Andrew Evans’s research while affiliated with Mott MacDonald Group and other places

What is this page?


This page lists works of an author who doesn't have a ResearchGate profile or hasn't added the works to their profile yet. It is automatically generated from public (personal) data to further our legitimate goal of comprehensive and accurate scientific recordkeeping. If you are this author and want this page removed, please let us know.

Publications (1)


The influence of nominal stress on wear factors of carbon fibre-reinforced polyetheretherketone (PEEK-OPTIMA (R) Wear Performance) against zirconia toughened alumina (Biolox (R) delta ceramic)
  • Article

June 2014

·

27 Reads

·

22 Citations

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine

Andrew Evans

·

·

Anthony Unsworth

·

Carbon fibre-reinforced polyetheretherketone is an attractive alternative to ultra-high-molecular-weight polyethylene in artificial joints, but little has been published on the influence of stress on the wear factor. We know that in ultra-high-molecular-weight polyethylene, the wear factor reduces as the normal stress increases, which is counter-intuitive but very helpful in the case of non-conforming contacts. In this study, carbon fibre-reinforced polyetheretherketone (PEEK-OPTIMA(®) Wear Performance) has been investigated in a pin-on-plate machine under steady loads and under stresses typical of hip and knee joints. At stresses below about 6 MPa, wear factors are between 10 and a 100 times lower than for ultra-high-molecular-weight polyethylene but at higher stresses the wear factors increase substantially.

Citations (1)


... In the present study, the high presence of carbon oxide on the surface of the implant, both internally and externally, can be observed, which may result in a greater capacity for the mechanical imbrication of the internal connection [27]. Therefore, higher surface energy can be observed, before an imminent difficulty in the rupture between the structures joined through resin cement, which is the case of our study. ...

Reference:

Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant
The influence of nominal stress on wear factors of carbon fibre-reinforced polyetheretherketone (PEEK-OPTIMA (R) Wear Performance) against zirconia toughened alumina (Biolox (R) delta ceramic)
  • Citing Article
  • June 2014

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine