We present LiFi channel measurements in a neurosurgery room of Motol University Hospital in Prague. Individual channels are combined into a virtual multiuser MIMO link. We report achievable data rates for different LiFi transmission schemes.
Content may be subject to copyright.
LiFi Experiments in a Hospital
Sreelal Maravanchery Mana1, Peter Hellwig1, Jonas Hilt1, Kai Lennert Bober1, Volker Jungnickel1
Klara Hirmanova2, Petr Chvojka3, Radek Janca3, Stanislav Zvanovec3
1Fraunhofer Institute for Telecommunications, Heinrich-Hertz Institute (HHI), Einsteinufer 37, 10587 Berlin, Germany
2Department of Medical Technology, Motol University Hospital, Prague 150 06, Czech Republic
3Faculty of Electrical Engineering, Czech Technical University in Prague, Prague 16627, Czech Republic
sreelal.maravanchery@hhi.fraunhofer.de
Abstract: We present LiFi channel measurements in a neurosurgery room of Motol University
Hospital in Prague. Individual channels are combined into a virtual multiuser MIMO link. We
report achievable data rates for different LiFi transmission schemes.
OCIS codes: (060.0060) Fiber optics and optical communications, (060.2605) Free-space optical communication
1. Introduction
The connected or smart hospital is widely considered as the future of healthcare, where all medical devices are
connected to a wireless infrastructure and provide accurate and timely information [1-4]. Aiming at safe and secure
wireless communication, the use of wireless local area networks such as WiFi in surgery environments is limited
due to possible electromagnetic interference (EMI). Hence, the deployment of a networked optical wireless
technology (LiFi), based on the light has the potential to be employed in hospital environments [2]. Recently,
several research groups provided insights into the potential of LiFi in healthcare environments [1-3]. For introducing
LiFi in hospitals, engineers need a fundamental understanding of the propagation scenario, i.e. the impact of
blockages and reflections by objects. Accordingly, robust transmission schemes need to be developed to enable
reliable wireless communication and high data rates. In this paper, we report for the first time on an experimental
investigation of LiFi transmission in a typical neurosurgery room. We recorded frequency responses of the optical
channels for various transmitter (Tx) and receiver (Rx) positions in the room and considered them subsequently as a
virtual multiuser multiple-input multiple-output (MU-MIMO) system. Finally, the achievable data throughputs for
possible LiFi transmission schemes are estimated.
2. Measurement Scenario
Fig. 1 shows the measurement scenario. Experiments were performed in the children neurosurgery room of Motol
University Hospital in Prague, Czech Republic. Fig. 1(a) shows the photo of the operating room, the positions of Rx
and Tx are highlighted in Figs. 1(b) and (c), respectively. The existing communication systems in this environment
are: i) body sensor network (BSN); ii) infrared (IR) navigation for precise position detection; iii) high-resolution
cameras for monitoring and recording the surgery and iv) endoscopes. Here, we investigate the performance of a
LiFi system employed in the operating room for downlink transmission of BSN. Tx and Rx are each fixed at six
different positions. All Rxs are placed on the operating table with 1 m height looking upwards to the ceiling where
the Txs are mounted at around 2 m height with a certain tilt looking downwards to the operating table. Multiple Rxs
represent multiple sensors, while multiple Txs are used in order to avoid possible blockage of the line-of-sight
(LOS) due to devices and humans moving inside the room.
Fig.1: Measurement Scenario: (a) Neurosurgical operating room; (b) Positions of Rx in the operating table; (c) Top view of the surgery room
where the Tx positions are marked in green color. Here Rx positions are marked in red
All measurements are conducted in the same static environment one after the other for each Tx-Rx link. Here, the
conventional frequency sweep technique is adopted [5]. A standard Agilent vector network analyzer (VNA
E5061B3L5) is connected between Tx and Rx feeding a continuous wave signal with variable frequency from 1 to
200 MHz. For characterizing each channel, the optical frontend response is calibrated out, which is measured at a
minimum distortion-free distance in free LOS [6]. All the channel responses and channel parameters are calculated
as given in [6].
3. Channel Characterization
From the experimental data, it is observed that the signal strength is weaker with respect to all Rx when using Tx1
and Tx2. Tx1 is often blocked by a monitor while Tx2 is too far away from the operating table. Here, we report only
channel characteristics of the other four Tx positions with respect to each Rx position. The measured magnitude
responses of the channels are shown in Fig. 2(a).
Rx1 and Rx2 are placed at the head position of the patient which has good visibility and free LOS from Tx5 and
Tx3. Similarly, Rx4 and Rx5 are nearby the leg position of the patient, where Tx4 and Tx6 have good signal
strength. The amplitude responses for Rx3 and Rx6 are always between the maximum and minimum response, since
they are located at the center position of the operating table. The initial drop at the lower frequencies of the
amplitude response indicates that there are many diffuse reflections in the surgery room where all objects have
bright colors (see Fig. 1(a)). Flatness at higher frequencies is due to the presence of the LOS.
4. MU-MIMO scenario
In our architecture, we assume that all transmitters are coordinated from a central unit which enables simultaneous
transmissions from multiple transmitters, i.e. spatial diversity to prevent sudden blockages of the LOS. Moreover,
joint scheduling of multiple user transmissions is possible in the space and time domains. The MU-MIMO link is
commonly characterized by using the singular values of the compound channel matrix H, which contains all the
links between all Txs and all Rxs. The singular values of H are plotted in Fig. 2(b) which shows that 2 of them are
much stronger than the two others. This suggest that at least 2 data streams can be spatially multiplexed, i.e.
transmitted in parallel, in our specific scenario. Figs. 2(c) shows the normalized channel gains at 1 MHz between all
Txs and all Rxs, and indicates that each Rx has at least 2 strong Tx links. Fig. 2(d) confirms our expectation that the
delay spread is low if the path gain is high and vice versa. From our observations, it is intuitive that Tx3 and Tx5
send a first data stream to Rx1 or Rx2. At the same time, Tx4 and Tx6 send a second data stream to Rx3, Rx4, Rx5
or Rx6. In this way, each Rx has data signals coming from two Txs and potential interference from two other Txs.
This ensures reliable transmission as one LOS could be blocked while the transmission is ongoing.
5. MU-MIMO results
Now we assume three possible transmission schemes and evaluate the achievable throughput. By assuming equal
transmit power, the signal to interference noise ratio (SINR) is calculated for each Rx by using the magnitude
response of the channel. For estimation of SINR, however, noise power is unknown. The maximum SNR that can be
achieved using our frontend design is 45 dB. Hence, we assumed a constant noise floor at a level which is 45 dB
Fig. 2: Results: (a) Magnitude response of channels for each Tx; (b) Singular values of 4x6 distributed MIMO; (c) Normalized gain at 1
MHz. Here first maxima indicated as X and second maxima as O; (d) Normalized delay spread of the channel
below the maximum magnitude response of the LiFi system measured at the minimum distortion-less distance. From
the estimated SINR, the throughput TP of each individual Rx is calculated by means of a modified Shannon formula
TP=B*log2(1+SINR/
) where B is the bandwidth and
=10 is assumed taking imperfect constellation shaping,
limited code word length and limited modulation index to avoid clipping into account. Note that the above formula
is applied on each frequency and then summation is applied over the entire bandwidth, i.e. 200 MHz.
The first scheme is classical time-division multiple access (TDMA) where each user is assigned one out of six
exclusive time slots and served by its best two Txs. In the second scheme, TDMA is extended by space division
multiple access (SDMA) where half of the time in a particular time slot is scheduled for Rx1 and Rx2 in order to
receive first data stream from Tx3 and Tx5 and other Rx has simultaneously one by fourth of the time to receive the
signals from Tx4 and Tx6. Thus, an interference term is included in the SINR calculation depending on the selected
Txs and Rx. Finally, the zero forcing (ZF) method has been applied after the same scheduling used in the TDMA-
SDMA approach. Note that the effective MIMO channel gain matrix in each time slot is given as 2x2 matrix. A
Moore-Penrose pseudo-inverse of the channel gain matrix is calculated as in [7]. All elements of the inverse matrix
are normalized with respect to the row norm to avoid the power fluctuations and send with equal power to each user.
Here the ZF is computed in each time slot and it executes the channel inversion for removing the interference. Note
that, Rx1 and Rx2 have higher throughput since they are available for longer time with stronger signals.
Fig. 3 shows the estimated throughput of the investigated configurations. From Fig. 3(a) it is clear that the ZF
method brings a significant improvement in the throughput for each Rx. For Rx3 and Rx6, TDMA method is much
better than SDMA and TDMA due to high interference from the other sources. The total throughput of the system is
shown in Fig. 3(b). We can observe that the throughput of the system with ZF is around two times higher than
TDMA alone and 1.5 times higher compared to the interference limited case.
5. Conclusion
In this paper, we report the first experimental study of LiFi system in a medical scenario. The frequency response of
the LiFi channels were measured in a neurosurgical operating room and corresponding channel parameters were
calculated. By considering all measured channels as a virtual distributed MU-MIMO system, multiplexing schemes
such as i) TDMA; ii) TDMA-SDMA and iii) TDMA-SDMA with ZF were considered and the achievable
throughputs were estimated. We observed that TDMA-SDMA with ZF provides the highest possible throughput.
6. Acknowledgement
The authors acknowledge the Department of Neurosurgery, 2nd Faculty of Medicine, Charles University in Prague
and Motol University Hospital, Prague, Czech Republic for all the provided help during experiments. This research
is funded by the VisIoN, a European Union’s H-2020 MSCA ITN program under the grant agreement no 764461.
7. References
[1] Y.K. Cheong et al., “Hazardless biomedical sensing data transmission using VLC,” IEEE Sensors J., vol. 13, no. 9,pp. 33473348, Sep. 2013.
[2] L. Chevalier et al., "Optical Wireless Links as an Alternative to Radio-Frequency for Medical Body Area Networks," JSAC, vol.33, no.9,
pp.2002-2010, Sept. 2015.
[3] S. S. Torkestani et al., “Indoor optical wireless system dedicated to healthcare application in a hospital,” IET Commun., vol. 6, no. 5, pp. 541
547, Mar. 27, 2012.
[4] R. Murai et al., "A novel visible light communication system for enhanced control of autonomous delivery robots in a hospital," SII,
IEEE/SICE International Symposium on, pp. 510-516, Fukuoka, 16-18 Dec 2012.
[5] J. M. Kahn et al., "Experimental characterization of non-directed indoor infrared channels," in IEEE Transactions on Communications, vol.
43, no. 2/3/4, pp. 1613-1623, 1995.
[6] S. M. Mana et al., "Experiments in Non-Line-of-Sight Li-Fi Channels," 2019 Global LIFI Congress (GLC), Paris, France, 2019, pp. 1-6.
[7] Q. H. Spencer et al., “Zero-forcing methods for downlink spatial multiplexing in multiuser MIMO channels,” IEEE Trans. Signal Proc ess.,
vol. 52, no. 2, pp. 461471, 2004.
Fig. 3 Results: (a) Throughput of each Rx at 10 MHz; (b) Total throughput of the system at different transmission schemes at 10 MHz
... The proposed prototype uses a Fiber Bragg Grating (FBG) sensor carried by a patient and Li-Fi receiver may be installed in ceiling of room for wireless transfer of vital signs of patient to cloud [32] [33], central monitoring unit or anywhere hospital administration deems suitable. In work [34], the researchers examined the implementation of Li-Fi in a typical neurosurgery operation room of a hospital. Researcher examined various locations for transmitter and receiver for best wireless communication using Li-Fi as shown in Figure 3 [34]. ...
... In work [34], the researchers examined the implementation of Li-Fi in a typical neurosurgery operation room of a hospital. Researcher examined various locations for transmitter and receiver for best wireless communication using Li-Fi as shown in Figure 3 [34]. Interference (EMI). ...
Article
Full-text available
This paper aims to show that Li-Fi now reached a state, where it can be considered a reliable wireless communication solution for future technologies. Currently, the Internet can be accessed using Wi-Fi, but it has its limitations too. It is sufficient for current Internet services but insufficient with IoT and cloud-based services. In the upcoming decade, hard drives will be obsolete and everything will be on the cloud. Modern Web applications i.e., 4K & 8K videos, games, high-resolution photos, etc. require fast bandwidth. Li-Fi opens a reliable door for the end-users to access future technology-based services at high speed.
... The investigation of MIMO transmission in VLC systems has attracted great attention recently, such as angular diversity-based detection [18], coverage analysis [19], transceiver design [20,21], and neural network-based joint spatial and temporal equalization [22]. So far, many experimental MIMO-VLC systems have been reported in the literature, such as a Gbit/s MIMO-VLC system using orthogonal frequency division multiplexing (OFDM) [23], a 50-Mbit/s MIMO-VLC system using on-off keying (OOK) [24], a pairwise coding-enhanced MIMO-VLC system [25], and the application of MIMO-VLC in a hospital [26,27]. Moreover, considering that there might be multiple users within the MIMO-VLC system, the design of an efficient multiple access scheme for multi-user MIMO-VLC (MU-MIMO-VLC) systems is of practical significance. ...
... In this subsection, we derive the OPA strategy for each UP in the MU-MIMO-VLC system using hybrid 3DMA. By substituting (25) and (26) in to (28), the achievable sum rate of the two users in UP i,w i is given by (29), which is shown on the top of the next page. By denoting C 1 = eγ tx 2π , ...
Article
Full-text available
In this paper, we propose and investigate a hybrid three-dimensional multiple access (3DMA) scheme for multi-user multiple-input multiple-output visible light communication (MU-MIMO-VLC) systems that can fully exploit the 3D resources of the system including frequency, space, and power. Particularly, all users in the MU-MIMO-VLC system applying hybrid 3DMA are first divided into multiple user groups (UGs) in the spatial domain, and users within each UG are further divided into multiple user pairs (UPs) in the frequency domain. In each UP, two users are multiplexed in the power domain via superposition coding. Due to the efficient 3D resource allocation in the MU-MIMO-VLC system applying hybrid 3DMA, the available bandwidth of each user can be substantially increased. Moreover, the impact of error propagation caused by imperfect successive interference cancellation (SIC) is considered, and the optimal power allocation (OPA) strategy is also derived to maximize the achievable sum rate of each UP. The feasibility and superiority of the proposed hybrid 3DMA with OPA have been successfully verified by the obtained analysis and simulation results. It is shown that the achievable average sum rate of an indoor 4×44 \times 4 4 × 4 MU-MIMO-VLC system can be substantially improved by applying the proposed hybrid 3DMA with OPA, in comparison to benchmark schemes such as orthogonal frequency division multiple access and space division multiple access. Moreover, it is further revealed that hybrid 3DMA with OPA exhibits high tolerance against imperfect SIC induced error propagation, which also shows excellent robustness and performance consistency to support multiple randomly located users.
... The application of VLC systems in hospitals is a paradigm that has evolved and has gained greater importance over time. Some research refers to its implementation, as in the article presented in [7], which discusses the use of VLC in hospitals to provide Li-Fi as a type of connection. This article reports on an experimental transmission study in a typical neurosurgery room. ...
Conference Paper
Full-text available
This article investigate the deployment of effective communication networks for smart IoT-based smart patient monitoring in medical facilities, advocating for the adoption of Visible Light Communication (VLC) technology. Initially, the physical scenario is analyzed, taking into account factors such as line-of-sight (LOS) and nonline-of-sight (NLOS) channel components. Furthermore, a transmitter is designed to offer a substitute in the event of potential interruptions due to patient motion or loss of line-of-sight elements. The performance of the proposed system is verified under certain performance metrics, such as the Channel Impulse Response (CIR) and the Cumulative Distribution Function (CDF), with respect to power measurements at different points. The results highlight the effects that NLOS rays have on the received data and the received power. Therefore, this study serves as a step towards the development of more sophisticated systems for patient monitoring using enabling technologies such as VLC.
... The Wi-Fi monitoring technique is slower and offers less bandwidth than Li-Fi. Due to the fact that Wi-Fi uses radio frequency waves, there is a high possibility that these waves could harm human body [2]. To overcome this problem, this paper proposing a framework that employing Li-Fi technology in healthcare field, the proposed framework is based on transmitting information ...
Chapter
Full-text available
Light Fidelity (Li-Fi) is an emerging technology that has been in transferring data packets in the Internet of Things (IoT) applications. During the COVID-19 pandemic, most healthcare institutes around the world try to manage the rapid may not have the ability to clock with the conventional sight techniques. During the era of Internet, communication becomes quick, secure and reliable through wired and wireless networks. Wireless networks have become more relevant in general domestic applications as well as health care applications. In this paper, a healthcare monitoring framework to exchange health data between bio-sensors and terminals by employing Li-Fi technology is proposed; The proposed framework exploits Li-Fi technology to transmit data packets towards network terminal and then to a cloud platform. It is intended for use in highly dense healthcare institutes where the number of patients is high. Exploiting the Li-Fi transmitting technology to establish connection avoids the need for the high cost of other transmission technologies such as Wi-Fi and provides less complexity in terms of network configuration and shorter end-to-end latency. We evaluate the proposed framework in a real-life environment using bio-Fi communication model (for network infrastructure), these two components are connected to a computing terminal to help health staff monitor patients, in addition, the computing terminal is connected to a cloud platform to allow remote monitoring and provides more computing resilience. The proposed framework shows superior performance in real-world scenarios compared to conventional communication medium (Wi-Fi), additionally, a comprehensive analysis has been conducted to show the differences between the two selected transmitting technologies (Li-Fi and Wi-Fi). Since Li-Fi uses infrared and visible light spectrum
... The Wi-Fi monitoring technique is slower and offers less bandwidth than Li-Fi. Due to the fact that Wi-Fi uses radio frequency waves, there is a high possibility that these waves could harm human body [2]. To overcome this problem, this paper proposing a framework that employing Li-Fi technology in healthcare field, the proposed framework is based on transmitting information ...
Article
Full-text available
Light Fidelity (Li-Fi) is an emerging technology that has been in transferring data packets in Internet of Things (IoT) applications. During the COVID-19 pandemic, healthcare institutes try to manage the rapid increase of patients’ numbers. The healthcare team may not have the ability to monitor patients’ stats around the clock with the conventional techniques. In this paper, a healthcare monitoring framework to exchange health data between biosensors and terminals employing Li-Fi technology is proposed. It exploits Li-Fi to transmit data towards a terminal then to a cloud platform. It is intended for use in highly dense healthcare institutes where the number of patients is high. Exploiting Li-Fi to establish connection to cut high cost of other transmission technologies including Wi-Fi and provides less complexity and shorter latency. We evaluate the framework in a real-life environment using biosensors and Li-Fi communication model (for network infrastructure), these two components are connected to a computing terminal to help health staff monitor patients. The computing terminal is connected to a cloud platform to provide remote monitoring and computing resilience. The framework shows superior performance in real-world scenarios compared to Wi-Fi. A comprehensive analysis has been conducted to show the differences between Li-Fi and Wi-Fi.
Conference Paper
Full-text available
This paper presents a systematic experimental study of non-line-of-sight (NLOS) communication channels for a networked mobile optical communication system denoted as Li-Fi. The experimental setup uses high-power light-emitting diodes (LEDs) with wide beam at the transmitter (Tx) and large-area photodiodes (PDs) with wide field-of-view (FOV) at the receiver (Rx). A continuous-wave frequency-sweep based on a vector network analyzer (VNA) yields amplitude and phase responses of the Li-Fi channel at modulation frequencies of up to 200 MHz. Our experiments indicate that IR LEDs compared to white LEDs yield a gain of roughly 10 dBel and a significantly higher bandwidth. Moreover, NLOS signals are found between 25-37 dBel below LOS signals at the same Tx-Rx distance. Finally, NLOS signals have low-pass characteristics in general with a reduced cutoff frequency. Implications of these findings on the design of a mobile Li-Fi system are highlighted.
Article
Full-text available
The use of space-division multiple access (SDMA) in the downlink of a multiuser multiple-input, multiple-output (MIMO) wireless communications network can provide a substantial gain in system throughput. The challenge in such multiuser systems is designing transmit vectors while considering the co-channel interference of other users. Typical optimization problems of interest include the capacity problem - maximizing the sum information rate subject to a power constraint-or the power control problem-minimizing transmitted power such that a certain quality-of-service metric for each user is met. Neither of these problems possess closed-form solutions for the general multiuser MIMO channel, but the imposition of certain constraints can lead to closed-form solutions. This paper presents two such constrained solutions. The first, referred to as "block-diagonalization," is a generalization of channel inversion when there are multiple antennas at each receiver. It is easily adapted to optimize for either maximum transmission rate or minimum power and approaches the optimal solution at high SNR. The second, known as "successive optimization," is an alternative method for solving the power minimization problem one user at a time, and it yields superior results in some (e.g., low SNR) situations. Both of these algorithms are limited to cases where the transmitter has more antennas than all receive antennas combined. In order to accommodate more general scenarios, we also propose a framework for coordinated transmitter-receiver processing that generalizes the two algorithms to cases involving more receive than transmit antennas. While the proposed algorithms are suboptimal, they lead to simpler transmitter and receiver structures and allow for a reasonable tradeoff between performance and complexity.
Conference Paper
Control systems for Autonomous mobile delivery robots have been described before. However, the control they provide is limited, leaving potential for serious errors. The current mobile robot systems concentrate on position accuracy and operational function but leave open management of safety hazards such as entering the dangerous and not intended areas as stairway. In order to increase the safety of the robot, it is as important to work with sensors installed in the external environment as the sensors installed on the robot. For this purpose, visible light communication (VLC) is a promising device to be used with the robot system. VLC creates an in-house GPS system by installing special LED lights that can replace standard lighting in key locations in the hospital. We have developed an in-hospital transportation robot, called HOSPI in which the control system has been enhanced by combining the navigational sensors of the robot and a VLC using installed lighting in the building. By using VLC, robots can obtain more information about the environment. As the first step for the practical application of VLC to robot system, we use VLC to overcome problems in conventional localization approaches, and to provide an additional line of defense in the case of catastrophic failures. This paper also describes experimental and actual operational results in detail of robots equipped, in an actual hospital, with the described process.
Article
The implementation of radio-frequency communication technologies in biomedical or healthcare applications involves multiple issues such as interference with precision medical instruments and human health hazard because of electromagnetic waves. A novel visible light communication technology for transmitting and monitoring biomedical data is presented. White beam light emitting diodes are used as optical information emitters for efficiently transmitting biomedical data such as patient information text and wavelike body sensor signals. ON/OFF keying modulation is used to modulate the data onto the visible light beam, and a high-speed p-i-n photo-detector is employed at the receiver. Experimental analysis of the data collected using this system demonstrates the effectiveness of the proposed method.
Article
We have experimentally characterized nondirected indoor channels that use intensity modulation and direct detection of an infrared carrier at a wavelength of 832 nm. At several locations in each of five different rooms, we have studied line-of-sight and diffuse link configurations, with and without shadowing, amounting to a total of approximately 100 different channels. We have measured channel frequency responses over the 2-300 MHz range by using a swept-modulation frequency technique, and from these data, we have computed channel impulse responses, path losses and r.m.s. delay spreads. Using channel impulse responses, we have calculated power penalties induced by multipath intersymbol interference in baseband on-off-keyed links operating at bit rates of 10, 30 and 100 Mb/s, considering unequalized links and those employing zero-forcing decision-feedback equalization. Unshadowed line-of-sight configurations generally have smaller path losses, r.m.s. delay spreads and power penalties than their unshadowed diffuse counterparts. Shadowed line-of-sight configurations, however, generally exhibit larger values of all three parameters than the corresponding shadowed diffuse configurations. We show that among the channels measured here, there is a strong correspondence between channel r.m.s. delay spread and multipath power penalty. Finally, we provide an analysis indicating why non-directed infrared channels using intensity modulation and direct detection do not exhibit multipath fading, and justifying their representation as linear, time-invariant systems
Conference Paper
In this paper indoor wireless Infrared (IR) technology for patient monitoring is studied. Monitoring provides a continuous and reliable vital sign measurement to secure patient staying in the hospital. As patient moving is inevitable, we focus on a mobile IR channel. We study the Line of Sight propagation with an OOK modulation system. A model of mobile channel is developed through the study of statistical distributions of the indoor distance between transmitter and receiver. We consider two mobility schemes, one in 2 dimensions (2D) for a fixed transmitter height and another in 3D. From the statistical analysis, the outage probability is calculated in order to evaluate the performance for different data rates and for high quality of service before concluding on the reliability of mobile monitoring.
Experiments in Non-Line-of-Sight Li-Fi Channels
  • S M Mana
S. M. Mana et al., "Experiments in Non-Line-of-Sight Li-Fi Channels," 2019 Global LIFI Congress (GLC), Paris, France, 2019, pp. 1-6.
Results: (a) Throughput of each Rx at 10 MHz; (b) Total throughput of the system at different transmission schemes at 10 MHz
  • Q H Spencer
Q. H. Spencer et al., "Zero-forcing methods for downlink spatial multiplexing in multiuser MIMO channels," IEEE Trans. Signal Process., vol. 52, no. 2, pp. 461-471, 2004. Fig. 3 Results: (a) Throughput of each Rx at 10 MHz; (b) Total throughput of the system at different transmission schemes at 10 MHz