them have characterized this effect by using EMTP simulation or experimental tests. Recent researches have shown the harmonic attenuation effect of Compact Fluorescent Lamps (CFLs) [5], [6], [7] and [8] among others. Nevertheless, only a few numbers of authors have decided to study this effect over HPS lamps [9]. ...

Partial cancellation of harmonic currents caused by nonlinear residential loads
  • Citing Article
  • January 2005

Informacion Tecnologica

... El primer paso consistió en ensayar el comportamiento de dos tipos de cargas: una con alta distorsión de corriente (THD I del 90%), combinación de computadora y monitor (PC) y una segunda con un THD I relativamente bajo (30%) representada por una lámpara fluorescente (LF), Suárez et al. (2005). De estos ensayos se obtuvieron las amplitudes y ángulos de fase de los componentes armónicos. ...

Cancelación Parcial de Corrientes Armónicas Provocadas por Cargas Residenciales No Lineales
  • Citing Article
  • December 2004