ArticlePDF Available

Exploring the Role of Wearable Technology in Sport Kinematics and Kinetics: A Systematic Review

MDPI
Sensors
Authors:

Abstract and Figures

The aim of this review was to understand the use of wearable technology in sport in order to enhance performance and prevent injury. Understanding sports biomechanics is important for injury prevention and performance enhancement and is traditionally assessed using optical motion capture. However, such approaches are limited by capture volume restricting assessment to a laboratory environment, a factor that can be overcome by wearable technology. A systematic search was carried out across seven databases where wearable technology was employed to assess kinetic and kinematic variables in sport. Articles were excluded if they focused on sensor design and did not measure kinetic or kinematic variables or apply the technology on targeted participants. A total of 33 articles were included for full-text analysis where participants took part in a sport and performed dynamic movements relating to performance monitored by wearable technologies. Inertial measurement units, flex sensors and magnetic field and angular rate sensors were among the devices used in over 15 sports to quantify motion. Wearable technology usage is still in an exploratory phase, but there is potential for this technology to positively influence coaching practice and athletes’ technique.
Content may be subject to copyright.
Sensors 2019, 19, 1597; doi:10.3390/s19071597 www.mdpi.com/journal/sensors
Review
Exploring the Role of Wearable Technology in Sport
Kinematics and Kinetics: A Systematic Review
Yewande Adesida *, Enrica Papi and Alison H McGregor
Department of Surgery and Cancer, Imperial College London, Charing Cross Campus, London, W6 8RP, UK;
e.papi@imperial.ac.uk (E.P.); a.mcgregor@imperial.ac.uk (A.H.M.)
* Correspondence: yewande.adesida12@imperial.ac.uk
Received: 7 February 2019; Accepted: 26 March 2019; Published: 2 April 2019
Abstract: The aim of this review was to understand the use of wearable technology in sport in order
to enhance performance and prevent injury. Understanding sports biomechanics is important for
injury prevention and performance enhancement and is traditionally assessed using optical motion
capture. However, such approaches are limited by capture volume restricting assessment to a
laboratory environment, a factor that can be overcome by wearable technology. A systematic search
was carried out across seven databases where wearable technology was employed to assess kinetic
and kinematic variables in sport. Articles were excluded if they focused on sensor design and did
not measure kinetic or kinematic variables or apply the technology on targeted participants. A total
of 33 articles were included for full-text analysis where participants took part in a sport and
performed dynamic movements relating to performance monitored by wearable technologies.
Inertial measurement units, flex sensors and magnetic field and angular rate sensors were among
the devices used in over 15 sports to quantify motion. Wearable technology usage is still in an
exploratory phase, but there is potential for this technology to positively influence coaching practice
and athletes’ technique.
Keywords: wearables; sports performance; kinematics; sensors; motion analysis; athlete; coaching
1. Introduction
1.1. Background
The role of feedback in sport is of great importance, and both coaches and athletes can benefit
from it as a means of improving athletic performance or minimizing injury risk. The coaching process
can be highly subjective, as Jones and Wallace (2005) state: ‘Every coach or athlete brings personal
interests to the coaching setting’ [1]. Ambiguity can arise in how best to develop and optimize an
athlete’s performance, with the technique and approach used by the coach being reliant on their own
expertise, experience and background. Rising interest and research into technology is helping to
overcome this subjectivity; for example, video analysis where videos can be annotated to measure
angles, allowing performance to be quantified objectively rather than be dependent on the coach’s
critical eye. However, whilst such approaches provide objectivity there is a desire to provide athletes
with real-time feedback.
1.2. Types of Systems
Motion capture systems have the ability to analyse the biomechanics of many functional and
sporting tasks. Optical systems consist of cameras used to track passive or active markers placed on
anatomical landmarks in order to obtain full-body capture. A systematic review by Pueo et al. (2017)
stated Vicon (Oxford Metrics, Oxford, UK) and Qualisys (Qualisys AB, Göteborg, Sweden) as being
Sensors 2019, 19, 1597 2 of 28
the most commonly used systems in a number of different sports, from tennis to swimming to
taekwondo [2]. However, due to camera set-up, these systems are limited by their capture volume,
generally being confined to laboratory settings. Furthermore, the large number of markers frequently
required has implications on time and can impede the performance of the tasks under investigation
and, conversely, the complexity of sporting tasks frequently leads to marker occlusion.
Wearable technology, however, is an alternative approach that has the potential to overcome
these limitations. There is a range of different types of sensors, including inertial measurement units
(IMUs) and microelectromechanical sensors (MEMS), containing a combination of magnetometers,
accelerometers and gyroscopes. In addition, there are also flex sensors, such as those produced by
Spectra Symbol (Salt Lake City, UT, USA), capable of tracking joint motion through means of changes
in resistance when a force is applied to the sensor.
A significant advantage of these wearable systems is the ability to monitor athletes in a real sport
environment to provide real-time feedback, a feature not offered by video analysis. Furthermore,
they are designed to be small, lightweight, wireless and unobtrusive permitting full movements
while participating in a sport. This gives rise to the potential for athletes to be observed outside a
laboratory setting and in their natural training environment. Sensors have been used in sports such
as skiing, snowboarding and swimming that take place in extreme conditions and have the added
features of being waterproof or being able to withstand cold temperatures while recording data [3–
8]. However, they are not without limitations: the presence of ferromagnetic objects can distort
measurements from inertial-based systems [9], and precise positioning may affect data accuracy as
well as data integration introducing errors when trying to extrapolate positional data from
acceleration measures [10,11]. Furthermore, using a wireless method to transfer data has the potential
for loss of signal during recording time or interference from mobile phones or other devices that may
be on the same transmission frequency [12].
1.3. The Adoption of Wearable Technology in Sport
A number of sports are now being seen to use wearable sensors. Monitoring player workloads
in Australian football using Global Positioning System (GPS) devices has allowed energy expenditure
to be analysed, a process previously done using heart rate monitors [13]. Using heart rate alone is not
an accurate method of determining workload as it does not factor in speed and distance travelled
during a game [13]. GPS tracking devices placed on the upper back are used to quantify the difference
in the amount of work done in different player positions as well as the game intensities [13,14]. An
inverse relationship was proposed by Wisbey et al. (2007) between the success of a team and the
workload of the players from the use of these devices [14].
Wearable sensors have been used in American football to monitor concussions by measuring
linear and angular head accelerations upon impact [15]. Sensors have been integrated into helmet
linings and mouth guards, highlighting their unobtrusiveness, a key factor in their use in training
and competition. Siegmund et al. (2015) tested two such systems, which were found to detect over
95% of impacts, providing data that would have been otherwise unobtainable [15]. Injury prevention
has also been considered in baseball and volleyball where there is a problem with shoulder over-use
injuries. A study performed by Rawashdeh et al. (2016) was able to classify movements of the
shoulder joint, giving athletes and coaches quantifiable information [16].
By moving away from visual approaches, coaches are able to monitor several athletes in
volleyball at once and in real-time, using the VERT inertial measurement unit (IMU) system (Version
2.0, Mayfonk Inc., Fort Lauderdale, FL, USA) to quantify jump height accurately [17] without the
concern of markers being obstructed from the view of a camera. The VERT IMU is commercially
available, as are other systems such as the KINEXON sensor (Kinexon Sports and Media Gmbh,
Munich, Germany) used in sports such as basketball to measure player acceleration and the Nadi ×
yoga pants (Wearable X, New York City, NY, USA) which uses a combination of motion sensors and
haptic feedback to guide yoga technique.
1.4. Requirements for Wearable Technology in Sport
Sensors 2019, 19, 1597 3 of 28
Optical systems are widely considered to be a gold-standard method for motion capture [18], so
wearable technology should be validated against such systems and tested for reliability in order to
replace them. Recommendations have been suggested by Düking et al. (2018) including confirming
both inter-device and intra-device reliability, simulating the movements in the sport intended for the
sensor to be used in and selecting a study population that is reflective of the ultimate intended user
[19]. Concurrent criterion validity is an easy way of determining similarities or differences between
the data obtained through wearable technology and a gold-standard reference. Test-retest and intra-
subject reliability are important when assessing the sensor performance with relation to the
participants, while sensor sensitivity is essential when considering the change of parameters with
respect to time, as any sensors used need to be able to track these changes [19].
The sampling frequency of a wearable device is also important for tracking changes and is
dependent on the assessed movement and variables of interest, with recommendations based on the
Nyquist-Shannon sampling theorem [20]. This states that the critical sampling frequency must be a
minimum of two times the highest frequency in the signal of interest to obtain all the information
found in the original signal [21,22]. A consequence of having too low a sampling frequency is that
relevant information can be lost.
With sensors being wireless and having their own power source that is not connected to a mains
supply adds a recording lifetime to the system used. Any wearable technology needs to last at least
the duration of a training or testing session or the length of a race or match.
The increasing use of wearable sensors in sport cannot be ignored. The unobtrusive
measurement systems are able to provide athletes and coaches with information regarding the range
of motion, accelerations and impacts, among other indicators of performance or injury risk in real-
time. The provision of objective data takes coaching to a new level, allowing more informed decision-
making, yet the information collected from these sensors needs to be delivered in a format that is easy
to interpret for it to be of use.
Previous reviews have focused on inertial sensors only, such as those by Chambers et al. (2015)
and Camomilla et al. (2018) despite other technologies such as pressure insoles or flex sensors which
could find application in sport scenarios [23,24]. Their use is not as widespread as inertial sensors
and some may require further development, but have the ability to measure biomechanical variables
of use to athletes and support staff. Several reviews also exist targeting the validity, reliability and
use of activity monitors to quantify energy expenditure, measure heart rate and count steps [25–27].
However, these measures are not able to provide indications as to how the movement was performed,
thus limiting their ability to intervene to improve performance or prevent injury in a sporting
population.
The aim of this study was to identify the use of wearable technology in sports as a means of
measuring kinetic or kinematic variables that could be used to enhance performance or prevent
injury. The focus was on sport-specific movements being performed by people who participated in
these sports, while wearing a form of wearable technology. In addition to looking at the measures
obtained by the devices, the collection and processing of data was also considered, as well as the
lifetime of the devices and how some compared to gold standard measurements.
2. Materials and Methods
2.1. Search Strategy
The following databases were used to carry out a systematic search from inception up until 31st
October 2018: Scopus, Medline, Embase, Cochrane Library, IEEE Xplore, Web of Science (Core
Collection) and Engineering Village. The search terms were grouped under the following headings:
‘wearable’, ‘sensor’ and ‘sport’, with the Boolean search strategy used being ‘wearable AND sensor
AND sport’. The search strategy is detailed in Tables 1 and 2. Hand searches and screening the
references of relevant articles were also performed to identify studies that may have been overlooked
by the electronic searches. Retrieved articles were imported into Endnote X8 software (Clarivate
Analytics, Philadelphia, PA, USA).
Sensors 2019, 19, 1597 4 of 28
Table 1. Boolean search strategy.
General Specific
Wearable
Portable OR worn OR cloth*3 1 OR “body-mounted” OR “non-
invasive” OR mobile OR wearable* OR apparel OR textile OR
“electronic skin”
Cochrane
Library MeSH
terms
Wearable electronic devices (exp)
Embase MeSH
terms
Non-invasive monitoring
Clothing
Medline MeSH
terms
Clothing
Wearable electronic devices
Sensor
Sens*3 OR goniomet* OR acceleromet* OR monitor* OR inertia*
OR gyroscope* OR device* OR magnet* OR imu OR telemet* OR
pressure OR strain OR conductive OR stretch* OR flexible OR
smart OR electronic*1 OR electromagnetic OR microsensor*1 OR
microelectronic*1
Cochrane
Library MeSH
terms
Monitoring, ambulatory
Embase MeSH
terms
Ambulatory monitoring
Sensor
Devices
Monitoring
Medline MeSH
terms Monitoring, ambulatory
Sport Athlete*3 OR sport* OR (List of Olympic Sports, see Table 2)
Cochrane
Library MeSH
terms
Athletes
Sports
Exercise
Athletic performance
Motor activity
Embase MeSH
terms
Athletes
Sports
Exercise
Training
Sports medicine
Motor activity
Medline MeSH
terms
Athletic performance
Athletes
Sports
Exercise
Motor activity
Sports medicine
1 The asterisk (*) after the initial letters ‘cloth’ expands the search to include all terms beginning with cloth,
while the number ‘3’ limits the number of characters after ‘cloth’ of the included terms
Table 2. List of Olympic sports.
Olympic Sports
archery OR run*4 1 OR badminton OR basketball OR boxing OR canoe* OR cycl*4 OR bik*3 OR
bicycl* OR bmx OR div*3 OR equestrian OR dressage OR fencing OR football OR soccer OR golf
Sensors 2019, 19, 1597 5 of 28
OR gymnastics OR handball OR hockey OR judo OR pentathlon OR row*3 OR rugby OR sail*3
OR shoot*3 OR swim*4 OR taekwondo OR tennis OR trampoline OR triathlon OR volleyball OR
“water polo” OR weightlifting OR wrestling OR skiing OR biathlon OR bobsleigh OR curling OR
skat*3 OR luge OR “Nordic combined” OR skeleton OR snowboard*
1 The asterisk (*) after the initial letters ‘run’ expands the search to include all terms beginning with run, while
the number ‘4’ limits the number of characters after ‘run’ of the included terms
2.2. Eligibility Criteria
Articles were included if they were: published in English; included at least one of the following
outcome measures: kinematics, kinetics as obtained from wearable technology; participants took part
in a sport (defined as an organized physical activity done alone or with a group); dynamic movement
tasks were performed related to performance in the sport studied. Articles were excluded if they were
a review or case study; were a conference abstract (except peer-reviewed abstracts); used only non-
wearable devices; wearable technology was used to only quantify physical activity or spatio-temporal
parameters of the sport performed; or described a potential technology not validated/used with
human subjects.
2.3. Selection Process
Duplicates arising from searches in multiple databases were removed, and the titles and
abstracts were reviewed for inclusion by two independent reviewers (Y.A. and E.P.) against the
inclusion and exclusion criteria. Results from both reviewers were compared through discussion,
with any conflicts being resolved by a third reviewer (A.H.M). Full texts of the remaining articles
were retrieved, and these were evaluated against the inclusion criteria.
2.4. Data Extraction
The details used for data extraction were modified from a review published by Papi et al. (2017)
looking at the use of wearable technology to assess spinal kinematics [28]. The following details were
extracted from each study: aim; sport studied; sample size; participants’ demographics (e.g.,
population type, age, gender, mass, height); tasks conducted; measuring system used; data
acquisition/sampling; participant set-up (e.g., position of the sensors, fixation method); data
processing (e.g., filter used for the signal); kinematic and kinetic variables evaluated from the sensor
signals (performance indicators); statistical analysis technique; and reliability/evaluation.
2.5. Quality Appraisal
The review by Papi et al. (2017) was used as a basis for forming a quality assessment checklist
[28]. This was based on previous reviews on motion analysis and relating to the use of technology
[29,30]. 17 items were included in the checklist and each was rated between zero and two (0 = no, 1 =
limited and 2 = good detail), listed in Table 3.
Table 3. Criteria used for the quality assessment of included articles.
Quality Assessment Criteria
1. Were the research objectives or aims clearly stated?
2. Was the study design clearly described?
3. Was the study population adequately described?
4. Were the eligibility criteria specified?
5. Was the sampling methodology appropriately described?
6. Was the sample size used justified?
7. Did the method description enable accurate replication of the measurement
procedures?
8. Was the equipment design and set up clearly described?
9. Were sensors locations accurately and clearly described?
Sensors 2019, 19, 1597 6 of 28
10. Was sensor attachment method clearly described?
11. Was the signal/data handling described?
12. Were the main outcomes measured and the related calculations (if
applicable) clearly described?
13. Was the system compared to an acknowledged gold standard?
14. Were measures of reliability/accuracy of the equipment used reported?
15. Were the main findings of the study stated?
16. Were the statistical tests appropriate?
17. Were limitations of the study clearly described?
3. Results
A total of 44,220 articles were obtained from the search, five further articles were identified from
another review [23] and one from a search in Sensors. After duplicates were removed, 27,767 articles
remained for title and abstract screening using the eligibility criteria set out in Section 2.2. From there,
46 full texts were assessed for eligibility.
Thirty-four articles satisfied the inclusion criteria. The selection process and reasons for
exclusion are presented in Figure 1. The details extracted from these articles can be found in the
Supplementary Material, Table S1: Data extracted from included articles. Studies were conducted
across a range of sports: football and rugby (n = 4) [9,31–33], swimming (n = 3) [4,6,34], skiing (n = 6)
[5,7,8,35–37], equestrian (n = 3) [38–40], cricket (n = 1) [41], table tennis (n = 1) [42], badminton (n = 1)
[43], athletics and running (n = 4) [12,44–46], rowing (n = 1) [47], baseball (n = 3) [48–50], snowboarding
(n = 1) [3], golf (n = 1) [51], netball (n = 1) [52], archery (n = 1) [53], volleyball (n = 1) [54], canoeing (n
= 1) [55] and Nordic walking [56].
Figure 1. PRISMA chart detailing the article selection process [57].
Sensors 2019, 19, 1597 7 of 28
3.1. Article Quality
The quality of the included papers was rated according to the following scale: low (score ≤
33.3%), medium (33.4 – 66.7%) and high (score ≥ 66.8%) [28]. Four articles were deemed to be of low
quality [51,53,55,56], 19 of medium quality [4–8,12,31,32,37–39,41–44,47,49,50,54] and 11 of high
quality [3,9,33–36,40,45,46,48,52]. The results from this assessment are detailed in Appendix A, Table
A1. None of the articles described a sampling methodology and only one article out of the 34 that
were included attempted to justify the sample size [33]. Sample size was not reported in two articles
[41,51] and ranged from 1 [43] to 37 [48] in the remaining articles, with the average number of
participants at 10. Twelve studies had participants equal to or greater than this [4,5,7–
9,31,33,35,36,42,48,54]. Seventeen articles described the method in enough detail to enable it to be
replicated accurately [4,6,9,31–36,38–40,42,44,45,48,52]. All studies gave a description of where the
sensors were located, with 19 of them giving a description that was clear and accurate [4–
9,12,31,32,34–36,40,43,44,46–48,52].
Eleven of the papers compared the wearable systems to a gold-standard measurement during
their testing [3,9,33–36,45,47,49,50,52]. A further four papers compared observed parameter results
to values that had been reported in previous literature as means of sensor data validation [5,7,31,39].
3.2. Types of Measuring Systems Used and Evaluated Variables
Inertial sensors were the most common type of system used in these studies in the form of
individual sensor nodes or as part of a body suit. Individual inertial sensors were used in 13 articles
[6,12,32,34,38,39,45,47–49,52,54,55], body suits in five articles [3,6,8,9,40] and a combination in two
articles [5,7].
Body suits mentioned in the included articles were produced by different companies: suits by
Xsens Technologies B.V. (Enschede, The Netherlands) contained 16–17 sensor units, allowing full
body coverage [3,9,37,40]; while the Physilog inertial measurement units (IMUs) (GaitUp, Lausanne,
Switzerland) were incorporated into an underwear suit and contained five to seven sensors [5,7,8].
Blair et al. (2018) used the MVN Link IMS from Xsens Technologies B.V. (Enschede, The Netherlands)
to determine lower body kinetics and kinematics including sagittal plane angles for the shank and
pelvis during football and rugby kicks [9]; Gandy et al. (2018) also used an MVN suit to determine
hip and ankle joints, as well as their moments and forces [40]; while in snowboarding the suit was
used to determine knee and ankle joint angles [3]. The Physilog IMU suits (GaitUp, Lausanne,
Switzerland) were all used in skiing studies by Chardonnens et al. (2013a, 2013b, 2014) measuring
lower body joint angles and velocities, ski angles and centre of mass (CoM) position, force and
velocity [5,7,8].
In archery, athletics, swimming, table tennis, baseball, football and golf, tri-axial accelerometers
were used on their own to measure different kinematic and kinetic variables. Peak positive
acceleration of the tibia was evaluated in runners [44]; three-dimensional acceleration and angular
velocity during the golf swing using accelerometers weighing as little as 22g [51,58]; linear and
angular velocity and acceleration of the shank and thigh, as well as angular momentum, power and
impulse during the football instep kick [31]. The sensor module used in football by Meamarbashi et
al. had the largest dimensions of 23 cm × 2.3 cm × 2.5 cm and weighed 80 g, alongside a data logger
weighing 70 g and dimensions of 6 cm × 7 cm × 2.5 cm; the placement of both components was
controlled after each kick [31]. Koda et al. (2010) used the tri-axial accelerometers, weighing 93 g, to
evaluate kinematics of the arm in baseball [50]. Kiernan et al. (2018) used accelerations to determine
the peak vertical ground reaction force in male middle distance runners, with the accelerometer
contained within an activity monitor and fixed to the lateral right iliac crest with a neoprene belt by
the participants themselves [46]. In table tennis, the average peak plus acceleration value was
determined with a BSN node board small enough for use on most parts of the body (23 mm in
diameter) [42] and in swimming, accelerometers were used to determine roll and pitch angles (body
rotation) as well as body acceleration [4]. The devices used in swimming were reported as
unobtrusive and compared to every day accessories such as wristwatches and belts [4]. A tri-axial
accelerometer was used alongside a load cell by Mocera et al. (2018) in Nordic walking to characterize
Sensors 2019, 19, 1597 8 of 28
the different phases of the cyclic arm movement [56]. The authors stated that the system must have
the ‘lowest possible influence on the users’ movements in order to avoid undesirable compensations’,
in a sport where the walking poles weigh as little as 180 g [56]. An accelerometer was also used in
archery to measure arm displacement [53] but the type was not stated.
Magnetic, angular rate and gravity (MARG) sensors were used in football to study angle range
of motion [33] and in cricket to observe the elbow extension angle [41]. The x-IMU (x-io Technologies,
Bristol, UK) MARG sensors used in football weigh 49g with a battery and encased in a plastic housing
(57 mm × 38 mm × 21 mm) [59]. The Pedar Pressure Insole System (novel gmbh, Munich, Germany)
was used in two studies by Nakazato et al (2011, 2013) to measure the vertical ground reaction force
[36] and foot centre of pressure [35] in comparison to Kistler force plates (Kistler Instruments Ltd,
Hampshire, UK). The insoles have a thickness of 1.9mm and require an analyzer weighing 400 g [60].
T and T Medilogic (T and T Medilogic Medizintechnik GmbH, Schönefeld, Germany) bilateral insole
measurements were used in snowboarding to determine foot force alongside an inertial suit
measuring lower limb kinematics [3].
A flex sensor produced by Spectra Symbol (Salt Lake City, UT, USA) and incorporated into a
glove-like hand monitoring module was used by a badminton coach in order to determine the
different types of hand grips by measuring the flexion angle of the thumb, index and middle fingers
[43]. In this device, the flex sensors were connected to the battery and microcontroller, which were
also situated on the glove, by cables.
The specification for each technology and how each was fixed onto the study participants can
be found in the Supplementary Material (Table S1).
3.3. Testing Environment
Only five studies took place in a laboratory setting [9,33,34,44,47], most likely to allow the use of
a gold-standard measurement as a reference, which was the case in four articles [9,33,34,47]. Fantozzi
et al. (2016) had participants simulate the upper-body portion of the swimming stroke while the lower
limbs were held against a rigid box by an operator instead of performing experiments in the water
[34]. Reliable measurements were produced (RMSE = 5° and 7° for breaststroke and front-crawl,
respectively), but this method had its limitations as participants were required to use their lumbar
muscles to support themselves and range of motion of the body was reduced in comparison to normal
kinematics in the water [34]. Additionally, studies conducted by Wood et al. (2014) and King et al.
(2009) used treadmills and rowing machines but both authors mentioned the need to test the wearable
systems in a normal running environment and on the water [44,47].
Three articles did not state the environment that the experiments took place in [32,43,51] and the
remaining studies were conducted in field, with the skiing studies by Chardonnens et al. (2013a,
2013b, 2014) and a distance running study by Kiernan et al. (2018) monitoring participants during
general training [5,7,8,46].
3.4. Data Sampling, Collection and Processing
Four articles did not state the sampling frequency of the devices that were used [38,43,48,54] but
for those that did, this ranged between 10 Hz and 1000 Hz, with the most common frequency used
being 100 Hz by eight systems [32,35–37,39,49,52,55]. Sampling frequency was justified in four
articles: 25 Hz was deemed ‘competent for obtaining enough knowledge of performance’ with
regards to table tennis blocks by Guo et al. (2010) [42], and the accelerometers used by Kiernan et al.
(2018) had a frequency that was double that of observed vertical ground reaction forces (vGRFs) in
running [46]. The SportSemble nodes in baseball contained accelerometers with differing sampling
frequencies (1000 Hz and 100 Hz) in order to record slow and fast motion [49]. This was recognized
as a limitation of optical motion trackers. The higher sampling frequency of the SportSemble nodes
enabled more detail about the pitching movement to be obtained compared to an optical motion
analysis system sampling at 180 Hz, which is important when considering variables such as peak
acceleration. In contrast, an inertial measurement unit (IMU) developed at Loughborough University
was used by Philpott et al. (2014) to assess sprint starts in athletics had a much lower sampling
Sensors 2019, 19, 1597 9 of 28
frequency compared to Vicon (Oxford Metrics, Oxford, UK) (50 Hz and 250 Hz, respectively) [45].
The few data points collected by the IMU do not make it suitable for the explosive nature of the sprint
start sequence. However, a sampling frequency of 50 Hz was deemed suitable for capturing the
dynamics of the pole movement in Nordic walking [56].
Some of the systems recorded the output of the sensor onto a memory card (including micro and
mini SD cards) (n = 7) [6,8,31,46,52,54,56], used data loggers (n = 3) [5,7,36] and microcontrollers (n =
3) [4,41,49]. In these cases, data was visualised and processed after testing. Some systems employed
wireless data transfer (n = 11) [3,12,32,38,40,42,43,47,51,53,55], meaning that there was potential for
data to be received and analysed in real-time, with five specifically stating the use of Bluetooth
[38,40,43,51,53] but still data was processed after data collection.
Real-time feedback was used in only 2 articles [25,46]. Wood et al. (2014) used auditory feedback
in order to reduce tibial peak-positive acceleration (PPA) in runners [44], while the “ISWIM” system
used by Li et al. (2016) provided live feedback in the form of vibrations [6]. In both cases, participants
were instructed to modify running or swimming biomechanics based solely on the feedback
produced from the devices. Runners were able to significantly reduce PPAs throughout a 25 minute
testing period from 5.9 ± 0.7g to 5.4 ± 0.7g [44]. The case was similar with the “ISWIM” system—the
vibratory feedback improved body rotation angles and as a result increased stroke rate and improved
session times in three out of four participants [6]. Feedback in both systems led to a change in
biomechanics without any technical input from coaches, indicating that these are systems that
athletes could use on their own.
The elbow torque-measurement device (ETD) studied by Makhni et al. (2018) used data
transmission via Bluetooth to display the output of the sensor, including parameters such as arm
speed, shoulder rotation and torque across the medial elbow, on a smartphone application [48].
However, the authors were not concerned with the feedback produced from the device, so there is
not any indication as to its utility. This type of setup is also mentioned by Mitsui et al. (2015) to
improve a golfer’s swing [51] but it was unclear whether the output was displayed in real-time or not
and the impact of feedback on improving performance.
Fifteen studies mentioned data being filtered before being subject to analysis and a variety of
filters were used: second- [4,34], third- [39] and fifth- [45] order Butterworth filters; a low-pass median
filter [5,7]; a second-order low-pass filter [3]; the Madgwick Altitude and Heading Reference System
(AHRS) orientation filter [41,52]; a band pass filter [42]; a first-order analogue filter [49]; Kalman
filtering and algorithms [9,12,34]; and a three-point moving average filter [54]. Kalman filtering was
used when a wearable system contained multiple sensors in order to fuse the data, however, it is
limited at higher speeds, with Blair et al. (2018) noting higher measurement errors in segments
experiencing higher movement velocities in different kicking codes, but a good concurrent validity
was observed when comparing the IMS to Vicon (Oxford Metrics, Oxford, UK) [9]. In three instances,
commercially available data processing software from Xsens (MVN Biomech Studio, MVN Studio
and MT Manager 4.2.1, Xsesns Technologies B.V.m Enschede, The Netherlands) was used to process
data which uses Kalman filters to fuse sensor data [9,12,40]. In all other cases, custom-made scripts
were used to process data.
3.5. Recording and Usage Lifetime of Wearable Systems
Systems employed different recording methods, leading to a variation in the amount of data that
could be recorded and the usage lifetime. Lithium ion polymer batteries (LiPo) were found in many
accelerometers, IMUs and inertial and magnetic measurement units (IMMUs) [33,49,55,61–63]. The
exact Physilog sensors (GaitUp, Lausanne, Switzerland) used by Chardonnens et al. (2013a, 2013b,
2014) were not stated [5,7,8] but data on Physilog 4 measurement units (GaitUp, Lausanne,
Switzerland) state the use of rechargeable LiPo batteries. Nickel-metal hydride (NiMH) batteries
were also used, chosen for their cost-efficiency and availability [35,36,43]. The highest storage
capacity listed was of the Opal IMMUs (APDM Wearable Technologies, Portland, OR, USA) which
are able to store approximately 720 hours of data internally used by Fantozzi et al. (2016) [34,64]. The
Sensors 2019, 19, 1597 10 of 28
SwimMaster system is able to record continuously for up to 48 hours [4]. A summary of the battery
and storage features of the devices used is listed in Table 4.
Table 4. Battery and storage features of the wearable device systems.
Device Battery Type Battery Life Storage Capacity Application
MVN Link IMS
(Xsens
Technologies
B.V., Enschede,
The
Netherlands)
One battery Ten hours - Rugby and
football [9]
Moven suit
(Xsens
Technologies
B.V., Enschede,
The
Netherlands)
- Approximately
three hours [65] Snowboarding
[3]
Opal IMMUs
(APDM
Wearable
Technologies,
Portland, OR,
USA)
-
Up to 16 hours
depending on
whether data is
logged or
streamed
Internal storage
of up to 8GB
(approximately
720 hours) [64]
Swimming [34]
Physilog 4
inertial
measurement
unit (IMU)
(GaitUp,
Lausanne,
Switzerland)
LiPo battery Up to 23 hours
Internal storage
of 4GB,
providing 9 days
of storage at 200
Hz [63]
Skiing [5,7,8]
SportSemble
node
145 mAh LiPo
rechargeable
battery
Up to three
hours
Flash memory of
116 kB (allowing
each node to
store around 11
seconds of data)
Baseball [49]
x-IMU magnetic,
angular rate and
gravity (MARG)
sensors (x-io
Technologies
Limited, Bristol,
UK)
LiPo battery (on-
board charging
via USB) [59]
- - Football [33]
G-Link-LXRS tri-
axial
accelerometer
(LORD
MicroStrain,
Williston, VT,
USA)
22mAh LiPo
battery (at 3.7V) - 2 MB [61] Running [44]
Motus sensor
(Motus Global,
10 mAH lithium
ion battery
(rapid charging
Up to eight
hours
Store 450+
throws Baseball [48]
Sensors 2019, 19, 1597 11 of 28
Rockville Centre,
NY, USA)
using a
microUSB)
SABELSense
IMU
High density
LiPo battery
Approximately
three hours
8 GB on a micro
SD card [62] Netball [52]
IMU nodes in
CanoeSense
system
1200 mAHh LiPo
batteries
More than six
hours - Canoeing [55]
Hand
Monitoring
Module
1500 mAh NiMh
batteries (at 1.5V
per cell)
- - Badminton [43]
Pedar pressure
insole system
(novel gmbh,
Munich,
Germany)
NiMh batteries - 2 GB SD card
[60] Skiing [35,36]
TSND121
wearable sensors
(ATR-Promotion,
Kyoto, Japan)
- Approximately
six hours
5.8 hours of
memory storage
at 100 Hz [58]
Golf [51]
SwimMaster
System
250 mAh battery
at 3.7 V) Up to 48 hours 1 GB of flash
memory Swimming [4]
BSN nodes - - 512 kB of flash
memory Rowing [47]
XSens MTw
IMMUs (Xsens
Technologies
B.V., Enschede,
The
Netherlands)
- Approximately
three hours - Running [12]
3.6. Validation and Reliability Using Gold-Standard Measurements
The Vicon motion capture system (Oxford Metrics, Oxford, UK) was used as a gold-standard
reference for wearable systems used in football [9,33], rugby [9], baseball [50], athletics [45] and
netball [52]. Philpott et al. (2014) used Kistler force platforms (Kistler Instruments Ltd, Hampshire,
UK) alongside the Vicon (Oxford Metrics, Oxford, UK) camera set-up [45] when looking at sprinting
in athletics. Optical based systems, such as BTS Bioengineering stereo-photogrammetric system (BTS
Bioengineering Corp., Quincy, MA, USA) and XOS Technologies (Wilmington, MA, USA) optical
motion analysis system), were also used as gold standards when observing movement in swimming
[34], rowing [47] and baseball [49]. Kistler force plates (Kistler Instruments Ltd, Hampshire, UK) were
also used in snowboarding by Krüger et al. and in skiing by Nakazato et al. (2011, 2013) [3,35,36]. The
reliability of the wearable systems in comparison to the gold-standard references are detailed in Table
5. Results obtained from experimentation by Chardonnens et al. (2013a, 2014), Gandy et al. (2018),
Meamarbashi et al. (2010) and Munz et al. (2013) were compared to values reported in literature
[5,7,31,39], detailed in Table 6.
Table 5. Wearable systems compared to a gold-standard reference.
Article and
Sport System Used Gold Standard Reliability
Akins et al.
(2015)—
Football [33]
Two x-IMU
magnetic,
angular rate
8 camera Vicon
motion capture
system (Oxford
Concurrent criterion validity was
assessed by comparing ankle plantar
flexion, inversion and internal rotation
Sensors 2019, 19, 1597 12 of 28
and gravity
(MARG)
sensors (x-io
Technologies
Limited,
Bristol, UK)
Metrics, Oxford,
UK)
angles between the MARG sensors and
Vicon (Oxford Metrics, Oxford, UK).
High correlation between sagittal plane
data (r = 0.900 to 0.975) for all
manoeuvres and RMSE was < 5° for
drop landing, drop jump and stop
jump manoeuvres. Poor correlation
between frontal plane data (r = −0.074
to 0.562) and RMSE > 3° for all
manoeuvres. Poor correlation between
transverse plane data and RMSE > 3°
for all manoeuvres.
Blair et al.
(2018)—
Australian
football,
football and
rugby [9]
MVN Link IMS
– 17 inertial
sensors (Xsens
Technologies
B.V., Enschede,
The
Netherlands)
12 camera Vicon
motion capture
system (Oxford
Metrics, Oxford,
UK)
Trivial to small errors between the IMS
and Vicon (Oxford Metrics, Oxford,
UK) in all kinematic parameters (0.1 to
5.8%). Trivial to small differences were
found (0.2 to 5.8%) were found
between linear velocities (foot and
pelvis), angular velocities (knee, shank
and thigh), sagittal joint (knee and hip)
and segment angle (shank and pelvis)
means.
Fantozzi et al.
(2016)—
Swimming [34]
Seven Opal
IMMU units
(APDM
Wearable
Technologies,
Portland, OR,
USA)
7 camera
SMART-DX 7000
stereo-
photogrammetric
system (BTS
Bioengineering
Corp., Quincy,
MA, USA)
Better agreement between the two
systems was found during breaststroke
compared to front crawl (CMC = 0.99
compared to 0.97, R = 0.99 compared to
0.95 and RMSE = 5° compared to 7°).
King et al.
(2009)—
Rowing [47]
Three BSN
nodes with
inertial sensors
SMART-D
system (BTS
Bioengineering
Corp., Quincy,
MA, USA)
Mean error between the BSN nodes
and BTS system: 3.6° in femur rotation,
4.0° for thoraco-lumbar rotation and
4.1° in sacrum rotation. Accuracy of
BSN nodes not as fine as BTS system
resolution.
Koda et al.
(2010)—
Baseball [50]
3D sensor
containing two
types of
accelerometer
and gyroscope
Vicon motion
capture system
(Vicon460,
Oxford Metrics,
Oxford, UK))
Correlation coefficient (R) and RMS of
error calculated between estimated
position by 3D sensor and position
measured by the Vicon system (Oxford
Metrics, Oxford, UK). For the shoulder,
elbow and wrist, R in the x and y
direction showed excellent agreement
(> 0.95) but was smaller for the z
direction (0.73 to 0.92). However RMS
was less than 10cm for the z direction
and between 13 cm to 18 cm for the x
and y directions.
Krüger et al.
(2009)—
Snowboarding
[3]
Moven IMS—
16 sensor units
(Xsens
Technologies
Three
synchronized
cameras; Kistler
force plate
The IMS system had a moderate
accuracy when compared to the
cameras. Mean deviation in knee
angles for left leg and right leg were
Sensors 2019, 19, 1597 13 of 28
B.V., Enschede,
The
Netherlands);T
and T
Medilogic
bilateral insole
measurement
(T and T
Medilogic
Medizintechnik
GmbH,
Schönefeld,
Germany)
(Kistler
Instruments Ltd,
Hampshire, UK)
4.8° and 3.1° respectively. Correlation
coefficients were high (0.96 for the left
knee angle and 0.77 for the right knee
angle). The insoles had a milted
accuracy with a mean RMSE of 28%.
Lapinski et al.
(2009)—
Baseball [49]
Five
SportSemble
nodes – inertial
measurement
units (IMUs)
10 camera XOS
Technologies
(Wilmington,
MA, USA)
optical motion
analysis system
No statistical difference between
average shoulder internal rotation
velocity in pitching measured by the
IMUs and XOS Technologies system
was found. Average standard
deviation for IMUs was 6% compared
to 15% for the optical system. In
batting, the average error of bat speed
at time of impact was 4.8%.
Nakazato et al.
(2011)—Skiing
[36]
Pedar pressure
insole system
(novel gmbh,
Munich,
Germany)
Two Kistler
portable force
plates (Kistler
Instruments Ltd,
Hampshire, UK)
The mean absolute difference of the
vertical ground reaction force (vGRF)
mean between the two systems ranged
from 0.45 to −0.23 N/BW on the outside
leg, from -0.19 to -0.10 N/BW on the
inside leg and from −0.25 to 0.13 N/BW
during the edge changing phase.
Differences were influenced by the
skier’s level, skiing mode and pitch.
Nakazato et al.
(2013)—kiing
[35]
Pedar pressure
insole system
(novel gmbh,
Munich,
Germany)
Two Kistler
portable force
plates (Kistler
Instruments Ltd,
Hampshire, UK)
Similarity coefficients between the two
systems were contrary or low in the x
direction during the outside and inside
phases (−0.95 to 0.26 and −0.53 to 0.40
respectively). Highly similar time
characteristics were indicated in the y
direction for the outside phase (0.92 to
0.96) and were lower for the inside
phase (0.15 to 0.78).
Philpott et al.
(2014)—
Athletics [45]
Wireless IMU
14 Vicon T-Series
cameras (Oxford
Metrics, Oxford,
UK); two Kistler
force platforms
(Kistler
Instruments Ltd,
Hampshire, UK)
The mean correlation coefficient
between the IMU and Vicon (Oxford
Metrics, Oxford, UK) was 0.907. The
timing accuracy of the IMU was 1.26
frames and the acceleration mean
accuracy was 1.81 m/s².
Shepherd et al.
(2017)—
Netball [52]
SABELSense
IMU sensor
10 camera Vicon
motion capture
system (Oxford
The IMU overestimated the Vicon
(Oxford Metrics, Oxford, UK) angle of
the forearm at release by 4.03°, which
Sensors 2019, 19, 1597 14 of 28
Metrics, Oxford,
UK)
was deemed an appropriate level of
accuracy.
Table 6. Wearable systems compared to values reported in literature.
Article and
Sport System Used Reliability
Chardonnens
et al. (2013a)—
Skiing [7]
Seven Physilog
inertial
measurement
units (IMUs)
(GaitUp,
Lausanne,
Switzerland)
Validity of the system was assessed by comparing
ski horizontal angle at landing impact to hill slope: –
0.2 ± 4.8°, max value 11.5°. When compared to
literature data, differences were smaller than 6° for
75% of the angles and smaller than 15° for 90% of
the angles.
Chardonnens
et al. (2014)—
Skiing [5]
Seven Physilog
IMUs (GaitUp,
Lausanne,
Switzerland)
Maximum centre of mass (CoM) velocity for Group
1 was 2.51 ± 0.83 m/s and for Group 2 was 2.23 ± 0.28
m/s compared to 2.3 m/s reported in literature.
Meamarbashi
et al. (2010)—
Football [31]
Sensor module
and data
logger
Angular velocity of the shank in the x-axis of 1911.2
± 241.6°/s is comparable with the widely accepted
value reported by Nunome et al. (2006) of 2257 ±
224.6° [66]
Munz et al.
(2013)—
Equestrian [39]
Two MTx
inertial sensors
(Xsens
Technologies
B.V., Enschede,
The
Netherlands)
Inter-individual differences were found for anterior-
posterior (AP) and lateral (LT) angles in sitting trot
(13.3 ± 2.3° and 6.4 ± 1.1° respectively),
corresponding well with values in literature (13.9 ±
2.2° and 5.1 ± 1.1° respectively) reported by Byström
et al. (2009) [67]
Accuracy of the systems used were reported using different measures in other articles. The
inertial measurement units (IMU) sensors in the MVN system used by Gandy et al. (2018) were stated
to have a 3-dimensional orientation accuracy within 1° [40]. Gawsalyan et al. (2017) reported a typical
RMSE of around 7° for the magnetic, angular rate and gravity (MARG) sensors used in upper limb
motion detection in cricket [41]. The “ISWIM” system was compared to a stopwatch, not considered
a gold standard, reporting an average difference of 0.56 seconds between timings [6]. Jacob et al.
(2017) reported accuracy of the flex sensors as a detection percentage, displaying a 70% detection
ability in identifying five badminton grips [43]. The accuracy of the elbow torque-measurement
device for monitoring baseball pitches was much higher, being able to detect 97.4% of pitches thrown
by a given player [48]. A wearable sensor detecting football kicks only failed to detect six kicks out of
a total of 450 [32]. The IMU for assessing skill level in volleyball had an average accuracy of 94% [54].
3.7. Application of Technology
Different applications were reported for the wearable systems and included injury prevention;
quantifying skill level and expertise; improving technique; and characterizing movements. Injury
prevention was the motivation behind twelve studies [3,12,33,35–37,40,44,46,48–50]. For instance, in
running, high tibial peak-positive accelerations (PPAs) are linked to the risk of tibial stress fracture
and as mentioned in Section 3.4, the provision of auditory feedback was able to temporarily reduce
PPAs in participants [44]. By correlating the pitch of the signal output to the magnitude of PPAs,
athletes were able to audibly understand the impact they were generating during each step. Fatigue
is considered as another risk factor in relation to injury and the change in running mechanics was
observed during a marathon [12]. Despite being ideal conditions to monitor fatigue and significant
Sensors 2019, 19, 1597 15 of 28
changes in mechanics, data was only collected from three participants, which is not enough to
produce an analysis representative of runners in general. Yet another variable was considered as an
indication of injury risk by Kiernan et al. (2018)—peak vertical ground reaction force (vGRF) was
measured in injured and non-injured runners during every day training [46]. A higher peak vGRF
was produced by injured runners, which is something that could be used by coaches and support
staff to generate a threshold for injury potential.
Injury prevention was also considered in baseball [48–50], with three authors of included articles
assessing different parameters. Lapinski et al. (2009) studied a combination of kinetics and kinematics
of the upper body [49], Makhni et al. (2018) focused on elbow torque [48] and Koda et al. (2010)
observed kinematics of the upper limb [50]. A combination of accelerometers and gyroscopes was
used in all three articles.
In other studies, authors were able to accurately measure parameters that were connected to
injury-risk, such as high forces produced in middle-turns in skiing [37] and hip asymmetry in horse
riders [40], suggesting their possibility of influencing rehabilitation or aiding elite coaches and
athletes. However, there was no indication on the utility of the results in making biomechanical
changes to reduce injuries risk. Magnetic, angular rate and gravity (MARG) sensors used by Akins et
al. (2015) in football showed promise of clinical utility with regards to sagittal plane movement only
[33] but the impact of these measures was not demonstrated in practice.
Wearable technology was used to quantify skill level and expertise by five authors [5,7,8,38,54].
The inertial measurement units (IMUs) used to assess the skill level of volleyball players had a 94%
accuracy in determining a players’ ability. The data was also compiled into a database, increasing the
impact of the sensor as this information could be used by sports scientists and professional coaches
[54]. Patterson et al. (2010) also used IMUs to quantify the expertise of show jumping horse riders.
The authors came to the conclusion that their hypothesis was confirmed in that novice riders were
more unbalanced during jumps and differences were recorded between experienced and novice
riders in the variables measured [38], but there was not any statistical analysis performed to support
this or explain the significance of these differences.
Movement recognition using sensors was also explored in sports such as dressage, cricket,
football, rugby, badminton, rowing, swimming and table tennis [9,32,34,39,41–43,47]. In dressage
authors reported kinematic differences between two riders with similar levels of experience [39] and
in rowing, King et al. (2009) were able to distinguish between poor and good technique but this was
not quantified [39,47]. Yet in the study by Guo et al. (2010), accelerations were used to characterize
the table tennis block movement as well as distinguish between different athlete levels by comparing
the standard deviation in acceleration [42]. Acceleration and force values were also used to
characterize Nordic walking phases by Mocera et al. (2018) [56]. The hand monitoring module
(HMM) for monitoring the grip in badminton had only a 70% detection ability between the five
different grips [43]. Accuracy of the wearable sensor used by Kim et al. (2016) was also reported: out
of 450 kicks, only six were not detected and the sensor was also able to discriminate kicking from
other motion such as walking [32]. In cricket, MARG sensors were used to analyse upper limb motion
in cricketers to detect potentially illegal bowling actions.
4. Discussion
The aim of this review was to determine the use and application of wearable technology in sport.
From the reviewed articles it can be seen that a variety of wearable systems (including inertial
sensors, pressure insoles and flex sensors) were able to measure kinetic and kinematic parameters in
over 15 different sports. The common themes were injury prevention, performance assessment,
movement recognition and skill level classification.
Out of these themes, injury prevention is an area with great potential when the cost of injuries
and harm to athletes is considered. However, this potential has not been realised when compared to
the other themes. Difficulties are presented by the many definitions of sports injury in literature and
the barriers to describing their incidence: defining and gaining access to the population of interest
and obtaining a suitable measure of exposure time [68]. Anecdotal experience is often the basis for
Sensors 2019, 19, 1597 16 of 28
preventive measures, such as strength training and stretching [69]; little of it is evidence-based as
there are few randomised controlled trials reported in the literature [68,69] and this is especially the
case for overuse injuries [70]. Moreover, there is a lack in the use of biomechanical measures as a
means of objectively preventing injury as it is not clear which measures should be used.
However, data and technology have the potential to be used to predict injury, forming the basis
for individualised programmes and allowing monitoring over a period of time, as demonstrated by
Kiernan et al. (2018) who studied participants over a 60-day period [46]. To fully exploit this potential
in injury prevention, however, there is still a need of identifying which biomechanical data obtained
from wearable technology is the most useful as a predictor of injury.
4.1. Quality of Articles
The quality of the included papers varied greatly, with regards to descriptions of methods,
sensor location and processing techniques. The population studied also varied, with participants
ranging from an amateur to professional level. As stated by Düking et al. (2018), the study population
should reflect the intended user of the wearable technology as different populations behave
differently [19]. There was no standardization within each sport in terms of population size and
experience. Swimming was studied by Bächlin et al. (2012) and Fantozzi et al. (2016) with 16
participants (from occasional to elite swimmers) in the former article and 8 (no experience level
stated) in the latter [4,34]. Smaller sample sizes can create population bias in the results, making it
difficult to trust the output.
There was also a discrepancy in detail given for the tasks conducted by study participants and
the description of the location of the sensors. The amount of detail given affects the ability of a study
to be accurately replicated by another person. When multiple IMUs are used, the output can be
combined using a model to reconstruct human motion and trajectories, but often this is dependent
on using specific anatomical landmarks, so sensor placement can affect the reliability and accuracy
of the reconstruction [71].
4.2. Wearable Systems Used
Commercially available sensors were used in the majority of studies, the most popular being
those produced by Xsens Technologies B.V. (Enschede, The Netherlands) in the form of individual
sensor nodes and sensor suits in seven articles in skiing, equestrian, football, rugby, running and
snowboarding [3,9,12,37–40]. A possible explanation for this could be the accuracy of these inertial
sensors in comparison to a gold-standard reference. The MVN Link IMS used by Blair et al. (2018)
[9] was compared to the Vicon motion capture system (Oxford Metrics, Oxford, UK) and small errors
were reported (0.1 to 5.8%) between the two systems. Results from MTx inertial sensors analysing
pelvis motion corresponded well with previously reported values in the literature where reflective
markers and infrared cameras were used to study the same movement [39,67].
The cost of these devices is what makes them prohibitive for widespread use. The MTw Awinda
3DOF Wireless Motion Tracker (Xsens Technologies B.V., Enschede, The Netherlands) costs €400 per
unit [72], while the Physilog 5 inertial measurement unit (IMU) (GaitUp, Lausanne, Switzerland) is
slightly more at €499 per unit [73]. When you consider that Chardonnens et al. (2013, 2014) [5,7] used
seven Physilog sensors to monitor skiing kinematics just of the lower limbs, the total cost associated
with the setup rises dramatically. This limits the technology to high performance or private
organizations that have a budget to spend on equipment, but this is only representative of a small
section of the sporting population.
An alternative to commercially available sensors are those that have been developed in-house,
which have also been shown to be comparable to motion capture systems. ADXL193 and ADXL320
accelerometers from Analog Devices were components in the 3D sensor used by Koda et al. (2010)
[50] with estimation errors of about 10% but are a fraction of the cost of the x-io Technologies IMU
(Bristol, UK) used by Akins et al. (2015) [33,59,74]. The ADXL193 is being sold for £18 by one supplier
[75], while the x-IMU has a cost of £309 with housing and battery [59]. Other comparable features
between the two devices included sampling frequency and battery lifetimes.
Sensors 2019, 19, 1597 17 of 28
The ease of use of wearable systems must be considered. Sensors requiring complex set ups or
technicians are not providing additional benefit compared to motion capture systems. For instance,
the elbow torque-measurement device (ETD) studied by Makhni et al. (2018) [48] and the
compression sleeve housing it were positioned by technicians and this positioning was constantly
monitored. However, this process takes approximately a minute and if it is easy for coaches or other
baseball players to learn and carry out it could contribute to device uptake. The fact that the activity
monitor employed by Kiernan et al. (2018) [46] was placed by the participants themselves
demonstrates its ease of use and indicates that small changes in positioning will not have a significant
impact on the device output. The ease of using the Xsens MVN suit (Xsens Technologies B.V.,
Enschede, The Netherlands) was mentioned by Gandy et al. (2014) [40]. As the inertial sensors are
embedded in the suit, it allowed for quicker changes between participants during the study.
Only three studies considered the impact of the technology used on participants [48,52,56] and
two did so in a quantitative manner [48,52]. In a sport such as Nordic walking where the equipment
is so light (180 g per pole), any technological additions must have minimal impact in terms of weight
which was considered by the authors [56]. However, no indication of the weight of the acquisition
system was given nor a comparison between this setup and poles that had not been equipped with
any technology. This would have provided a clear indication of its impact on the participant’s
movements. An important result from the study by Shepherd et al. (2017) [52] in netball was the
comparison of player performance when wearing the IMU and when not wearing it. The Pearson’s
correlation coefficient, used for measuring the linear dependence between the conditions of wearing
the IMU or not, was approximately equal to one [52], meaning that there was no significant impact
on performance when wearing the IMU, an indicator of unobtrusiveness which could help with
increasing the uptake of the device. Makhni et al. (2018) [48] followed up with participants after
testing and 95% indicated that they thought it was important to monitor the stress on the arm when
throwing and 73% indicated that they would alter their technique based on the results of the ETD.
However, there was a significant difference between the percentage of those surveyed as to whether
they would use the ETD in a practice or game setting (91% compared to 41%) [48]. Further
information as to why this was the case would have been useful as for understanding what athletes
expect from wearable devices if they are to use them in a competition setting.
4.3. Data Collection and Processing
Motion capture systems and wearable devices are able to provide athletes and coaches with
more detailed analysis of the biomechanics involved in a certain sport, enhancing the methods
already employed such as video analysis. However, systems such as Vicon (Oxford Metrics, Oxford,
UK) have lengthy data processing times and require familiarity with how the system works. This is
being considered by researchers, who recognize the importance of making data easy to interpret and
also providing simple real-time feedback to athletes. The benefits of this can be seen in the systems
studied by Li et al. (2016) [6] and Wood et al. (2014) [44] where vibratory and audible feedback is
provided to the athletes and has been able to change movement biomechanics by reducing tibial
impact and body rotation but this type of feedback is still novel.
Both Bächlin et al. (2012) [4] and Wang et al. (2016) [55] were aware of the importance of being
able to provide real-time feedback for the SwimMaster and CanoeSense monitoring systems,
respectively, and this was indicated in plans for further work, which would allow continuous
monitoring and swimmers to make changes without a coach [4] or a coach to assess synchronicity
between athletes and its impact on canoe propulsion [55].
As feedback from the “ISWIMsystem was provided by the device itself and not an external
source, there was not a concern for signal loss. For other wearable technology considering real-time
feedback as grounds or future work, wireless data transfer was employed and some devices were
affected by interference and signal loss. In the case of Reenalda et al. (2016), data was transferred
wirelessly from inertial and magnetic measurement units (IMMUs) to a base station (Awinda Master,
Xsens Technologies B.V., Enschede, The Netherlands)) while runners completed a marathon [12].
This base station was mounted on the handlebars of a bike that travelled alongside the athlete, with
Sensors 2019, 19, 1597 18 of 28
the antenna raised up to make sure that elements such as road signs and other runners did not
interfere. Despite this, signal loss meant that data could only be collected for three out of the five
initial participants [12]. A similar problem was encountered by Gandy et al. (2014) where wireless
signals were lost at a consistent location during testing, potentially due to the presence of a radio
mast [40]. Wireless data transfer has been pursued as a means of providing a less invasive system,
however signal loss in outdoor environments or due to other objects causing interference limits its
potential.
4.4. Testing Environment
Only five studies were conducted in a laboratory setting [9,33,34,44,47]. The remaining studies
were conducted in a sporting environment [3–8,12,31,35,36,37,38–42,45,46,48–50,52–55] with the
exception of three, where the location was not stated [32,43,51]. The conditions of testing are really
important as revealed by the study conducted by Fantozzi et al. (2016) where simulated swimming
altered the swimmers’ biomechanics [34]. Although this is suitable for testing the reliability of the
inertial and magnetic measurement units (IMMUs), it is not necessarily suitable for considering
kinematic and kinetic factors relating to injury or performance. The unpredictability of the conditions
in an outdoor environment in sports such as running can influence the biomechanical motions of an
athlete, therefore, it is important for wearable systems to be tested in these scenarios and allow more
accurate kinetic and kinematic measures to be obtained.
Conducting tests in a sports setting has the advantage of being able to factor in elements that
may affect readings, such as drag in swimming, as well as having a better understanding of how an
athlete moves in their chosen sport. Furthermore, monitoring an athlete in a training or competition
environment is a good test of whether or not a system is unobtrusive as its performance is under
scrutiny. Under laboratory conditions, participants may expect sensors to be uncomfortable but
would generally not put up with them causing discomfort or affecting their range of motion during
training or competition.
4.5. Application of Wearable Technology
The potential of wearable technology is huge. Across the included articles different applications
were reported: the prevention of injury; characterizing movements; analysing technique and
performance; and identifying skill level. Participants from a recreational to elite level were selected
in the various studies, demonstrating that these devices are not just for athletes at the top of their
game but have a wider target audience, increasing the impact of wearables.
There was a crossover between themes, such as the combination of movement classification and
performance in the study by Shepherd et al. (2017) in netball [52], as kinematic observations can be
used to influence coaching practices to achieve a more consistent forearm angle at ball release, which
would increase the likelihood of scoring during a game. Addressing more than one theme elevates
the utility of a technology as it means more people can benefit from it in different ways.
The demand for wearable devices is there, especially where injury is concerned: twelve studies
considered factors related to injury [3,12,33,35,36,37,40,44,46,48–50]. When you consider injury
statistics reported by Lapinski et al. (2009) in baseball [49], where the percentage of pitchers with
injuries sufficient enough to prevent them from throwing increased from 50% in 1973 [76] to over
75% in 1999 [77], there is hope that technology can reverse this trend.
Both running and baseball injuries were each studied by three different authors, each looking at
different parameters. However, in each sport, only one author was able to convey the effect of the
device on study participants [44,48]. It was clear to see the influence of providing feedback in the
form of audible beeps directly to athletes in the case of Wood et al. (2014) [44]. This simple method is
beneficial as it allows athletes to still have an awareness of their training environment without
looking at visual information in the form of figures or numbers. As discussed in Section 4.2, Makhni
et al. (2018) was the closest to demonstrating buy-in from athletes in terms of using the device in
training [48]. Furthermore, the elbow torque-measurement device (ETD) used was linked to a
smartphone application, where quantified data may be more beneficial for coaches who can use the
Sensors 2019, 19, 1597 19 of 28
readouts to compare athletes. There is an advantage of smartphone applications to all users in that it
is integrated into a device that is used every day, additional equipment is not needed besides the
sensor.
What this information demonstrates is that we are still at an exploratory phase of using wearable
technology in sports. Despite all studies being able to measure kinematic and kinetic parameters with
these devices, only a few were able to translate the output into something suitable for actual use by
coaches and athletes [6,44,48,51]. This opens up the possibility to future studies to explore how to
take a device from the research stage to the sporting environment by considering athlete comfort and
ease of interpreting device output.
It is also evident from reviewing these articles that there is a wearable technology market for
both athletes and coaches. Devices that are able to give audible and vibratory feedback are more
useful for athletes who can then focus on the movements they are performing and their environment,
also enabling them to make biomechanical changes without the presence of a coach. Where the device
output can be displayed as readout on a smartphone or tablet is more suitable for coaches, but when
developing these accompanying applications, care must be taken to only provide data that is useful
and easy to interpret.
4.6. Review Limitations
Limitations must be considered when interpreting the findings of this review. The search was
limited to seven databases, albeit integrated by reference lists and hand searches to identify other
relevant papers. The results of this review are also limited by the choice of search terms and inclusion
criteria—using different terms and criteria may have changed the number of articles included.
However, the search terms and criteria were guided by similar reviews that have been published
previously. Included articles were restricted to those published in English, posing a language bias to
article selection. The quality assessment checklist was formed based on a review of wearable
technology for spine movement assessment [28] as a standardized tool was not found because study
quality was not reported in similar reviews.
5. Conclusions
This review highlighted the increase in research surrounding wearable technology as a means
to measure kinetic and kinematic parameters in sport to understand movement and differentiate
between skill levels. However, it is still not at a stage where there is a good translation to general
usage.
The most common type of device used were inertial measurement units, however, authors
explored stand-alone accelerometers and flex sensors also, both those commercially produced and
developed in-house. Devices were developed in-house as a way to reduce their cost, which will
ultimately have an impact on uptake when reaching the general market. Different applications were
reported, from injury prevention to assessing performance, with the long-term vision of influencing
coaching practices and athlete technique. There is potential for wearable technology to be used for
long-term monitoring, especially beneficial in injury prevention as it provides coaches and athletes
with the capacity to observe and analyse biomechanical risk factors over a defined exposure time,
with the ability to influence injury prevention models.
A significant advantage of these devices is the ability to monitor athletes in-field instead of inside
a laboratory. Laboratory testing introduces many limitations, while normal sports environments are
able to provide a more accurate setting for biomechanical measurements. Furthermore, a number of
studies validated the wearable technology against gold-standard reference, showing good concurrent
validity. Despite the measurement errors associated with inertial measurement units, they are able to
provide reliable measurements of joint kinematics and as a result, are a popular choice across
different sports.
Providing real-time feedback has been shown to influence technique in swimmers and runners,
but this is not yet a common feature across all sports. Wireless data transfer is a necessity but signal
loss needs to be minimized in order for data to be beneficial. Any output must also be easy to interpret
Sensors 2019, 19, 1597 20 of 28
if it is going to be adopted by athletes and coaches who may have limited experience when analysing
movement biomechanics data. Wireless data transfer has been addressed in a few studies, where data
was transferred to and displayed in smartphone applications.
There have been discrepancies in the amount of detail given in the studies carried out and the
wearable sensors that were used, but it is clear that they are able to provide accurate information
regarding biomechanics that can be exploited in a number of ways in sport.
Supplementary Materials: The following are available online at www.mdpi.com/xxx/s1, Table S1. Data
extracted from included articles.
Author Contributions: All authors contributed to conceive and design the study; Y.A. performed the data
retrieval; Y.A. and E.P evaluated title and abstracts of the retrieved papers for inclusion and compared results
through discussion. Any conflicts were resolved by A.H.M. Y.A. and E.P. analysed the included papers and
extracted useful information. Y.A. prepared the original draft and E.P. and A.H.M. assisted in reviewing and
editing the manuscript.
Funding: This research received no external funding
Conflicts of Interest: The authors declare no conflict of interest.
Sensors 2019, 19, 1597 1 of 28
Appendix A
Table A1. Quality assessment of included articles (L: Low, M: Medium, H: High).
Quality
Index Item
Number
Akins et al.
(2015)
Bächlin et
al. (2012)
Blair et al.
(2018)
Chardonnens
et al. (2013a)
Chardonnens
et al. (2013b)
Chardonnens
et al. (2014)
Fantozzi et
al. (2016)
Gandy et
al. (2018)
Gawsalyan
et al. (2017)
1 2 1 2 2 2 1 2 2 1
2 2 1 2 1 1 1 2 1 0
3 2 1 2 1 2 2 2 2 1
4 2 0 0 0 0 0 0 1 0
5 2 0 0 0 0 0 0 0 0
6 2 0 0 0 0 0 0 0 0
7 2 2 2 0 0 0 2 2 0
8 1 2 2 2 2 2 2 1 1
9 1 2 2 2 2 2 2 2 1
10 1 2 2 2 2 2 2 1 0
11 0 2 1 2 1 2 2 2 1
12 2 2 2 2 2 2 2 1 1
13 2 0 2 0 0 0 2 0 0
14 2 0 2 2 0 0 2 2 2
15 2 2 2 2 2 2 2 2 1
16 2 0 2 2 2 2 2 2 1
17 2 1 2 1 2 0 2 2 2
Total score /
out of 34 29 18 27 21 20 18 28 23 12
Percentage
score /% 85.3 52.9 79.4 61.8 58.8 52.9 82.4 67.6 35.3
Quality
category H M H M M M H H M
Quality
Index Item
Number
Guo et al.
(2010)
Jacob et al.
(2017)
Kiernan et al
(2018)
Kim et al.
(2016)
King et al.
(2009)
Koda et al.
(2010)
Krüger et
al. (2009)
Lapinski
et al.
(2009)
Lee et al.
(2017)
1 1 2 2 1 1 2 2 2 1
Sensors 2019, 19, 1597 2 of 28
2 1 0 2 0 0 2 2 1 0
3 1 1 2 1 0 2 1 1 2
4 0 0 2 0 0 0 0 0 0
5 0 0 0 0 0 0 0 0 0
6 0 0 0 0 0 0 0 0 0
7 2 1 1 2 0 1 1 1 1
8 2 2 2 2 2 2 2 1 2
9 1 2 2 2 2 1 1 1 1
10 1 2 2 1 0 2 2 2 1
11 2 0 1 0 0 0 2 2 0
12 2 2 2 2 2 2 2 2 2
13 0 0 0 0 2 2 2 2 0
14 0 1 0 1 2 2 2 2 0
15 1 1 2 2 1 2 2 1 2
16 1 0 2 0 1 2 1 0 0
17 1 1 2 1 0 0 2 2 0
Total score /
out of 34 16 15 24 15 13 22 24 20 12
Percentage
score /% 47.1 44.1 70.6 44.1 38.2 64.7 70.6 58.8 35.3
Quality
category M M H M M M H M M
Quality
Index Item
Number
Li et al.
(2016)
Makhni et
al. (2018)
Meamarbashi
et al. (2010)
Mitsui et al.
(2015)
Mocera et al.
(2018)
Munz et al.
(2013)
Nakazato
et al.
(2011)
Nakazto
et al.
(2013)
1 1 2 2 1 1 2 2 2
2 0 2 1 0 0 1 2 2
3 1 2 2 0 2 2 2 1
4 0 2 1 0 0 0 0 0
5 0 0 0 0 0 0 0 0
6 0 0 0 0 0 0 0 0
7 2 2 2 0 0 2 2 2
8 2 2 2 1 1 2 2 2
9 2 2 2 1 1 1 2 2
Sensors 2019, 19, 1597 3 of 28
10 1 2 2 0 0 2 1 1
11 0 0 0 0 1 2 0 0
12 2 2 2 2 2 2 2 2
13 0 0 0 0 0 0 2 2
14 0 2 0 0 0 0 2 2
15 2 2 2 1 2 2 2 2
16 0 2 2 0 0 2 2 2
17 0 2 0 0 1 2 2 2
Total score /
out of 34 13 26 20 6 11 22 25 24
Percentage
score /% 38.2 76.5 58.8 17.6 32.4 64.7 73.5 70.6
Quality
category M H M L L M H H
Quality
Index Item
Number
Patterson
et al. (2010)
Philpott et
al. (2014)
Reenalda et
al. (2016)
Shepherd et
al. (2017)
Taha et al.
(2016)
Wang et al.
(2018)
Wang et
al. (2016)
Wood et
al. (2014)
1 2
2
2
2
2
1
1
2
2 1
1
1
1
0
1
0
2
3 1
2
2
2
1
2
1
2
4 0
0
0
0
0
0
0
1
5 0
0
0
0
0
0
0
0
6 0
0
0
0
0
0
0
0
7 2
2
1
2
1
1
1
2
8 2
1
2
2
1
2
2
2
9 1
1
2
2
1
1
1
2
10 2
0
2
2
0
0
0
0
11 2
2
1
1
0
2
1
0
12 2
2
2
2
2
2
2
2
13 0
2
0
2
0
0
0
0
14 0
2
0
2
0
2
0
0
15 2
2
2
2
1
2
1
2
16 0
2
2
2
0
2
0
2
17 1
2
2
0
1
1
0
1
Sensors 2019, 19, 1597 4 of 28
Total score /
out of 34 18 23 21 24 10 19 10 20
Percentage
score /% 52.9 67.6 61.8 70.6 29.4 55.9 29.4 58.8
Quality
category M H M H L M L M
Sensors 2019, 19, 1597 28 of 28
Sensors 2019, 19, x; doi: FOR PEER REVIEW www.mdpi.com/journal/sensors
References
1. Jones, R.L.; Wallace, M. Another bad day at the training ground: Coping with ambiguity in the coaching
context. Sport Educ. Soc. 2005, 10, 119–134, doi:10.1080/1357332052000308792.
2. Pueo, B.; Jimenez-Olmedo, J. Application of motion capture technology for sport performance analysis.
Retos 2017, 32, 241–247.
3. Krüger, A.; Edelmann-Nusser, J. Biomechanical analysis in freestyle snowboarding: Application of a full-
body inertial measurement system and a bilateral insole measurement system. Sports Technol. 2009, 2, 17–
23, doi:10.1002/jst.89.
4. Bachlin, M.; Troster, G. Swimming performance and technique evaluation with wearable acceleration
sensors. Pervasive Mob. Comput. 2012, 8, 68–81, doi:10.1016/j.pmcj.2011.05.003.
5. Chardonnens, J.; Favre, J.; Cuendet, F.; Gremion, G.; Aminian, K. Measurement of the dynamics in ski
jumping using a wearable inertial sensor-based system. J. Sports Sci. 2014, 32, 591–600,
doi:10.1080/02640414.2013.845679.
6. Li, R.; Zibo, C.; WeeSit, L.; Lai, D.T. A wearable biofeedback control system based body area network for
freestyle swimming. In Proceedings of the 2016 38th Annual International Conference of the IEEE
Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA, 16–20 August 2016; Volume 2016,
pp. 1866–1869, doi:10.1109/EMBC.2016.7591084.
7. Chardonnens, J.; Favre, J.; Cuendet, F.; Gremion, G.; Aminian, K. A system to measure the kinematics
during the entire ski jump sequence using inertial sensors. J. Biomech. 2013, 46, 56–62,
doi:10.1016/j.jbiomech.2012.10.005.
8. Chardonnens, J.; Favre, J.; Cuendet, F.; Gremion, G.; Aminian, K. Characterization of lower-limbs inter-
segment coordination during the take-off extension in ski jumping. Hum. Mov. Sci. 2013, 32, 741–752,
doi:10.1016/j.humov.2013.01.010.
9. Blair, S.; Duthie, G.; Robertson, S.; Hopkins, W.; Ball, K. Concurrent validation of an inertial measurement
system to quantify kicking biomechanics in four football codes. J. Biomech. 2018, 73, 24–32,
doi:10.1016/j.jbiomech.2018.03.031.
10. Alonge, F.; Cucco, E.; Ippolito, F.; Pulizzotto, A. The use of accelerometers and gyroscopes to estimate hip
and knee angles on gait analysis. Sensors 2014, 14, 8430.
11. Papi, E.; Spulber, I.; Kotti, M.; Georgiou, P.; McGregor, A.H. Smart sensing system for combined activity
classification and estimation of knee range of motion. IEEE Sens. J. 2015, 15, 5535–5544,
doi:10.1109/JSEN.2015.2444441.
12. Reenalda, J.; Maartens, E.; Homan, L.; Buurke, J.H. Continuous three dimensional analysis of running
mechanics during a marathon by means of inertial magnetic measurement units to objectify changes in
running mechanics. J. Biomech. 2016, 49, 3362–3367, doi:10.1016/j.jbiomech.2016.08.032.
13. Wisbey, B.; Rattray, B.; Pyne, D. Quantifying Changes in AFL Player Game Demands Using GPS Tracking 2006
AFL Season; FitSense Australia: Florey, Australia, 2007.
14. Wisbey, B.; Montgomery, P.; Pyne, D. Quantifying Changes in AFL Player Game Demands Using GPS Tracking
2007 AFL Season; FitSense Australia: Florey, Australia, 2008.
15. Siegmund, G.P.; Guskiewicz, K.M.; Marshall, S.W.; DeMarco, A.L.; Bonin, S.J. Laboratory validation of two
wearable sensor systems for measuring head impact severity in football players. Ann. Biomed. Eng. 2016,
44, 1257–1274, doi:10.1007/s10439-015-1420-6.
16. Rawashdeh, S.A.; Rafeldt, D.A.; Uhl, T.L. Wearable imu for shoulder injury prevention in overhead sports.
Sensors 2016, 16, 1847.
17. MacDonald, K.; Bahr, R.; Baltich, J.; Whittaker, J.L.; Meeuwisse, W.H. Validation of an inertial measurement
unit for the measurement of jump count and height. Phys. Ther. Sport 2017, 25, 15–19,
doi:10.1016/j.ptsp.2016.12.001.
18. van der Kruk, E.; Reijne, M.M. Accuracy of human motion capture systems for sport applications; state-of-
the-art review. Eur. J. Sport Sci. 2018, 18, 806–819, doi:10.1080/17461391.2018.1463397.
19. Düking, P.; Fuss, F.K.; Holmberg, H.-C.; Sperlich, B. Recommendations for assessment of the reliability,
sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity.
JMIR mHealth uHealth 2018, 6, e102, doi:10.2196/mhealth.9341.
20. McMaster, D.T.; Gill, N.; Cronin, J.; McGuigan, M. A brief review of strength and ballistic assessment
methodologies in sport. Sports Med. 2014, 44, 603–623, doi:10.1007/s40279-014-0145-2.
Sensors 2019, 19, x FOR PEER REVIEW 2 of 28
21. Hamill, J.; Caldwell, G.E.; Derrick, T.R. Reconstructing digital signals using shannon’s sampling theorem.
J. Appl. Biomech. 1997, 13, 226–238, doi:10.1123/jab.13.2.226.
22. Robertson, G.E.; Caldwell, G.E.; Hamill, J.; Kamen, G.; Whittlesey, S. Research Methods in Biomechanics;
Human Kinetics: Champaign, IL, USA, 2004.
23. Camomilla, V.; Bergamini, E.; Fantozzi, S.; Vannozzi, G. Trends supporting the in-field use of wearable
inertial sensors for sport performance evaluation: A systematic review. Sensors 2018, 18, 873,
doi:10.3390/s18030873.
24. Chambers, R.; Gabbett, T.J.; Cole, M.H.; Beard, A. The use of wearable microsensors to quantify sport-
specific movements. Sports Med. 2015, 45, 1065–1081, doi:10.1007/s40279-015-0332-9.
25. Bunn, J.A.; Navalta, J.W.; Fountaine, C.J.; Reece, J.D. Current state of commercial wearable technology in
physical activity monitoring 2015–2017. Int. J. Exerc. Sci. 2018, 11, 503–515.
26. O’Driscoll, R.; Turicchi, J.; Beaulieu, K.; Scott, S.; Matu, J.; Deighton, K.; Finlayson, G.; Stubbs, J. How well
do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity
of current technologies. Br. J. Sports Med. 2018, doi:10.1136/bjsports-2018-099643.
27. Evenson, K.R.; Goto, M.M.; Furberg, R.D. Systematic review of the validity and reliability of consumer-
wearable activity trackers. Int. J. Behav. Nutr. Phys. Act. 2015, 12, 159.
28. Papi, E.; Koh, W.S.; McGregor, A.H. Wearable technology for spine movement assessment: A systematic
review. J. Biomech. 2017, 64, 186–197, doi:10.1016/j.jbiomech.2017.09.037.
29. Dobson, F.; Morris, M.E.; Baker, R.; Graham, H.K. Gait classification in children with cerebral palsy: A
systematic review. Gait Posture 2007, 25, 140–152, doi:10.1016/j.gaitpost.2006.01.003.
30. Needham, R.; Stebbins, J.; Chockalingam, N. Three-dimensional kinematics of the lumbar spine during gait
using marker-based systems: A systematic review. J. Med Eng. Technol. 2016, 40, 172–185,
doi:10.3109/03091902.2016.1154616.
31. Meamarbashi, A.; Reza, S.; Hosseini, S. Application of novel inertial technique to compare the kinematics
and kinetics of the legs in the soccer instep kick. J. Hum. Kinet. 2010, 23, 5–13.
32. Kim, W.; Kim, M. Soccer kick detection using a wearable sensor. In Proceedings of the 2016 International
Conference on Information and Communication Technology Convergence (ICTC), Jeju Island, Korea, 19–
21 October 2016; pp. 1207–1209.
33. Akins, J.S.; Heebner, N.R.; Lovalekar, M.; Sell, T.C. Reliability and validity of instrumented soccer
equipment. J. Appl. Biomech. 2015, 31, 195–201, doi:10.1123/jab.2014-0191.
34. Fantozzi, S.; Giovanardi, A.; Magalhães, F.A.; Di Michele, R.; Cortesi, M.; Gatta, G. Assessment of three-
dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-
magnetic measurement units. J. Sports Sci. 2016, 34, 1073–1080, doi:10.1080/02640414.2015.1088659.
35. Nakazato, K.; Scheiber, P.; Müller, E. Comparison between the force application point determined by
portable force plate system and the center of pressure determined by pressure insole system during alpine
skiing. Sports Eng. 2013, 16, 297–307, doi:10.1007/s12283-013-0119-x.
36. Nakazato, K.; Scheiber, P.; Müller, E. A comparison of ground reaction forces determined by portable force-
plate and pressure-insole systems in alpine skiing. J. Sports Sci. Med. 2011, 10, 754–762.
37. Lee, S.; Kim, K.; Kim, Y.H.; Lee, S.S. Motion anlaysis in lower extremity joints during ski carving turns
using wearble inertial sensors and plantar pressure sensors. In Proceedings of the 2017 IEEE International
Conference on Systems, Man, and Cybernetics, Banff, AB, Canada, 5–8 October 2017; pp. 695–698.
38. Patterson, M.; Doyle, J.; Cahill, E.; Caulfield, B.; McCarthy Persson, U. Quantifying show jumping horse
rider expertise using imus. In Proceedings of the 2010 Annual International Conference of the IEEE
Engineering in Medicine and Biology Society, EMBC’10, Buenos Aires, Argentina, 31 August–4 September
2010; pp. 684–687.
39. Munz, A.; Eckardt, F.; Heipertz-Hengst, C.; Peham, C.; Witte, K. A preliminary study of an inertial sensor-
based method for the assessment of human pelvis kinematics in dressage riding. J. Equine Vet. Sci. 2013, 33,
950–955, doi:10.1016/j.jevs.2013.02.002.
40. Gandy, E.A.; Bondi, A.; Hogg, R.; Pigott, T.M.C. A preliminary investigation of the use of inertial sensing
technology for the measurement of hip rotation asymmetry in horse riders. Sports Technol. 2014, 7, 79–88,
doi:10.1080/19346182.2014.905949.
41. Gawsalyan, S.; Janarthanan, T.S.; Thiruthanikan, N.; Shahintha, R.; Silva, P. Upper limb analysis using
wearable sensors for cricket. In Proceedings of the 2017 2nd IEEE International Conference on Electrical,
Computer and Communication Technologies, ICECCT 2017, Coimbatore, India, 22–24 February 2017.
Sensors 2019, 19, x FOR PEER REVIEW 3 of 28
42. Guo, Y.W.; Liu, G.Z.; Huang, B.Y.; Zhao, G.R.; Mei, Z.Y.; Wang, L. A pilot study on quantitative analysis
for table tennis block using a 3d accelerometer. In Proceedings of the IEEE/EMBS Region 8 International
Conference on Information Technology Applications in Biomedicine, ITAB, Corfu, Greece, 3–5 November
2010.
43. Jacob, A.; Zakaria, W.N.W.; Tomari, M.R.B.; Sek, T.K.; Suberi, A.A.M. Wearable flex sensor system for
multiple badminton player grip identification. In Advances in Electrical and Electronic Engineering: From
Theory to Applications; AIP Publishing: College Park, Maryland, USA, 2017; Volume 1883.
44. Wood, C.M.; Kipp, K. Use of audio biofeedback to reduce tibial impact accelerations during running. J.
Biomech. 2014, 47, 1739–1741, doi:10.1016/j.jbiomech.2014.03.008.
45. Philpott, L.K.; Weaver, S.; Gordon, D.; Conway, P.P.; West, A.A. Assessing wireless inertia measurement
units for monitoring athletics sprint performance. In Proceedings of the Sensors, Valencia, Spain, 2–5
November 2014; pp. 2199–2202.
46. Kiernan, D.; Hawkins, D.A.; Manoukian, M.A.C.; McKallip, M.; Oelsner, L.; Caskey, C.F.; Coolbaugh, C.L.
Accelerometer-based prediction of running injury in national collegiate athletic association track athletes.
J. Biomech. 2018, 73, 201–209, doi:10.1016/j.jbiomech.2018.04.001.
47. King, R.C.; McIlwraith, D.G.; Lo, B.; Pansiot, J.; McGregor, A.H.; Yang, G.-Z. Body sensor networks for
monitoring rowing technique. In Proceedings of the 2009 6th International Workshop on Wearable and
Implantable Body Sensor Networks, BSN 2009, Berkeley, CA, USA, 3–5 June 2009; pp. 251–255.
48. Makhni, E.C.; Lizzio, V.A.; Meta, F.; Stephens, J.P.; Okoroha, K.R.; Moutzouros, V. Assessment of elbow
torque and other parameters during the pitching motion: Comparison of fastball, curveball, and change-
up. Arthroscopy 2018, 34, 816–822, doi:10.1016/j.arthro.2017.09.045.
49. Lapinski, M.; Berkson, E.; Gill, T.; Reinold, M.; Paradiso, J.A. A distributed wearable, wireless sensor system
for evaluating professional baseball pitchers and batters. In Proceedings of the 2009 International
Symposium on Wearable Computers, ISWC 2009, Linz, Austria, 4–7 September 2009; pp. 131–138.
50. Koda, H.; Sagawa, K.; Kuroshima, K.; Tsukamoto, T.; Urita, K.; Ishibashi, Y. 3d measurement of forearm
and upper arm during throwing motion using body mounted sensor. J. Adv. Mech. Des. Syst. Manuf. 2010,
4, 167–178, doi:10.1299/jamdsm.4.167.
51. Mitsui, T.; Tang, S.; Obana, S. Support system for improving golf swing by using wearable sensors. In
Proceedings of the 2015 Eighth International Conference on Mobile Computing and Ubiquitous
Networking (ICMU), Hakodate, Japan, 20–22 January 2015; pp. 100–101.
52. Shepherd, J.B.; Giblin, G.; Pepping, G.J.; Thiel, D.; Rowlands, D. Development and validation of a single
wrist mounted inertial sensor for biomechanical performance analysis of an elite netball shot. IEEE Sens.
Lett. 2017, 1, doi:10.1109/LSENS.2017.2750695.
53. Taha, Z.; Mat-Jizat, J.A.; Omar, S.F.S.; Suwarganda, E. Correlation between archer’s hands movement while
shooting and its score. Eng. Sport 2016, 147, 145–150.
54. Wang, Y.; Zhao, Y.; Chan, R.H.M.; Li, W.J. Volleyball skill assessment using a single wearable micro inertial
measurement unit at wrist. IEEE Access 2018, 6, 13758–13765, doi:10.1109/ACCESS.2018.2792220.
55. Wang, Z.; Wang, J.; Zhao, H.; Yang, N.; Fortino, G. Canoesense: Monitoring canoe sprint motion using
wearable sensors. In Proceedings of the 2016 IEEE International Conference on Systems, Man, and
Cybernetics, SMC 2016, Budapest, Hungary, 9–12 October 2016; pp. 644–649.
56. Mocera, F.; Aquilino, G.; Somà, A. Nordic walking performance analysis with an integrated monitoring
system. Sensors 2018, 18, 1505.
57. Moher, D.; Liberati, A.; Tetzlaff, J.; Altman, D.G.; The, P.G. Preferred reporting items for systematic reviews
and meta-analyses: The prisma statement. PLoS Med. 2009, 6, e1000097, doi:10.1371/journal.pmed.1000097.
58. Small Wireless Multi-Function Sensor “tsnd121/151”. Available online: https://www.atr-
p.com/products/TSND121.html (accessed on 24 December 2018).
59. X-IMU Our Original Versatile IMU Board. Available online: http://x-io.co.uk/x-imu/ (accessed on 24
December 2018).
60. The Pedar® System—The Quality In-Shoe Dynamic Pressure Measuring System. Available online:
http://novel.de/novelcontent/pedar (accessed on 24 December 2018).
61. G-link®-lxrs® Low-Cost Integrated Accelerometer Node. Available online:
https://www.microstrain.com/wireless/g-link (accessed on 24 December 2018).
62. Wireless Mems Inertial Sensor. Available online:
https://sabelsport.files.wordpress.com/2014/03/sabel_sense_270214a.pdf (accessed on 24 December 2018).
Sensors 2019, 19, x FOR PEER REVIEW 4 of 28
63. User Manual and Specifications. Available online: https://gaitup.com/wp-content/uploads/Physilog-User-
manual_RA.pdf (accessed on 24 December 2018).
64. Research-Grade Wearable Sensors. Available online: https://www.apdm.com/wearable-sensors/ (accessed
on 24 December 2018).
65. Moven User Manual. Available online:
http://cs.unc.edu/Research/stc/FAQs/Xsens/Moven/Moven%20User%20Manual.pdf (accessed on 24
December 2018).
66. Nunome, H.; Ikegami, Y.; Kozakai, R.; Apriantono, T.; Sano, S. Segmental dynamics of soccer instep kicking
with the preferred and non-preferred leg. J. Sports Sci. 2006, 24, 529–541.
67. Byström, A.; Rhodin, M.; Von Peinen, K.; Weishaupt, M.A.; Roepstorff, L. Basic kinematics of the saddle
and rider in high-level dressage horses trotting on a treadmill. Equine Vet. J. 2009, 41, 280–284.
68. Chalmers, D.J. Injury prevention in sport: Not yet part of the game? Inj. Prev. 2002, 8, iv22–iv25,
doi:10.1136/ip.8.suppl_4.iv22.
69. Donaldson, A.; Lloyd, D.G.; Gabbe, B.J.; Cook, J.; Young, W.; White, P.; Finch, C.F. Scientific evidence is
just the starting point: A generalizable process for developing sports injury prevention interventions. J.
Sport Health Sci. 2016, 5, 334–341, doi:10.1016/j.jshs.2016.08.003.
70. Schiff, M.A.; Caine, D.J.; O’Halloran, R. Injury prevention in sports. Am. J. Lifestyle Med. 2010, 4, 42–64,
doi:10.1177/1559827609348446.
71. Cuesta-Vargas, A.I.; Galán-Mercant, A.; Williams, J.M. The use of inertial sensors system for human motion
analysis. Phys. Ther. Rev. 2010, 15, 462–473, doi:10.1179/1743288X11Y.0000000006.
72. Mtw Awinda Wireless 3dof Motion Tracker. Available online: https://shop.xsens.com/shop/xsens-
mvn/mtw-awinda-wireless-3dof-motion-tracker (accessed on 29 January 2019).
73. Physilog®5: Motion Sensor. Available online:
https://shop.gaitup.com/index.php?id_product=1&controller=product (accessed on 29 January 2019).
74. Adxl330 Small, Low Power, 3-axis ±3 g i Mems® Accelerometer Data Sheet (rev. 0). Available online:
https://www.sparkfun.com/datasheets/Components/ADXL330_0.pdf (accessed on 1 January).
75. Single Axis Accelerometer Breakout—ADXL193 (±250 g). Available online: https://www.proto-
pic.co.uk/single-axis-accelerometer-breakout-adxl193-250g.html (accessed on 29 January 2019).
76. Tullos, H.S.; King, J.W. Throwing mechanism in sports. Orthop. Clin. N. Am. 1973, 4, 709–720.
77. Conte, S.; Requa, R.K.; Garrick, J.G. Disability days in major league baseball. Am. J. Sports Med. 2001, 29,
431–436.
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access
article distributed under the terms and conditions of the Creative Commons
Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
... Second, wearable device technology provides athletes with real-time feedback and personalized training plans. By connecting with devices such as smartphones or computers, athletes can obtain real-time training data and sports analysis reports [15][16][17]. These reports can analyze the athlete's posture, movement, strength and other aspects of the problem, and provide personalized recommendations for improvement according to individual circumstances. ...
Article
Full-text available
ActiGraphGT9X was applied to collect the energy consumption of table tennis and establish the multiple regression equations suitable for the prediction of energy consumption in table tennis, so as to enrich the ActiGraph measurement system. Using the K4b2 measurement value as the calibration, accelerometers were worn on the handle of the racket, the outside of the wrist of the racket holder, the outside of the iliopsoas muscle at the waist, the front side of the center of the thigh, and the outside of the ankle (the same limb as that of the racket holder), and accelerometers were used to synchronously monitor the in-situ forehand and backhand strokes, the sideways movement forehand and backhand strokes, the forward movement forehand and backhand strokes, the sideways movement forehand and backhand alternate strokes, and simulated free singles under different ball velocities. Perform monitoring. There was a significant underestimation of EE and MET predictions for GT3X at the waist, thigh and ankle regions, with low agreement with K4b2 measurements, and a significant overestimation of EE and MET predictions for GT3X at the wrist and racket handle regions, with low agreement with K4b2 measurements. The study established two regression equations for predicting energy consumption in tennis, and their predicted values were tested to be not significantly different from the measured values. It is more feasible to use an Actigraph accelerometer to measure physical energy consumption in table tennis.
... Sports biomechanics allows for athletes to learn the technical gestures and for coaches to detect and correct any executive defects [6]. To achieve these goals, the technology is increasingly coming to the aid of scientists and professionals, both for improving performance and for preventing injuries [7][8][9]. In particular, non-invasive instruments, such as the LiDAR technology capable of evaluating the morphology of the spine through a 3D scanning method, have proven to be valid in monitoring the athletes' physical status in order to manage low back pain in athletes [10]. ...
Article
Full-text available
Biomechanics is the application of the principles of mechanics to humans; that is, the study of the motion of bodies and the causes that determine it [...]
... A decisive factor why teams employ GPS over time-motion analysis (captured video recordings of training or matches) or other modalities at present is due to the biases of data interpretation by the user that can affect the reliability and may also be timeconsuming or complicated (Venter et al., 2011). Nevertheless, GPS provides users with objective and trustworthy data in addition to being incredibly portable; more significantly, it is a useful tool since it provides real-time feedback on a variety of variables in many athletes unlike LPS, lidar or optical tracking (Adesida et al., 2019;Hulin et al., 2016). Furthermore, the convenient portability of GPS systems allows for easy data collection anywhere without any infrastructure compared to the fixed nature of timemotion analysis (Hennessy & Jeffreys, 2018). ...
Article
Full-text available
This study assessed the interchangeability of the 10-Hz Polar and Catapult GPS during competitive matches. The agreement between data from both GPS units worn simultaneously and processed with the manufacturer’s individual GPS-filtered software was also assessed. Thirty players competing in the Currie Cup first division competition were monitored using two different tracking systems across six matches. To determine the interchangeability between systems, player movement variables including total distance (TD), low-speed running (LSR, 0.0–14.4 km/h), high-speed running (HSR, 14.4–18.9 km/h), very high-speed running (VHSR, >18.9 km/h), acceleration efforts > 2.5 m/s2 (ACC), deceleration efforts <-2.5 m/s2 (DEC) and maximum velocity reached during each half were compared. The two systems showed good to excellent agreement (CCC = 0.83– 0.98) during all selected variables. During the entire match, Polar had, on average, higher values than Catapult, except for LSR and HSR. The percentage differences between systems were 3.6% TD, 1.9% maximum velocity, −4.7% LSR, −4.6% HSR, 16.5% VHSR, 13.7% ACC and 11.9% DEC. In addition, Bland-Altman plots showed a low average difference for TD (129.1; 90.1 m), maximum velocity (0.5; 0.5 km/ h), LSR (138.2; 80.9 m), HSR (21.3; 5.4 m), VHSR (35.7; 22.3 m), ACC (1.6; 1.8 efforts) and DEC (2.0; 1.2 efforts).
... Söz konusu giyilebilir cihazlar; sporculara, antrenörlere ve meraklılara antrenmanı optimize etmek, performansı artırmak ve hedeflerine ulaşmak için değerli veri bilgileri sağlar. Ayrıca bu cihazların çoğu, zaman içinde derinlemesine analiz ve performans takibi için mobil uygulamalar ve çevrimiçi platformlarla entegrasyon sunar (Adesida, Papi, & McGregor, 2019;Seçkin, Ateş, & Seçkin, 2023). ...
Chapter
Full-text available
PHYSICAL FITNESS CONCEPTS IN TRAINING SCIENCES The fundamental concepts of Sport, Fitness, Physical Activity, Exercise, and Wellness have been thoroughly explained to ensure their correct representation and to build accurate knowledge upon these concepts.
... A decisive factor why teams employ GPS over time-motion analysis (captured video recordings of training or matches) or other modalities at present is due to the biases of data interpretation by the user that can affect the reliability and may also be timeconsuming or complicated (Venter et al., 2011). Nevertheless, GPS provides users with objective and trustworthy data in addition to being incredibly portable; more significantly, it is a useful tool since it provides real-time feedback on a variety of variables in many athletes unlike LPS, lidar or optical tracking (Adesida et al., 2019;Hulin et al., 2016). Furthermore, the convenient portability of GPS systems allows for easy data collection anywhere without any infrastructure compared to the fixed nature of timemotion analysis (Hennessy & Jeffreys, 2018). ...
... A system composed of 17 inertial measurement units (IMUs) (XSENS, Enschede, Netherlands) recorded whole-body kinematics of participants at a sampling rate of 60 Hz. This is an accurate, non-intrusive measurement tool to capture and analyze the kinematic data addressed in this study (pianists' ROM, posture, and distal joint angular jerk) (Adesida et al., 2019;Blair et al., 2018). Sensors were placed on the head, trunk, scapulae, upper-arms, forearms, hands, pelvis, thighs, shanks, and feet according to manufacturer recommendations ( Figure 1). ...
Article
Full-text available
Introduction Expression is a key aspect of music performance. Studies on pianists’ gestures and expression have mainly documented the impact of their expressive intentions on proximal segments and head linear kinematics. It remains unclear how pianists’ expressive intentions influence joint angular kinematics as well as exposure to risk factors of injury, such as poor overall posture and distal jerky movements, two kinematic factors linked to injury. The first objective of this exploratory case study was to analyze the influence of pianists’ expressive intentions on proximal and distal joint range of motion (ROM) across different musical contexts. The second objective was to evaluate the impact of expressive intentions on the posture of joints that are commonly injured in pianists, as well as distal joint angular jerk. Methods: Two expert pianists (P1 and P2) performed six musical excerpts (E1–E6) in two experimental conditions: normal condition (including expressive intentions) and the control condition (strictly playing the composer’s notations written in the score with no subjective interpretation). An inertial measurement unit system recorded upper body kinematics. Methods Two expert pianists (P1 and P2) performed six musical excerpts (E1–E6) in two experimental conditions: normal condition (including expressive intentions) and the control condition (strictly playing the composer’s notations written in the score with no subjective interpretation). An inertial measurement unit system recorded upper body kinematics. Results and discussion Both proximal and distal joint ROM increased when pianists incorporated expressive intentions. Participants exhibited more static, non-neutral wrist postures when incorporating expressive intentions (right and left wrist for P1 and P2, respectively), suggesting an increased risk of distal injury. On the contrary, the thorax exhibited more dynamic, neutral flexion postures, suggesting a reduced risk of proximal injury. These results suggest that expressive intentions may impact proximal and distal postures differently. Incorporating expressive intentions also led to jerkier, less smooth wrist movements in lyrical, non-virtuosic musical excerpts (E1–E4). However, in more virtuosic excerpts (E5–E6), there were generally no differences between conditions. Spatiotemporal constraints might explain these discrepancies between non-virtuosic and virtuosic musical excerpts. These results provide evidence of the impact of expressive intentions on the entire kinematic chain, while highlighting the implications of the subjective dimension of music expression in relation to exposure to risk factors of injury.
... quality. 17 Assigning categories of study quality has been done in previous systematic reviews using the Downs and Black checklist [18][19][20] and was used in the present study. Both authors completed the screening process independently and agreed all scores prior to publication and the full risk of bias table, as well as our modifications to the Downs and Black checklist, can be accessed in online supplemental table 5 . ...
Article
Full-text available
Objectives To summarise the evidence regarding the prevalence of anxiety and depression in former elite athletes compared with the general population. Design Systematic review and meta-analysis. Data sources Five electronic databases (Web of Science, PubMed, MEDLINE, Scopus and SPORTDiscus) were searched from 1970 to 2023. Eligibility criteria Studies were included in the meta-analysis if they: (1) were written in English; (2) included male or female elite athletes that had been retired ≥1 year; (3) included a control group or population reference values; (4) reported the time-point prevalence of anxiety and/or depression; and (5) were of a retrospective, longitudinal or prospective, methodological design. A modified version of the Downs and Black tool was used to determine risk of bias. Results 37 unique studies including 24 732 former athletes (2% female) were included in the meta-analysis. The time-point prevalence of anxiety (prevalence ratio (PR): 2.08 (95% CI 1.57 to 2.60)) and depression (PR: 2.58 (95% CI 2.04 to 3.12)) in former athletes was over twice that of the general population. Subgroup analyses revealed former American football players and jockeys had the highest time-point prevalence of both anxiety and depression (PR: 2.24–2.88), whereas the time-point prevalence of depression and anxiety was not significantly different to the general population for former rugby players (PR: 1.13–1.30). Conclusion Our meta-analyses demonstrated the time-point prevalence of anxiety and depression in former elite athletes could be over twice that of the general population, with sport-specific differences evident. PROSPERO registration number CRD42022347359.
... Furthermore, the distortion of time-series data due to the impact of the foot with the ball also complicates this scenario of contextual factors [40,41]. Indeed, the variability in validity outcomes of the included studies in the present systematic review exposes the complexity of collecting biomechanical data in real-world sports settings [14,30,76]. ...
Article
Full-text available
Kinematic assessment of ball kicking may require significant human effort (e.g., traditional vision-based tracking systems). Wearables offer a potential solution to reduce processing time. This systematic review collated measurement properties (validity, reliability, and/or accuracy) of wearable kinematic-based technology systems used to evaluate soccer kicking. Seven databases were searched for studies published on or before April 2024. The protocol was previously published and followed the PRISMA 2020 statement. The data items included any validity, reliability, and/or accuracy measurements extracted from the selected articles. Twelve articles (1011 participants) were included in the qualitative synthesis, showing generally (92%) moderate methodological quality. The authors claimed validity (e.g., concurrent) in seven of the eight studies found on the topic, reliability in two of three, and accuracy (event detection) in three of three studies. The synthesis method indicated moderate evidence for the concurrent validity of the MPU-9150/ICM-20649 InvenSense and PlayerMaker™ devices. However, limited to no evidence was identified across studies when considering wearable devices/systems, measurement properties, and specific outcome variables. To conclude, there is a knowledge base that may support the implementation of wearables to assess ball kicking in soccer practice, while future research should further evaluate the measurement properties to attempt to reach a strong evidence level.
Article
The emergence of two-dimensional nanomaterials, especially MXene, significantly overcomes the limitations of flexible pressure sensors regarding their sensing abilities, mechanical properties, and electromagnetic shielding effectiveness. This advancement underscores their great potential for use in wearable and medical monitoring devices. However, single-layer MXene is highly prone to oxidation when exposed to air and tends to stack between layers. Combining MXene with other functional materials to create heterojunction structures effectively addresses the stacking problem while also providing the resulting composites with excellent electrical conductivity, mechanical flexibility, and electromagnetic shielding capabilities, which are essential for enhancing sensor performance. This review systematically outlines various microstructural designs and improvement strategies aimed at boosting the sensing efficiency of different flexible pressure sensors based on MXene. It offers a comprehensive analysis of their significance in medical monitoring, anticipates future challenges and opportunities, and serves as an important reference for advancing precision and personalized approaches in medical monitoring.
Article
Teknolojinin hızlı gelişimi, spor yönetimini köklü bir şekilde dönüştürmüştür. Spor organizasyonları ve yöneticileri, bu yeniliklerle uyum sağlayarak iş verimliliklerini artırmakta, veri analizi yapabilmekte ve sporcuların performansını daha etkili bir şekilde izleyebilmektedir. Özellikle giyilebilir teknolojiler, bu ihtiyaçlara karşılık vererek daha akıllı ve etkili stratejilerin geliştirilmesine olanak tanımaktadır. Bu araştırmamızın amacı giyilebilir spor teknolojilerin spor yönetiminde kullanımı ve etkilerinin incelenmesidir. Araştırmada, nitel araştırma metodolojisine odaklanılarak doküman analizi yöntemi tercih edilmiştir. Araştırma sürecinde, öncelikle giyilebilir spor teknolojileri ve spor yönetimi konularıyla ile ilgili akademik makaleler, tezler, dergiler, gazeteler ve kitap dokümanlarına erişilerek orijinallikleri kontrol edilmiştir. Elde edilen veriler detaylı bir şekilde incelenerek giyilebilir spor teknolojilerin spor yönetiminde kullanımı ve etkileri üzerine kapsamlı bir değerlendirme yapılmıştır. Giyilebilir spor teknolojileri, sporcuların fiziksel durumlarını, performans verilerini ve sağlık göstergelerini gerçek zamanlı olarak izlemeye olanak tanımaktadır. Bu veriler, antrenman programlarının kişiselleştirilmesine, yaralanma risklerinin azaltılmasına ve iyileşme süreçlerinin hızlandırılmasına yardımcı olduğu belirlenmiştir. Ayrıca, spor yöneticilerine ve antrenörlere, takım performansını ve oyuncu sağlığını geliştirmek için kapsamlı bilgiler sağladığı tespit edilmiştir. Bununla birlikte, veri güvenliği, cihazların maliyetleri ve kullanıcıların teknolojiye adaptasyon süreci gibi bazı zorluklar da belirlenmiştir. Sonuç olarak, giyilebilir spor teknolojilerinin spor yönetiminde önemli bir rol oynadığı ve bu alanda büyük bir potansiyel taşıdığı görülmektedir. Gelecekte, teknolojik gelişmelerin devam etmesiyle birlikte, giyilebilir teknolojilerin spor yönetiminde daha geniş bir kullanım alanı bulacağı ve bu alandaki yeniliklerin sporun her seviyesinde olumlu etkiler yaratacağı öngörülmektedir.
Article
Full-text available
Objective To determine the accuracy of wrist and arm-worn activity monitors’ estimates of energy expenditure (EE). Data sources SportDISCUS (EBSCOHost), PubMed, MEDLINE (Ovid), PsycINFO (EBSCOHost), Embase (Ovid) and CINAHL (EBSCOHost). Design A random effects meta-analysis was performed to evaluate the difference in EE estimates between activity monitors and criterion measurements. Moderator analyses were conducted to determine the benefit of additional sensors and to compare the accuracy of devices used for research purposes with commercially available devices. Eligibility criteria We included studies validating EE estimates from wrist-worn or arm-worn activity monitors against criterion measures (indirect calorimetry, room calorimeters and doubly labelled water) in healthy adult populations. Results 60 studies (104 effect sizes) were included in the meta-analysis. Devices showed variable accuracy depending on activity type. Large and significant heterogeneity was observed for many devices (I² >75%). Combining heart rate or heat sensing technology with accelerometry decreased the error in most activity types. Research-grade devices were statistically more accurate for comparisons of total EE but less accurate than commercial devices during ambulatory activity and sedentary tasks. Conclusions EE estimates from wrist and arm-worn devices differ in accuracy depending on activity type. Addition of physiological sensors improves estimates of EE, and research-grade devices are superior for total EE. These data highlight the need to improve estimates of EE from wearable devices, and one way this can be achieved is with the addition of heart rate to accelerometry. PROSPEROregistration number CRD42018085016.
Article
Full-text available
There is a growing interest in Nordic walking both from the fitness and medical point of views due to its possible therapeutic applications. The proper execution of the technique is an essential requirement to maximize the benefits of this practice. This is the reason why a monitoring system for outdoor Nordic walking activity was developed. Using data obtained from synchronized sensors, it is possible to have a complete overview of the users’ movements. The system described in this paper is able to measure: the pole angle during the pushing phase, the arms cycle frequency and synchronization and the pushing force applied to the ground. Furthermore, data from a GPS module give an image of the environment where the activity session takes place, in terms of the distance, slope, as well as the ground typology. A heart rate sensor is used to monitor the effort of the user through his/her Beats Per Minute (BPM). In this work, the developed monitoring system is presented, explaining how to use the gathered data to obtain the main feedback parameters for Nordic walking performance analysis. The comparison between left and right arm measurements allowed validating the system as a tool for technique evaluation. Finally, a procedure to estimate the peak pushing force from acceleration measurements is proposed.
Article
Full-text available
Objective: Sport research often requires human motion capture of an athlete. It can, however, be labour-intensive and difficult to select the right system, while manufacturers report on specifications which are determined in set-ups that largely differ from sport research in terms of volume, environment and motion. The aim of this review is to assist researchers in the selection of a suitable motion capture system for their experimental set-up for sport applications. An open online platform is initiated, to support (sport)researchers in the selection of a system and to enable them to contribute and update the overview. Design: systematic review; Method: Electronic searches in Scopus, Web of Science and Google Scholar were performed, and the reference lists of the screened articles were scrutinised to determine human motion capture systems used in academically published studies on sport analysis. Results: An overview of 17 human motion capture systems is provided, reporting the general specifications given by the manufacturer (weight and size of the sensors, maximum capture volume, environmental feasibilities), and calibration specifications as determined in peer-reviewed studies. The accuracy of each system is plotted against the measurement range. Conclusion: The overview and chart can assist researchers in the selection of a suitable measurement system. To increase the robustness of the database and to keep up with technological developments, we encourage researchers to perform an accuracy test prior to their experiment and to add to the chart and the system overview (online, open access).
Article
Full-text available
Although it is becoming increasingly popular to monitor parameters related to training, recovery, and health with wearable sensor technology (wearables), scientific evaluation of the reliability, sensitivity, and validity of such data is limited and, where available, has involved a wide variety of approaches. To improve the trustworthiness of data collected by wearables and facilitate comparisons, we have outlined recommendations for standardized evaluation. We discuss the wearable devices themselves, as well as experimental and statistical considerations. Adherence to these recommendations should be beneficial not only for the individual, but also for regulatory organizations and insurance companies.
Article
Full-text available
Recent technological developments have led to the production of inexpensive, non-invasive, miniature magneto-inertial sensors, ideal for obtaining sport performance measures during training or competition. This systematic review evaluates current evidence and the future potential of their use in sport performance evaluation. Articles published in English (April 2017) were searched in Web-of-Science, Scopus, Pubmed, and Sport-Discus databases. A keyword search of titles, abstracts and keywords which included studies using accelerometers, gyroscopes and/or magnetometers to analyse sport motor-tasks performed by athletes (excluding risk of injury, physical activity, and energy expenditure) resulted in 2040 papers. Papers and reference list screening led to the selection of 286 studies and 23 reviews. Information on sport, motor-tasks, participants, device characteristics, sensor position and fixing, experimental setting and performance indicators was extracted. The selected papers dealt with motor capacity assessment (51 papers), technique analysis (163), activity classification (19), and physical demands assessment (61). Focus was placed mainly on elite and sub-elite athletes (59%) performing their sport in-field during training (62%) and competition (7%). Measuring movement outdoors created opportunities in winter sports (8%), water sports (16%), team sports (25%), and other outdoor activities (27%). Indications on the reliability of sensor-based performance indicators are provided, together with critical considerations and future trends.
Article
Full-text available
Wearable physical activity trackers are a popular and useful method to collect biometric information at rest and during exercise. The purpose of this systematic review was to summarize recent findings of wearable devices for biometric information related to steps, heart rate, and caloric expenditure for several devices that hold a large portion of the market share. Searches were conducted in both PubMed and SPORTdiscus. Filters included: humans, within the last 5 years, English, full-text, and adult 19+ years. Manuscripts were retained if they included an exercise component of 5-min or greater and had 20 or more participants. A total of 10 articles were retained for this review. Overall, wearable devices tend to underestimate energy expenditure compared to criterion laboratory measures, however at higher intensities of activity energy expenditure is underestimated. All wrist and forearm devices had a tendency to underestimate heart rate, and this error was generally greater at higher exercise intensities and those that included greater arm movement. Heart rate measurement was also typically better at rest and while exercising on a cycle ergometer compared to exercise on a treadmill or elliptical machine. Step count was underestimated at slower walking speeds and in free-living conditions, but improved accuracy at faster speeds. The majority of the studies reviewed in the present manuscript employed different methods to assess validity and reliability of wearable technology, making it difficult to compare devices. Standardized protocols would provide guidance for researchers to evaluate research-grade devices as well as commercial devices used by the lay public.
Article
Full-text available
In this study, a wearable sensing device (WSD) based on MEMS (microelectromechanical systems) motion sensors (an inertial measurement unit consisting of sensors with 3 axes of acceleration and 3 axes of angular rate) was built to assess the skill levels of volleyball spikers. The WSD developed is inexpensive and requires much less computational power than conventional videography analysis in monitoring motions of volleyball players during spikes. This paper presents the hardware and software design and the data processing algorithms used in the system. Six right-handed male subjects wore the WSD on their wrists and performed 120 spiking trials in a volleyball court. Skill of the volleyball spikers was accessed by classifying them into three different levels from the recorded data with support vector machine (SVM). The results demonstrate that this system is capable of assessing the difference between elite, sub-elite and amateur volleyball players with an average accuracy of 94%. The proposed method can be extended to analyze the skill levels of players in other sports where wrist actions are important (e.g., basketball, badminton, and baseball).
Article
How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies - Volume 77 Issue OCE4 - R. O'Driscoll, J. Turicchi, S. Scott, K. Beaulieu, J. Matu, K. Deighton, G. Finlayson, R.J. Stubbs
Article
Running-related injuries (RRI) may result from accumulated microtrauma caused by combinations of high load magnitudes (vertical ground reaction forces; vGRFs) and numbers (strides). Yet relationships between vGRF and RRI remain unclear – potentially because previous research has largely been constrained to collecting vGRFs in laboratory settings and ignoring relationships between RRI and stride number. In this preliminary proof-of-concept study, we addressed these constraints: Over a 60-day period, each time collegiate athletes (n = 9) ran they wore a hip-mounted activity monitor that collected accelerations throughout the entire run. Accelerations were used to estimate peak vGRF, number of strides, and weighted cumulative loading (sum of peak vGRFs weighted to the 9th power) across the entirety of each run. Runners also reported their post-training pain/fatigue and any RRI that prevented training. Across 419 runs and > 2.1 million strides, injured (n = 3) and uninjured (n = 6) participants did not report significantly different pain/fatigue (p = 0.56) or mean number of strides per run (p = 0.91). Injured participants did, however, have significantly greater peak vGRFs (p = 0.01) and weighted cumulative loading per run (p < 0.01). Results from this small but extensively studied sample of elite runners demonstrate that loading profiles (load magnitude-number combinations) quantified with activity monitors can provide valuable information that may prove essential for: (1) testing hypotheses regarding overuse injury mechanisms, (2) developing injury-prediction models, and (3) designing and adjusting athlete- and loading-specific training programs and feedback.
Article
Wearable inertial measurement systems (IMS) allow for three-dimensional analysis of human movements in a sport-specific setting. This study examined the concurrent validity of a IMS (Xsens MVN system) for measuring lower extremity and pelvis kinematics in comparison to a Vicon motion analysis system (MAS) during kicking. Thirty footballers from Australian football (n=10), soccer (n=10), rugby league and rugby union (n=10) clubs completed 20 kicks across four conditions. Concurrent validity was assessed using a linear mixed-modelling approach, which allowed the partition of between and within-subject variance from the device measurement error. Results were expressed in raw and standardised units for assessments of differences in means and measurement error, and interpreted via non-clinical magnitude-based inferences. Trivial to small differences were found in linear velocities (foot and pelvis), angular velocities (knee, shank and thigh), sagittal joint (knee and hip) and segment angle (shank and pelvis) means (mean difference: 0.2–5.8%) between the IMS and MAS in Australian football, soccer and the rugby codes. Trivial to small measurement errors (from 0.1 to 5.8%) were found between the IMS and MAS in all kinematic parameters. The IMS demonstrated acceptable levels of concurrent validity compared to a MAS when measuring kicking biomechanics across the four football codes. Wearable IMS offers various benefits over MAS, such as, out-of-laboratory testing, larger measurement range and quick data output, to help improve the ecological validity of biomechanical testing and the timing of feedback. The results advocate the use of IMS to quantify biomechanics of high-velocity movements in sport-specific settings.