Cyclic Load Behaviour of Beam-to-Column Glulam Joints Combining Glued-in Rods with Steel Brackets

Authors:
To read the full-text of this research, you can request a copy directly from the authors.

Abstract

This paper presents an experimental campaign conducted on the beam-to-column glulam joints combing glued-in rods and steel brackets (BCGS glulam joints) aiming to investigate the mechanical behaviour of these glulam joints under low cyclic loading. Three types of steel brackets were designed for connecting the beam and column combing with glued-in rods and to work as energy dissipaters. In each group of specimens (except for group MJ4), two specimens were tested under monotonic loading and the others were subjected to low cyclic loading. The test results were summarized comprehensively in terms of failure modes, joint stiffness, hysteresis loops, ductility and energy dissipation ability. Generally, the difference of load capacity between BCGS glulam joints and the beam-to-column glulam joints only with glued-in rods (BCG glulam joints) was not significant. The joint stiffness of BCG glulam joints was higher than that of the BCGS glulam joints, while the stiffness degradation of the later is slower than the former. The hysteresis loops of the BCGS glulam joints exhibited less pinching effect obviously compared with the BCG glulam joints, which indicated that the energy dissipation ability of the glulam joints with glued-in rods could be improved significantly by using the steel brackets as energy dissipaters. Moreover, it should be noted that the hysteresis loops of groups CJ1 showed slipping effect obviously during testing. This might due to the insufficient shear resistance of these two groups, so that further investigations on BCG glulam joints with shear-resisting components are urgently needed.

No full-text available

Request Full-text Paper PDF

To read the full-text of this research,
you can request a copy directly from the authors.

ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
This study aims to develop an improved understanding of the interfacial bond behavior of softwood glulam joints with bonded-in threaded steel rod. A total of 39 glulam joints with bonded-in single-threaded steel rods were tested to failure in the pull-pull configuration. The test results were presented in term of failure modes, load-relative movement response, pullout strength, and the corresponding slip. The distributions of bonded-in rod axial strain, interfacial bond stress, and relative movement were also analyzed to evaluate the local bond stress-relative movement response in the bond line. The results confirmed that the bond-relative movement response is dependent on the locations along the anchorage length, and the bond-relative movement responses located near both the loaded end and the anchorage end were observed to be stiffer than those at other locations. Finally, the predictions for the load capacity of the glulam joints with bonded-in threaded steel rod were carried out based on several existing empirical formulas.
Article
Full-text available
This paper presents an experimental programme conducted to investigate the structural capacity of bonded-in steel bars loaded parallel to the grain in standard straight elements of natural timber. Tensile pull-out tests were conducted to examine the effect of bar diameter, bonded length and bar type (deformed and threaded steel bars) on the structural capacity of the connection. Pull-out tests on timber blocks in which the bars were deliberately misaligned in the holes were also tested to account for the fact that in real situations bars may not be perfectly centralised in the holes. The pull-out test results showed that bar diameter, bonded length and bar type considerably affected the structural capacities of the bonded-in steel joints. The results were compared with some established design equations.
Article
Full-text available
The use of glued-in rods is a very efficient technique for connecting timber elements either in restoration or in the construction of new structures. It has been used for about 30 years in several countries all over the world. However, despite multiple research efforts, there is still a lack of consensus on a standard method to design such connections and to compute their carrying capacity. If a company wishes to include this system in its design possibilities, it has to validate it by testing. This paper reports on the results of a test program aiming at situating the glued-in rod connecting technique of the Belgian glulam company Lamcol with the main existing design methods. A total of 60 specimens of glued-in rod joints were tested in pull-pull configuration. The varying parameters were the anchoring length and the rod diameter. The rods were threaded steel bars. They were bonded into glulam Norway spruce lamellas parallel to the grain by means of an epoxy-type adhesive injection. The preparation of the specimens was kept very simple, as close as possible to the actual production technique of the company. The main difference with previously reported test results comes from the failure modes. Failure occurred mainly by splitting of the wood element along the anchorage although the standard recommendations for the distance between the rods and the edges of the specimens were respected. Two strength models are derived empirically from the analysis of the test results which are also compared with predictions from computation methods proposed in the literature.
Article
The advances of timber engineering in the field of tall buildings raised a need for high performance connections that can accommodate increased demands due to higher loads and longer spans. A semi-rigid connection with glued-in rods was designed to fulfill these requirements. Moment-rotation behavior of this connection was investigated in a series of quasi-static cyclic tests. A moment-resisting connection was established between timber columns and steel base plates. Three different timber products, including hardwood and softwood species, and two different rod diameters were used. The columns were subjected to shear force and bending, to simulate the loading conditions of a column in a frame under lateral loads. The tests were performed with increasing rotation demand on the column until the failure.
Article
Connections for timber structures using concealed bonded-in rods offer one possible solution to the development of more efficient joining methods. However the importance of certain basic joint characteristics, and the influence of adhesive type and properties, are not yet fully understood and as such design criteria are lacking. This paper describes a comprehensive experimental and numerical investigation into the fundamental material and joint geometry characteristics of rods bonded in to timber. The adhesive type and performance are both considered, along with test configuration and joint parameters that included rod embedment length, rod diameter, annular bondline thickness, multiple rods and rod spacing. A navel approach that involved end-profiling of the bond area was also investigated. It was found that epoxy adhesives out-performed all other types investigated, and pull-out strengths can be significantly improved through careful selection and optimisation of the joint geometry.
Glulam Connections Using Epoxy Glued-in Rebars. The University of British Columbia
  • R Wiktor
Wiktor R. Glulam Connections Using Epoxy Glued-in Rebars. The University of British Columbia, 1994.