The ICRP Task Group on Internal Dosimetry is developing new Occupational Intakes of Radionuclides (OIR) documents. Application of the Human Respiratory Tract Model (HRTM) requires a review of the lung-to-blood absorption characteristics of inhaled compounds of importance in radiological protection. Where appropriate, material-specific absorption parameter values will be given, and for other compounds, assignments to default Types will be made on current information. Publication of the OIR provides an opportunity for updating the HRTM in the light of experience and new information. The main possibilities under consideration relate to the two main clearance pathways. Recent studies provide important new data on rates of particle transport from the nasal passages, bronchial tree (slow phase) and alveolar region. The review of absorption rates provides a database of parameter values from which consideration can be given to deriving typical values for default Types F, M and S materials, and element-specific rapid dissolution rates.
Content may be subject to copyright.
1
Proposed Updating of the ICRP Human Respiratory Tract Model
Michael Bailey
a*
, Eric Ansoborlo
b
, George Etherington
a
, Demetrio Gregoratto
a
,
Raymond Guilmette
c
, James Marsh
a
, François Paquet
d
, Jennifer Smith
a
a
Health Protection Agency, Radiation Protection Division, Chilton, Oxfordshire,
OX11 0RQ United Kingdom.
b
CEA/DEN/DRCP/CETAMA, VRH-Marcoule, BP17171, 30207 Bagnols sur Cèze,
France.
c
Lovelace Respiratory Research Institute, 2425 Ridgecrest Drive SE Albuquerque, NM
87108, United States of America.
d
IRSN/DS, BP3, 13115 Saint Paul Lez Durance, Cedex, France.
Abstract. The ICRP Task Group on Internal Dosimetry is developing new Occupational Intakes of Radionuclides
documents, which will include revised dose coefficients for inhalation of radionuclides by workers. Application of
the ICRP Human Respiratory Tract Model requires a review of the lung-to-blood absorption characteristics of
inhaled materials of importance in radiological protection. It is planned that, where appropriate, material-specific
absorption parameter values will be given, and for other materials, assignments to default absorption Types will be
made on the basis of current information. Publication of the Occupational Intakes of Radionuclides documents
provides an opportunity for updating the Human Respiratory Tract Model in the light of experience and new
information. The main possibilities under consideration relate to the two main clearance pathways: absorption to
blood and particle transport. The review of absorption rates is providing a database of parameter values from
which consideration can be given to deriving typical values for default Types F, M and S materials, and element-
specific rapid dissolution rates. Important new data on rates of particle transport from the nasal passages, bronchial
tree (slow phase) and alveolar-interstitial region have come from recent human studies, some of which were
conducted to address uncertainties identified by development of the model. These new results, and others, are
being reviewed alongside those available in 1993 when the model was finalised, to propose revisions based on the
best currently-available information. This paper reports on the current status of this work.
KEYWORDS: ICRP; internal dosimetry; inhalation; HRTM.
1. Introduction
The ICRP Publication 66 Human Respiratory Tract Model (HRTM) [1] has been applied to calculate
dose coefficients and bioassay functions for workers and members of the public [2–5]. The ICRP Task
Group on Internal Dosimetry (INDOS) is carrying out a full revision of the worker exposure documents
[2,5] to produce a new set of documents on Occupational Intakes of Radionuclides (OIR) [6].
Application of the HRTM in the OIR requires a review of the lung-to-blood absorption characteristics
of inhaled materials of importance in radiological protection. Where appropriate, material-specific
absorption parameter values will be given, and for other materials, assignments to default Types will be
made, based on current information. The OIR documents will provide new dose coefficients and
bioassay functions, taking into account a number of factors, including new tissue weighting factors [7],
radionuclide decay data, reference computational phantoms of the human body based on medical
tomographic images, the Human Alimentary Tract Model (HATM) [8], and revised systemic models for
many elements. They therefore also provide an opportunity for some refining and updating of the
HRTM in the light of new information and about 15 years’ experience in its use. Suggestions have been
put forward for discussion at recent international workshops on internal dosimetry [9, 10]. This paper
reports on the current status of the work. The main changes now under consideration all relate to
clearance because of the availability of important new information on both major clearance pathways:
absorption to blood and particle transport.
*
Presenting author, E-mail: mike.bailey@hpa.org.uk
2
In the HRTM the respiratory tract is represented by five regions, based on differences in radio-
sensitivity, deposition and clearance (Fig. 1). The extrathoracic (head and neck) airways (ET) are
divided into ET
1
, the anterior nasal passage (front of the nose), and ET
2
, which consists of the posterior
nasal and oral passages, the pharynx and larynx. The thoracic regions (the lungs) are Bronchial (BB:
trachea, generation 0, airway generations 1-8), Bronchiolar (bb: airway generations 9–15), and
Alveolar-Interstitial (AI, the gas exchange region). Lymph nodes are associated with the extrathoracic
and thoracic airways (LN
ET
and LN
TH
respectively). For consistency with the HATM, the oral passage
will not be included in ET
2
as it is now [1]. This does not affect results obtained with the HRTM,
because deposition in ET from air entering the mouth was taken to occur only in the larynx.
Target cells are identified in each region: e.g. the basal cells of the epithelium in both ET regions; basal
and secretory cells in the bronchial epithelium. Reference values of dimensions that define the mass of
tissue containing target cells in each region for dose calculations, are given. They are assumed to be
independent of age and sex.
Figure 1: Respiratory tract regions defined in the HRTM (reference [1], Figure 1)
Reference values of breathing rates (frequency and volume) are recommended for children aged
3 months, 1, 5, 10 and 15 years, and adults, for four levels of exercise: sleep, sitting, light and heavy
exercise, and taking account of both nose- and mouth-breathing. These were combined with habit
survey data to give the reference volumes inhaled per working shift or per day. Deposition of
particulate materials in each region was calculated as functions of particle size for each age group and
exercise level, initially for particles of uniform size. The results were then applied to aerosols with log-
normal particle size distributions, and reference values tabulated as a function of the median size [1].
No changes to target cells, breathing rates or regional deposition of particulate aerosols are envisaged.
3
For gases and vapours deposition in each region is related to their solubility in (and reactivity with)
respiratory tract lining fluids. As for particulate forms of radionuclides, default parameter values are
provided for use in the absence of more specific information. It is proposed that the general defaults
for gases and vapours become 100% total deposition in the respiratory tract: 20% ET
2
, 10% BB,
20% bb and 50% AI (with Type F absorption). This classification is different from that recommended
in Publication 66 [1], but simpler to apply. In particular, no deposition in ET
1
is assumed by default.
The SR-0, -1, -2, classification was found to be unhelpful and will no longer be used.
The HRTM describes several routes of clearance from the respiratory tract, involving three general
processes. Material deposited in ET
1
is assumed to be removed by nose blowing and wiping. In other
regions clearance results from a combination of movement of radionuclides from the respiratory tract
into the blood and hence body fluids (absorption), and movement of particles towards the GI tract and
lymph nodes (particle transport). It is assumed that all clearance rates are independent of age and sex.
2. ABSORPTION TO BLOOD
In the HRTM, absorption is treated as a two-stage process: particle dissolution and uptake into blood
(Fig. 2). It is assumed that absorption rates are the same in all respiratory tract regions except ET
1
,
where none occurs.
Figure 2: Alternative compartment models representing time-dependent absorption to body fluids
(dissolution and uptake). In model (a) a fraction f
r
of the deposit is initially assigned to the
compartment labelled “Rapid dissolution”, and the rest (1– f
r
) of the deposit is initially assigned to the
compartment labelled “Slow dissolution”. In model (b) all the deposit is initially assigned to the
compartment labelled “Particles in initial state”. Material in these compartments in both models is also
cleared by particle transport, and at the same rate, determined by the particle transport model (Fig. 3).
Material in the compartment labelled ‘Bound material’ is not cleared by particle transport at all. For
other symbols see text.
s
b
f
b
s
s
f
b
s
r
(1 – f
b
) s
r
Rapid
dissolution
Slow
dissolution
Body fluids
1 –
f
r
f
r
Deposition Deposition
( a)
Bound material
s
pt
s
b
f
b
s
t
f
b
s
p
Particles in
initial state
Particles in
transformed state
Body fluids
Deposition
( b)
Bound material
(1 – f
b
) s
t
(1 – f
b
) s
p
(1 – f
b
) s
s
4
2.1 Dissolution
Time-dependent dissolution (Fig. 2(a)) is represented by a rapid phase (fraction f
r
dissolving at rate s
r
)
and a slow phase (fraction 1–f
r
dissolving at rate s
s
). A limitation of the system in Fig. 2(a) is that it
can only readily represent an overall fractional dissolution rate that decreases with time. To overcome
this, the HRTM uses an equivalent system with the same number of variables, but which gives greater
flexibility, shown in Fig. 2(b). In this, the material deposited in the respiratory tract is assigned to
compartments labelled “Particles in initial state” in which it dissolves at a constant rate s
p
. Material is
simultaneously transferred (at a constant rate s
pt
) to a corresponding compartment labelled “Particles in
transformed state” in which it has a different dissolution rate, s
t
. The initial dissolution rate is
approximately s
p
and the final dissolution rate is approximately s
t
. Thus with suitable choice of
parameters, including s
t
> s
p
, an increasing dissolution rate can be represented. If the dissolution rate
decreases with time, as is usually the case, either system could be used, and would give the same
results, with the following values:
s
p
= s
s
+ f
r
(s
r
s
s
); s
pt
= (1 – f
r
) (s
r
s
s
); s
t
= s
s
The system shown in Fig. 2(b) is that formally used in the HRTM, in that the default absorption
parameter values (Table 1) are specified in terms of s
p
, s
pt
and s
t
, rather than f
r
, s
r
and s
s
. However, the
system in Fig. 2(a) is much simpler to present, and often has advantages. In particular, it is generally
more straightforward to estimate its parameter values from experimental data [11]. In practice it has
become much more widely used. It is therefore proposed that default absorption parameter values
should be specified in terms of f
r
, s
r
and s
s
.
Table 1: Default absorption parameter values for Type F, M, and S materials [1]. The model values s
p
,
s
pt
and s
t
in this table are reference values i.e., the recommended default values for use in the model
Absorption Type F(fast) M (moderate) S (slow)
Model parameters:
Initial dissolution rate (d
-1
) s
p
100 10 0.1
Transformation rate (d
-1
) s
pt
0 90 100
Final dissolution rate (d
-1
) s
t
- 0.005 0.0001
Fraction dissolved rapidly f
r
1 0.1 0.001
Rapid dissolution rate (d
-1
) (approximate) s
r
100 100 100
Slow dissolution rate (d
-1
) (approximate) s
s
- 0.005 0.0001
Fraction to bound state f
b
0 0 0
Uptake rate from bound state (d
-1
) s
b
- - -
2.2 Uptake to blood
Time-dependent uptake is represented by a fraction (f
b
) of the dissociated material retained in a
‘bound’ state, from which it goes to blood at a rate s
b
, while the rest goes instantaneously (Fig. 2). It is
assumed by default that f
b
= 0. It is expected that since the bound state applies to dissociated material,
its characteristics, like that of the systemic model, will usually be specific to each element. Application
of the HRTM in the OIR documents requires a review for each element of the absorption
characteristics of inhaled materials relevant to radiological protection. One important objective of the
reviews is to determine bound state parameter values for each element. Initial assessments made for
some elements [11] suggest that binding needs to be considered for americium and plutonium but not
for caesium or uranium.
5
2.3 Material specific parameter values
Where the reviews demonstrate that there are consistent in vivo results for a material, specific
absorption parameter values may be recommended for it. Reviews have been completed on about
15 elements. Suitable information was found to enable specific parameter values to be proposed for
about 20 materials, which are mostly forms of thorium and uranium. It is likely that there will be a few
more such materials for each of the other important actinides that remained to be reviewed. Where
suitable information is not available, or where the material shows a range of behaviour too wide to
enable specific values to be chosen, materials will be assigned to default Types using current
information. Criteria to assign materials to Types F, M or S on the basis of experimental data [3, 11]
are defined in terms of the fraction of the deposit absorbed into blood in a given time:
Assign to Type F (rather than Type M) if there is more absorption by 30 d after intake than for
a hypothetical material with an absorption rate corresponding to a half-time of 10 d under identical
conditions.
Assign to Type S (rather than Type M) if there is less absorption by 180 d than for a material
with absorption half-time of 700 d.
These criteria may need to be revised if the default parameter values are themselves revised (see
below).
2.4 Default parameter values
The current default values for Types F, M and S [1, 2] were not based on reviews of experimental data
but on comparison with particle transport rates. The value of 100 d
–1
for the rapid dissolution rate s
r
was chosen to equal the particle clearance rate from the nose to the throat. Hence for Type F about half
the material deposited in ET
2
is absorbed into blood and the rest swallowed. The slow dissolution rate
for Type S of 10
–4
d
–1
was chosen to equal the slowest particle transport rate from the AI region to the
GI tract, to ensure that there was some long term lung retention. Type M values were simply chosen to
be intermediate between the two. Consideration is now being given to selecting values that are more
representative of materials that are generally considered to clear at ‘fast’, ‘moderate’ or ‘slow’ rates. In
the review of each element, specific parameter values (from both in vivo and in vitro studies) are noted
in the text of the draft OIR inhalation sections where available in papers or derived by the reviewer.
About 70 sets of parameter values are now available. For each Absorption Type (F, M and S), values
were collated for each parameter (f
r
, s
r
and s
s
), and geometric means calculated as central values
because of the wide ranges observed. Although material-specific parameter values will only be
recommended based on in vivo studies, in vitro results were included in this survey to provide a larger
and broader sample. Present observations are as follows:
Rapid fraction f
r
: for Type F, most values are close to the current default value of 1.0; for Types M and
S, central values are higher (about 0.2 and 0.01, respectively) than current defaults (0.1 and 0.001).
Rapid dissolution rate, s
r
: For Types F, M and S, central values are about 15 d
–1
, 1 d
–1
and 3 d
–1
,
respectively, all much lower than the current default of 100 d
–1
. However, these findings are heavily
influenced by results for a few elements. Consideration is being given to element-specific values of s
r
.
Slow dissolution rate, s
s
: For Types M and S, central values are about 0.003 d
–1
and 8 10
–5
respectively, similar to the current default values of 0.005 d
–1
and 10
–4
d
–1
.
Thus the data currently available suggest larger typical rapid fractions for Types M and S materials but
with lower rapid dissolution rates than current default values. This would have the effect of shifting
the site of rapid absorption from the nose to the lungs. The rates for the slow fractions seem
reasonable. However, further information is expected from the reviews of those elements that have yet
to be completed.
6
3. PARTICLE TRANSPORT
The HRTM clearance model provides particle transport clearance rates from each compartment, which
apply to all materials (Fig. 3). New studies enable more reliable parameter values to be chosen for the
extrathoracic airways (ET); bronchial (BB); bronchiolar (bb) and AI regions.
Figure 3: Compartment model representing time-dependent particle transport from each respiratory
tract region in the HRTM. Rates shown alongside arrows are reference values in units of d
–1
. It is
assumed that (i) 0.05% of material deposited in region ET
2
is retained in its wall (ET
seq
); (ii) the
fraction of the deposit in BB and bb that is cleared slowly (BB
2
and bb
2
) depends on particle size, and
the fraction retained in the airway wall (BB
seq
and bb
seq
) is 0.7% at all sizes; (iii) the AI deposit is
divided between AI
1
, AI
2
and AI
3
in the ratio 0.3:0.6:0.1. This model describes the retention and
clearance of an insoluble material. There is generally simultaneous absorption to blood of material
from all the compartments except ET
1
.
3.1 Particle transport: extrathoracic airways
The HRTM assumes that of material deposited in the ET airways, about 50% deposits in ET
1
(see
Fig. 1), which is cleared by nose blowing at a rate of 1 d
–1
, and the rest deposits in ET
2
, which clears to
the GI tract at a rate of 100 d
–1
. However, there was little information available to quantify clearance
from ET
1
: indeed there were remarkably few experimental studies of the clearance from the nose of
particles deposited by inhalation [1]. In experiments intended to address this [12], nine subjects
inhaled 3-µm aerodynamic diameter (d
ae
) radiolabelled insoluble particles naturally through the nose
while sitting at rest. Smaller groups inhaled 1.5- or 6-µm d
ae
particles at rest and 3- or 6-µm d
ae
particles while performing light exercise. Retention in the nasal airways and lungs, and clearance by
voluntary nose blowing were followed for about 2 days by gamma spectrometry. Preliminary analysis
of the results [10] indicated that for 1–6 µm particles, only about 15% of the material deposited in ET
deposits in ET
1
and is cleared by nose blowing (in about a day); about 60% deposits in ET
1
and is
cleared to the GI tract (via ET
2
) on a time-scale of hours to days, and the remaining 25% deposits in
ET
2
and is cleared to the gastro-intestinal (GI) tract in about 10 minutes. Detailed analysis is now in
progress. Application of the results would in many cases increase dose coefficients, because of the
transfer from ET
1
to ET
2
and hence greater systemic uptake in ET
2
and the GI tract, but not greatly.
The results also have important implications for interpretation of faecal samples: a considerably larger
fraction of the material deposited in the nose (which is typically about 50% of the material inhaled) is
cleared through the GI tract than is assumed in the HRTM [13].
Extrathoracic
LN
ET
ET
1
ET
2
0.001
Environment
GI tractET
seq
1
100
Thoracic
LN
TH
0.01
BB
seq
BB
2
BB
1
bb
seq
0.01
bb
2
bb
1
AI
3
AI
2
AI
1
0.001 0.02
0.0001
0.00002
2
10
0.03
0.03
Anterior
nasal
N
aso-
oropharynx/
larynx
Bronchi
Bronchioles
Alveolar
interstitial
7
3.2 Particle transport: bronchial and bronchiolar airways
3.2.1 Slow clearance
The HRTM includes a slow phase of clearance of particles deposited in the BB and bb regions
(Fig. 3). It is based mainly on the results of experiments in which volunteers inhaled particles
administered as a ‘shallow bolus’ i.e., a small volume (~50 cm
3
) of aerosol at the end of each breath,
to deposit them in the major airways [1, 14]. A two-component exponential function was fit to the
lung retention data, and the intercept of the slower phase taken to be the ‘slow-cleared fraction’. This
fraction was considered to show a better correlation with particle geometric diameter, d
p
than with d
ae
[1, 14]. The HRTM assumes that the slow-cleared fraction of particles deposited in BB and in bb (f
s
) is
0.5 for d
p
2.5 μm, and decreases for larger particles: f
s
= 0.5 exp(–0.63(d
p
–2.5)) for d
p
> 2.5 μm.
Its inclusion in the HRTM has a significant effect on inhalation doses for some important
radionuclides [15], but was controversial and further experiments have been carried out. In particular,
in a series of experiments large (6-μm d
ae
) particles were inhaled extremely slowly [16, 17].
Theoretically most particles should deposit in the bronchioles. Retention at 24 hours was much greater
than predicted AI deposition, supporting the concept of slow clearance in the bronchial tree, but the
results suggest that slow clearance occurs mainly in the bronchioles, rather than in the bronchi, and
with a clearance half-time of a few days [16] compared to the HRTM assumption of about 20 days.
The effect of d
p
was investigated directly, by administering particles with the same d
ae
, and hence the
same lung deposition pattern, but different densities and so different values of d
p
(d
ae
d
p
√ρ where ρ is
the particle density) [17]. Volunteers inhaled 6-µm d
ae
polystyrene (PSL) or Teflon particles. Because
the density of Teflon is higher (2.13 vs. 1.05 g cm
–3
), d
p
is smaller (4.5 versus 6.1 µm), and f
s
is greater
(14% versus 5%). However, retention of the two particles was similar in each subject.
More recent studies [18, 19] tested these alternative hypotheses more critically, by (i) administering
particles with the same d
ae
, but with a greater difference in densities, (ii) using the shallow bolus
technique to minimise alveolar deposition; (iii) administering the two particles simultaneously, to
ensure that deposition and clearance took place under the same conditions. In the first study [18]
volunteers inhaled shallow boluses containing 5-µm d
ae
PSL and gold (ρ = 19.3 g cm
–3
) particles.
Corresponding d
p
are about 5 and 1.2 μm and values of f
s
about 10% and 50% respectively. Hence
according to the HRTM, lung retention of the gold should be much greater than that of the PSL.
However, no significant difference was observed between them in any subject. In the second study
[19] volunteers inhaled 8-µm d
ae
PSL and gold particles. Corresponding d
p
are about 8 and 1.8 μm and
f
s
about 2% and 50% respectively. The results were more variable than for the 5-µm particles. For one
subject retention was very similar for the two materials. For the others, retention was greater for PSL
than for gold, the opposite of the HRTM prediction.
The results of the recent studies are thus inconsistent with the dependence of f
s
on d
p
assumed in the
HRTM. The most likely explanation seems to be that the inferred dependence on d
p
rather than d
ae
was
fortuitous, resulting from scatter in the data. It should be noted that it was based mainly on
measurements made with relatively large particles (d
p
or d
ae
>4 µm), and there were only a few such
measurements available at the time. Instead most recent studies suggest that it is related to the site of
deposition, with slow clearance mainly in smaller airways. A review is in progress of the information
on which the HRTM was based along with the results of the more recent studies to try to develop a
model consistent with all the available data.
3.2.2 Sequestration in the airway walls
As noted in the caption to Fig. 3, the fraction of particles deposited in the BB and bb regions retained
in the airway wall (BB
seq
and bb
seq
) is 0.7% at all sizes, and this material clears to lymph nodes at a
rate of 0.01 d
–1
. When the HRTM was finalised the phenomenon had only been well quantified by
Patrick and colleagues [1, 20], who followed retention of activity after deposition of radiolabelled
particles onto the distal trachea of rats. Subsequently, Takahashi et al [21] conducted similar
experiments, instilling
133
Ba-labelled BaSO
4
onto the distal trachea of rabbits, dogs and monkeys. The
8
amounts retained 1 week after injection were 0.145%, 0.044% and 0.043% of the injected amount
respectively. These are far lower than found in rats, suggesting inter-species differences. The values
for dogs and monkeys are close to those chosen in the HRTM for retention of particles in the wall of
the nasal epithelium, which was based on results for several different materials in several species. On
that basis it is proposed that values for both the retained fractions and clearance rates from BB and bb
to LN
TH
should be those selected in the HRTM for the nasal epithelium, i.e., 0.05% and 0.001 d
–1
. This
is likely to have little effect on doses or bioassay, but means that the model will assume less transfer to
LN
TH
from BB and bb, and so more transfer from the AI region, to provide the ratio of lung to LN
TH
contents observed in autopsy studies [1].
3.3 Particle transport: alveolar-interstitial (AI) region.
In the HRTM
the AI region is represented by three compartments: AI
1
, AI
2
and AI
3
, which mainly
clear to the GI tract via the bronchial tree at rates of 0.02, 0.001 and 0.0001 d
–1
respectively
(approximate half times 35, 700 and 7000 d) (Fig. 3). Human lung clearance had been quantified in
experimental studies up to about a year after inhalation [1]. Lung retention of insoluble particles over
this time typically follows a two-component exponential function: about 30% with a half-time of about
30 d, and the rest a half-time of several hundred days, giving about 50% retention at 300 d. This
information was used to define the parameter values for AI
1
. Measurements of activity in the chest
after occupational exposure, and of activity in the lungs at autopsy, indicate that some material can be
retained in the lungs for decades. However, the results were not used to set parameter values for AI
2
and AI
3
quantitatively, because it was possible that the published in vivo studies represented unusually
slow lung clearance. It was noted [1] that: “The fraction of the AI deposit that goes to AI
3
(a
3
) is not
easily quantified. Since only 50% IAD is retained at 300 d, a
3
is less than 0.5. Since there is
measurable thoracic retention at 5000 d after intake in some subjects (Figure E.10), a
3
is likely to be at
least a few percent of the IAD. As a rounded value it is assumed that a
3
= 0.1, and, hence, by
difference, that a
2
= 0.6.”
A new study [22] seems to provide better information than that available previously, because a group
of workers had a simultaneous brief inhalation exposure to particles containing
60
Co, and most (seven)
have been followed for about 15 years. Thus it is reasonable to assume that they are representative of
nuclear industry workers. They all show much slower clearance than the HRTM predicts, and are also
consistent with most of the other studies with measurements beyond 2000 days considered in ICRP
Publication 66 [1]. A review of long-term lung retention data is therefore in progress, to inform
revision of the parameter values for the AI region [23]. Two other major relevant studies have been
identified that were published since the HRTM was finalised.
Philipson et al [24] followed lung retention in 10 subjects for about 3 years after inhalation of
195
Au-
labelled Teflon particles. The duration of this study was about three times longer, and it seems likely
that there was less leakage of the radioactive label from the test particles, than for the experiments
available when the HRTM was developed. It therefore provides more reliable information, especially
at long times after intake. The results also suggest that the HRTM underestimates long-term lung
retention of insoluble particles. For the seven non-smokers and ex-smokers, retention at 900 d was
about 60% of that at 7 d (about 70% for smokers), compared to about 30% predicted by the HRTM.
Kuempel et al [25] developed a physiologically based kinetic model to predict long-term lung and
lymph node particle retention in coal miners. The model (Fig. 4) has separate alveolar and interstitial
compartments, reflecting the biological structure. It is considered that there is macrophage-mediated
clearance from the alveolar compartment to the bronchiolar airways, and that particles that escape that
mechanism penetrate to the interstitium, from which there is slow clearance to the hilar lymph nodes.
The model was applied to a group of U.S. coal miners for whom there were exposure histories on
which to assess particle mass deposition rates, and autopsy measurements of lung dust concentration
(and in about 50% of cases lymph node concentration as well). The model was considered to be the
simplest consistent with the data, and no evidence was found for impaired clearance at high lung
loadings, over the range observed. The authors noted that the HRTM underestimated lung retention in
the miners by about a factor of four.
9
Figure 4: Kuempel et al [25] alveolar-interstitial model. For definition of symbols see text.
Retention as a function of time A(t) of the initial alveolar deposit A(0) can be expressed as:
A(t) = A(0) [L
seq
+ (1 – L
seq
) exp
mt
]
where L
seq
= m
I
/(m
T
+ m
I
) is the fraction sequestered in the interstitial region and lymph nodes; m
I
and
m
T
are the rates of transfer from the alveolar region to the interstitial region and the bronchioles
respectively; and m = m
T
+ m
I
is the overall clearance rate from the alveolar region. For the optimised
fit made by Kuempel et al. to the miner data, L
seq
= 0.32 and m = 0.0015 d
–1
. It was found [23] that
although this model has fewer parameters than the HRTM AI model, it could adequately represent
long-term lung retention in the
60
Co cases [22], although with different parameter values. It can also
provide an adequate overall fit to the experimental data on which the HRTM [1] parameter values for
AI
1
were based, together with the Philipson et al [23] and Davis et al [22] data. In that case L
seq
is
almost entirely determined by the long term
60
Co cases, and is approximately 0.6. The model is being
tested on appropriate cases of accidental inhalation of insoluble materials with long-term lung
retention data. Subject to satisfactory validation, it may well be proposed to replace the current HRTM
representation of retention in the AI region, being both simpler and biologically more realistic.
4. Conclusions
The development of the OIR documents will include new inhalation dose coefficients for workers, and
provides an opportunity to update the HRTM. A comprehensive review of the absorption
characteristics of inhaled materials relevant to radiological protection is being carried out to apply the
HRTM in the OIR documents. Where there are consistent in vivo results, material-specific absorption
parameter values will be recommended, and this is likely to include about 25 materials, mainly forms
of thorium, uranium and transuranic elements. The review also provides a compilation of information
to enable reconsideration of the default absorption parameter values to be made. The data presently
available suggest that lower values of rapid dissolution rate for all three Types, and higher values of
the rapid fraction for Types M and S would be more appropriate than the present values. New
information is also available which allows more realistic modelling of particle transport from the nasal
passage, bronchial tree and alveolar region than in the current version of the HRTM.
REFERENCES
[1] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Human
Respiratory Tract Model for Radiological Protection, ICRP Publication 66, Annals of the ICRP
24(1–3), Elsevier Science Ltd., Oxford (1994).
[2] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Dose Coefficients
for Intakes of Radionuclides by Workers, ICRP Publication 68, Annals of the ICRP 24(4),
Elsevier Science Ltd., Oxford (1994).
Alveolar
region
Interstitial
region
Hilar
lymph nodes
Bronchiolar
region
m
I m
LN
m
T
Deposition
10
[3] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Age-dependent
Doses to Members of the Public from Intake of Radionuclides: Part 4 Inhalation Dose
Coefficients, ICRP Publication 71, Annals of the ICRP 25(3–4), Elsevier Science Ltd., Oxford
(1995).
[4] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Age-dependent
Doses to Members of the Public from Intake of Radionuclides: Part 5 Compilation of Ingestion
and Inhalation Dose Coefficients, ICRP Publication 72, Annals of the ICRP 26(1), Elsevier
Science Ltd., Oxford (1996).
[5] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Individual
Monitoring for Internal Exposure of Workers: Replacement of ICRP Publication 54, ICRP
Publication 78, Annals of the ICRP, 27 (3/4). Elsevier Science Ltd., Oxford (1997).
[6] STATHER, J.W. The work of Committee 2 of ICRP on internal dosimetry. Radiat. Prot. Dosim.
127, 8–11 (2007).
[7] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, The 2007
Recommendations of the International Commission on Radiological Protection, ICRP
Publication 103, Annals of the ICRP, 37 (2–4) Elsevier Science Ltd., Oxford (2007).
[8] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Human
Alimentary tract Model for Radiological Protection, ICRP Publication 100, Annals of the ICRP,
36 (1/2) Elsevier Science Ltd., Oxford (2006).
[9] BAILEY, M.R., et al., Practical application of the ICRP Human Respiratory Tract Model.
Radiat. Prot. Dosim. 105, 71–76 (2003).
[10] BAILEY, M.R., et al., Updating the ICRP Human Respiratory Tract Model, Radiat. Prot.
Dosim. 127, 31–34 (2007).
[11] INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION, Guide for the
Practical Application of the ICRP Human Respiratory Tract Model, Supporting Guidance 3,
Annals of the ICRP 32 (1–2), Elsevier Science Ltd., Oxford (2002).
[12] SMITH, J.R.H., et al., A study of aerosol deposition and clearance from the human nasal
passage, Ann occup. Hyg 46 (Suppl. 1) 309–313 (2002).
[13] SMITH, J.R.H. Implications of human nasal clearance studies for the interpretation of nose
blow and bioassay sample measurements, Radiat. Prot. Dosim. 105, 190–122 (2003).
[14] STAHLHOFEN, W., et al., Investigations of retention of inhaled particles in the human
bronchial tree, Radiat. Prot. Dosim. 60, 311–319 (1995).
[15] BAILEY, M.R., et al., Implications of airway retention for radiation doses from inhaled
radionuclides, J. Aerosol Med. 8, 373–390 (1995).
[16] FALK, R., et al., Assessment of long-term bronchiolar clearance of particles from
measurements of lung retention and theoretical estimates of regional deposition, Exp. Lung Res.
25, 495–516 (1999).
[17] PHILIPSON, K., et al., Does lung retention of inhaled particles depend on their geometric
diameter? Exp. Lung Res. 26, 437–455 (2000).
[18] SMITH, J.R.H., et al., Effect of particle size on slow particle clearance from the bronchial tree,
Exp. Lung Res. 34, 287–312 (2008).
[19] SMITH, J.R.H., et al., Further study of the effect of particle size on slow particle clearance from
the bronchial tree. Radiat. Prot. Dosim. 127, 35–39 (2007).
[20] TAKAHASHI, S. and PATRICK, G., Long-term retention of
133
Ba in the rat trachea following
local administration as barium sulfate particles. Radiat. Res., 110, 321–328 (1987).
[21] TAKAHASHI, S., et al., Retention of
133
Ba in the trachea of rabbits, dogs and monkeys
following local administration of
133
BaSO
4
particles. Inhalation Toxicology 5, 265–273 (1993).
[22] DAVIS, K., et al., Assessment of intakes and doses to workers followed for 15 years after
accidental inhalation of
60
Co. Health Phys. 92, 332–344 (2007).
[23] GREGORATTO, D., et al., Particle retention in the alveolar-interstitial region: proposed
changes to the Human Respiratory Tract Model (in preparation).
[24] PHILIPSON, K., et al., Long-term lung clearance of
195
Au-labelled Teflon particles in humans.
Exp. Lung Res. 22, 65–83 (1996).
[25] Kuempel E.D. et al., A biomathematical model of particle clearance and retention in the lungs
of coal miners. Regul. Toxicol. Pharmacol. 34, 69–87 (2001).
... To estimate the deposition efficiency and flux of PM-bound 6-PPDQ in the human respiratory system, we adopted International Commission on Radiological Protection (ICRP) models; detailed equations are shown in the SI. 26,27 Statistical analysis (e.g., Mann−Whitney U test) was performed using SPSS 24.0 (IBM, USA). (Table S3). ...
... More precisely, the simplified models raised by ICRP were adopted to estimate the lung deposition efficiency and fluxes of inhaled 6-PPDQ. 26,27 The advantages of the ICRP model mainly involve the following: (1) It is suitable for a wide cohort population including occupational workers. (2) It fully considers the human respiratory exchange ratios under diverse environmental conditions (e.g., working or daily life). ...
... To better understand the effects of air pollution exposure on human health, it is crucial to determine how much of the inhaled pollutants that are deposited in the respiratory tract. A common practice for assessing the respiratory tract deposition (RTD) of pollutants is to either apply numerical (in silico) or semi-empirical models (e.g., International Commission of Radiological Protection [15] and Multiple-Path Particle Dosimetry models [16]) or to perform laboratory and real-life in situ experiments involving human subject (e.g., RESPI [17], MERDOC [18], single breath measurement [19]). Additionally, other prior approaches (ab initio) [20] were used in some studies, however, the assumptions made (i.e., all inhaled particles are deposited) make such methods more susceptible to large uncertainties. ...
Article
Full-text available
Background Exposure to air pollutants is one of the major environmental health risks faced by populations globally. Information about inhaled particle deposition dose is crucial in establishing the dose–response function for assessing health-related effects due to exposure to air pollution. Objective This study aims to quantify the respiratory tract deposition (RTD) of equivalent black carbon (BC) particles in healthy young adults during a real-world commuting scenario, analyze factors affecting RTD of BC, and provide key parameters for the assessment of RTD. Methods A novel in situ method was applied to experimentally determine the RTD of BC particles among subjects in the highly polluted megacity of Metro Manila, Philippines. Exposure measurements were made for 40 volunteers during public transport and walking. Results The observed BC exposure concentration was up to 17-times higher than in developed regions. The deposition dose rate (DDR) of BC was up to 3 times higher during commute inside a public transport compared to walking (11.6 versus 4.4 μg hr⁻¹, respectively). This is twice higher than reported in similar studies. The average BC mass deposition fraction (DF) was found to be 43 ± 16%, which can in large be described by individual factors and does not depend on gender. Conclusions Commuting by open-sided public transport, commonly used in developing regions, poses a significant health risk due to acquiring extremely high doses of carcinogenic traffic-related pollutants. There is an urgent need to drastically update air pollution mitigation strategies for reduction of dangerously high emissions of BC in urban setting in developing regions. The presented mobile measurement set-up to determine respiratory tract deposition dose is a practical and cost-effective tool that can be used to investigate respiratory deposition in challenging environments.
... This is difficult to constrain as particle removal depends on the deposition site within the lungs and clearance mechanisms involved (mucociliary transport, uptake by phagocytic cells, in situ dissolution, etc.). These processes operate on the order of hours to days and months (Bailey et al., 2007;Morgan et al., 2004;Gehr et al., 1990). It has also been argued that the shortterm toxic effect of particles that release ions at a fast rate could be identical to those of the dissolved ions (Studer et al., 2010), whereas, for particles that release ions at a slow rate, there is a greater likelihood that the particles will be the cause of the observed adverse effects (Oberd€ orster, 2000). ...
Article
Freshly erupted volcanic ash contains a range of soluble elements, some of which can generate harmful effects in living cells and are considered potentially toxic elements (PTEs). This work investigates the leaching dynamics of ash-associated PTEs in order to optimize a method for volcanic ash respiratory hazard assessment. Using three pristine (unaffected by precipitation) ash samples, we quantify the release of PTEs (Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, V, Zn) and major cations typical of ash leachates (Mg, Na, Ca, K) in multiple simulated lung fluid (SLF) preparations and under varying experimental parameters (contact time and solid to liquid ratio). Data are compared to a standard water leach (WL) to ascertain whether the WL can be used as a simple proxy for SLF leaching. The main findings are: PTE concentrations reach steady-state dissolution by 24 h, and a relatively short contact time (10 min) approximates maximum dissolution; PTE dissolution is comparatively stable at low solid to liquid ratios (1:100 to 1:1000); inclusion of commonly used macromolecules has element-specific effects, and addition of a lung surfactant has little impact on extraction efficiency. These observations indicate that a WL can be used to approximate lung bioaccessible PTEs in an eruption response situation. This is a useful step towards standardizing in vitro methods to determine the soluble-element hazard from inhaled ash.
... At the other extremity are whole lung models which consider the lung to be a network of interconnected branching channels with varying dimensions. Such whole lung models include semi-empirical regional compartment models [9], one-dimensional trumpet models [10,11] and various mechanistic models [5]. A common requirement in all whole lung models is an assumption of the lung morphometry. ...
Preprint
The primary mode of respiratory virus transmission is by means of virus-laden aerosols. The aerosols are inhaled into the respiratory tract and deposited in the mucosa, where the virus may interact with the epithelial tissue causing infection. Transport of virus within the respiratory tract and clearance from the lungs, as such, becomes extremely important. This phenomena is mathematically modelled using a coupled model of aerosol transport and virus transport within a Weibel-like idealisation of the lung geometry. The analysis is carried out in a dimensionless manner and the results are presented in terms of various dimensionless parameters. It is observed that the main factor determining virus transport and clearance from the lungs is the region where the virus-laden aerosols are deposited within the lungs. Viruses deposited in the upper respiratory tract are cleared out of the lung relatively faster due to the impact of mucociliary clearance. Viruses deposited in the deep lung are cleared much slowly due to absence of mucociliary clearance. Deep lung deposition is observed to take place for a specific range of aerosol sizes. Slower breathing and deep breaths is observed to promote deep lung deposition. Slower breathing and larger mucus clearance is also observed to enhance virus clearance from the upper respiratory tract. It is further observed that virus clearance from the deep lung can only be enhanced by increasing virus diffusivity. This enhancement is, however, not substantial. It is, thus, essential to eliminate the situations which promote deep lung deposition of the viruses.
... However, for special cases, uncertainties can be very important to judge the reliability and the potential range of the dose and risk estimates for real individuals and situations. A quantitative analysis of internal dose can help to guide regulators in setting appropriate limits on intakes (Görtz et al. 2000), to guide national and international organizations to invest scientific efforts for updating the models and dose coefficients (Bailey et al. 2007), and to provide dose uncertainties for occupational workers (Henrichs 2007). Quantification of uncertainties can support the reliability of dose coefficients as regulatory dose limits and constraints (Puncher et al. 2012). ...
Article
Full-text available
Radioactive cerium and other lanthanides can be transported through the aquatic system into foodstuffs and then be incorporated by humans. Information on the uncertainty of reported dose coefficients for exposed members of the public is then needed for risk analysis. In this study, uncertainties of dose coefficients due to the ingestion of the radionuclides 141Ce and 144Ce were estimated. According to the schema of internal dose calculation, a general statistical method based on the propagation of uncertainty was developed. The method takes into account the uncertainties contributed by the biokinetic models and by the so-called S values. These S-values were derived by using Monte Carlo radiation transport simulations with five adult non-reference voxel computational phantoms that have been developed at Helmholtz Zentrum München, Germany. Random and Latin hypercube sampling techniques were applied to sample parameters of biokinetic models and S values. The uncertainty factors, expressed as the square root of the 97.5th and 2.5th percentile ratios, for organ equivalent dose coefficients of 141Ce were found to be in the range of 1.2-5.1 and for 144Ce in the range of 1.2-7.4. The uncertainty factor of the detriment-weighted dose coefficient for 141Ce is 2.5 and for 144Ce 3.9. It is concluded that a general statistical method for calculating the uncertainty of dose coefficients was developed and applied to the lanthanide cerium. The dose uncertainties obtained provide improved dose coefficients for radiation risk analysis of humans. Furthermore, these uncertainties can be used to identify those parameters most important in internal dose calculations by applying sensitivity analyses.
... The ICRP 66 model includes the dosimetry of such inhaled radioactive particles which we can consider as ultrafine particles releasing alpha particles and getting deposited in the lung upon inhalation. Whereas, the ICRP 130 model describes about additional clearance mechanisms of radon and thoron progenies including transport into the blood from five different parts of the respiratory systems(Bailey et al. 2007). Hence, ICRP 130 model is more updated and discusses about the systemic clearance upon radon/thoron progenies inhalation. ...
Article
Full-text available
Purpose: Natural radiation is the major source of human exposure to ionizing radiation. About 52% of the total dose received from the high natural background radiations (HNBR) areas are due to inhalation dose from radon (222Rn)/thoron (220Rn) and their progenies. Hence, we reviewed the biological effects of 222Rn/220Rn and their progenies on lung tissue, and the possible role of lung stem cells in salvaging the damage caused by 222Rn/220Rn and their progenies. Materials and method: We have extensively reviewed articles among several hits obtained in PubMed, Scopus, and Elsevier databases with keywords 'Radon/Thoron' OR Thoron progeny/Radon progeny OR 'Thoron/Radon inhalation and lungs', and proceed for further analysis. Also, databases related to oxidative damage to lung stem cells by radiation and the repair mechanisms involved by the lung stem cells were also included. Results: Based on the existing epidemiological data on radon in residential buildings, we found that evidence exists on the association of radon induced lung carcinogenesis, but the data regarding the role of thoron induced lung damage is very limited and inconclusive. We also found that limited information has been provided based on ecological designs, leading to poor documentation of health statistics, in particular, organ-specific cancer rates. Finally, we tried to elucidate the possible mechanisms of lung injury induced by thoron inhalation and the probable role of lung stem cell toward the redemption of such oxidative damages. Conclusion: Existing epidemiological data on thoron inhalation and associated health outcomes are limited and inconclusive. Further, in vivo experiments, with respect to radon/thoron inhalation dose rate ranges corresponding to the HNBR areas will be helpful in understanding the cellular and molecular effects.
Article
Full-text available
Respiratory toxicology remains a major research area in the 21st century since current scenario of airborne viral infection transmission and pollutant inhalation is expected to raise the annual morbidity beyond 2 million. Clinical and epidemiological research connecting human exposure to air contaminants to understand adverse pulmonary health outcomes is, therefore, an immediate subject of human health assessment. Important observations in defining systemic effects of environmental contaminants on inhalation metabolic dysfunction, liver health, and gastrointestinal tract have been well explored with in vivo models. In this review, a framework is provided, a paradigm is established about inhalation toxicity testing in vitro, and a brief overview of breathing Lungs‐on‐Chip (LoC) as design concepts is given. The optimized bioengineering approaches and microfluidics with their fundamental pros, and cons are presented. There are different strategies that researchers apply to inhalation toxicity studies to assess a variety of inhalable substances and relevant LoC approaches. A case study from published literature and frame arguments about reproducibility as well as in vitro/in vivo correlations are discussed. Finally, the opportunities and challenges in soft robotics, systems inhalation toxicology approach integrating bioengineering, machine learning, and artificial intelligence to address a multitude model for future toxicology are discussed. The development of breathing human lungs‐on‐chip brought about the advent of disrupting experimental strategies in inhalation toxicology. In this review, the recent development is explored in the field and future recommendations are provided to advance the in vitro inhalation toxicology integrating emerging air–liquid interface design, innovative soft robotics, and bioMEMS technologies.
Article
Full-text available
To regulate the safety protocols in nuclear facilities, radioactive aerosols have been extensively researched to understand their health impacts. However, most measured particle-size distributions remain at low resolutions, with the particle sizes ranging from nanometer to micrometer. This study combines the high-resolution detection of 500 size classes, ranging from 6 nm–10 μm, for aerodynamic diameter distributions, with a regional lung deposition calculation. We applied the new approach to characterize particle-size distributions of aerosols generated during the plasma arc cutting of simulated non-radioactive steel alloy wastes. The high-resolution measured data were used to calculate the deposition ratios of the aerosols in different lung regions. The deposition ratios in the alveolar sacs contained the dominant particle sizes ranging from 0.01–0.1 μm. We determined the distribution of various metals using different vapor pressures of the alloying components and analyzed the uncertainties of lung deposition calculations using the low-resolution aerodynamic diameter data simultaneously. In high-resolution data, the changes in aerosols that can penetrate the blood system were better captured, correcting their potential risks by a maximum of 42%. The combined calculations can aid the enhancement of high-resolution measuring equipment to effectively manage radiation safety in nuclear facilities.
Article
Particle-bound pollutants can pose a health risk to humans. Inhalation exposure evaluated by total contaminant concentrations significantly overestimates the potential risk. To assess the risk more accurately, bioavailability, which is the fraction that enters into the systemic circulation, should be considered. Researchers have replaced bioavailability by bioaccessibility due to the rapid and cost-efficient measurement for the latter, especially for assessment by oral ingestion. However, contaminants in particulates have different behavior when inhaled than when orally ingested. Some of the contaminants are exhaled along with exhalation, and others are deposited in the lung with the particulates. In addition, a fraction of the contaminants is released into the lung fluid and absorbed by the lung, and another fraction enters systemic circulation under the action of cell phagocytosis on particulates. Even if the release fraction, i.e., release bioaccessibility, is considered, the measurement faces many challenges. The present study highlights the factors influencing release bioaccessibility and the incorporation of inhalation bioaccessibility into the risk assessment of inhaled contaminants. Currently, there are three types of extraction techniques for simulated human lung fluids, including simple chemical solutions, sequential extraction techniques, and physiologically based techniques. The last technique generally uses three kinds of solution: Gamble's solution, Hatch's solution, and artificial lysosomal fluid, which are the most widely used physiologically based simulated human lung fluids. External factors such as simulated lung fluid composition, pH, extraction time, and sorption sinks can affect release bioaccessibility, whereas particle size and contaminant properties are important internal factors. Overall, release bioaccessibility is less used than bioaccessibility considering the deposition fraction when assessing the risk of contaminants in inhaled particulates. The release bioaccessibility measurement poses two main challenges: developing a unified, accurate, stable, simple, and systematic biologically based method, and validating the method through in-vivo assays.
Article
Full-text available
This study was designed to assess the variation of the air quality actually measured from the air pollution monitoring stations (AQMS) in three cities (Wuhan, Daegu, and Tokyo), in Asian countries experiencing the explosive outbreak of COVID-19, in a short period of time. In addition, we made a new attempt to calculate the reduced DosePM2.5 (μg) at the bronchiolar (Br.) and alveolar-interstitial (AI) regions of the 10-year-old children after the city lockdown/self-reflection of each city. A comparison of the average PM2.5 of a month before and after the lockdown (Wuhan) and self-reflection (Daegu and Tokyo) clearly shows that the PM2.5 concentration was decreased by 29.9, 20.9, and 3.6% in Wuhan, Daegu and Tokyo, respectively. Wuhan, Daegu and Tokyo also recorded 53.2, 19.0, and 10.4% falls of NO2 concentration, respectively. Wuhan, which had the largest decrease of PM2.5 concentration due to COVID-19, also marked the largest reduced DosePM2.5 10-year-old children (μg) (3660 μg at Br. and 6222 μg at AI), followed by Daegu (445 μg at Br. and 1,287 μg at AI), and Tokyo (18 μg at Br. and 52 μg at AI), over two months after the city lockdown/self-reflection. Our results suggest that the city lockdown/self-reflection had the effect of lowering the concentration of PM2.5, resulting in an extension of the period it took to the acute allergic airway inflammation (AAI) for the 10-year-old children.
Article
Full-text available
A study of the deposition and clearance of inhaled particles in the human nasal passage has identified and quantified the major routes of particle transport clearance from the nose. The results of the study have been used to construct a compartment model describing extrathoracic clearance. Experimental evidence for each of the model's clearance routes is discussed.
Article
Full-text available
Twelve healthy nonsmokers inhaled monodisperse Teflon particles labelled with 51Cr (half-life 27.8 days) with an aerodynamic diameter (dae) of 6.1 microns, 5 at a normal flow, 0.5 L/s, and 7 at an extremely slow flow, 0.05 L/s. Lung retention after 24 hours was measured for about 6 months and could be well described by a 2-component exponential function. After the normal inhalation, 14% of the particles retained after 24 hours cleared with a half-time of 3.7 days and 86% with a half-time of 217 days. After the slow inhalation, 35% of the particles retained after 24 hours cleared with a half-time of 3.6 days and 65% with a half-time of 170 days. Deposition was calculated using 3 different models including the recent Human Respiratory Tract Model (HRTM), adopted by the International Commission on Radiological Protection (ICRP), and a model based on Monte Carlo particle transport, together with an asymmetric lung model. Generally, the 3 models agreed fairly well and predicted a considerably higher deposition in the bronchiolar region (generations 9-15) at the slow flow than at the normal flow. Together, the experimental data and the predictions of the deposition models indicate that about 40% of the particles deposited in the conducting airways during the slow inhalation were retained after 24 hours. They also strongly indicate that the particles which cleared with a half-time of about 4 days were mainly deposited in the bronchiolar region, and that about 25% of the particles deposited in the bronchiolar region cleared in this phase. The experimental data agreed quite well with the HRTM predictions made using its default parameter values for slow clearance in the bronchial tree.
Article
Two distinct phases of particle clearance from the human lungs are usually observed. It was generally assumed that the rapid phase, complete within about a day, represents clearance of the material deposited in the tracheo-bronchiolar (TB) airways, and the much slower phase alveolar deposition. This assumption was used as the basis for measurements of regional lung deposition. In a series of experiments, radiolabelled particles were administered to volunteers as a small 'bolus' at a preselected point in the breathing cycle, to deposit them at a chosen lung depth. When the bolus was administered near the end of the breath ('shallow'), in order to deposit the particles in the bronchial region, only about 50% of the material cleared rapidly. This finding was reproducible in different subjects, and with particles of different materials. Experiments in which the particles were administered with the subject horizontal, or with the particles inhaled rapidly to increase deposition in the large airways, gave similar results. Complementary measurements of bolus deposition as a function of particle size and breath-holding time did not support the explanation that a large fraction of the bolus was reaching the alveolar region. The results, with those of further bolus clearance experiments, using particles of different sizes and densities, suggest that there is a slow phase of TB clearance, and that the slowly cleared fraction of the TB deposit decreases with increasing particle geometric diameter. On the basis of these observations a particle size dependent slow phase of bronchial and bronchiolar clearance was included in the new ICRP dosimetric model for the human respiratory tract.
Article
This report is yet another valuable reference text in the series of International Commission on Radiological Protection (ICRP) publications. The information contained in the report is mostly tabulated and drawn from a wide variety of ICRP reports (numbers 56, 67, 69 and 71), providing a compilation of age-dependent committed effective-dose coefficients for members of the general public due to inhalation or ingestion of a variety of radionuclides. The information is likely to be of direct benefit to those involved in radiation protection for the nuclear, environmental and health-care industries. It is unlikely to be of use to those interested in medical research since the chemical/pharmaceutical form is not considered in detail. It is a report for use by a specialist and not for casual reading: in short, a key text for any institution that already makes use of ICRP publications.
Article
Ten healthy males inhaled monodisperse Teflon particles (geometric diameter 3.6 μm, aerodynamic diameter 5.3 μm) labeled with ¹⁹⁵Au (half-life 183 days). The leakage of ¹⁹⁵ Au from the particles in vitro in water was less than 0.2% per year. Retention over the thorax was followed for about 900 days using two separate detector systems. One system consisted of four Ge detectors placed close to the front of the chest over the upper and lower regions of the lungs. The other system consisted of three NaI crystals placed in a ring around the thorax at some distance from the chest wall. Activities of ¹⁹⁵Au in feces (24- or 48-h samples) could be measured as long as activities in the thorax could be measured. For the period 7-250 days, the half-times were similar for the two detectors, on the average 740 days for the NaI detectors and 680 days for the Ge detectors. The average half-times estimated from measurements from about 250 days to about 900 days were 1750 days with the NaI detectors and 880 days with the Ge detectors. Clearance curves constructured from measurements from feces agreed very well with clearance measured with the NaI detectors. The excretion via feces was well described by a power function with days after exposure as base. This total clearance from the thoracic region was slower than in earlier studies. No activity could be measured in the urine. The measurements with the two detector systems show that a translocation within the thoracic region occurred. This might be explained by transportation of particles from the lung parenchyma to the regional lymph nodes. The accumulation of particles in the regional lymph nodes was tentatively calculated on the basis of that assumption. 24 refs., 8 figs., 3 tabs.
Article
Abstract The retention of 133Ba in the trachea from intratracheally administered 133BaSO4 particles was determined in rabbits, dogs, and monkeys. A significant retention of Ba in the trachea was observed with two peaks in these three animal species 1 week after administration. The first peak in the cranial region of the trachea corresponded to the approximate position of the tracheostomy and the second peak in the caudal trachea corresponded to the approximate position of the tip of the cannula. The amount of 133Ba retained 1 week after injection in the caudal region of trachea, which indicated the physiological retention of particles in the airway wall, was 0.145, 0.044, and 0.043% of the initial injection dose for rabbits, dogs, and monkeys, respectively. These retention rates were much lower than those measured in a previous rat study. If experimental conditions of anesthesia and relative injection dose (e.g., the amount of 133BaSO4 per surface area of the tracheal lumen) did not affect particle retention, the present results may suggest that the extent to which particle retention occurred in airway walls is different among the animal species.
Article
Long-term retention of 133Ba in the trachea from intratracheally administered BaSO4 particles was determined by both serial sacrifice and external scanning methods up to 6 months after injection. The amount of 133Ba retained 1 week after injection in the caudal region of the trachea, where the tip of the cannula had been at injection, was 0.41% of the initial dose. Thereafter the 133Ba was cleared exponentially with a mean half-time of 88 days, as determined from the autopsy samples. The cranial region of the trachea, including the site of the tracheostomy, contained 133Ba at 10 times the level in the caudal region 1 week after injection and was cleared with a half-time of 66 days. These clearance rates were confirmed by repeated external scanning over the trachea. The 133Ba was drained to the lymph nodes not only in the thoracic cavity but also in the cervical region, suggesting the possibility of lymphatic drainage from the trachea to the cervical lymph nodes.
Article
Experiments with a bolus technique suggest that retained fractions in the airways are dependent on the geometric diameter of the particles. This view has been adopted by the International Commission on Radiological Protection (ICRP) in its new human respiratory tract model (HRTM). The aim of the present study was to test this view by the use of an inhalation technique, in which particles with an aerodynamic diameter of about 6 microns are inhaled extremely (0.05 l/s) and as a result, the particles are deposited mainly in small ciliated airways. Nine healthy subjects inhaled on one occasion monodisperse 111In-labelled polystyrene particles (geometric diameter 6.05 microns, aerodynamic diameter 6.2 microns) and on another occasion monodisperse 111In-labelled Teflon particles (geometric diameter 4.47 microns, aerodynamic diameter 6.5 microns). Both particles were inhaled at 0.045 L/s and radioactivity in the body was measured after 0, 24, 48, and 72 hours as well as after 1, 2, and, for some subjects, also 3 weeks. The retention in the lungs at 24 hours was slightly lower for the Teflon particles (47%) than for the polystyrene particles (51%). From earlier experimental data with different particle sizes as well as from predictions with theoretical lung models, this difference is reasonably explained by the somewhat larger aerodynamic diameter of the Teflon particles. Clearance of the 2 particle types between 1 day and 2 weeks was similar within each individual as well as in the whole group. The differences between the clearance of 4.5 microns and 6 microns geometric diameter particles observed in the present experiment are significantly different (P < .01) from the differences seen in earlier shallow bolus experiments as well as from the differences for such particles calculated with the HRTM, i.e., our experiment does not support the hypothesis that the fraction retained after 1 day is dependent on the geometric diameter in the size range studied.
Article
The objective of this study is to investigate the sources of variability and uncertainty in a previously developed human lung dosimetry model. That three-compartment model describes the retention and clearance kinetics of respirable particles in the gas-exchange region of the lungs. It was calibrated using exposure histories and lung dust burden data in U.S. coal miners. A multivariate parameter estimation and optimization method was developed for fitting the dosimetry model to these human data. Models with various assumptions about overloading of alveolar clearance and interstitialization (sequestration) of particles were evaluated. Variability in the estimated clearance rate coefficients was assessed empirically by fitting the model to groups' and to each miner's data. Distributions of lung and lymph node particle burdens were computed at working lifetime exposures, using the variability in the estimated individual clearance rate coefficients. These findings confirm those of the earlier analysis; i.e., the best-fitting exposure-dose model to these data has substantial interstitialization/sequestration of particles and no dose-dependent decline in alveolar clearance. Among miners with different characteristics for smoking, disease, and race, the group median estimated alveolar clearance rate coefficients varied by a factor of approximately 4. Adjustment for these group differences provided some improvement in the dosimetry model fit to all miners (up to 25% reduction in MSE), although unexplained interindividual differences made up the largest source of variability. The predicted mean lung and lymph node particle burdens at age 75 after exposure to respirable coal mine dust at 2 mg/m(2) for a 45-year working lifetime were 12 g (5th and 95th percentiles, 3.0-26 g) and 1.9 g (0.26-5.3), respectively. This study provides quantitative information on variability in particle retention and clearance kinetics in humans. It is useful for risk assessment by providing estimated lung dust burdens associated with occupational exposure to respirable particles.