Article

Accuracy and precision of a laser-spectroscopy approach to the analysis of δ2H and δ18O in human urine

Department of Biology, University of Utah, Salt Lake City, UT 84112, USA.
Isotopes in Environmental and Health Studies (Impact Factor: 0.96). 12/2010; 46(4):476-83. DOI: 10.1080/10256016.2010.536229
Source: PubMed

ABSTRACT

The isotope ratio analysis of body water often involves large sample numbers and lengthy sample processing. Here we demonstrate the ability of isotope ratio infrared spectroscopy (IRIS) to rapidly and accurately analyse the isotope ratios of water in urine. We analysed water extracted from human urine using traditional isotope ratio mass spectrometry (IRMS) and compared those values with IRIS-analysed extracted water and un-extracted urine. Regression analyses for δ²H and δ¹⁸O values between (1) extracted water analysed via IRMS and IRIS and (2) urine and extracted water analysed via IRIS were significant (R²=0.99). These results indicate that cryogenic distillation of urine was not required for an accurate estimate of the isotopic composition of urine when using IRIS.

Download full-text

Full-text

Available from: James R Ehleringer
  • Source
    • "A further significant advantage of the DS-CRDS system is the separation of the analysed water vapour from nonvolatile dissolved and particulate contaminants in the liquid sample. This avoids deposition of contaminants in the vaporisation unit and limits CRDS spectral interferences associated with organic contaminants and complicated matrices such as plant extracts, urine and beverages, [12] [13] [14] [15] and removes the need to filter samples with high particulate content (e.g. environmental waters). "
    [Show abstract] [Hide abstract]
    ABSTRACT: A novel sampling device suitable for continuous, unattended field monitoring of rapid isotopic changes in environmental waters is described. The device utilises diffusion through porous PTFE tubing to deliver water vapour continuously from a liquid water source for analysis of δ¹⁸O and δD values by Cavity Ring-Down Spectrometry (CRDS). Separation of the analysed water vapour from non-volatile dissolved and particulate contaminants in the liquid sample minimises spectral interferences associated with CRDS analyses of many aqueous samples. Comparison of isotopic data for a range of water samples analysed by Diffusion Sampling-CRDS (DS-CRDS) and Isotope Ratio Mass Spectrometry (IRMS) shows significant linear correlations between the two methods allowing for accurate standardisation of DS-CRDS data. The internal precision for an integration period of 3 min (standard deviation (SD) = 0.1‰ and 0.3‰ for δ¹⁸O and δD values, respectively) is similar to analysis of water by CRDS using an autosampler to inject and evaporate discrete water samples. The isotopic effects of variable air temperature, water vapour concentration, water pumping rate and dissolved organic content were found to be either negligible or correctable by analysis of water standards. The DS-CRDS system was used to analyse the O and H isotope composition in short-lived rain events. Other applications where finely time resolved water isotope data may be of benefit include recharge/discharge in groundwater/river systems and infiltration-related changes in cave drip water.
    Full-text · Article · Dec 2011 · Rapid Communications in Mass Spectrometry
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Stable isotope biogeochemistry is useful for quantifying the feeding ecology of modern and extinct primates. Over the past three decades, substantial advances have been made in our knowledge of the physiological causes of isotopic patterns as well as effective methodology to prepare samples for isotopic analysis. Despite these advances, the potential of stable isotope biogeochemistry has yet to be fully exploited by primate researchers, perhaps due to the prolific and somewhat daunting nature of the isotopic literature. I here aim to present a cogent overview of stable isotope applications to nonhuman primate feeding ecology. I review the factors that influence ecological patterns in carbon, nitrogen, and oxygen stable isotopes. I present methods for collecting and preparing samples of tooth enamel and bone mineral hydroxyapatite, bone collagen, fur and hair keratin, blood, feces, and urine for isotope analysis. I discuss both the existing and potential applications of these isotopic patterns to primate feeding ecology. Lastly, I point out some of the pitfalls to avoid when interpreting and comparing isotopic results.
    Full-text · Article · Jun 2012 · International Journal of Primatology
  • Source

    Full-text · Article · Jan 2011 · Rapid Communications in Mass Spectrometry
Show more