Long-Term Evaluation of a Compliant Cushion Form Acetabular Bearing for Hip Joint Replacement: A 20 Million Cycles Wear Simulation

Research & Development Center, Active Implants Corporation, Netanya 42505, Israel.
Journal of Orthopaedic Research (Impact Factor: 2.99). 12/2011; 29(12):1859-66. DOI: 10.1002/jor.21471
Source: PubMed

ABSTRACT

Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should be supported by accurate descriptions of the implant following usage and of the number, volume, and type of wear particles generated. We report on a long-term 20 million cycle (Mc) wear study of a commercial hip replacement system composed of a compliant polycarbonate-urethane (PCU) acetabular liner coupled to a cobalt-chromium alloy femoral head. The PCU liner showed excellent wear characteristics in terms of its low and steady volumetric wear rate (5.8-7.7 mm(3)/Mc) and low particle generation rate (2-3 × 10(6) particles/Mc). The latter is 5-6 orders of magnitude lower than that of highly cross-linked polyethylene and 6-8 orders of magnitude lower than that of metal-on-metal bearings. Microscopic analysis of the implants after the simulation demonstrated a low damage level to the implants' articulating surfaces. Thus, the compliant PCU bearing may provide a substantial advantage over traditional bearing materials.

Download full-text

Full-text

Available from: Jonathan J Elsner
  • [Show abstract] [Hide abstract]
    ABSTRACT: Metal-on-metal total hip arthroplasty (MOM THA) has the advantage of replicating the femoral head size, but the postoperative elevation of serum metal ion levels is a cause for concern. Metal-on-polycarbonate-urethane is a new cushion bearing featuring a large diameter metal head coupled with a polycarbonate-urethane liner. The aim of this study was to assess and compare serum cobalt (Co) and chromium (Cr) levels in a group of 15 patients treated with a cushion bearing THA system (Group A) and a group of 15 patients treated with a MOM THA system (Group B) at short-term. At a mean follow-up of 27.3 months (18-35 months), in Group A the median Cr and Co serum levels were significantly lower than in Group B, measuring 0.24 μg/L (0.1-2.1 μg/L) and 0.6 μg/L (0.29-2.3 μg/L) compared to 1.3 μg/L (0.1-9 μg/L, p < 0.001) and 2.9 μg/L (0.85-13.8 μg/L, p < 0.001) respectively. All patients demonstrated an excellent clinical result, as shown by the Harris and Oxford hip scores. The cushion bearing THA studied in this paper showed clinical outcomes similar to the MOM THA bearing, with the advantage of no significant metal ion elevation in the serum. These findings warrant the continued clinical study of compliant bearing options.
    No preview · Article · Aug 2011 · Archives of Orthopaedic and Trauma Surgery
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The use of an artificial joint is always related to a certain amount of wear. Its biological effects, e.g., the osteolysis potential, are a function of the bulk material as well as its debris. Following comprehensive experiences with polyethylene (PE) wear, material science is tracking two ways to minimize the risk of a particle-induced aseptic implant loosening: (i) reduction of the PE debris by a low-wearing articulation partner; and (ii) replacement of the PE by other materials. Therefore, new ceramics (e.g., ZTA, Si(3)N(4)), as well as coatings (e.g., TiN, "diamond-like" carbon) and modifications of a bulk metal (e.g., oxidizes zirconium) or cushion bearings (polyurethane, hydrogels), are currently available for total joint replacements or have been used for pre-clinical testing. This review gives a brief overview and evaluates the potential of those that have recently been published in literature.
    Full-text · Article · Mar 2012 · Acta biomaterialia
  • [Show abstract] [Hide abstract]
    ABSTRACT: Here, we summarize the principles of tribology and demonstrate the importance of wear particle analysis in condition monitoring. The principles of Ferrography, a technique that was originally developed for condition monitoring of engineering systems, are explained. A new modification of this technique, known as Bio-Ferrography, is reviewed and its application in magnetic isolation of target cells or tissues is demonstrated. Routes for magnetic labeling of biological matter and synthetic polymers are also presented. The hip and knee natural joints are discussed, along with osteoarthritis-their most common noninflammatory disorder. The use of Ferrography and Bio-Ferrography for isolating bone and cartilage particles from the synovial fluids in osteoarthritic joints is reviewed. Artificial joints and the use of Ferrography and Bio-Ferrography for monitoring their wear, either during the development stage or during service, are also reviewed. The concept of soft bearing materials is presented. © 2012 Springer Science+Business Media New York. All rights are reserved.
    No preview · Article · Jul 2012
Show more