Diagnostic accuracy of contrast-enhanced ultrasound in differentiating benign and malignant focal liver lesions: A retrospective study

Department of Diagnostic Radiology, Singapore General Hospital, Singapore.
Journal of Medical Imaging and Radiation Oncology (Impact Factor: 1.11). 10/2010; 54(5):421-30. DOI: 10.1111/j.1754-9485.2010.02195.x
Source: PubMed

ABSTRACT

The purpose of this study was to assess the diagnostic accuracy of our early experience with contrast-enhanced ultrasound (CEUS) in the characterisation of focal liver lesions (FLLs) using histopathology, contrast-enhanced computed tomography (CT), magnetic resonance imaging (MRI) or other imaging follow-up as the standard of reference.
Seventy-three patients with 82 FLLs who underwent liver CEUS from January 2006 to December 2008 were retrospectively reviewed. CEUS was performed with up to 4.8 mL of SonoVue® (Bracco, Milan, Italy) using a low mechanical index mode. The CEUS findings were compared with histopathology, or where histopathology was not available, clinical and imaging follow-up over at least 12 months was used as the standard of reference.
Of the 82 FLLs, 50 were malignant and 32 were benign at final diagnosis. CEUS correctly identified 43 malignant FLLs, with final diagnosis confirmed by histopathology in 13 lesions and clinico-radiological follow-up in 30 lesions. Twenty-nine lesions were correctly identified as benign on CEUS, with all these lesions confirmed on clinico-radiological follow-up. CEUS demonstrated a sensitivity of 86.0% and a specificity of 90.6% in the characterisation of liver lesions as malignant, with an overall accuracy of 87.8% (P < 0.05).
Our early experience has shown that CEUS can be accurate in differentiating malignant from benign FLLs and may become a useful first-line imaging tool where CT or MRI are not available or contra-indicated.

2 Followers
 · 
16 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this study was to determine whether contrast-enhanced sonography can be used to differentiate histopathologic grades of hepatocellular carcinoma. This study included 54 patients with hepatocellular carcinomas. All patients underwent fundamental and contrast-enhanced sonographic examinations. Auto-tracking contrast quantification software was used to determine the contrast arrival time, time to peak, peak intensity, contrast-enhanced time, wash-out time, enhancement slope, and clearance slope of the lesions. All lesions were confirmed by surgery. The hepatocellular carcinoma lesions were divided into 2 groups according to the World Health Organization grading system: group 1 (well-differentiated hepatocellular carcinomas) and group 2 (moderately to poorly differentiated carcinomas). The enhancement parameters between the groups were compared using a Student t test. Fourteen of 20 well-differentiated lesions showed a "fast-in, slow-out" enhancement pattern, whereas 6 showed a "fast-in, fast-out" pattern. Thirty-three of 34 moderately to poorly differentiated lesions showed a fast-in, fast-out pattern, whereas only 1 showed a fast-in, slow-out pattern. The differences in the time to peak, contrast-enhanced time, wash-out time, enhancement slope, and clearance slope between the groups were statistically significant (P < .05), whereas the differences in the arrival time and peak intensity were not significant (P > .05). The contrast patterns of well-differentiated and moderately to poorly differentiated hepatocellular carcinomas were quite different on contrast-enhanced sonography. The time to peak, contrast-enhanced time, and wash-out time of the well-differentiated hepatocellular carcinomas were longer than those of the moderately to poorly differentiated carcinomas, whereas the enhancement slope and clearance slope of the well-differentiated lesions were lower those that of the moderately to poorly differentiated lesions.
    No preview · Article · May 2011 · Journal of ultrasound in medicine: official journal of the American Institute of Ultrasound in Medicine
  • [Show abstract] [Hide abstract]
    ABSTRACT: International guidelines of Ultrasound recommend the performance of contrast-enhanced ultrasound (CEUS) as the first method of choice after conventional ultrasound for the diagnostic work-up of focal liver lesions. However, these recommendations are based on the results of multiple single studies and only few large multicentre studies. The rationale of the present systematic review and meta-analysis was to assess the overall sensitivity and specificity of CEUS for the diagnosis of malignant liver lesions. Literature databases were searched up to March 2012. Inclusion criteria were evaluation of CEUS, assessment of sensitivity and specificity of CEUS for the diagnosis of malignant liver lesions. The meta-analysis was performed using the random-effects model based on the DerSimonian Laird method. Quality analyses were carried out to assess sources of heterogeneity. A total of 45 studies with 8147 focal liver lesions were included in the analysis. Overall sensitivity and specificity of CEUS for the diagnosis of malignant liver lesions was 93% (95%-CI: 91–95%) and 90% (95%-CI: 88–92%) respectively. Significant heterogeneity was found between studies. However, subanalysis revealed no significant difference when evaluating studies using histology for all liver lesions, when comparing high-quality and low-quality studies, and blinded vs non-blinded studies. The results of this meta-analysis support the international recommendations on CEUS for the diagnostic work-up of focal liver lesions selecting patients who need further diagnostics.
    No preview · Article · Jan 2013 · Liver international: official journal of the International Association for the Study of the Liver
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: INTRODUCTION: The use of contrast agents (CA) with liver ultrasound (US) has gained recently an established role for the diagnosis of various hepatic diseases due to their safety, high versatility and low costs (contrast-enhanced ultrasound - CEUS). The purpose of this review is to provide a state-of-the-art summary of the available evidence for their use in the characterization of focal liver lesions. MATERIALS AND METHODS: A literature search was conducted for all pre-clinical and clinical studies involving CA on hepatic US imaging. RESULTS: CEUS increases the sensitivity for lesion detection and the specificity to differentiate between benign and malignant diseases due to the enhanced visualization of the tumour microcirculation. Results achieved seem at least equivalent to those of spiral Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The association of CA with intraoperative ultrasound (CE-IOUS) has changed the surgical approach in 25% of patients and guarantees complete ablations by a single session in most of them. CONCLUSIONS: CEUS provides detailed information about tumor vasculature, improves the preoperative characterization and therefore the therapeutic strategy, and can evaluate the intraoperative completeness of the ablation.
    Full-text · Article · Jun 2013 · Hepatology Research
Show more