Improving detection of fMRI activation at 1.5 T using high permittivity ceramics

Authors:
To read the full-text of this research, you can request a copy directly from the authors.

Abstract

In this work, we propose an application of high permittivity materials (HPMs) to improve functional magnetic resonance imaging (fMRI) at 1.5 T, increasing the receive (Rx) sensitivity of a commercial multi-channel head coil. To evaluate the transmit efficiency, specific absorption rate (SAR), and the signal-to-noise ratio (SNR) changes introduced by the HPMs with relative permittivity of 4500, we considered the following configurations in simulation: a whole-body birdcage coil and an Rx-only multi-channel head coil with and without the HPM blocks in the presence of a homogeneous head phantom or a human body model. Experimental studies were also performed with a phantom and with volunteers. Seven healthy volunteers enrolled in a prospective study of fMRI activation in the motor cortex with and without HPMs. fMRI data were analyzed using group-level paired T-tests between acquisitions with and without HPM blocks. Both electromagnetic simulations and experimental measurements showed ∼25% improvement in the Rx sensitivity of a commercial head coil in the areas of interest when HPM blocks were placed in close proximity. It increased the detected motor cortex fMRI activation volume by an average of 56%, thus resulting in more sensitive functional imaging at 1.5 T.

No full-text available

Request Full-text Paper PDF

To read the full-text of this research,
you can request a copy directly from the authors.

ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
This article reviews recent developments in designing and testing new types of materials which can be: (i) placed around the body for in vivo imaging, (ii) be integrated into a conventional RF coil, or (iii) form the resonator itself. These materials can improve the quality of MRI scans for both in vivo and magnetic resonance microscopy applications. The methodological section covers the basic operation and design of two different types of materials, namely high permittivity materials constructed from ceramics and artificial dielectrics/metasurfaces formed by coupled conductive subunits, either in air or surrounded by dielectric material. Applications of high permittivity materials and metasurfaces placed next to the body to neuroimaging and extremity imaging at 7 T, body and neuroimaging at 3 T, and extremity imaging at 1.5 T are shown. Results using ceramic resonators for both high field in vivo imaging and magnetic resonance microscopy are also shown. The development of new materials to improve MR image quality remains an active area of research, but has not yet found significant use in clinical applications. This is mainly due to practical issues such as specific absorption rate modelling, accurate and reproducible placement, and acceptable size/weight of such materials. The most successful area has been simple “dielectric pads” for neuroimaging at 7 T which were initially developed somewhat as a stop-gap while parallel transmit technology was being developed, but have continued to be used at many sites. Some of these issues can potentially be overcome using much lighter metasurfaces and artificial dielectrics, which are just beginning to be assessed.
Article
Full-text available
Purpose The use of dielectric pads to redistribute the radiofrequency fields is currently a popular solution for 7 T MRI practical applications, especially in brain imaging. In this work, we tackle several downsides of the previous generation of dielectric pads. This new silicon carbide recipe makes them MR invisible and greatly extends the performance lifespan. Method We produce a set of two 10x10x1cm³ dielectric pads based on silicon carbide (SiC) powder dispersed in 4-Fluoro 1, 3-dioxalan-2-one (FEC) and polyethylene Glycol (PEG). The stability of the complex permittivity and the invisibility of the pads are characterized experimentally. Numerical simulations are done to evaluate global and local SAR over the head in presence of the pads. B0, B1⁺ and standard imaging sequences are performed on healthy volunteers. Results SiC pads are compared to state-of-the-art perovskite based dielectric pads with similar dielectric properties (barium titanate). Numerical simulations confirm that head and local SAR are similar. MRI measurements confirm that the pads do not induce susceptibility artefacts and improve B1⁺ amplitude in the temporal lobe regions by 25% on average. Conclusion We demonstrate the long-term performance and invisibility of these new pads in order to increase the contrast in the brain temporal lobes in a commercial 7 T MRI head coil.
Article
Full-text available
Ultra-high field MRI head coils present a characteristic B1⁺ magnetic field distribution resulting in inhomogeneous signal and contrast over the image, affecting relevant regions of interest such as the temporal lobes of the brain and the cerebellum. This is a consequence of the spatially varying flip angle distribution attributed to the reduction of the electromagnetic wavelength inside the human tissues. Without radical changes in the experimental setup, this problem has been effectively targeted by different passive RF shimming approaches such as high permittivity dielectric pads or metamaterials. The latter, however, may potentially decrease the B1⁺ field in other relevant areas or compromise the patient’s comfort. Here, we present a novel approach based on meander dipoles inspired from Hilbert fractals. The structures were designed and studied numerically using finite element simulations. Prototypes of the structures were printed and tested with a 1Tx/32Rx birdcage head coil on a 7 T MR scanner. We demonstrate a new device based on compact, thin and flexible design, able to improve the B1⁺ field over each temporal lobe without deterioration of the RF performances in other brain areas and with minimal impact on patient comfort.
Article
Full-text available
Purpose Radiofrequency field inhomogeneity is a significant issue in imaging large fields of view in high‐ and ultrahigh‐field MRI. Passive shimming with coupled coils or dielectric pads is the most common approach at 3 T. We introduce and test light and compact metasurface, providing the same homogeneity improvement in clinical abdominal imaging at 3 T as a conventional dielectric pad. Methods The metasurface comprising a periodic structure of copper strips and parallel‐plate capacitive elements printed on a flexible polyimide substrate supports propagation of slow electromagnetic waves similar to a high‐permittivity slab. We compare the metasurface operating inside a transmit body birdcage coil to the state‐of‐the‐art pad by numerical simulations and in vivo study on healthy volunteers. Results Numerical simulations with different body models show that the local minimum of B1+ causing a dark void in the abdominal domain is removed by the metasurface with comparable resulting homogeneity as for the pad with decreasing maximum and whole‐body SAR values. In vivo results confirm similar homogeneity improvement and demonstrate the stability to body mass index. Conclusion The light, flexible, and inexpensive metasurface can replace a relatively heavy and expensive pad based on the aqueous suspension of barium titanate in abdominal imaging at 3 T.
Article
Full-text available
Purpose To demonstrate that strategic use of materials with high electric permittivity along with integrated head‐sized coil arrays can improve SNR in the entire brain. Methods Numerical simulations were used to design a high‐permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30‐channel head coils of identical geometry were constructed: one fitted with a prototype helmet‐shaped ceramic HPM helmet, and the second with a helmet‐shaped low‐permittivity shell, each 8‐mm thick. An eight‐channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. Results Simulation results showed improvement in transmit efficiency by up to 65% and in receive‐side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive‐side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. Conclusion Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive‐side SNR throughout the brain by improving performance of a head‐sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
Article
Full-text available
Purpose One of the main concerns in fetal MRI is the radiofrequency power that is absorbed both by the mother and the fetus. Passive shimming using high permittivity materials in the form of “dielectric pads” has previously been shown to increase the B1+ efficiency and homogeneity in different applications, while reducing the specific absorption rate (SAR). In this work, we study the effect of optimized dielectric pads for 3 pregnant models. Methods Pregnant models in the 3rd, 7th, and 9th months of gestation were used for simulations in a birdcage coil at 3T. Dielectric pads were optimized regions of interest (ROI) using previously developed methods for B1+ efficiency and homogeneity and were designed for 2 ROIs: the entire fetus and the brain of the fetus. The SAR was evaluated in terms of the whole‐body SAR, average SAR in the fetus and amniotic fluid, and maximum 10 g‐averaged SAR in the mother, fetus, and amniotic fluid. Results The optimized dielectric pads increased the transmit efficiency up to 55% and increased the B1+ homogeneity in almost every tested configuration. The B1+‐normalized whole‐body SAR was reduced by more than 31% for all body models. The B1+‐normalized local SAR was reduced in most scenarios by up to 62%. Conclusion Simulations have shown that optimized high permittivity pads can reduce SAR in pregnant subjects at the 3rd, 7th, and 9th month of gestation, while improving the transmit field homogeneity in the fetus. However, significantly more work is required to demonstrate that fetal imaging is safe under standard operating conditions.
Article
Full-text available
Objective: The purpose of this work is to investigate the use of ceramic materials (based on BaTiO3 with ZrO2 and CeO2-additives) with very high relative permittivity (εr ∼ 4500) to increase the local transmit field and signal-to-noise ratio (SNR) for commercial extremity coils on a clinical 1.5 T MRI system. Methods: Electromagnetic simulations of transmit efficiency and specific absorption rate (SAR) were performed using four ferroelectric ceramic blocks placed around a cylindrical phantom, as well as placing these ceramics around the wrist of a human body model. Results were compared with experimental scans using the transmit body coil of the 1.5 T MRI system and an eight-element extremity receive array designed for the wrist. SNR measurements were also performed for both phantom and in vivo scans. Results: Electromagnetic simulations and phantom/in vivo experiments showed an increased in the local transmit efficiency from the body coil of ∼20-30%, resulting in an ∼50% lower transmit power level and a significant reduction in local and global SAR throughout the body. For in vivo wrist experiments, the SNR of a commercial eight-channel receive array, integrated over the entire volume, was improved by ∼45% with the ceramic. Conclusion: The local transmit efficiency as well as the SNR can be increased for 1.5 T extremity MRI with commercial array coils by using materials with very high permittivity.
Article
Full-text available
Developments in metamaterials and related structures such as metasurfaces have opened up new possibilities in designing materials and devices with unique properties. The main progress related to electromagnetic waves applications was done in optical and microwave spectra. Here we report about a new hybrid metasurface structure, comprising a two-dimensional metamaterial surface and a very high permittivity dielectric substrate that was designed to enhance the performance of an ultra-high field MRI scanner. This new flexible and compact resonant structure is the first one which can be integrated into a multi-element close-fitting receive coil array used for all clinical MRI. We successfully demonstrated the operation of the metasurface in acquiring vivo human brain images and spectra with enhanced local sensitivity on a commercial 7 Tesla system. These experimental findings prove the feasibility of real clinical applications of metasurfaces in MRI.
Article
Full-text available
Structure and electrical properties at radio frequencies as well as within the 3.5–35 GHz frequency range have been investigated for ceramic samples of the (1-y)(BaxSr1 - x)TiO3 · yMgO (BSM) system where x = 0.4–0.6; y = 0.15–0.30. For the compositions studied the bulk ferroelectrics were synthesized with the dielectric constant of 400–600 and high tunability coefficient. We indicated that the quality factor of the samples was in the range of 100–1000 within the frequency band of 3.5–35 GHz. The phase correlations and unit cell constants of the perovskite phase of the BSM samples were studied. The low loss factor and high tunability of the bulk material allowed us using the BSM ferroelectric ceramic layer for tunable accelerating structures of the Argonne Dielectric Wakefield Accelerator and for high power switches design and development for the future linear colliders.
Article
Full-text available
Despite there being an increasing number of installations of ultra high field MR systems (>3T) in clinical environments, no functional patient investigations have yet examined possible benefits for functional diagnostics. Here we performed presurgical localization of the primary motor hand area on 3T and 7T Siemens scanners with identical investigational procedures and comparable system specific sequence optimizations. Results from 17 patients showed significantly higher functional sensitivity of the 7T system measured via percent signal change, mean t-values, number of suprathreshold voxels and contrast to noise ratio. On the other hand, 7T data suffered from a significant increase of artifacts (ghosting, head motion). We conclude that ultra high field systems provide a clinically relevant increase of functional sensitivity for patient investigations.
Article
Full-text available
Presurgical mapping of motor function is a widely used clinical application of functional (f) MRI, employing the blood oxygenation level dependent contrast. The aim of this study was to report on 3 years experience of 194 fMRI studies on the representation of motor function in 103 patients and to describe the problems and artefacts that were typically present. An evaluation was carried out to determine whether the patients' age, type or location of the tumourous lesion, severity of the paresis, or the tasks used during the investigation have an effect on artefacts of fMRI studies and how these artefacts are best overcome. Functional MRI identified the motor regions in 85% of all investigated paradigms. In 11% of the investigated patients no information at all on functional localisation was obtained. A draining vein within the central sulcus was present in all patients that showed activation within the parenchyma of the precentral gyrus but also in three patients in whom no parenchymal activation was present. Head movement artefacts were the most frequent cause for fMRI failure, followed by low signal to noise ratio. Motion artefacts were correlated with the degree of paresis and with the functional task. Tasks involving more proximal muscles led to significantly more motion artefacts when compared with tasks that primarily involved distal muscles. Mean MR signal change during task performance was 2.5%. Most of the artefacts of functional MRI can be reliably detected and at least in part be reduced or eliminated with the help of mathematical algorithms, appropriate pulse sequences and tasks, and-probably most important-by evaluating the fMRI raw data-that is, the MR signal time courses.
Article
Full-text available
Drug development today needs to balance agility, speed and risk in defining the probability of success for molecules, mechanisms and therapeutic concepts. New techniques in functional magnetic resonance imaging (fMRI) promise to be part of a sequence that could transform drug development for disorders of the central nervous system (CNS) by examining brain systems and their functional activation dynamically. The brain is complex and multiple transmitters and intersecting brain circuits are implicated in many CNS disorders. CNS therapeutics are designed against specific CNS targets, many of which are unprecedented. The challenge is to reveal the functional consequences of these interactions to assess therapeutic potential. fMRI can help optimize CNS drug discovery by providing a key metric that can increase confidence in early decision-making, thereby improving success rates and reducing risk, development times and costs of drug development.
Article
Full-text available
A 32-channel 3T receive-only phased-array head coil was developed for human brain imaging. The helmet-shaped array was designed to closely fit the head with individual overlapping circular elements arranged in patterns of hexagonal and pentagonal symmetry similar to that of a soccer ball. The signal-to-noise ratio (SNR) and noise amplification (g-factor) in accelerated imaging applications were quantitatively evaluated in phantom and human images and compared with commercially available head coils. The 32-channel coil showed SNR gains of up to 3.5-fold in the cortex and 1.4-fold in the corpus callosum compared to a (larger) commercial eight-channel head coil. The experimentally measured g-factor performance of the helmet array showed significant improvement compared to the eight-channel array (peak g-factor 59% and 26% of the eight-channel values for four- and fivefold acceleration). The performance of the arrays is demonstrated in high-resolution and highly accelerated brain images.
Article
Limited detection power has been a bottleneck for subject-specific functional MRI (fMRI) studies; however, the higher signal-to-noise ratio afforded by ultra-high magnetic fields (≥7 Tesla) provides levels of sensitivity and resolution needed to study individual subjects. What may be surprising is that higher imaging resolution may provide both higher specificity and sensitivity due to reductions in partial volume effects and reduced physiological noise. However, challenges remain to ensure high data quality and to reduce variability in ultra-high field fMRI. We discuss session-specific biases including those caused by factors related to instrumentation, anatomy, and physiology—which can translate into variability across sessions—and how to minimize these to help ultra-high field fMRI reach its full potential for individual-focused studies.
Article
Resting state functional connectivity magnetic resonance imaging (rsfcMRI) has become a key component of investigations of neurocognitive and psychiatric behaviors. Over the past two decades, several methods and paradigms have been adopted to utilize and interpret data from resting-state fluctuations in the brain. These findings have increased our understanding of changes in many disease states. As the amount of resting state data available for research increases with big datasets and data-sharing projects, it is important to review the established traditional analysis methods and recognize areas where research methodology can be adapted to better accommodate the scale and complexity of rsfcMRI analysis. In this paper, we review established methods of analysis as well as areas that have been receiving increasing attention such as dynamic rsfcMRI, independent vector analysis, multiband rsfcMRI and network of networks.
Article
Background: There is growing interest in detecting cerebro-cerebellar circuits, which requires adequate blood oxygenation level dependent contrast and signal-to-noise ratio (SNR) throughout the brain. Although 7T scanners offer increased SNR, coverage of commercial head coils is currently limited to the cerebrum. Purpose: To improve cerebellar functional MRI (fMRI) at 7T with high permittivity material (HPM) pads extending the sensitivity of a commercial coil. Study type: Simulations were used to determine HPM pad configuration and assess radiofrequency (RF) safety. In vivo experiments were performed to evaluate RF field distributions and SNR and assess improvements of cerebellar fMRI. Subjects: Eight healthy volunteers enrolled in a prospective motor fMRI study with and without HPM. Field strength/sequence: Gradient echo (GRE) echo planar imaging for fMRI, turbo FLASH for flip angle mapping, GRE sequence for SNR maps, and T1 -weighted MPRAGE were acquired with and without HPM pads at 7T. Assessment: Field maps, SNR maps, and anatomical images were evaluated for coverage. Simulation results were used to assess SAR levels of the experiment. Activation data from fMRI experiments were compared with and without HPM pads. STATISTICAL TESTS: fMRI data were analyzed using FEAT FSL for each subject followed by group level analysis using paired t-test of acquisitions with and without HPM. Results: Simulations showed 52% improvement in transmit efficiency in cerebellum with HPM and SAR levels well below recommended limits. Experiments showed 27% improvement in SNR in cerebellum and improvement in coverage on T1 -weighted images. fMRI showed greater cerebellar activation in individual subjects with the HPM pad present (Z > = 4), especially in inferior slices of cerebellum, with 59% average increase in number of activated voxels in the cerebellum. Group-level analysis showed improved functional activation (Z > = 2.3) in cerebellar regions with HPM pads without loss of measured activation elsewhere. Data conclusion: HPM pads can improve cerebellar fMRI at 7T with a commonly-used head coil without compromising RF safety. Level of evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017.
Article
Layer-dependent fMRI allows measurements of information flow in cortical circuits, as afferent and efferent connections terminate in different cortical layers. However, it is unknown to what level human fMRI is specific and sensitive enough to reveal directional functional activity across layers. To answer this question, we developed acquisition and analysis methods for blood-oxygen-level-dependent (BOLD) and cerebral-blood-volume (CBV)-based laminar fMRI and used these to discriminate four different tasks in the human motor cortex (M1). In agreement with anatomical data from animal studies, we found evidence for somatosensory and premotor input in superficial layers of M1 and for cortico-spinal motor output in deep layers. Laminar resting-state fMRI showed directional functional connectivity of M1 with somatosensory and premotor areas. Our findings demonstrate that CBV-fMRI can be used to investigate cortical activity in humans with unprecedented detail, allowing investigations of information flow between brain regions and outperforming conventional BOLD results that are often buried under vascular biases.
Article
Purpose: Incorporating high dielectric constant (HDC) materials into radiofrequency (RF) coils has been shown to effectively improve RF coil performance at 7 and 3 T because of the induced displacement current in the high dielectric constant materials. The displacement current is proportional to the RF field frequency and permittivity of the material. The aim of this paper is to investigate the effect of high dielectric constant materials with even greater permittivity on the RF field at 1.5 T and 3 T. Methods: Several monolithic ceramic materials with an ultrahigh dielectric constant ranging from 1200 to 3300 were investigated at 1.5 T and 3 T with phantom and human brain imaging along with computer modeling. Results: Experimental measurements in phantom studies showed a significant enhancement of signal-to-noise ratio (50-100%) and strong transmission power reduction (3-27-fold). Under suboptimal experimental conditions in this study, the signal-to-noise ratio in the human brain cortex was nearly doubled, which produced high-resolution image without the associated stronger magnetic susceptibility artifacts and elevated specific absorption rate concerns at higher field strengths. Conclusions: Use of ultrahigh dielectric constant ceramic materials is a simple and low-cost approach that could further improve the RF technology to maximize image signal-to-noise ratio and reduce RF energy deposition for human studies. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Book
Although the field of Neuro-Oncology has grown considerably in the last 10 to 15 years and has a rather extensive literature, there are no comprehensive, single-source books that summarize the current literature and future trends of neuroimaging in neuro-oncology. This book covers this topic in more comprehensive fashion, making it an important addition to the armamentarium of physicians that care for patients with brain tumors and other neuro-oncological disorders. Well-founded in basic science, it includes chapters that provide an overview of relevant background material in critical areas such as physics, contrast agents, ultra-high field brain MRI, and molecular imaging.
Book
In an age where the amount of data collected from brain imaging is increasing constantly, it is of critical importance to analyse those data within an accepted framework to ensure proper integration and comparison of the information collected. This book describes the ideas and procedures that underlie the analysis of signals produced by the brain. The aim is to understand how the brain works, in terms of its functional architecture and dynamics. This book provides the background and methodology for the analysis of all types of brain imaging data, from functional magnetic resonance imaging to magnetoencephalography. Critically,Statistical Parametric Mappingprovides a widely accepted conceptual framework which allows treatment of all these different modalities. This rests on an understanding of the brain's functional anatomy and the way that measured signals are caused experimentally. The book takes the reader from the basic concepts underlying the analysis of neuroimaging data to cutting edge approaches that would be difficult to find in any other source. Critically, the material is presented in an incremental way so that the reader can understand the precedents for each new development. This book will be particularly useful to neuroscientists engaged in any form of brain mapping; who have to contend with the real-world problems of data analysis and understanding the techniques they are using. It is primarily a scientific treatment and a didactic introduction to the analysis of brain imaging data. It can be used as both a textbook for students and scientists starting to use the techniques, as well as a reference for practicing neuroscientists. The book also serves as a companion to the software packages that have been developed for brain imaging data analysis. * An essential reference and companion for users of the SPM software * Provides a complete description of the concepts and procedures entailed by the analysis of brain images * Offers full didactic treatment of the basic mathematics behind the analysis of brain imaging data * Stands as a compendium of all the advances in neuroimaging data analysis over the past decade * Adopts an easy to understand and incremental approach that takes the reader from basic statistics to state of the art approaches such as Variational Bayes * Structured treatment of data analysis issues that links different modalities and models * Includes a series of appendices and tutorial-style chapters that makes even the most sophisticated approaches accessible.
Article
Magnetic resonance imaging (MRI) is the cornerstone technique for diagnostic medicine, biology, and neuroscience. This imaging method is highly innovative, noninvasive and its impact continues to grow. It can be used for measuring changes in the brain after enhanced neural activity, detecting early cancerous cells in tissue, as well as for imaging nanoscale biological structures, and controlling fluid dynamics, and it can be beneficial for cardiovascular imaging. The MRI performance is characterized by a signal-to-noise ratio, however the spatial resolution and image contrast depend strongly on the scanner design. Here, we reveal how to exploit effectively the unique properties of metasurfaces for the substantial improvement of MRI efficiency. We employ a metasurface created by an array of wires placed inside the MRI scanner under an object, and demonstrate a giant enhancement of the magnetic field by means of subwavelength near-field manipulation with the metasurface, thus strongly increasing the scanner sensitivity, signal-to-noise ratio, and image resolution. We demonstrate experimentally this effect for a commercially available MRI scanner and a biological tissue sample. Our results are corroborated by measured and simulated characteristics of the metasurface resonator, and our approach can enhance dramatically functionalities of widely available low-field MRI devices.
Article
The appearance of severe signal drop-outs in abdominal imaging at 3 T arises primarily from areas of very low B 1+ transmit field in the body, and is problematic in both obese as well as very thin subjects. In this study, we show how thin patient-friendly pads containing new high permittivity materials can be designed and optimized, and when placed around the subject increase substantially the B 1+ uniformity and the image quality. Results from nine healthy volunteers show that inclusion of these dielectric pads results in statistically significant decreases in the coefficient of variance of the B 1+ field, with stronger and more uniform fields being produced. In addition there are statistically significant decreases in time-averaged power required for scanning. These differences are present in both quadrature-mode operation (coefficient of variance decrease, P < 0.0001, mean 25.4 ± 10%: power decrease, P = 0.005, mean 14 ± 14%) and also for the RF-shimmed case (coefficient of variance decrease, P = 0.01, mean 16 ± 13%: power decrease, P = 0.005, mean 22 ± 11%) of a dual-transmit system. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.
Article
The electrical properties of ceramic BaTiO3 were investigated by ac impedance spectroscopy over the ranges 25°-330°C and 0.03 Hz-1 MHz. Results are compared with those obtained from fixed-frequency measurements, at 1 kHz and 100 kHz. Fixed-frequency Curie-Weiss plots show deviations from linearity at temperatures well above tc. The ac measurements show that grain boundary impedances influence Curie-Weiss plots in two ways: at high temperatures, they increasingly dominate the fixed-frequency permittivities; at lower temperatures, closer to Tc, the high-frequency permittivity contains a contribution from grain boundary effects. Methods for extraction of bulk and grain boundary capacitances from permittivity and electric modulus complex plane plots are discussed. The importance of selecting the appropriate equivalent circuit to model the impedance response is stressed. A constriction impedance model for the grain boundary in BaTiO3 ceramics is proposed: the grain boundary capacitance is neither temperature-independent, nor shows Curie-Weiss behavior. The grain boundary is ferroelectric, similar to the grains, but its impedance is modified by either air gaps or high-impedance electrical inhomogeneity in the region of the necks between grains; the activation energy of the constriction grain boundary impedance differs from that of the bulk, suggesting differences in defect states or impurity levels.
Article
High permittivity materials find extensive use in high frequency communications devices due to their small size (compared to lumped element circuits), low losses and physical robustness. Recently, these types of materials have been applied in high field magnetic resonance imaging, based upon earlier work in electron paramagnetic resonance. This review article describes the basic properties of high permittivity materials, how they can be formed into both discrete resonators and also into deformable water-based suspensions, and how these different structures can be used to improve many aspects of high frequency magnetic resonance. © 2011 Wiley Periodicals, Inc. Concepts Magn Reson Part A 38: 148–184, 2011.
Article
Noise properties, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal responses were compared during functional activation of the human brain at 1.5 and 3.0 T. At the higher field spiral gradient-echo (GRE) brain images revealed an average gain in SNR of 1.7 in fully relaxed and 2.2 in images with a repetition time (TR) of 1.5 sec. The tempered gain at longer TRs reflects the fact that the physiological noise depends on the signal strength and becomes a larger fraction of the total noise at 3.0 T. Activation of the primary motor and visual cortex resulted in a 36% and 44% increase of “activated pixels” at 3.0 T, which reflects a greater sensitivity for the detection of activated gray matter at the higher field. The gain in the CNR exhibited a dependency on the underlying tissue, i.e., an increase of 1.8× in regions of particular high activation-induced signal changes (presumably venous vessels) and of 2.2× in the average activated areas. These results demonstrate that 3.0 T provides a clear advantage over 1.5 T for neuroimaging of homogeneous brain tissue, although stronger physiological noise contributions, more complicated signal features in the proximity of strong susceptibility gradients, and changes in the intrinsic relaxation times may mediate the enhancement. Magn Reson Med 45:595–604, 2001. © 2001 Wiley-Liss, Inc.
Article
Functional magnetic resonance imaging (fMRI) has become a popular tool for investigations into the neural correlates of cognitive activity. One limitation of fMRI, however, is that it has difficulty imaging regions near tissue interfaces due to distortions from macroscopic susceptibility effects which become more severe at higher magnetic field strengths. This difficulty can be particularly problematic for language tasks that engage regions of the temporal lobes near the air-filled sinuses. This paper investigates susceptibility-induced signal loss in the temporal lobes and proposes that by defining a priori regions of interest and using the small-volume statistical correction of K. J. Worsley, S. Marrett, P. Neelin, A. C. Vandal, K. J. Friston, and A. C. Evans (1996, Hum. Brain Mapp. 4: 58–83), activations in these areas can sometimes be detected by increasing the statistical power of the analysis. We conducted two experiments, one with PET and the other with fMRI, using almost identical semantic categorization paradigms and comparable methods of analysis. There were areas of overlap as well as differences between the PET and fMRI results. One anticipated difference was a lack of activation in two regions in the temporal lobe on initial analyses in the fMRI data set. With a specific region of interest, however, activation in one of the regions was detected. These experiments demonstrate three points: first, even for almost identical cognitive tasks such as those in this study, PET and fMRI may not produce identical results; second, differences between the two methods due to macroscopic susceptibility artifacts in fMRI can be overcome with appropriate statistical corrections, but only partially; and third, new data acquisition paradigms are necessary to fully deal with susceptibility-induced signal loss if the sensitivity of the fMRI experiment to temporal lobe activations is to be enhanced.
Article
High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness on the transmit radiofrequency fields for neuroimaging at 7 T. For a 5-mm thick pad, there is virtually no effect on the transmit field for relative permittivity values lower than ∼90. Significant improvements are found for values between 90 and ∼180. If the relative permittivity is increased above ∼180 then areas of very low transmit efficiency are produced. For a 1-cm thick pad, the corresponding numbers are ∼60 and ∼120, respectively. Based upon the findings, a new material (barium titanate, relative permittivity ∼150) is used to produce thin (∼5 mm) dielectric pads which can easily be placed within a standard receive head array. Experimental measurements of transmit sensitivities, as well as acquisition of T(2) - and T 2*-weighted images show the promise of this approach.
Article
Blood oxygenation level dependent (BOLD) signal changes occurring during execution of a simple motor task were measured at field strengths of 1.5, 3 and 7 T using multi-slice, single-shot, gradient echo EPI at a resolution of 1x1x3 mm(3), to quantify the benefits offered by ultra-high magnetic field for functional MRI. Using four different echo times at each field strength allowed quantification of the relaxation rate, R(2)* and the change in relaxation rate on activation, DeltaR(2)*. This work adds to previous studies of the field strength dependence of BOLD signal characteristics, through its: (i) focus on motor rather than visual cortex; (ii) use of single-shot, multi-slice, gradient echo EPI for data acquisition; (iii) co-registration of images acquired at different field strengths to allow assessment of the BOLD signal changes in the same region at each field strength. DeltaR(2)* was found to increase linearly with field strength (0.51+/-0.06 s(-1) at 1.5 T; 0.98+/-0.08 s(-1) at 3 T; 2.55+/-0.22 s(-1) at 7 T), while the ratio of DeltaR(2)*/R(2), which dictates the accessible BOLD contrast was also found to increase (0.042+/-0.002 at 1.5 T; 0.054+/-0.002 at 3 T; 0.084+/-0.003 at 7 T). The number of pixels classified as active, the t-value calculated over a common region of interest and the percentage signal change in the same region were all found to peak at TE approximately T(2)* and increase significantly with field strength. An earlier onset of the haemodynamic response at higher field provides some evidence for a reduced venous contribution to the BOLD signal at 7 T.
Article
We describe methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils. The approach is conceptually similar to phased array radar and ultrasound and hence we call our techniques the "NMR phased array." The NMR phased array offers the signal-to-noise ratio (SNR) and resolution of a small surface coil over fields-of-view (FOV) normally associated with body imaging with no increase in imaging time. The NMR phased array can be applied to both imaging and spectroscopy for all pulse sequences. The problematic interactions among nearby surface coils is eliminated (a) by overlapping adjacent coils to give zero mutual inductance, hence zero interaction, and (b) by attaching low input impedance preamplifiers to all coils, thus eliminating interference among next nearest and more distant neighbors. We derive an algorithm for combining the data from the phased array elements to yield an image with optimum SNR. Other techniques which are easier to implement at the cost of lower SNR are explored. Phased array imaging is demonstrated with high resolution (512 x 512, 48-cm FOV, and 32-cm FOV) spin-echo images of the thoracic and lumbar spine. Data were acquired from four-element linear spine arrays, the first made of 12-cm square coils and the second made of 8-cm square coils. When compared with images from a single 15 x 30-cm rectangular coil and identical imaging parameters, the phased array yields a 2X and 3X higher SNR at the depth of the spine (approximately 7 cm).
Article
To investigate the sensitivity dependence of BOLD functional imaging on MRI acquisition parameters in motor stimulation experiments using a finger tapping paradigm. Gradient-echo echo-planar fMRI experiments were performed at 1.5 T and 3.0 T with varying acquisition echo time and bandwidth, and with a 4 mm isotropic voxel size. To analyze the BOLD sensitivity, the relative contributions of BOLD signal amplitude and thermal and physiologic noise sources were evaluated, and statistical t-scores were compared in the motor area. At 1.5 T, the number of activated pixels and the average t-score showed a relatively broad optimum over a TE range of 60-160 msec. At 3.0 T, an optimum range was observed between TEs of 30-130 msec. Averaged over nine subjects, maxima in the number of pixels and t-score values were 59% and 18% higher at 3.0 T than at 1.5 T, respectively, an improvement that was lower than the observed 100% to 110% increase in signal-to-noise ratio at 3.0 T. The somewhat disappointing increase in t-scores at 3.0 T was attributed to the increased contribution of physiologic noise at the higher field strength under the given experimental conditions. At both field strengths, reducing the effective image acquisition bandwidth from 35 to 17 Hz per pixel did not affect or only marginally affect the BOLD sensitivity.
Article
For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-insensitive magnetization-reset sequence such that the choice of repetition time (TR) is independent of T(1) and with a multislice segmented (spiral) acquisition to achieve volumetric coverage with adequate spatial resolution in a few seconds. Phantom experiments confirmed the accuracy of this technique even when TR < T(1), with the side effect being lowered SNR. The speed of this method enabled B(1)+ mapping in the chest and abdomen within a single breath-hold. In human cardiac imaging, the method enabled whole-heart coverage within a single 16-s breath-hold. Results from phantoms and healthy volunteers at 1.5 T and 3 T are presented.
Article
Functional magnetic resonance imaging (fMRI) is widely used to detect and delineate regions of the brain that change their level of activation in response to specific stimuli and tasks. Simple activation maps depict only the average level of engagement of different regions within distributed systems. FMRI potentially can reveal additional information about the degree to which components of large-scale neural systems are functionally coupled together to achieve specific tasks. In order to better understand how brain regions contribute to functionally connected circuits, it is necessary to record activation maps either as a function of different conditions, at different times or in different subjects. Data obtained under different conditions may then be analyzed by a variety of techniques to infer correlations and couplings between nodes in networks. Several multivariate statistical methods have been adapted and applied to analyze variations within such data. An approach of particular interest that is suited to studies of connectivity within single subjects makes use of acquisitions of runs of MRI images obtained while the brain is in a so-called steady state, either at rest (i.e., without any specific stimulus or task) or in a condition of continuous activation. Interregional correlations between fluctuations of MRI signal potentially reveal functional connectivity. Recent studies have established that interregional correlations between different components of circuits in each of the visual, language, motor and working memory systems can be detected in the resting state. Correlations at baseline are changed during the performance of a continuous task. In this review, various methods available for assessing connectivity are described and evaluated.
Article
To exploit the high (millisecond) temporal resolution of magnetoencephalography (MEG) and electroencephalography (EEG) for measuring neuronal dynamics within well-defined brain regions, it is important to quantitatively assess their localizing ability. Previous modeling studies and empirical data suggest that a combination of MEG and EEG signals should yield the most accurate localization, due to their complementary sensitivities. However, these two modalities have rarely been explicitly combined for source estimation in studies of recorded brain activity, and a quantitative empirical assessment of their abilities, combined and separate, is currently lacking. Here we studied early visual responses to focal Gabor patches flashed during subject fixation. MEG and EEG data were collected simultaneously and were compared with the functional MRI (fMRI) localization produced by identical stimuli in the same subjects. This allowed direct evaluation of the localization accuracy of separate and combined MEG/EEG inverse solutions. We found that the localization accuracy of the combined MEG+EEG solution was consistently better than that of either modality alone, using three different source estimation approaches. Further analysis suggests that this improved localization is due to the different properties of the two imaging modalities rather than simply due to increased total channel number. Thus, combining MEG and EEG data is important for high-resolution spatiotemporal studies of the human brain.
  • J Yang
  • S Gohel
  • B Vachha
J. Yang, S. Gohel, B. Vachha, Current methods and new directions in resting state fMRI, Clin. Imaging 65 (2020) 47-53.
  • V Koloskov
  • M Zubkov
  • G Solomakha
V. Koloskov, M. Zubkov, G. Solomakha et al. Journal of Magnetic Resonance 348 (2023) 107390
Medical equipment IEC 60601-2-33: particular requirements for the safety of Magnetic resonance equipment
International Electrotechnical Commission, International standard, Medical equipment IEC 60601-2-33: particular requirements for the safety of Magnetic resonance equipment, third ed., IEC, Geneva, 2010.