This present paper evaluated a batch electrocoagulation (EC) scale containing two flat aluminium plate electrodes to treat total Cr, Zn ²⁺ in real plating wastewater taken from CX Technology company. Response Surface Methodology (RSM) and Design-Expert 12 software were applied to optimize the operating conditions with three main factors including current density, pH, and retention time. The control experiments using FeSO 4 10% were performed to compare with the electrocoagulation method. The best treatment efficiency occurred at a current density of 16.93 A/m ² , pH 9, and a 31-minute reaction. The conductivity did not significantly affect to the total Cr and Zn ²⁺ removal but reduced energy consumption. The jar-test experiment result was obvious the optimal factors of the coagulation-flocculation encompassing pH 10 and 3 ml/L FeSO 4 10 %. The treatment efficiency of total Cr and Zn ²⁺ were 97.22±0.3 % and 99.53± 0.006 %, higher than others. The generated sludge in the electrocoagulation method was 2,031± 0.91 g/L, equal to 51.7 % sludge of the coagulation-flocculation method. The treatment cost by electrocoagulation was less than others.

No full-text available

Request Full-text Paper PDF

To read the full-text of this research,
you can request a copy directly from the authors.

ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
Water pollution by recalcitrant compounds is an increasingly important problem due to the continuous introduction of new chemicals into the environment. Choosing appropriate measures and developing successful strategies for eliminating hazardous wastewater contaminants from industrial processes is currently a primary goal. Electroplating industry wastewater involves highly toxic cyanide (CN), heavy metal ions, oils and greases, organic solvents, and the complicated composition of effluents and may also contain biological oxygen demand (BOD), chemical oxygen demand (COD), SS, DS, TS, and turbidity. The availability of these metal ions in electroplating industry wastewater makes the water so toxic and corrosive. Because these heavy metals are harmful to living things, they must be removed to prevent them from being absorbed by plants, animals, and humans. As a result, exposure to electroplating wastewater can induce necrosis and nephritis in humans and lung cancer, digestive system cancer, anemia, hepatitis, and maxillary sinus cancer with prolonged exposure. For the safe discharge of electroplating industry effluents, appropriate wastewater treatment has to be provided. This article examines and assesses new approaches such as coagulation and flocculation, chemical precipitation, ion exchange, membrane filtration, adsorption, electrochemical treatment, and advanced oxidation process (AOP) for treating the electroplating industry wastewater. On the other hand, these physicochemical approaches have significant drawbacks, including a high initial investment and operating cost due to costly chemical reagents, the production of metal complexes sludge that needs additional treatment, and a long recovery process. At the same time, advanced techniques such as electrochemical treatment can remove various kinds of organic and inorganic contaminants such as BOD, COD, and heavy metals. The electrochemical treatment process has several advantages over traditional technologies, including complete removal of persistent organic pollutants, environmental friendliness, ease of integration with other conventional technologies, less sludge production, high separation, and shorter residence time. The effectiveness of the electrochemical treatment process depends on various parameters, including pH, electrode material, operation time, electrode gap, and current density. This review mainly emphasizes the removal of heavy metals and another pollutant such as CN from electroplating discharge. This paper will be helpful in the selection of efficient techniques for treatment based on the quantity and characteristics of the effluent produced.
Article
Full-text available
Fate and health exposure linked with pollutants in water are one of the major environmental protests. Electroplating wastewater involves toxic pollutants, which are harmful to living organisms. During the last two decades, advanced oxidation processes (AOP’s) for effectively decontaminate water have drawn great attention. Among various AOP’s, electrochemical technologies appear to be the most promising methods for removing organic pollutants from industrial wastewater. The main objective of this review is to study the feasibility of electrochemical methods for the treatment of electroplating effluents and also found that the rate of toxic pollutants removal was significantly influenced by different anode materials.
Article
Full-text available
In this study, application and efficiency of electrocoagulation (EC) in the removal of nickel and iron from real powerplant wastewater was evaluated. Fe electrode (St 12) was used as anode and cathode, connected with parallel monopolar configuration. Tests were conducted in two phases. Phase I mainly focussed on changing the range of the parameters to attain the possible range in which the tests can be conducted and also reached the optimum efficiency. A stirred batch reactor was used to define the test parameters range, including initial pH, electrical current (A), electrode distance (cm) and electrolysis time (min). Then, phase II of this study was conducted using the response surface methodology to design and optimise operational parameters. Outcomes indicated that considering pH = 8.1, d = 1 cm, I = 1.5 A and t = 18 min as operational conditions can result in 99.9% removal efficiency. Remarkably, the high correlation between experimental and predicted values (R²=99.5% and 99.6% for iron and nickel, respectively) demonstrated that the EC process is a promising method to remove heavy metals from power plant wastewater.
Article
Full-text available
This study focuses on removing the metals: chromium, nickel, zinc and copper in high concentrations (particularly with chromium, whose concentration went up to 350 ppm) in plating wastewater by electrocoagulation (EC) method using direct current (DC). The wastewater was contained in a 2 L batch airlift reactor; pure oxygen 99.9 % was blown into the reactor to increase the treatment efficiency. Cylindrical iron electrodes were used in the cell. The results showed that pH, current density, and residence time were three major factors influencing the treatment effectiveness. Over 99.9 % of heavy metals were effectively removed when optimizing the operating conditions with the Response Surface Methodology (RSM) in the current density 8.79 mA/cm2, 30.01 minutes, at pH 4.95. Beside the consideration of the effectiveness of this method in different concentrations of plating wastewater Cyclic Voltammetry (CV) scan, and Tafel line were also used for measuring the existing ability of electrodes in the wastewater to study situations happening while operating the cell in the reality. With high efficiency, simple operation, no cost for chemical, and the power consumption of only 10 kWh/m3, this method can be used in treating plating wastewater in the reality.
Chapter
Full-text available
Advanced water/wastewater treatment techniques including ion exchange separation, filtration separation, and adsorption are essential in the removal of nonbiodegradable toxic wastes from water. In the current study, removal of heavy metal ions from water/wastewater and the use of response surface methodology (RSM) for experimental optimization were examined thoroughly. The objective of this work was to summarize the removal of heavy metal ions from water/wastewater using various chemical techniques and to emphasize the superiority of RSM in these studies.
Article
Full-text available
Hospital wastewater is a source of potential environmental contamination. Therefore, the waste water needs to be treated before it is discharged into the landfill. Various research methods have been used to treat hospital wastewater. However, some methods that have been implemented have not achieved the effluent standards for hospitals that have been set by the government. The experiment was conducted by an electrochemical method is electrolysis using aluminum electrodes with independent variable is the voltage, contact time and concentration of electrolytes. The response optimization using response surface with optimum conditions obtained by the contact time of 34.26 min, voltage 12 V, concentration electrolyte 0.38 M can decrease of COD 65.039%. The model recommended by the response surface for the three variables, namely quadratic response.
Article
Full-text available
The present study focuses on the response surface methodology (RSM) for the optimization of lead removal from an aqueous solution by a novel superparamagnetic nanocomposite. A rotatable central composite design and the response surface methodology were used to conduct and to analyze the experiments, respectively. The adsorption process was investigated as a function of the four factors consisting of pH (4.0–6.0), temperature (20℃–60℃), initial lead concentration (10–90 mg/L) and adsorbent dosage (0.2–1.0 g/L). The maximum lead adsorption capacity was obtained to be 124.955 mg/g under the optimal conditions of 5.49, 60℃, 89.08 mg/L, and 0.48 g/L for the solution pH, temperature, initial lead ion concentration, and the adsorbent dosage, respectively. The desirability function was used to find an optimum point where the desired conditions could be obtained. The superparamagnetic nanocomposite could be used as an adsorbent for the removal of toxic heavy metals from water and wastewater.
Article
Full-text available
This article may be used for research, teaching, and private study purposes. Any substantial or systematic reproduction, redistribution, reselling, loan, sub-licensing, systematic supply, or distribution in any form to anyone is expressly forbidden. The publisher does not give any warranty express or implied or make any representation that the contents will be complete or accurate or up to date. The accuracy of any instructions, formulae, and drug doses should be independently verified with primary sources. The publisher shall not be liable for any loss, actions, claims, proceedings, demand, or costs or damages whatsoever or howsoever caused arising directly or indirectly in connection with or arising out of the use of this material.
Article
In this study, optimum conditions for adsorption of heavy metals such as Cu²⁺, Cd²⁺ and Pb²⁺ onto a low-cost, magnetically modified-alkali conditioned anaerobically digested sludge (MADS) adsorbent were obtained. Response Surface Methodology (RSM) incorporating Central Composite Design (CCD) of experiments was applied to optimize four independent process variables. Statistical analysis was executed by ANOVA and the quadratic model developed had regression coefficients of 0.959, 0.957 and 0.95 for Cu²⁺, Cd²⁺ and Pb²⁺, respectively. The independent variables such as pH, time and initial concentration positively influenced adsorption capacity, qe, whereas the value of qe decreased with an increase in MADS dosage. Model validation experiments for optimization of adsorption process showed comparable results with predicted values. The adsorption capacity of MADS adsorbent at optimum conditions found through RSM analysis was 29.721 mg L⁻¹, 28.551 mg L⁻¹ and 28.601 mg L⁻¹ for Cu²⁺, Cd²⁺ and Pb²⁺ respectively.
Article
This study investigates the treatments of hospital wastewater by electrocoagulation using Fe, Al, and stainless steel (SS) electrodes in a batch electrochemical reactor. Parameters that affected the removal of total organic carbon (TOC) of the wastewater with a pH from 5 to 8 and a current density (CD) ranging from 2.03–4.87 mA/cm2 were examined. The optimum conditions were determined using response surface methodology. In accordance with the suggested mathematical models, maximum TOC removal efficiency was calculated as 99.11% (pH 7.56, CD 4.87 mA/cm2), 99.91% (pH 5.45, CD 4.46 mA/cm2), and 99.89% (pH 7.80, CD 2.68 mA/cm2) for the Fe, Al, and SS electrodes, respectively. The experimental results were also in reasonable agreement with the used model. For all electrodes, the removal efficiencies were high. After analysis of variance (ANOVA), the determination coefficients of the models were 99.87%, 96.02%, and 94.15% showing that the quadratic models were a good fit and of high significance. The model predictions were confirmed to be appropriate to the experimental data with a deviation of <2.5%. In addition, the SS electrode is better than the Fe and Al electrodes according to energy consumption cost.
Article
Removal of copper (Cu), chromium (Cr) and nickel (Ni) from metal plating wastewater by electrocoagulation with iron and aluminum electrodes with monopolar configurations was investigated. The influence of electrode material, current density, wastewater pH and conductivity on removal performance was explored. The results showed that metal removal increased with increasing current density, pH and conductivity. The efficiency of different electrode materials (iron, aluminum) was compared. The results indicated that electrocoagulation with an Fe–Al electrode pair was very efficient and was able to achieve 100% Cu, 100% Cr and 100% Ni removal at an electrocoagulation time of 20 min, a current density of 10 mA/cm2 and a pH of 3.0. Corresponding energy and electrode consumptions were determined as 10.07 kWh/m3 and 1.08 kg/m3, respectively.Graphical abstractResearch highlights► Electrocoagulation treatment achieves a fast and effective reduction of metals. ► The Fe-Fe and Fe-Al electrode combinations were more effective for metal removal. ► The highest current density (10 mAcm−2) produced the quickest treatment.
Article
In the present work, electrocoagulation process with iron and aluminum electrodes was investigated to deepen the understanding of the mechanism of hexavalent chromium (Cr(VI)) removal. Electrocoagulation treatment efficiency was studied with regards to the abatement of Cr(VI) and the resulting species-namely Cr(III), Fe(II) and/or Fe(III). Unlike iron, aluminum electrodes were found to be unsatisfactory for Cr(VI) removal. To elucidate the removal mechanism of hexavalent chromium, different anode/cathode materials and configurations (Fe/Fe, Pt Ti (platinized titanium)/Fe, Al/Al and Pt Ti/Al) were considered. At nearly neutral pH and considering aluminum electrodes, both electrochemical reduction (Cr(VI) to Cr(III)) at the cathode surface and adsorption on Al(OH)(3) floc mechanisms were responsible for Cr(VI) exhaustion. However, the contribution of the two mechanisms to Cr(VI) removal was not discriminated. On the other hand, in the case of iron electrodes, even though electrochemical reduction may contribute to chromium removal, its influence seemed to be minor since the effect was confined to less than 5% of the removal efficiency. Hence, there was essentially one real root for the reduction of Cr(VI) by electrocoagulation with iron electrodes, and it was proven to be the chemical reduction by Fe(II) anodically generated. Moreover, the resulting Cr(III) was quickly removed from solution, via efficient precipitation as Cr(OH)(3) hydroxides. Besides, the electrodissolved iron remained at low level owing to the precipitation of Fe(OH)(2) and/or Fe(OH)(3). Although chemical reduction by Fe(II) predominantly governed the removal of Cr(VI), acidic pH media was found to promote electrochemical reduction of hexavalent chromium at the cathode and accordingly to enhance Cr(VI) removal efficiency. In contrast, a delay of Cr(III) precipitation and a contamination of the electrolyte by electrodissolved iron were observed under acidic conditions. The effect of supporting electrolyte (Na(2)SO(4) and NaCl) on chromium removal was also studied. No conspicuous disparity in the treatment efficiency was noted under the electrocoagulation conditions used.
Article
The performance of an electrocoagulation system with aluminium electrodes for removing heavy metal ions (Zn2+, Cu2+, Ni2+, Ag+, Cr2O7(2-)) on laboratory scale was studied systematically. Several parameters - such as initial metal concentration, numbers of metals present, charge loading and current density - and their influence on the electrocoagulation process were investigated. Initial concentrations from 50 to 5000 mg L(-1) Zn, Cu, Ni and Ag did not influence the removal rates, whereas higher initial concentrations caused higher removal rates of Cr. Increasing the current density accelerated the electrocoagulation process but made it less efficient. Zn, Cu and Ni showed similar removal rates indicating a uniform electrochemical behavior. The study gave indications on the removal mechanisms of the investigated metals. Zn, Cu, Ni and Ag ions are hydrolyzed and co-precipitated as hydroxides. Cr(VI) was proposed to be reduced first to Cr(III) at the cathode before precipitating as hydroxide.