ArticlePDF Available

Review of High Performance Liquid Chromatography and Its Applications

Authors:
  • Divine Collage Of Pharmacy,Satana

Abstract

A review of High-Performance Liquid Chromatography included an introduction, chromatographic terms, different classes, and types of HPLC techniques. Also included a brief introduction to HPLC principle and instrumentation. Columns, pumps, and detectors used in HPLC are also included in detail with their efficiency. Applications of the HPLC and overall new advantage cues are included in this review article. High Performance Liquid Chromatography (HPLC) is an important qualitative and quantitative technique, generally used for the estimation of pharmaceutical and biological samples. The chromatography term is derived from the Greek words namely chroma (color) and graphein (to write). Chromatography is defined as a set of techniques that are used for the separation of constituents in a mixture. This technique involves 2 phases stationary phase and a mobile phase. The separation of constituents is based on the difference between partition coefficients of the two phases. Chromatography is a very popular technique and it is mostly used analytically. There are different types of chromatographic techniques namely Paper Chromatography, Thin Layer Chromatography (TLC), Gas Chromatography, Liquid Chromatography, Ion exchange Chromatography, and lastly High Performance Liquid Chromatography (HPLC). This review is mainly based on the HPLC technique its principle, types, instrumentation, and applications. The mixture is separated using the basic principle of column chromatography and then identified and quantified by spectroscopy. In the 1960s, the column chromatography LC with its low-pressure suitable glass columns was further developed to the HPLC with its high-pressure adapted metal columns. Keywords: HPLC; Columns; Pumps; Injections; Detectors
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
1
Review of High Performance Liquid Chromatography and Its
Applications
Rushikesh Bachhav*, Piyush Bachhav, Mayur Bhamare, Ruchita Bachhav, Ganesh Sonawane, Kajal
Pansare, Dhananjay Patil
Department of Pharmacy, Divine College of Pharmacy, Satana, India
Review Article
Received: 25-Sep-2023, Manuscript
No. JPPS-23-114596; Editor
assigned: 28-Sep-2023, Pre QC No.
JPPS-23-114596 (PQ); Reviewed: 12-
Oct-2023, QC No. JPPS-23-114596;
Revised: 19-Oct-2023, Manuscript
No. JPPS-23-114596 (R); Published:
26-Oct-2023,
DOI: 10.4172/2320-1215.12.3.004
*For Correspondence:
Rushikesh Bachhav, Department of
Pharmacy, Divine College of
Pharmacy, Satana, India
E-mail:
rushikeshbachhav2001@gmail.com
Citation: Bachhav P, et al. Review of
High Performance Liquid
Chromatography and Its Applications.
RRJ Pharm Pharm Sci. 2023;12:004
Copyright: © 2023 Bachhav P, et al.
This is an open-access article
distributed under the terms of the
Creative Commons Attribution
License, which permits unrestricted
use, distribution, and reproduction in
any medium, provided the original
author and source are credited.
ABSTRACT
A review of High-Performance Liquid Chromatography included an
introduction, chromatographic terms, different classes, and types of HPLC
techniques. Also included a brief introduction to HPLC principle and
instrumentation. Columns, pumps, and detectors used in HPLC are also
included in detail with their efficiency. Applications of the HPLC and overall
new advantage cues are included in this review article. High Performance
Liquid Chromatography (HPLC) is an important qualitative and quantitative
technique, generally used for the estimation of pharmaceutical and
biological samples.
The chromatography term is derived from the Greek words namely chroma
(color) and graphein (to write). Chromatography is defined as a set of
techniques that are used for the separation of constituents in a mixture.
This technique involves 2 phases stationary phase and a mobile phase.
The separation of constituents is based on the difference between partition
coefficients of the two phases. Chromatography is a very popular technique
and it is mostly used analytically. There are different types of
chromatographic techniques namely Paper Chromatography, Thin Layer
Chromatography (TLC), Gas Chromatography, Liquid Chromatography, Ion
exchange Chromatography, and lastly High Performance Liquid
Chromatography (HPLC). This review is mainly based on the HPLC
technique its principle, types, instrumentation, and applications. The
mixture is separated using the basic principle of column chromatography
and then identified and quantified by spectroscopy. In the 1960s, the
column chromatography LC with its low-pressure suitable glass columns
was further developed to the HPLC with its high-pressure adapted metal
columns.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
2
Keywords: HPLC; Columns; Pumps; Injections; Detectors
INTRODUCTION
General introduction to chromatography
Chromatography (from Greek Chroma "color" and graph in "to write") is the collective term for a set of laboratory
techniques for the separation of mixtures. It involves passing a mixture dissolved in a "mobile phase" through a
stationary phase, which separates the analyte to be measured from other molecules in the mixture based on
differential partitioning between the mobile and stationary phases. Subtle differences in a compound's partition
coefficient result in differential retention on the stationary phase and thus changing the separation.
History of chromatography
The history of chromatography begins during the mid-19th century. Chromatography, literally "color writing", was
used and named in the first decade of the 20th century, primarily for the separation of plant pigments such as
chlorophyll. New types of chromatography developed during the 1930s and 1940s made the technique useful for
many types of the separation process. Chromatography became developed substantially as a result of the work of
Archer John Porter Martin and Richard Laurence Millington synge during the 1940s and 1950s. They established
the principles and basic techniques of partition chromatography, and their work encouraged the rapid development
of several types of chromatography methods: Paper chromatography, gas chromatography, and what would become
known as high-performance. Since then, technology has advanced rapidly. Researchers found that the main
principles of Teat’s chromatography could be applied in many different ways, resulting in different varieties of
chromatography. Simultaneously, advances continually improved the technical performance of chromatography,
allowing the separation of increasingly similar molecules [1].
Introduction to high performance liquid chromatography
The advanced technique having faster separation time and increased accuracy, precision and sensitivity is High-
Performance Liquid Chromatography which is based on adsorption, partition, ion exchange, and gel permeation
principle. In this type of chromatography, the separation of compounds is carried out based on their idiosyncratic
polarities. The interaction of these compounds with the stationary phase of the column too is considered. The
equipment required for carrying out high-performance liquid chromatography includes a pump (used for moving the
mobile phase and analyte through the column), a stationary phase, and a detector. The retention time for the
analyte too is provided by the detector. Depending on the strength of interactions that take place between the
analyte and the stationary phase, retention time varies (Figure 1).
Figure 1. Flow diagram of high-performance liquid chromatography system.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
3
Based on modes of separation HPLC is classified into the following two types
Normal-phase chromatography, or NP: Normal-phase chromatography, or NP, is liquid chromatography's
classic form using polar stationery and non-polar mobile phases. The analyte is retained by the interaction
of its polar functional groups with the polar groups on the surface of the packing. Analytes elute from the
column starting with the least polar compound followed by other compounds in order of their increasing
polarity. Normal-phase chromatography is useful in the separation of analytes with low to intermediate
polarity and high solubility in low-polarity solvents. Water-soluble analytes are usually not good candidates
for normal-phase chromatography.
Reversed-phase chromatography, or RP: Reversed-phase chromatography, or RP, has become the most
common mode of liquid chromatographic separation. In RP the stationary phase is non-polar and the
mobile phase is polar. The analytes are attracted to the surface by their non-polar functional groups. The
most polar analyte elutes from the RP column first followed by other analytes in order of decreasing
polarity. RP chromatography is useful for the separation of compounds having high to intermediate polarity
[2,3].
Based on the separation mechanism and type of stationary phase used
Adsorption chromatography
Partition chromatography
Ion exchange chromatography
Pore penetration (permeation) chromatography
Bio affinity chromatography
Chiral phase chromatography
This classification is based on different types of stationary phases used while the liquid mobile phase is common
for all the above types depending upon the polarity of the solvent and compound which is to be separated.
Adsorption chromatography: The chemical mixture is needed to be passed over an adsorbent bed.
The different compounds present in this mixture get adsorbed on the bed at different rates. The
process is mostly carried out for analytical separation.
Partition chromatography: This type of separation technique, a mixture is separated by making use
of the partition of a solute between two solvents. In this process, one of the solvents is immobilized
with the help of a substance present in the filter paper or column.
Ion exchange chromatography: As the name suggests, the ion-exchange mechanism is used to
separate the analytes in this method of chromatography. It can be performed in 2 different modes,
i.e., the planar and column. The separation of charged compounds like peptides, amino acids,
proteins, etc. is carried out using a charged stationary phase.
In pore penetration chromatography: Molecules of the mixture are separated based on their size.
This technique of chromatography is also known as gel permeation or size exclusion
chromatography. Technically speaking, the separation is carried out based on the hydrodynamic
diameter of the molecules. Larger molecules present in the mixture are unable to enter the pores
of the media; therefore, these molecules are washed out quickly. The smaller molecules on the
other hand take more time to elute, as they can enter the pores of media.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
4
In affinity chromatography: Non-covalent interaction takes place between the analyte in question
and certain molecules. The purification of proteins that are bound to tags is carried out with the
help of affinity chromatography.
Chiral phase chromatography: Chiral phase chromatography is a variant of column
chromatography in which the stationary phase contains a single enantiomer of a chiral compound
rather than being achiral. The two enantiomers of the same analyte compound differ in affinity to
the single-enantiomer stationary phase and therefore they exit the column at different times. The
chiral stationary phase can be prepared by attaching a suitable chiral compound to the surface of
achiral support such as silica gel, which creates a Chiral Stationary Phase (CSP). Many common
chiral stationary phases are based on oligosaccharides such as cellulose or cyclodextrin (in
particular with β-cyclodextrin, a seven-sugar molecule). Chiral stationary phases are much more
expensive than comparable achiral stationary phases such as C18 [4,5].
LITERATURE REVIEW
Principle of high-performance liquid chromatography
High-Performance Liquid Chromatography (HPLC) is a separation technique utilizing differences in the distribution
of compounds to two phases, called stationary phase and mobile phase. The stationary phase designates a thin
layer created on the surface of fine particles and the mobile phase designates the liquid flowing over the particles.
Under a certain dynamic condition, each component in a sample has different distribution equilibrium depending
on solubility in the phases and/or molecular size. As a result, the components move at different speeds over the
stationary phase and are thereby separated from each other. This is the principle behind HPLC [6].
The column is a stainless steel (or resin) tube that is packed with spherical solid particles. The mobile phase is
constantly fed into the column inlet at a constant rate by a liquid pump. A sample is injected from a sample injector
near the column inlet. The injected sample enters the column with the mobile phase and the components in the
sample migrate through it, passing between the stationary and mobile phases. Compounds move in the column
only when are in the mobile phase. Compounds that tend to be distributed in the mobile phase, therefore, migrate
faster through the column while compounds that tend to be distributed in the stationary phase migrate slower. In
this way, each component is separated on the column and sequentially elutes from the outlet. Each compound
eluting from the column is detected by a detector connected to the outlet of the column.
When the separation process is monitored by the recorder starting at the time the sample is injected, a graph is
obtained. This graph is called a chromatogram. The time required for a compound to elute (called retention time)
and the relationship between compound concentration (amount) and peak area depend on the characteristics of
the compound. Retention time is therefore used as an index for qualitative determination and peak surface area (or
height) as an index for quantitative determination. The retention time of the target compounds and the
concentration for each unit of peak area is based on data obtained in advance by analyzing a sample with known
quantities of the reference standards. Normally, the reference standards are highly purified target compounds
(Figures 2 and 3) [7].
Figure 2. Components of high-performance liquid chromatography.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
5
Instrumentation of HPLC
a. Solvent Reservoir
b. Pump
High pressure-1000 to 5000 psi
c. Injector
Low pressure-stop the flow
High-pressure value
d. Column
Normal Phase-organic (water-free) mobile phase
Silica gel-non-aqueous
Adsorption
Reverse phase (C8, C18)-aqueous mobile phase
Partitioning
Ion-exchange-aqueous mobile phase
Molecular sieve-aqueous mobile phase
Size
e. Detector
Specific
Absorbance
Fluorescence
Electrochemical
Non-specific
Refractive index
Radioactivity
Conductivity [8,9].
Figure 3. General instrumentation of high-performance liquid.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
6
Solvent reservoir
Glass or stainless-steel containers capable of holding up to 1-liter mobile phase (pure organic solvents or aqueous
solution of salts and buffers). Inert to a variety of aqueous and non-aqueous mobile phases. Stainless steel should
be avoided for use with solvents containing halides ions solvent flow through an HPLC system begins in the solvent
reservoirs, which contain the solvents used to carry the sample through the system. The solvents should be filtered
through an inlet solvent filter to remove any particles that could potentially damage the system's sensitive
components. Reservoirs used for storing high-performance, low-pressure liquid chromatography mobile phase.
Complete reservoir system includes a plastic coated graduated bottle, a standard cap assembly, and solvent and
sparging filters (Figure 4).
Figure 4. An overview of the high-performance liquid chromatography.
Pumps
High performance liquid chromatography pump:
The pump is one of the most important components of HPLC since its performance directly affects retention time,
reproducibility, and detector sensitivity.
The two basic classifications of the pump are the constant-pressure and the constant-flow pump.
The constant-pressure pump is used only for column packing.
The constant-flow pump is the most widely used in all common HPLC applications.
Three main types of pumps are used in HPLC to propel the liquid mobile phase through the system (Figure 5).
Figure 5. High performance liquid chromatography pump.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
7
Pneumatic or constant pressure pump: They are pulse free; suffer from limited capacity as well as a dependence of
flow rate on solvent viscosity and column back pressure. They are limited to pressure less than 2000 psi (Figure 6).
Figure 6. Pneumatic pump for high performance liquid chromatography.
Displacement pump (Syringe pump): It produces a flow that tends to be independent of viscosity and back
pressure and also the output is pulse free. But it possesses a limited capacity (250 ml). For micro-HPLC
applications, a syringe pump allows for the maintenance of a constant flow at the microliter per minute flow rate
range. The syringe pump has to be refilled after it displaces the whole syringe volume (Figure 7).
Figure 7. Syringe pump for high performance liquid chromatography.
Reciprocating pump: It has a small internal volume (35 to 400 µl), a high output pressure (up to 10,000 psi), and
constant flow rates. But it produces a pulsed flow (Figure 8) [10-12].
Figure 8. Reciprocating pump for high performance liquid chromatography.
Modern pumps have the following parameters
Flow range:0.01 to 10 ml/min
Flow rate stability: Not more than 1%
For SEC flow rate stability should be less than 0.2%
Maximum pressure: Up to 5000 psi
Pressure pulsations: Less than 1% for normal and reversed phase mode
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
8
HPLC injection systems
There are three important ways of introducing the sample into the injection port.
Loop injection: In which, a fixed amount of volume is introduced by making use of a fixed volume loop
injector.
Valve injection: In which, a variable volume is introduced by making use of an injection valve.
On-column injection: In which, a variable volume is introduced using a syringe through a septum.
The commonly used type is the anodyne injector (loop injector) fixed near the pump. It has a range to inject from 20
µl to 100 µl volume. In the load, the position sample is injected by a syringe into the injector. In injection, the mode
sample is injected from the loop into the pump. When an injection is started, an air actuator rotates the valve:
Solvent goes directly to the column, and the injector needle is connected to the syringe. The air pressure lifts the
needle and the vial is moved into position beneath the needle. Then, the needle is lowered to the vial (Figures 9-13)
[13].
Figure 9. Redone injectors for high performance liquid chromatography.
Figure 10. Inject (move the sample loop into the mobile phase flow).
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
9
Figure 11. Inject (move the sample loop into the mobile phase flow).
Figure 12. Load sample and inject sample from pump to loop.
Figure 13. Construction of high-performance liquid chromatography column.
Columns
Conventional liquid chromatography uses plastic or glass columns that can range from a few centimeters to several
meters. The most common lengths are 10-100 cm, with the longer columns finding a use for preparative-scale
separations. High-Performance Liquid Chromatography (HPLC) columns are stainless steel tubes, typically of 10-30
cm in length and 3-5 mm inner diameter. Short, fast analytical columns, and guard columns, which are placed
before an analytical column to trap junk and extend the lifetime of the analytical column, are 3 -10 cm long (Figures
14-16) [14,15].
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
10
Figure 14. High performance liquid chromatography column for preparative and analytical operation.
Figure 15. Picture of high-performance liquid chromatography column.
Figure 16. Picture of high-performance liquid chromatography column.
The column is the most important and sensitive part of HPLC. They are commercially available as microporous,
pellicular, and bonded phase types based on the physical and chemical nature of the packed stationary phase in
the column. They can withstand a pressure of 8000 psi. They are available in lengths of 20 to 50 cm and internal
diameters of 1 to 4mm. The particle size range is 5 to 30 microns but mostly lower sizes are preferred for better
separation. For reverse phase columns (i.e., the stationary phase is non-polar) C18 columns are used. While normal
phase columns (stationary phase is polar).
Guard columns: These are small columns with a similar stationary phase to that of columns. They are used to
prevent the passage of any particulate matter to prevent clogging and damage to the column (Figure 17) [16].
Figure 17. High performance liquid chromatography guard column.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
11
HPLC column components and specifications
Column dimension (size)
Particle size and pore size
Stationary phase
Column dimension (size): Since columns are tubular, column dimensions usually take the following format, internal
diameter X length (4.6 mm × 250 mm). Columns ranging in internal diameter from 0.050 to 4.6 mm are used or
even larger columns for performing large-scale preparative chromatography. This is an important fact that shorter
columns are generally cheaper and generate less back pressure. Why is less back pressure important? If a column
runs at low pressure, it allows the user more flexibility to adjust the flow rate. Sometimes shorter columns are used to
do fast chromatography at higher-than-normal flow rates. In termsof length, we routinely run 100 mm columns;
however, 50 mm or 30 mm columns may be adequate for many LC/MS separation needs.
Particle size and pore size: The most common columns are packed with silica particles. The beads or particles are
generally characterized by particle and pore size. Particle sizes generally range between 3 and 50 microns, with 5
µm particles being the most popular for peptides. Larger particles will generate less system pressure and smaller
particles will generate more pressure. The smaller particles generally give higher separation efficiencies. The
particle pore size is measured in angstroms and generally ranges between 100-1000 Å. 300 Å is the most popular
pore size for proteins and peptides and 100 Å is the most common for small molecules. Silica is the most common
particle material. Since silica dissolves at high pH, it is not recommended to use solvents that exceed pH 7.
However, recently some manufacturers have introduced silica-based technology that is more resistant to high ph. In
addition, the combination of high temperatures and extremes of pH can be especially damaging to silica [17].
Detector
This part of HPLC helps in the detection and identification of compounds in the sample. Based on the types they are
available as UV-Visible, Fluorescent, Electrochemical, and Photo diode- array detectors (Figure 18) [17].
Figure 18. High performance liquid chromatography detector.
These detectors are designed to have certain properties like
Being inert (non-reactive) to the sample injected and the mobile phases passing through
Preferably non-destructive to the sample
Produce a quick and quantitative response
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
12
Produce uniform, reliable and reproducible detection and analytic data.
Compatible with all types of compounds under testing (Table 1).
Table 1. Performance of HPLC detectors.
HPLC detector
Mass LOD (typical)
Linear range (decades)
Absorbance
10 pg.
3-4
Fluorescence
10 FG
5
Electrochemical
100 pg
4-5
Refractive index
1 ng
3
Conductivity
100 pg-1 ng
5
Mass
spectrometry
<1 pg.
5
FAIR
1 µg
3
Light scattering
1 µg
5
Optical activity
1 ng
4
Element selective
1 ng
4-5
Photoionization
<1 pg.
4
HPLC fluorescence detector
In this detector, the fluorescence rays emitted by the sample after absorbing incident light are measured as a
function of the quality and quantity of the sample. The equipment comprises accessories in order as a light source,
a sample passing through tubing exposed to rays, grating (for light refraction), a photocell, a charged conductor,
etc. detector that is suitable for compounds that can produce fluorescence. Some compounds are altered to
produce fluorescence by chemical derivatization to estimate by this detector. These detectors have high precision
and sensitivity (with less noise in data). Compounds are measurable till nanograms quantities.
HPLC electrochemical detector
This detector is especially suitable to estimate oxidizable and reducible compounds. The principle is that when the
compound is either oxidized or reduced, the chemical reaction produces electron flow. This flow is measured as the
current which is the function of the type and quantity of the compound. The system has electrodes like a working
electrode where oxidation or reduction takes place and a reference electrode that acts to subtract conductivity of
the mobile phase from that of the sample. This electrode is suitable for compounds that can't be assayed by a UV
detector especially due to their similarities in light absorption properties ex: monoamines. This detector has super
sensitivity which ranges till picograms measurement; so, a very minute quantity of compounds present in the
samples can be measured. This electrochemical detector produces severe noise or fluctuations in peaks. So, it is
tedious to work with when compared to other detectors.
Photo diode-array detector
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
13
They are quite versatile advances in computer technology since ~1985 have led to the development of Diode Array
instruments. They are Non-destructive and non-universal. DAD scans a range of wavelengths every second or a few
seconds. At each point in the chromatogram, one gets a complete UV-VIS spectrum detailed spectra for each peak
and each region of each peak can be obtained using a photo diode-array detector. A diode array permits qualitative
information to be obtained beyond simple identification by retention time. The best wavelength(s) can be selected
for actual analysis. Absorbance rationing at several wavelengths helps to decide whether the peak represents a
single compound or, in fact, a composite peak (Table 2) [18].
Table 2. Application of different detectors.
Sr.No.
Detector
Analytes
Solvent requirement
Comments
1
UV visible
detectors
Any with
chromospheres
UV-grade non-UV
absorbing solvents
Has a degree of selectivity
and is useful for many
HPLC application
2
Fluorescence
detectors
Fluorescent compound
UV-grade non-UV
absorbing solvents
Highly selective and
sensitive. Often used to
analyze derivatized
compound
3
Refractive index
detector
Compounds with a
different refractive
index to the mobile
phase
Cannot run mobile
phase gradients
Virtually a universal
detector but has limited
sensitivity
4
Conductivity
detector
Charged or polar
compound
The mobile phase
must be conducting
Excellent for ion exchange
methods
5
Electrochemic al
detector
Readily oxidized or
reduced compounds,
especially biological
samples
The mobile phase
must be conducting
Very selective and sensitive
6
Evaporative Light
Scattering
Detector (ELSD)
Virtually all compounds
Must use volatile
solvents and volatile
buffers
A universal detector that is
highly sensitive. Not
selective
7
Mass
spectrometer
detector
A broad range of
compounds
Must use volatile
solvents and volatile
buffers
Highly sensitive and is a
powerful 2-dimensional
analytical tool. Many
modes are available.
Needs trained operator
Applications of high-performance liquid chromatography
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
14
In addition, it is used for analyzing air and water pollutants, monitoring materials that may jeopardize occupational
safety or health, and monitoring pesticide levels in the environment. Federal and state regulatory agencies use
HPLC to survey food and drug products, for identifying confiscated narcotics, or to check for adherence to label
claims. High-Performance Liquid Chromatography (HPLC) is widely used in the pharmaceutical industry, food and
beverage industry, research and development, quality control, production process control, environmental analyses,
and clinical tests. Preparative HPLC refers to the process of isolation and purification of compounds. Important is
the degree of solute purity and the throughput, which is the amount of compound produced per unit of time. This
differs from analytical HPLC, where the focus is to obtain information about the sample compound. The information
that can be obtained includes identification, quantification, and resolution of a compound [18,19].
Purification: Purification refers to the process of separating or extracting the target compound from other (possibly
structurally related) compounds or contaminants. Each compound should have a characteristic peak under certain
chromatographic conditions. Depending on what needs to be separated and how closely related the samples are,
the chromatographer may choose the conditions, such as the proper mobile phase, to allow adequate separation to
collect or extract the desired compound as it elutes from the stationary phase. The migration of the compounds and
contaminants through the column needs to differ enough so that the pure desired compound can be collected or
extracted without incurring any other undesired compound.
Chemical separation: Chemical separations can be accomplished using HPLC by utilizing the fact that certain
compounds have different migration rates given a particular column and mobile phase. Thus, the chromatographer
can separate compounds (more on chiral separations) from each other using HPLC; the extent or degree of
separation is mostly determined by the choice of stationary phase and mobile phase [20].
CONCLUSION
HPLC is probably the most universal type of analytical procedure; its application areas include quality control,
process control, forensic analysis, environmental monitoring, and clinical testing. In addition, HPLC also ranks as
one of the most sensitive analytical procedures and is unique in that it easily copes with multi-component mixtures.
It has achieved this position as a result of the constant evolution of the equipment used in LC to provide higher and
higher efficiencies at faster and faster analysis times with constant incorporation of new highly selective column
packing. UPLC system provides high speed of analyses so a greater number of analyses can be performed in a
shorter amount of time thereby increasing sample throughput and better assay sensitivity. Analysis of operation
cost and sample throughput found UPLC cost advantageous over HPLC.
REFERENCES
1. Remington. The science and practice of pharmacy. 2009;1:599.
2. www.buzzle.com/articles/types-of-chromatography.html
3. Skoog et al. Fundamentals of analytical chemistry.2009;87:957.
4. www.boomer.org/c/p3/c03/c0305.html
5. www.hubages.com/hub/HPLC-instrumentation and HPLC detectors
6. Andrew Guzzetti. Reverse Phase HPLC Basics for LC/MS. 2001.
7. John W. Dolan. Column diameter, linear velocity, and column efficiency. 2009;28:4149.
8. Library for science chromatography online.org
9. www.shimadzu.com › ... › Liquid Chromatograph
10. Lloyd R. et al. High-performance gradient elution: The practical application of the linear-solvent-strength
model. 2006.
Research & Reviews: Journal of Pharmacy and Pharmaceutical Sciences e-ISSN: 2320-1215
JPPS | Volume 12| Issue 3|September, 2023
15
11. Ronald E Majors. Fast and ultrafast HPLC on sub-2 am porous particles Where do we go from here?
2006.
12. Xiang Y et al. Ultrahigh pressure liquid chromatography using elevated temperature. J Chromatogr. 2006;
1104:198202.
13. Horvath Cs, et al. Fast liquid chromatography, Investigation of operating parameters and the separation of
nucleotides on pellicular ion exchangers. Anal Chem. 1967;39:14221428.
14. G Vidyasagar. Instrumental methods of drug analysis. 2010;1.
15. AH Beckett, et al. Practical pharmaceutical chemistry. 1988;4:159.
16. A.V Kasturi, et al. A textbook of pharmaceutical analysis, Instrumental methods. 50.
17. GR Chatwal, et al. Instrumental methods of chemical analysis. 2023; 2.624.
18. Willard HH, et al. Instrumental methods of analysis. 1986;7:580-610
19. Swartz ME, et al. Ultra-performance liquid chromatography: Tomorrow’s HPLC technology today. Lab Plus
Int. 2004;18:6-9.
20. www.acdlabs.com/products/chrom_lab.
... Analytical method refers to the employment of a specific technique and precise step-by-step instructions in the qualitative, quantitative, or structural analysis of a sample for one or more analytes [2]. Analytical Methods are mainly classified into 2 types: Classical method & Instrumental method. ...
... 6. Expensive chemicals and solvents might be required by the current analytical techniques. It could also include laborious extraction and separation techniques, some of which might not be trustworthy [2]. ...
Article
The pharmaceutical industry is dedicated to consistently producing high-quality products at an optimal cost, necessitating the development of robust methodologies across various stages from formulation to commercialization. This review article delves into the critical aspects of designing and validating processes integral to pharmaceutical drug development. Emphasizing the importance of reliable analytical techniques, the review underscores their role in quality assessment of pharmaceutical samples. A cornerstone of pharmaceutical manufacturing is adherence to Good Manufacturing Practice (GMP) regulations, which mandates comprehensive documentation and validation of processes. From raw material procurement to final batch production, validation ensures adherence to quality standards throughout the manufacturing chain. The article meticulously examines the creation and validation of analytical methods, focusing on parameters including accuracy, specificity, and precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, robustness, and system suitability testing. These validation parameters are instrumental in routine and stability analyses, guaranteeing the reliability and quality of pharmaceutical products. By elucidating the intricate nuances of validation methodologies, this review contributes to the efficient operation of pharmaceutical companies and the continual advancement of drug development practices.
Article
Full-text available
A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5µ) at room temperature and UV detection at 267 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 2.37min. The above method was validated in terms of linearity, accuracy, precision, LOD, LOQ , interday, intraday , selectivity , range , stability and robustness in accordance with ICH guidelines.
Article
Higher productivity and faster analyses are two of the driving forces for continued improvement in high performance liquid chromatography (HPLC) column technology. Reduction in the average particle size of HPLC porous column packings below 2 μm has resulted in sub-1.0 min separations in the gradient and isocratic modes. In this instalment of "Column Watch", Ron Majors traces the development of particle technology from the beginning of HPLC to the present, discusses why small particles are desirable, and probes some of the difficulties to be encountered, including extracolumn band broadening, pressure restrictions, and instrumental considerations. Finally, he shows a wide variety of fast- and ultrafast applications examples from commercial products in the sub-2 μm range. Speculation on future directions in HPLC in particle technology concludes the column.
Article
Fast liquid chromatographic (LC) methods are important for a variety of applications. Reducing the particle diameter (d(p)) is the most effective way to achieve fast separations while preserving high efficiency. Since the pressure drop along a packed column is inversely proportional to the square of the particle size, when columns packed with small particles (<2 microm) are used, ultrahigh pressures (>689 bar) must be applied to overcome the resistance to mobile phase flow. Elevating the column temperature can significantly reduce the mobile phase viscosity, allowing operation at higher flow rate for the same pressure. It also leads to a decrease in retention factor. The advantage of using elevated temperatures in LC is the ability to significantly shorten separation time with minimal loss in column efficiency. Therefore, combining elevated temperature with ultrahigh pressure facilitates fast and efficient separations. In this study, C6-modified 1.0 microm nonporous silica particles were used to demonstrate fast separations using a temperature of 80 degrees C and a pressure of 2413 bar. Selected separations were completed in 30 s with efficiencies as high as 220,000 plates m(-1).
  • Skoog
Skoog et al. Fundamentals of analytical chemistry.2009;87:957.
Reverse Phase HPLC Basics for LC/MS
  • Andrew Guzzetti
Andrew Guzzetti. Reverse Phase HPLC Basics for LC/MS. 2001.
High-performance gradient elution: The practical application of the linear-solvent-strength model
  • R Lloyd
Lloyd R. et al. High-performance gradient elution: The practical application of the linear-solvent-strength model. 2006.
Fast liquid chromatography, Investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers
  • Horvath Cs
Horvath Cs, et al. Fast liquid chromatography, Investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers. Anal Chem. 1967;39:1422-1428.
Instrumental methods of drug analysis
  • G Vidyasagar
G Vidyasagar. Instrumental methods of drug analysis. 2010;1.