Service providers relay on different technologies such as Broadband and FTTx to provide their services and customer satisfaction is an essential objective. Reliability represents an essential requirement for the customer. Time and performance are components of reliability. There are a lot of parameters that are taken into consideration to achieve performance and consequently customer satisfaction. To guarantee Operation and Service Level Agreement (OLA and SLA) among the different entities in the Service Provider Organization and between the customer and service provider, the service provider should state the parameters that have an impact on achieving reliability of the system. This research paper conducted a risk assessment using the Preliminary Risk Assessment to state and prioritize the parameters that have an impact on achieving the high reliability of the system. The results from this research indicate that the percentage of the risks are 26.7 % in the power subsystem, 23.3% in the backbone subsystem, 16.7 % in the access subsystem, 10 % in the optical distribution network, 10 % in the application server, 3.3 % in the lack of materials, 3.3 % in the security safety subsystem, and 3.3 % in the security attacking subsystem. After assessing the risks in the service provider system, it discusses the required controls to mitigate or eliminate these risks.
Content may be subject to copyright.
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 21
Addressing Service Availability parameters in
Service Providers using Technology as a
Complex System
Tarek Heggi1, Maryam Hazman2, Fathy Amer3, Reem S. Abdallah4
1,2Central Lab. for Agricultural Expert Systems, Agricultural Research Center, Egypt
3Faculty of Computers and Information, Cairo University, Egypt
4Faculty of Engineering, Cairo University, Egypt
ABSTRACT
Service providers relay on different technologies such as Broadband and FTTx to provide their services
and customer satisfaction is an essential objective. Reliability represents an essential requirement for the
customer. Time and performance are components of reliability. There are a lot of parameters that are taken into
consideration to achieve performance and consequently customer satisfaction. To guarantee Operation and
Service Level Agreement (OLA and SLA) among the different entities in the Service Provider Organization and
between the customer and service provider, the service provider should state the parameters that have an impact
on achieving reliability of the system. This research paper conducted a risk assessment using the Preliminary
Risk Assessment to state and prioritize the parameters that have an impact on achieving the high reliability of
the system. The results from this research indicate that the percentage of the risks are 26.7 % in the power
subsystem, 23.3% in the backbone subsystem, 16.7 % in the access subsystem, 10 % in the optical distribution
network, 10 % in the application server, 3.3 % in the lack of materials, 3.3 % in the security safety subsystem,
and 3.3 % in the security attacking subsystem. After assessing the risks in the service provider system, it
discusses the required controls to mitigate or eliminate these risks.
Index Terms: Service Level Agreement, Risk Assessment, Preliminary Risk Assessment.
I. INTRODUCTION
The emerging of new applications that require high bandwidth has led the trend for using new network
architectures such as FTTx system. FTTx System uses either P2P or GPON architecture depending on the target users.
Cost Analysis mode that is proposed by [1] compare between GPON and P2P which illustrates that the P2P cost is on
average 15% greater than GPON and this percent is varying based on two parameters which are: take-up rate and
geographical area [2]. Some other case studies like [3] stated that the difference in Capital cost between GPON and
Active Ethernet (AE) is 5 % whereas, the Operation cost in GPON is lower than AE by 5 to 58% based on to the take-
rates. There are a lot of comparative analyses for evaluating these two architectures but it is beyond the scope of this
research. This research will address and prioritize the organization parameters that are concerned with the achieving of
service availability.
The essential metrics for evaluating the network performance include: availability, delivery, latency, and bandwidth [4].
Availability represent the continuity of the service. Reliability means performance over time, or in a formal definition
per [5] “the probability of components, parts, and systems to perform their required functions for a desired period,
without failure, in specified environments with desired confidence”. Another important definition for reliability is
“Quality over time” [6]. Thus, reliability includes the availability and functionality of the system. The functional of the
system is represented in network performance and operation.
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 22
II. METHODOLOGY
This work has been adapted the following steps to conduct the risk assessment to running systems:
1- Selecting the suitable technique to be applied
2- Define system in terms of its components and functions
3- Identify hazards of the system
4- Identify parameters of risks evaluation and decisions
5- Analyzing and mapping risk scenarios
6- Identify controls
III. SELECTION CRITERIA FOR RISK ASSESSMENT TECHNIQUE
There are too many approaches to implement the risk assessment, this study used the preliminary risk assessment (PRA)
[7] analysis due to the following reasons:
Suitable to be applied on operation phase [8-9]
It provides both qualitative and semi quantitative analyses [10]
It is a systemic approach which supports complex systems which composed of several actors and
relationships that can include elements other than work processes such as environment, and staff [11-13].
Usability, its implementation process is well documented.
Popularity, it has been used in many applications
IV. RISK MANAGEMENT OVERVIEW
Figure 1 indicates the methodology that will be applied which follow the systemic approach as in [13, 14].
Risk
Categorizing
Risk Analysis
Risk Evaluation
Risk Assessment
Controls
Monitor
Assets
Work Processes
Staff
Service Provider System
Hazard
Figure 1. Application of PRA for Risk Management
V. OVERALL SYSTEM RELIABILITY
The reliability of the system reliability is measured using the quality of its provided services and the up time
of the services. There are three terms that are used to calculate the total service downtime and the system availability
percent which are: repair, means the fault caused the node failure and it should be repaired, one of the method of
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 23
repairing is the replacement [15], recovery is a stage after repair which mean to system complete its procedures to be
started/loaded then restore after the completion of recovery, the system is considered restored [15].
Availability have different perspective from different vendors, [16] indicates three significant components: device,
network, and operational. On the level of device component, it is affected by parameters such as redundancy, hot
swapping, modularity, and in service software upgrade [16]. On the level of network, it is affected by parameters such
as access control, redundancy in its devices, and Quality of service [16]. on the level of operations, it is affected by
parameters such as: open standards, and automate operational tasks [16].
Availability is represented by the percentage of the uptime that the system is running, to achieve the high availability
means that this percentage should be either 99.999 % or 99.9999 % which are equivalent to the downtime shouldn’t
exceed 5 minutes, and 30 seconds respectively in a year [17]. During our calculating the availability, basic differences
are needed to be explained before going into implementation as they will assist us in selecting the appropriate controls
that can increase the system availability.
There are multiple methods to calculate the availability [18] [19] [20], one of them is the probability of the system is
down if both Node 1 and Node 2 are down. The system availability is assumed to be “A”, and the probability of failure
is “F”.
We will consider three scenarios, Figure 2 and Figure 3 indicate the active/active system in which the availability is
calculated as follows:
Active Node #1
Active Node #2
Figure 2. Two Active/Active Nodes System
Active Node #1
Passive Node #2
Figure 3. Two Active/Passive Nodes System
For Active/Active and Active/Passive System, assuming that the availability of each node is “a”, and the probability of
failure on Node 1 = F
F = 1 -a, for node 1 and node 2
A = 1 (1-a) (1-a)
= 1 (1-a)2 = 1 (1 -2a + a2)
= 1 -1 + 2a - a2
= a (2-a) equation (1)
The difference between Active/Active and Active/Passive systems include the switch over time in Active/Passive, the
complexity of system in Active/Active system and the fully loaded time in the Active/Active system.
For Serial Components in Figure 4 represent a system that consists serial nodes or components.
Node #1 Node #2
Figure 4. Serial Nodes System
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 24
Assuming that Node 1 has availability “a1” and Node 2 has availability “a2” then
A = a1.a2
For calculating Availability in individual components [ 20] [21] [22] [23] [24], mean time between failure (MTBF) for
reliability and mean time to repair (MTTR). From MTBF and MTTR are known, the availability of the component
can be calculated using the following formula:
[25]
Evaluation of the system reliability relies on the contribution of its components and the design of these components,
parallel components provide higher reliability than serial components, which means that changes in the design can have
a great significant improvement in the reliability [26]. availability can be calculated using the following formula A =
u/ (u + d) where u is the uptime, d is the downtime [26].
There are many reliability models that can be used for the system such as Petr Net, Markov, and Monte Carlo
simulation [27].
VI. PRELIMINARY RISK ASSESSMENT (PRA) MODEL
The risk of an event can be defined as an abstract concept that consider past, present, and future [28].
According to this definition, the parameters that are considered to calculate the risk of the event are defined. These
parameters are the probability of occurrence of the event and its severity [28]. The decision for classifying the risk and
putting them into categories depends on the value of the product of the two valued for the probability and the severity
[28]. During the defining system in terms of its components and its processes. An example for categories of risk as
indicated in Table 1. Figure 5 explains how the risk is created from the interaction between the components of the
system and the hazards though a root cause or initiator [30].
System
Hazards
Risk
Root Cause
Figure 5. Risk Structure
VII. IMPLEMENTATION
This research will identify the parameters that have impact of reliability in the network system which is responsible
for providing services form the service provider to the customers. The FTTH system is considered as a complex system
because this system constitutes from different functional blocks that act different activities and all blocks should be
operated to be able to provide the services to customers. This research will apply risk management approach to identify
these parameters that impact the provisioning of QoS and guarantee the SLA. Risk is identified as the combination of
the probability of occurrence of a hazard generating harm in each scenario and the severity of that harm, Hazard is a
potential source of harm, the likelihood is the probability of occurrence of that harm [30]. Also, Risk can be identified
as effect of uncertainty on objectives” [31]. The third definition of risk is “the net negative impact of the exercise of a
Severity
Probability
1
2
3
4
5
5
1
2
3
3
3
4
1
2
2
3
3
3
1
1
2
3
3
2
1
1
2
2
3
1
1
1
1
2
2
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 25
vulnerability, considering both the probability and the impact of occurrence” [32]. To determine the risk identification
for a system, there are is no standard risk classification that can be implemented to any type of organization as
mentioned by ISO 31000 for Enterprise Risk Management.
VIII. SERVICE PROVIDER CONFIGURATION SCENARIO
In FTTH scenario, this system that consist of two functional blocks, Access and Core and they represent the main block
that must be exist to provide the service to the residents. Figure 6 illustrates the system block diagram.
FTTx System
Service
Customer
Access Elements
ONT OLT
System
Core Elements
ApplicationsNetwork
Service
Figure 6. FTTH System Block Diagram
This system consists of elements for access, core, and applications. Access elements include ONT, OLT, and PON.
Figure 7 indicated the elements of the access network. OLT represents the element that aggregates all termination that
comes from splitters. ONT represents that equipment that is installed in customer side and connects the customer
devices such as IPTV STB, access points, phones, and computers. Passive Optical Network (PON) represents the fiber
cabling system between data center and customer units.
OLT
ONT
Fiber Optics Splitter
(Fiber Concentration Point)
Access Node
Feeder Cabling
Drop Cabling
Internal Cabling
Customer Unit
Data Center Passive Optical Network (PON)
Figure 7. Structure of Access Network
The Access system is considered as a complex system because it consists of multiple subsystems and interventions
from different actors. Operation deficiency in any component of the system has an impact on the overall performance
and availability of the service. The elements definition per [33], Access Node represents the OLT, Feeder Cabling
represents fiber cables from OLT to fiber optics splitter. Fiber optics splitter is the fiber concentration point (FCP). The
internal cabling system represented the indoor fiber cable. To maintain the proper operation from dB power perspective,
during operation a verification process to ensure the received power meets the vendor thresholds to ONT element, i.e.,
received power to ONT doesn’t be less than -28 dB or more than -28 dB. As per [33], the following equation can be
used for this verification Loss = Lcable + Lsplice + Lconnector, this verification is use during design phase and in operation
phase, the troubleshooting will include these parameters. Also, it worth to mention that FTTH network lifetime could
be 30 years or more [33].
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 26
IX. TECHNIQUES TO IDENTIFY UNCERTAINTIES
This study will rely on historical data for previous periods that will be collected through email messages,
meetings with different levels of staff, cases with support companies, and customer feedback reports.
Hazard categories can be classified into the following groups as shown in table 2 the below categorization is
based on actual status in addition to the assistance of terms and categories in [16]:
Table 2. Preliminary Risk Assessment for FTTH Service Provider Hazard Mapping
17
65
3
General
Hazards
Specific Hazards
Source of Hazard
Power Outage
UPS
Battery
Rectifier
Inverter
Static bypass switch
Generator
Fuel
Battery
Sensors
Filters
Oil
ATS Panel
Battery
Contactors/Circuit Breakers
connections
Power Distribution Panel
Contactors/Circuit Breakers
connections
location
Main Power Source
Egyptian Electricity Holding company (EEHC)
Contactors/Circuit Breakers/Fuse
connections
Air
Conditioner
Failure
Air Conditioner
cooling efficiency
Partially
failure in
Optical
Distribution
Network
(ODN)
splitter
Fiber Feeder Cable
Outdoor Fiber Drop Cable
Fiber Patch Cord
Backbone
System Failure
Hardware
Power supply
FAN
backplane
switching fabric
Line Card
Physical Fiber Ports
Software
IOS/Firmware
unsupported Version
upgrading
Configuration
Applying new features
Modifying existing features
Human Error
uncontrolled changes or mistakes during configuration
Access System
Failure
Hardware
Rectifier
FAN
backplane
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 27
switching fabric
Line Card
Physical Fiber Ports
Software
Firmware
unsupported Version
upgrading
Configuration
Applying new or modifying existing features
Human Error
uncontrolled changes or inadvertently mistakes during configuration
Application
Server Failure
Hardware
Power Supply
HDD
Board/CPU
Operating System
Network Security
Human Error
uncontrolled changes or inadvertent mistakes during configuration
Lack of
Material and
Tools
Dysfunction
Shortage of office supplies (paper, files, envelops)
Disturbance of cars distribution movement
Failure of computers
Testing Tools
Failure of office machines (photocopier, plotter, printer, Fax)
Safety System
Failure
Dysfunction of Safety
system
Fire Fighting
Fire Alarm
Attacking
System
Security
Dysfunction of Physical
Security
Surveillance
Access Control
Intrusion Detection
Dysfunction of Network
Security
Antivirus
Firewall
Documentation
Procedures
Technical Documentation
External Maintenance Procedures
Customer
Out of scope requirements
Irrelevant time
Staff
Number of Staff is not sufficient for specific Tasks
No defined Career path
Supportive
entities
Purchasing
Delay in completing procedures
External Maintenance
Checklist for maintenance procedures is not sufficient
The company is not committed to response time
The severity impact, the probability, and category of risks are configured as show in Table 3, Table 4, and Table 5.
Table 3: Severity of System Risks
Level
Index
Consequences
Insignificant
10
No impact on system performance
11
Its influence is service interruption on limited number of customers due to reasons related
to customer
12
Delay in troubleshooting due to customer issues such as irrelevant time
Low
20
Inferior performance
21
the impact is on one customer due to the normal operation such as upgrade process of
his/her device
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 28
Delay in troubleshooting due to internal issues such as the testing tools are not exist or not
working
Major
30
Serious alarm of the performance
31
its impact is on a group of customers due to distribution cable cut or failure in Physical
Fiber interface for one time per 6 months for less than 12 hours
32
Intermittent Service Failure due to over utilization in core/access/server equipment or
cooling efficiency
Critical
40
Service Down
41
Power/Cooling Failure for more than one time per 3 months for more than 12 hours
42
Network (Core/Access/Server) Failure for more than one time per 3 months for more than
12 hours
Table 4: Probability of Risks
V1
Rarely occurred
1
Less than one time per T1
T1
1 year
V2
Possible
2
Less than one time per T2
T2
6 Months
V3
Major
3
Less than one time per T3
T3
3 Months
V4
Critical
4
Greater than one time per
T3
P4
High
4
Table 5: Risk Categories
Risk
Category
Description
Index
Type of decision or action
C1
Acceptable
1
No action is required to be taken
C2
Tolerable
2
Risk is within accepted limits but need monitoring
C3
Inadmissible
3
Risk is need control measures
C4
Inacceptable
4
Risk refused
X. RESULTS
The analysis of the APR indicates the risk categories which are indicated in table 6. The hazard situation and
their possible risks which generate from the possibility of interaction among the system elements and the hazard.
Table 6. Risk Categories
General Hazard
Abbreviation
Hazard Situation (HS)
Risk Scenario (RS)
Power Outage
PWO
5
8
Air Conditioner Failure
ACF
1
1
Partially failure in Optical Distribution
Network (ODN)
ODNF
1
3
Backbone System Failure
BSF
2
7
Access System Failure
ASF
3
5
Application Server Failure
APSF
3
3
Lack of Material and Tools
LMT
1
1
Safety System Failure
SSF
1
1
Attacking System Security
ATT
0
1
Documentation
DOC
0
0
Customer
CUS
0
0
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 29
Staff
STF
0
0
Supportive entities
SUPP
0
0
The results in table 6 are represented in Figure 8, which indicated that the risks with higher probability in order are:
power outage (PWO), Backbone System Failure (BSF), Access System Failure (ASF), Partially failure in Optical
Distribution Network (ODNF), and Application Server Failure (APSF), Air Conditioner Failure (ACF), and Lack of
Material and Tools (LMT), and Safety System Failure (SSF), and Attacking System Security (ASS).
Figure 8. Risk Analysis for Service Provider System
Figure 9 indicated percent of the source of hazards as follows: 26.7 % in the power subsystem, 23.3% in the backbone
subsystem, 16.7 % in the access subsystem, 10 % in the optical distribution network, 10 % in the application server,
3.3 % in the lack of materials, 3.3 % in the security safety subsystem, and 3.3 % in all the security attacking subsystem,
Figure 9. Percentage of System Risks by Source of Hazards
XI. DISCUSSION FOR CONTROLS
Power outage was the highest source of risks, the main parts of UPS element in power system are: Inverter,
rectifier battery, and static bypass switch. studies [35] stated that inverter is the most important part that impact on
reliability. therefore, we proposed the following controls to reduce the severity of this source by putting batteries into
parallel groups instead of one group and each group should maintain the UPS running for 10 minutes on actual load,
recording the manufacturing date of the battery, the installation date, and periodically verify the efficiency of the
battery quality through the checklist that is executed by the maintenance company. These controls will increase the
availability from 99.9 % (This value is for a well-known brand name) for a single UPS system and it translated to 9
hours of outage per year. Per equation (1), the implementation of this control will cause the availability to be:
A = a (2-a) = 0.999(2-0.999) = 99.9999 % which reduces the outage time to 3 secs.
Backbone system was the second source of risks, if for one major element in the backbone system, its component is
indicated in the Figure 10. This element is assumed to be 99.974 %. The proposed controls were Ensuring the proper
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 30
configuration for the two power supplies, monitoring fan status either through NMS or manually, ensuring reliability of
the current backplane as it considered as a passive element, the response time in the support contract, evaluate other
network designs.
Regarding the access system failure. It was the third of risks, if the OLT element has an availability of 99.943 %. The
following are the controls: following up a configuration change procedures, having a test lab to verify the results of any
changes, having a testing checklist to verify any new changes, continues monitoring for utilization on Cards, having
redundant line card, having fiber spare cables, the number of additional cables needs more investigation, the generated
error is listed in the release note of the new version or approved by the vendor, periodical checking for the new
firmware versions and the list of fixed bugs, replicating the error cases, following up the procedures of escalating with
the vendor, and Verification procedures for any changes in configuration.
Backplane
Power Supply1
Fan1
Power Supply 2
Fan n
Fan2
Control Plane Card (Supervisor/Management)1
Control Plane Card (Supervisor/Management)2
Data Plane Card (Line Card)1
Data Plane Card (Supervisor/Management)n
Fan Tray
Figure 10. Backbone Element
Partially failure in Optical Distribution Network (ODNF), it has a 10 % of risks. The controls that are proposed are:
availing as possible protection for the paths of fiber cables, having sufficient spare parts, and having trained staff or
maintenance contract, ensuring the proper installation in protected path for outdoor cables, and implementing type B
protection for business customers.
Calculating The availability of the entire system needs to have the availability of each subsystem the get the product of
the all these subsystems to get the overall as follows:
T =

 ,
T = A1 x A2 x A3 x A4 x A5 x A6
Where,
n equals the number of the subsystem
A1 = Availability of the power subsystem
A2 = Availability of the backbone subsystem
A3 = Availability of the access subsystem
A4 = Availability of the optical distribution network subsystem
A5 = Availability of the processes
A6 = Availability of human factor
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 2, February-2017
Page | 31
CONCLUSION
Not only assets that have an impact on the availability of complex system but other elements as the lack of
materials, the security safety subsystem, and the security attacking subsystem have a considered a total of 9.9 % of
risks in addition to the human error. if we consider that power outage represents 100% this value of these three sources
will be 37.1 % without adding the human factor. Supportive work processes are another source of hazards. This
research needs cost analysis for the required controls to compromise among the cost of these controls. Also, the
duration time of failure should be considered as a variable because the longtime of failure is considered as a high
severity source of hazards even it is caused for limited number of customer and it expose the service provider for a bad
image and have a bad impact on customer experience.
REFERENCES
[1]. Mason, Analyses. "The costs of deploying fibre-based next-generation broadband infrastructure." Final report for the
Broadband Stakeholder Group 8 (2008): 12726-371.
[2]. Jay, Stephan, Karl-Heinz Neumann, and Thomas Plückebaum. "The cost of nationwide fibre access in Germany."
Communications & Strategies 85 (2012): 169-188.
[3]. Kulkarni, Samrat, et al. "FTTH network economics: key parameters impacting technology decisions."
Telecommunications Network Strategy and Planning Symposium, 2008. Networks 2008. The 13th International. IEEE,
2008.
[4]. Lee, Hyo-Jin, et al. "QoS parameters to network performance metrics mapping for SLA monitoring." KNOM Rev 5.2
(2002).
[5]. Critchley, Terry. High Availability IT Services. CRC Press, 2014.
[6]. Tixier, Jerome, et al. "Review of 62 risk analysis methodologies of industrial plants." Journal of Loss Prevention in the
process industries 15.4 (2002): 291-303.
[7]. Desroches, Alain. "Notion de risque et approche de la maîtrise des risques.", 2011
[8]. de Andrades, Silvana Alves, André Nagalli, and Ronaldo Luis dos Santos Izzo. "Preliminary Risk Analysis in the
Operation of a Sanitary Landfill." Electron. J. Geotech. Eng 19 (2014): 3167-3177.
[9]. Perdaman Industries, GHD, http://www.perdaman.com.au/media/7503/section%206%20-
%20preliminary%20risk%20assessment.pdf” visited on 21 February 2017.
[10]. Tixier, Jerome, et al. "Review of 62 risk analysis methodologies of industrial plants." Journal of Loss Prevention in the
process industries 15.4 (2002): 291-303.
[11]. SILVA, Meuris Gurgel Carlos da, and Samira Maria Leão de CARVALHO. "Preliminary risk analysis applied to the
handling of health-care waste." (2002).
[12]. Chorowski, M., Ph Lebrun, and G. Riddone. "Preliminary risk analysis of the LHC cryogenic system." Advances in
cryogenic engineering. Springer US, 2000. 1309-1316.
[13]. Network Infrastructure Committee. "FTTH Infrastructure Components and Deployment Methods, 2007."
[14]. Dumbravă, Vasile, and Vlăduț-Severian Iacob. "Using ProbabilityImpact Matrix in Analysis and Risk Assessment
Projects." Descrierea CIP/Description of CIP–Biblioteca Națională a României Conferința Internațională Educație și
Creativitate pentru o Societate Bazată pe Cunoaștere–ŞTIINŢE ECONOMICE (2013): 42.
[15]. The Availability Digest, Calculating Availability The Three
Rs,www.availabilitydigest.com/private/0103/calculating_availability_three_rs.pdf”, Visited on 14, January 2017
[16]. Dell Inc., “Datacenter Class Reliability for High-Performance Business, DELL PowerConnect J-Series Ethernet
Switching Solutions: Building a Highly-Available Enterprise Network “A Dell Technical White Paper, 2010. Visited on
14 January 2017.
[17]. Cisco Systems, Inc., Delivering High Availability in the Wiring Closet with Cisco Catalyst Switches, White Paper, Dec
11, 2013. Visited on 14 January 2017.
[18]. The Availability Digest, Calculating Availability Heterogeneous Systems Part 1, March 2008"
http://www.availabilitydigest.com/public_articles/0303/calculating_availability_heterogeneous_syst.pdf”, Visited on 14
January 2017.
[19]. The Availability Digest, Calculating Availability Redundant Systems, October 2006,
http://www.availabilitydigest.com/public_articles/0101/calculating_availability.pdf, Visited on 14 January 2017.
[20]. System Reliability and Availability,
http://www.eventhelix.com/RealtimeMantra/FaultHandling/system_reliability_availability.htm, Visited on 14
January 2017.
[21]. Zeng, Jihong. "A case study on applying ITIL availability management best practice." Contemporary Management
Research 4.4 (2008).
[22]. Nickel, S.J, The Investment Decisions of Firms. Cambridge: University Press, 1978. Office of Government Commerce
(2000). IT Infrastructure Library. The Stationary Office: London.
[23]. Zacks, S., Introduction to Reliability Analysis: Probability Models and Statistics Methods. New York: Springer-Verlag,
1992.
[24]. The Availability Digest, High Availability Network Fundamentals, April 2009,
http://www.availabilitydigest.com/public_articles/0404/ha_networks.pdf, Visited on 14 January 2017.
[25]. E. E. Lewis, Introduction to Reliability Engineering, J. W. Sons, Ed. New York: Wiley, 1987.
[26]. Soleimani, Morteza, and Mohammad Pourgol-Mohammad. "Design for reliability of complex system with limited
failure data; case study of a horizontal drilling equipment." Proceedings of the Probabilistic Safety Assessment and
Management PSAM 12 (2014).
International Journal of Enhanced Research in Science, Technology & Engineering
ISSN: 2319-7463, Vol. 6 Issue 1, January-2017
Page | 32
[27]. High Availability Network Operations,
www.cisco.com/networkers/nw01/pres/pr/ps_presos/PS_544_1HANTULA_C3.pdf, Visited on 14 January 2017.
[28]. Desroches, Alain, and Sébastien Delmotte. "Macro-Cartographie des Risques par Audit: une méthode de diagnostic
et de management global des risques d'entreprise." QUALITA'2015. 2015.
[29]. Desroches, Alain. "Notion de risque et approche de la maîtrise des risques." 6 et 7 avril 2011.
[30]. EU general risk assessment methodology (Action 5 of Multi-Annual Action Plan for the surveillance of products in the
EU, http://ec.europa.eu/DocsRoom/documents/15261/attachments/1/translations/en/renditions/native.”, 16 October 2015.
[31]. AIRMIC, Alarm, and A. IRM. "structured approach to Enterprise Risk Management (ERM) and the requirements of ISO
31000." The Public Risk Management Association, London, UK (2010).
[32]. SP800, N. I. S. T. "Risk Management Guide for Information Technology Systems.", 2002.
[33]. Network Infrastructure Committee. "FTTH Infrastructure Components and Deployment Methods, 2007.".
[34]. Cale, Ivica, Aida Salihovic, and Matija Ivekovic. "Gigabit passive optical network-GPON." 2007 29th International
Conference on Information Technology Interfaces. IEEE, 2007.
[35]. ABB, Reliability of uninterruptible power supplies,
“https://library.e.abb.com/public/091b6999a8964a64b11331852879ca25/White_Paper_Relibility_150506.pdf”
Visited on 15 January 2017.
ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
Reliability is an important phase in durable system designs, specifically in the early phase of the product development. In this paper, a new methodology is proposed for complex systems’ design for reliability. Specific test and field failure data scarcity is evaluated here as a challenge to implement design for reliability of a new product. In the developed approach, modeling and simulation of the system are accomplished by using reliability block diagram (RBD) method. The generic data are corrected to account for the design and environment effects on the application. The integral methodology evaluates reliability of the system and assesses the importance of each component. In addition, the availability of the system was evaluated using Monte Carlo simulation. Available design alternatives with different components are analyzed for reliability optimization. Evaluating reliability of complex systems in competitive design attempts is one of the applications of this method. The advantage of this method is that it is applicable in early design phase where there is only limited failure data available. As a case study, horizontal drilling equipment is used for assessment of the proposed method. Benchmarking of the results with a system with more available failure and maintenance data verifies the effectiveness and performance quality of presented method.
Article
Full-text available
The Large Hadron Collider (LHC), presently under construction at CERN, will require a helium cryogenic system unprecedented in size and capacity, with more than 1600 superconducting magnets operating in superfluid helium and a total inventory of almost 100 tonnes of helium. The objective of the Preliminary Risk Analysis (PRA) is to identify all risks to personnel, equipment or environment resulting from failures that may accidentally occur within the cryogenic system of LHC in any phase of the machine operation, and that could not be eliminated by design. Assigning a gravity coefficient and one analyzing physical processes that will follow any of the recognised failure modes allows to single out worst case scenarios. Recommendations concerning lines of preventive and corrective defence, as well as for further detailed studies, are formulated.
Article
Full-text available
It is common knowledge that Next Generation Access (NGA) networks require significant investments and that for many regions, especially in more rural areas, there is no viable business case. In this paper a bottom-up cost modelling approach is applied to determine the investment and cost of deploying and operating a FTTH network in Germany on a national level. The monthly cost per subscriber at various levels of penetration is compared with the Average Revenue Per User (ARPU) to determine the penetration level or the required revenue for profitable operation in a steady market state. Those regions for which there is no business case are analysed with regard to the level of required subsidies. The modelling is based on differentiated geotypes reflecting urban and rural areas. The basic cost model used has been applied to numerous case studies before and was adapted to determine different forms of subsidies.The research questions addressed are (1) What is the area of profitable FTTH coverage in Germany? (2) What is the level of prices, internal subsidisation or investment subsidy necessary to increase the coverage of FTTH in Germany? These results inform policy makers and operators of the relevant investment deltas and/or price levels needed to increase the coverage of next generation broadband access infrastructure.
Article
Full-text available
Service Level Agreement (SLA) is a formal negotiated agreement between a service provider and a customer. The service level management (SLM) is the integrated management of all functionalities in the SLA life cycle. When a customer orders a service from a service provider, an SLA is negotiated and then a contract is made. In the SLA contract, QoS parameters that specify the quality level of service that the service provider will guarantee are included. The service provider must perform SLA monitoring to verify whether the offered service is meeting the QoS parameters specified in the SLA. SLA monitoring involves monitoring the performance status of the offered service and provide relevant information to the service level management system. In order for the service level management system to verify whether the specified QoS parameters are being met, the system must gather performance data from the underlying network performance monitoring system and map such data to the QoS parameters. In this paper, we propose a formal mapping mechanism between QoS parameters in SLA and the network performance metrics. Although we focus on the network access service (e.g., leased-line service, xDSL service, VPN service) in this paper, we believe that our mapping mechanism can be easily used in SLA monitoring of other services (such as application, server hosting, contents). We also propose a general SLA monitoring system architecture that can be used to monitor service levels for various services offered by network, Internet and application service providers. We then present how our SLA monitoring system architecture can be used for SLA monitoring of IP backbone network service.
Article
Currently, the risk level has been increasing globally, and increasingly requires organizations to develop the ability to deal with high risk level in their strategic plans, projects, and processes, both in the public and the private sectors. The use of efficient processes for managing and analyzing risks that allow for the treatment and prevention of crises is essential, thus, risk analysis aims at protecting the company's human, material, and financial resources. The purpose of this work is to detect the risks in which the sanitary landfill workers are exposed to, creating preliminary risk analyses (PRAs), and generating recommendations on how to solve or minimize such risks. Results have shown that among the activities analyzed, the main risks found through the PRA's developed were: running over, burial, noise, inappropriate lighting, electric shock. The main action suggestions concern general and easy-to-implement solutions, such as periodic employee training and awareness. The latter is recommended to be applied on a daily basis, as DDS (Daily Safety Reports). Besides, the appropriate use of PPE's is extremely important.
Article
This paper presents a case study on how to apply ITIL availability management best practice to assess the end-to-end service availability in a tiered web service delivery environment. It also helps pinpoint the road blocks to the required service level and provide cost-effective solution for improved service delivery. An overview of basic ITIL availability management concept is provided along with the introduction to two key parameters, mean time between failure (MTBF) for reliability and mean time to repair (MTTR) for maintainability. Then a block diagram modeling approach for the overall information system availability assessment is presented. The block diagrams are used to describe the interrelationship among the components or subsystems to define a system model. The ITIL best practice approaches for availability management are discussed in detail in the case study. It demonstrates that the overall service availability is affected by the availability of information systems as well as applications and operational processes. The modeling approach is capable of gaining visibility on root cause of the service availability degradation, identifying risks in the existing information system, and providing support to future application development and infrastructure upgrade for high availability business services.