Improving Hands-Free Speech Rehabilitation in Laryngectomized Patients: Preliminary Results of a Novel Intratracheal Fixation Device

Authors:
To read the full-text of this research, you can request a copy directly from the authors.

Abstract

Permanent hands-free speech with the use of an automatic speaking valve (ASV) is regarded as the optimal voice rehabilitation after total laryngectomy. Due to fixation problems, regular ASV use in laryngectomized patients is limited. We have developed a novel intratracheal fixation device (ITFD), composed of an intratracheal button augmented by a hydrophilic PVA foam exterior around its shaft. The aim of this study was to evaluate the ITFD’s feasibility in vitro, defined as an effective ASV fixation without causing mucosal tissue traumatization. We found that when the expanded PVA foam is compressed less than 60% of its original thickness, it can potentially provide both a safe and effective ASV fixation in a range of tracheostoma morphologies; enough fixation to withstand pressures related to loud speech (approximately 6 kPa) without exerting excessive pressure (>32 mmHg) which could lead to ischemic damage to the tracheal tissue. This study demonstrates the feasibility of the ITFD in vitro that might improve stomal attachment of ASVs. The ITFD’s deformable foam exterior may provide an effective fixation in most laryngectomized patients, compared to commercially available fixation methods, without the need for a user-specific customization. The results of a clinical feasibility study in laryngectomized patients are pending.

No full-text available

Request Full-text Paper PDF

To read the full-text of this research,
you can request a copy directly from the authors.

ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
Evaluation of short- and long-term clinical feasibility and exploration of limitations and advantages of a new automatic speaking valve (ASV) for laryngectomized patients with integrated HME, the Provox FreeHands FlexiVoice (FlexiVoice). This ASV not only enables automatic, but also manual closure of the valve. A multicenter, prospective clinical study in 40 laryngectomized patients was conducted. Participants were asked to use the FlexiVoice for 26 weeks. The primary outcome measure was long-term compliance. Secondary outcome measures were: patient preference, hours of FlexiVoice use, device life of adhesive, voice and speech quality, and quality of life. After 26 weeks, 15 patients (37.5 %) were using the FlexiVoice on a daily basis, for a mean of 12.64 h/day (SD ± 5.03). Ten patients (25 %) were using the device on a non-daily basis, for a mean of 3.76 h/day (SD ± 2.07). The remaining 15 patients (37.5 %) discontinued using the FlexiVoice. Sixty percent of the 25 long-term users applied both automatic and manual closure of the valve. Unpredictable fixation of the adhesive was the main reason for discontinuing or not using the FlexiVoice on a daily basis. Overall, 18 patients (45 %) preferred the FlexiVoice, 16 patients (40 %) their usual HME, 3 patients (7.5 %) their usual ASV, 1 patient (2.5 %) preferred no device at all, and in 2 patients preference was not recorded. The minor technical issues identified could be corrected. The Provox FreeHands FlexiVoice appears to be a useful ASV, which allows for hands-free speech in a larger proportion of laryngectomized patients in the present cohort. The additional manual closure option of the device is beneficial for maintaining the adhesive seal longer.
Article
Full-text available
This article reviews the mechanism, symptoms, causes, severity, diagnosis, prevention and present recommendations for surgical as well as non-surgical management of pressure ulcers. Particular focus has been placed on the current understandings and the newer modalities for the treatment of pressure ulcers. The paper also covers the role of nutrition and pressure-release devices such as cushions and mattresses as a part of the treatment algorithm for preventing and quick healing process of these wounds. Pressure ulcers develop primarily from pressure and shear; are progressive in nature and most frequently found in bedridden, chair bound or immobile people. They often develop in people who have been hospitalised for a long time generally for a different problem and increase the overall time as well as cost of hospitalisation that have detrimental effects on patient's quality of life. Loss of sensation compounds the problem manifold, and failure of reactive hyperaemia cycle of the pressure prone area remains the most important aetiopathology. Pressure ulcers are largely preventable in nature, and their management depends on their severity. The available literature about severity of pressure ulcers, their classification and medical care protocols have been described in this paper. The present treatment options include various approaches of cleaning the wound, debridement, optimised dressings, role of antibiotics and reconstructive surgery. The newer treatment options such as negative pressure wound therapy, hyperbaric oxygen therapy, cell therapy have been discussed, and the advantages and disadvantages of current and newer methods have also been described.
Article
Full-text available
In most patients with advanced or recurrent laryngeal or hypopharyngeal cancer, total laryngectomy is indicated. This means the loss of three main functions: phonation; respiration; and the prevention of aspiration during deglutition. Laryngectomy patients have various options to restore phonation: an oesophageal voice; an electrolaryngeal voice; or a tracheo-oesophageal voice. In the last case a silicone rubber shunt valve is placed in the tracheo-oesophageal wall and phonation is generated when exhaled air is forced through the oesophagus and neopharynx. This method is widely applied in Western Europe. In this paper we review the literature on fixation problems with shunt valves, tracheostoma valves and heat and moisture exchange (HME) filters. Tracheo-oesophageal speech without a valve is not considered. Despite 22 years of experience with the implantation of tracheo-esophageal shunt valves and many improvements in the design, problems still remain, such as biofilm formation with subsequent leakage through the valve, the need for frequent and inconvenient replacements, fistula enlargement leading to leakage around the device and reduced fixation, and infections. The high cost of shunt valves is a drawback to their use worldwide. To enable hands-free speech, different types of tracheostoma valve have been developed. These valves are fixed to the skin or to the tracheostoma by means of an intra-tracheal device. An HME filter is used to protect the airway and maintain physiological balance. Such devices are only suitable for a selected group of patients as fixation to the skin or trachea can be a major problem. Speaking and coughing cause pressure increases, which often result in mucous leakage and disconnection of the valve and/or HME filter. Recommendations are made for future improvements in fixation techniques.
Article
Full-text available
In laryngectomized patients, tracheoesophageal voice generally provides a better voice quality than esophageal voice. Understanding the aerodynamics of voice production in patients with a voice prosthesis is important for optimizing prosthetic designs and successful voice rehabilitation. To measure the aerodynamics and sound intensity in tracheoesophageal voice production. We built a special setup, which consisted of a Pentium 200 MHz computer with an AD-DA interface card and Labview 4.01 software. In an oral/nasal mask we constructed several mass flow sensors and a microphone. This measured both the oral airflow and the level of sound. For the measurement of endotracheal pressure, which is the driving force behind the airflow, we used a transducer which was connected to the tracheostoma. The endoesophageal pressure was measured at the level of the prosthesis in the esophagus by a Mikrotip transducer. Using this we could determine how much the voice prosthesis contributes to the overall pressure drop of the phonatory tract. Furthermore, the average airflow rate as a function of the sound pressure levels could be determined. In our population, 6 out of 7 patients showed a positive relationship between trans-source airflow and generated sound intensity. We compared our prosthesis pressure drop values with in vitro data and found that there are some differences, possibly due to difference in age of the prosthesis and physiological circumstances in vivo. The overall contribution of the voice prosthesis to the airway resistance depends on the level of phonation and the type of device. In our patient group it is apparent that the pharyngoesophageal (PE) segment has the greatest share of the total pressure drop, especially at higher airflow rates. We measured a 27% pressure drop in airflow over the voice prosthesis. Different tracheostoma occlusion methods did not have any effect on the aerodynamics and sound intensity. One patient that had had a jejunal graft for reconstruction showed, not unexpectedly, extremely different aerodynamic values. We were unable to define optimal airflow rates or optimal resistance values for sound production in the PE segment. The aerodynamic characteristics of voice production in laryngectomized patients with voice prostheses are determined by both prosthetic factors and PE segment tissue factors. In our patient group the PE segment is responsible for the greatest pressure drop. We found no significant difference in pressure drop and sound intensity for different tracheostoma occlusion methods.
Article
Objectives: Existing fixation methods of automatic speaking valves (ASVs) suffer from shortcomings which partly are the result of insufficient conformity of the intratracheal fixation method’s shape to the tracheostoma anatomy. However, quantitative data are lacking and will be helpful to analyse solutions for airtight fixation. This article provides such data. Patients and methods: The tracheostoma morphology was measured in computerized tomography scans of 20 laryngectomized patients. Measured were transverse and sagittal diameters, transition angle between skin level and tracheostoma lumen and between the tracheostoma lumen to the trachea, TE valve placement and stoma depth. Results: The mean transverse and sagittal diameters of the stoma at the peristomal lip are 19.2 mm [standard deviation (SD 5.2 mm)] and 17.6 mm (SD 5.3 mm), respectively. The mean transition angles are 84.5° (SD 15.6°) at skin level and 153.6° (SD 11.7°) into the trachea. The mean distance between TE valve and peristomal lip is 13.5 mm (SD 7.0 mm). The mean stoma depth is 14.0 mm (SD 6.4 mm). Conclusions: Due to the large variation, no ‘average tracheostoma morphology’, suitable for shaping a generic intratracheal fixation device, can be defined. Therefore, providing an airtight fixation in each patient would require a large range of different sizes, customization or a new approach.
Article
Clin. Otolaryngol. 2011, 36, 235–241 Objective: To determine the geometry of (peri)stomas of laryngectomised patients in relation to patch use. This data will enable improvement of tracheostoma interfaces, specifically addressing patients currently unable to use stoma patches. The low use of Heat-and-Moisture-Exchange (HME) filters and (hands-free) speech valves, although very important to the quality of life of laryngectomised patients, is mainly attributed to poor fit of the adhesive patches to the stoma site. Current patch shapes are not based upon an objective (peri)stoma geometry because this geometry is unknown. Design: Observational anthropometric study of the (peri)stoma of laryngectomised patients. Setting: Ten hospitals or institutes in eight countries. Participants: About 191 laryngectomised patients, at least 1 year post operative. Main outcome measures: (Peri)stomas were photographed and measured. Patients completed a questionnaire on patch-use. Concavity of commercially available patches was measured. Results: In countries with a financial reimbursement system 58% of the patients use patches, compares to only 9% in other countries. Patches stay in situ for an average of 33.3 h. Patch and non-patch users differ on five out of ten measured geometrical parameters. Most striking differences are that patch users have much shallower peristomas (13 versus 18 mm), and stomas far more parallel to the anterior neck plane. The deepest commercially available patch is only 7 mm deep. Conclusions: This study provides detailed (peri)stoma geometry data of a divers population, and for the first time in relation to patch-use. It reveals a serious mismatch between patients and patches. With these data new patches can be developed that could dramatically improve rehabilitation after laryngectomy.
Article
INTRODUCTION: Some patients suffering from laryngeal cancer have to be treated with a total laryngectomy. As part of their rehabilitation of voice, a shunt valve can be placed between the trachea and oesophagus. If the patient wants to speak, the stoma is closed with a finger or thumb to force expired air through the shunt valve into the oesophagus. Soft tissue at the top of the oesophagus starts to vibrate and thus functions as new vocal folds. Some of these patients use an automatic tracheostoma valve (ATV) on their stoma. This enables them to speak without using their hands. The department of Biomedical Engineering of the University Medical Centre Groningen has developed a new ATV. This new ATV can be automatically closed by inhalation, in contrast to the currently used exhalation valves. By this means the patient should be able to save more air for phonation. The hypothesis is that patients are able to speak longer and louder using the new automatic tracheostoma valve. METHODS: To verify these expectations, 14 patients were equipped with a prototype of the new inhalation valve and a commercially available exhalation ATV. For every patient the phonation time, loudness, frequency, intratracheal pressure and flow during speech were measured for both valves. After this, patients were asked to fill out a questionnaire about which valve they preferred. RESULTS: There is no significant difference found in the measured parameters between both valves, but most patients are of the opinion that the new valve is more easy to use. CONCLUSIONS: The new inhalation speech valve proves to be comparable to the existing speech valve. Further development will result in an optimal product, which could be better than existing automatic tracheostoma valves. KEYWORDS: laryngectomy, tracheostoma valve, speech valve, speech restoration
Article
With the use of a new automatic stoma valve (ASV) it appears possible to rehabilitate patients who have previously been unsuccessful in acquiring hands-free speech. As well as making daily ASV use possible for an additional group of patients, this new device was also appreciated by many patients as an additional rehabilitation tool for specific occasions. Despite statistically significant improvements in aspects of voice and breathing using this novel ASV, improvement of peristomal adhesion is probably the main factor needed to further increase success rates. Nevertheless, our results show that it makes sense to keep trying to achieve hands-free speech, even if previous attempts have failed. To make a long-term (6 months) assessment of compliance and aspects of voice, breathing and quality of life using a new ASV: the Provox FreeHands heat and moisture exchanger (HME). This was a prospective clinical multicentre trial in 79 laryngectomized patients (8 regular ASV users, 58 previously unsuccessful users and 13 new users). Data were collected at baseline and after 1 and 6 months by means of European Organization for Research and Treatment of Cancer Quality of Life questionnaires and specific structured questionnaires concerning compliance, skin adhesion, voicing and pulmonary aspects. An objective assessment of voice parameters (maximum phonation time, maximum phonation time while counting, dynamic loudness range and number of pauses in a standard read-aloud text) was made for comparison of different stoma occlusion methods (digital occlusion via an HME and two different ASVs). A subjective assessment of overall voice quality was made. After 6 months, 19% of patients used the new ASV on a daily basis (mean 5 h/day), while 57% used it on an irregular basis as an additional rehabilitation tool for special occasions. Two-thirds of the study group indicated that they would continue to use the new ASV after the study period. With respect to the objective parameters, statistically significantly better maximum phonation times and dynamic loudness ranges were observed with the new ASV compared to the Blom-Singer ASV. However, the best results for all the objective parameters were obtained with digital occlusion via the Provox HME.
Article
Excellent results have been reported with the use of voice prostheses for the rehabilitation of laryngectomees. Patients, however, consider it a disadvantage that the tracheostoma must be closed manually for speech production. This limits their ability to simultaneously communicate by gesture or to work with both hands. An automatic tracheostoma valve helps patients overcome this problem. We describe a prospective clinical trial evaluating our experience with the Provox FreeHands HME Automatic Tracheostoma Valve system. Twenty-four laryngectomees were randomly selected from the patients who had undergone laryngectomy at the ENT Department. Immediately, after 4 weeks and 6 months later having been fitted with a Provox FreeHands HME, the patients were asked to complete a questionnaire in order to assess their satisfaction, voice quality, wearing comfort, fixation, potential problems, and the effectiveness of the HME cassette. In addition, we investigated relevant voice quality parameters including dynamics range, frequency range of the speaking voice, and maximum phonation time. Seven patients discontinued the study due to problems of securing the valve to the skin (four patients) or recurrent cancer (three patients). Ten of the remaining 17 patients wore the valve daily for an average of 8.4 h. A total of 88% of the patients considered it a great advantage to be able to speak without having to use their hands. With the Provox FreeHands HME, maximum phonation time was 8.7 (+/-6.2) s and the dynamic range was 21.9 (+/-5.8) decibels. The results show that the Provox FreeHands HME Automatic Tracheostoma Valve system not only allows hands-free speech but is also associated with excellent compliance and good voice rehabilitation.
Article
This newly developed tracheostoma button and fixation system was appreciated by the majority of the patients in this study and led to an increased use of automatic speaking valves (ASVs). Development and prospective clinical evaluation of a new tracheostoma button and fixation system to enhance hands-free speech in laryngectomized patients. The Provox LaryButton and LaryClip adhesive system were prospectively evaluated in 11 patients: 10 male, 1 female; mean age 60.5 years, range 46-80 years; median follow-up since laryngectomy 4.9 years, range 9 months to 21 years. A study-specific questionnaire was used and the observation period was 3 weeks. Eight patients were compliant, three dropped out of the study. The LaryClip adhesive system was tried by seven of these compliant patients, and ultimately used by six. At the start of the study two patients used an ASV on a daily basis, three alternated between an ASV and regular, manually operated heat and moisture exchangers (HME), three only used a HME. At the end of the study, three used the ASV daily, five alternated between ASV and HME. Seven patients indicated that they would continue using the new system, six with clips and one with the button only.
Article
To compare the quality of life (QoL) of patients who underwent total laryngectomy with voice prosthesis insertion and postoperative radiotherapy (PORT) with those receiving concurrent chemoradiation for laryngeal preservation. Retrospective, cross-sectional study in a tertiary academic center. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaires were used to assess long-term QoL in 67 patients treated for laryngeal cancer. The scores of functional scales for physical (P < .000), social (P = .001), and role functioning (P = .043) were more favorable in the chemoradiation group. The global QoL score was higher in the nonsurgical group (P = .016). Surgical patients reported on sleep disturbance (P < .000), dyspnea (P = .001), and pain (P = .003), with a higher scores and greater difficulties with the senses (P < .000), social contact (P = .002) and speech (P = .010). The chemoradiation group reported greater problems with dry mouth (P < .000) and sticky saliva (P = .005). We found better long-term QoL scores in patients undergoing concurrent chemoradiation. This appears to be mainly because of better physical functioning, social functioning, and social contact and smaller problems with pain, respiration, speech, the senses, and sleep disturbances.
Synthetic Anatomy: A study into multi-material 3D printing and its application in prosthetics
  • J Goulding
  • S Crane
Goulding, J. and Crane. S., Synthetic Anatomy: A study into multi-material 3D printing and its application in prosthetics, INDN381, 2014.
Modification of the LaryButton for Tracheoesophageal Speech. The Journal of prosthetic dentistry
  • J S Lewin
Lewin, J.S., et al., Modification of the LaryButton for Tracheoesophageal Speech. The Journal of prosthetic dentistry, 2009. V001T12A001-5