PROCEEDINGS OF ECOS 2017 - THE 30TH INTERNATIONAL CONFERENCE ON
EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS
JULY 2-JULY 6, 2016, SAN DIEGO, CALIFORNIA, USA
1
Effects of void fraction and heat transfer
correlations in a charge-sensitive ORC model – a
comparison with experimental data
Rémi Dickes*, Ludovic Guillaume, Olivier Dumont,
Sylvain Quoilin and Vincent Lemort
Energy System Research Unit - Thermodynamics Laboratory
Department of Mechanical and Aerospace Engineering - Faculty of Applied Sciences
University of Liège
Belgium
* Corresponding author: rdickes@ulg.ac.be
Abstract:
In order to properly evaluate the off-design performance of an ORC unit, it is important to use simulation tools
that minimize the number of assumptions regarding the system state. To avoid imposing the condenser
subcooling (or any other equivalent state variable), the ORC model should account for the mass repartition of
working fluid through the unit in function of the operating conditions. Among the various components
constituting ORC power systems, the proper modelling of the mass of working fluid enclosed in the heat
exchangers is of primary importance. The goal of this work is to develop such a reliable charge-sensitive ORC
model. To this end, a 2kWe recuperative ORC system is used as case study and experimental measurements
are used as reference dataset. The ORC system features two brazed plate heat exchangers and one fin coil
condenser. For these three heat exchangers, a large set of empirical correlations is investigated in order to
evaluate both the fluids void fractions and their convective heat transfer coefficients. By comparing the models
predictions with the experimental data, the study highlights the limitations of existing correlations and
investigates three different correction methods to improve them. Ultimately, the analysis compares nine models
of brazed plate heat exchangers, two models of condenser, three correction methods for improving the heat
transfer correlations and four void fraction methods. Accounting for every combination possible, 288 different
models of the ORC are compared for predicting both the heat exchangers thermal performance and the total
mass enclosed in the ORC unit. Out of this study, the best modelling approach is identified and details of its
charge inventory predictions are presented.
Keywords:
ORC, off-design, charge-sensitive, heat transfer, void fraction, correlations
1. Introduction
A common aspect of ORC power systems is the versatile nature of their operating conditions.
Whether for solar, geothermal or waste heat recovery applications, the heat source (and even
sometimes the heat sink) conditions may fluctuate in time, which imposes the system to adapt its
working regime for performance or safety reasons. Therefore, once sized and built, an ORC engine
is often led to operate in off-design conditions. To properly evaluate the performance of such ORC
systems in off-design conditions, reliable and validated simulation tools must be used. In order to best
replicate the physics of the engine, these models should avoid any user-defined assumption in the
system operation (e.g. an imposed sub-cooling, super-heating, condensing pressure, etc.) and the
ORC performance should be derived from its boundary conditions only (i.e. the heat source and heat
sink supply conditions, the mechanical components rotational speed, the heat exchanger surface area,
etc.). In order to reach such modelling level, the ORC model must be charge-sensitive i.e. to account
for the mass repartition of working fluid through the system in function of the operating conditions
[1]. Among the various components composing an ORC system, it is crucial to properly estimate the
mass enclosed in the heat exchangers because of their relatively high internal volume. Unlike in steam
2
power plants or higher-capacity systems, small-scale ORC units often use a single once-through heat
exchanger to perform the complete heating (or cooling) , including phase change, of the working
fluid. Consequently, several phases of fluid coexist in a same component (i.e. liquid, two-phase and
vapour) and the heat exchanger is divided in multiple zones. The mass of working fluid enclosed in
a heat exchanger of volume can be computed as the sum of the masses included in each of the
N sub-zones, i.e.
( 1 )
where is the volume fraction occupied by the ith zone in the heat exchanger and is the
corresponding mean density of the fluid. Based on this equation, it appears that a reliable charge-
sensitive ORC model implies two main conditions:
1) A proper knowledge of the volume fraction occupied by each zone of fluid in the different
heat exchangers. This spatial division is directly affected by the convective heat transfer
coefficients used to simulate the heat exchangers.
2) A proper evaluation of the fluid density along the heat exchangers. In the case of single-phase
zones, the density calculation is straightforward and can be determined from the fluid
thermodynamic state. In the case of a two-phase flow, however, the density is not only
function of the fluid pressure, temperature and quality, but it also depends on the void fraction
characterizing the flow. Therefore, the density calculation is directly impacted by the void
fraction model used to characterize the boiling or condensing processes.
As demonstrated latter in the text, many different correlations may be found in the scientific literature
to evaluate these void fractions and convective heat transfer coefficients. However, most of these
correlations are derived empirically, based on limited experimental data and their reliability for
extrapolated conditions is not ensured.
The goal of this work is to investigate different correlations of heat transfer coefficient and void
fraction to model the heat exchangers in a charge-sensitive ORC model. To this end, a 2kWe ORC
unit is used as case study. The reliability of the correlations is evaluated by confronting the
simulations results to experimental measurements, both in terms of thermal performance and charge
inventory predictions. The steady-state simulations are performed in Matlab and the heat exchangers
are modelled so as to compute the heat transfer based on the fluids supply conditions only. The model
is of type “moving-boundary” (see [[2], [3]] for further information) and the effective heat transfer in
the heat exchanger is calculated to match the total surface area occupied by the N different zones with
the geometrical surface area of the component i.e.
( 2 )
The heat exchanger model developed for this work is open-source and can be found in the ORCmKit
library [4]. The paper is structured as follows: firstly, in section 2, the test rig used as case study and
the reference dataset is described. In section 3, the thermal performance obtained with the various
heat transfer correlations is assessed. This analysis highlights the limitations of the original
correlations and three correction methods are proposed for improving them. Finally, in section 4, the
effects of the void fraction models are evaluated when computing the total mass enclosed in the ORC
system. In total, 288 different simulations are performed. Out of this analysis, the best modelling
approach is identified and details of its charge inventory predictions are presented. It is worthwhile
to note that similar analyses exist for HVAC systems ([5]–[7]), however, to the best of the authors
knowledge, such study has never been presented for a ORC power unit.
3
2. Experimental set up and dataset
The system investigated as case study is the Sun2Power ORC unit developed by the University of
Liège [8]. It is a 2kWe recuperative ORC system using R245fa as working fluid and built to be
operated with solar collectors (although the experimental data presented in this paper are gathered
using an electrical boiler as heat source). The system consists of three heat exchangers, a diaphragm
pump, a scroll expander and a liquid receiver. Both the recuperator and the evaporator are thermally-
insulated brazed plate heat exchangers while an air-cooled fin coil heat exchanger is used for the
condenser. The system features three control variables: the pump and the fan condenser rotational
speeds (controlled with a variable frequency drive) and the expander rotational speed (controlled by
adjusting the electrical load). As depicted in Figure 1, the system is also instrumented with
thermocouples, flow meters, power meters and pressure sensors in order to properly measure the
performance of the complete test rig and of each subcomponent individually. Although it would have
been interesting to measure the working fluid mass repartition through the system, the ORC test rig
does not feature individual scales under each component. However, the total charge of R245fa
enclosed in the system is known to be 26kg (± 0.5 kg).
Figure 1. Scheme of the Sun2Power ORC test rig
Using this test rig, an experimental campaign is performed and a set of 40 steady-state points are
gathered as reference dataset. These reference points are obtained by averaging the experimental
measurements over 5-minute periods in stabilized regimes and by the application of a data post-
treatment. For further details regarding this reference dataset and the reconciliation method applied
to the raw measurements, please refer to [1]. As a summary, the ranges of operating conditions
covered by the reference dataset are given in Table 1.
Table 1. Operating ranges of the reference dataset
Variable
Min
Max
Unit
Working fluid mass flow rate
16
70
g/s
Heat source mass flow rate
910
990
g/s
Heat source supply temperature
88
120
°C
Heat sink mass flow rate
0.149
1.45
kg/s
Heat sink supply temperature
17
25
°C
Evaporating pressure
6.5
14.4
bar abs.
Condensing pressure
1.6
6.6
bar abs.
Net power output
23
1170
W
Net thermal efficiency
0.5
8
%
4
3. Heat transfer correlations analysis
As presented in the previous section, the ORC system features two types of heat exchangers, namely
an air-cooled fin coil condenser and two brazed plate heat exchangers (BPHEXs). In order to simulate
their thermal performance and to properly evaluate the volume occupied by each zone of fluid, it is
important to use reliable correlations for calculating the fluids convective heat transfer coefficients.
For both technologies, many different correlations may be found in the scientific literature (e.g. see
[9]–[11] for the BPHEXs and [12] for the fin coil condenser). These correlations generally evaluate
the Nusselt number as a function of the flow conditions, the fluids properties and some geometrical
parameters of the heat exchanger. In most cases, these correlations are purely empirical and calibrated
to fit some experimental data. Because there is not one unique reference correlation for characterizing
these heat exchangers, several candidates (among the most common employed nowadays) are tested
for modelling both types of technologies. More specifically, nine different correlations are
investigated to characterize the brazed plate heat exchangers, i.e.:
- 3 correlations for single-phase flows in both the recuperator and the evaporator, respectively
the correlations proposed by Martin [13], Wanniarachchi [14] and Thonon [9]. It must be
noted that the same single-phase correlation is applied for both the hot and cold fluid.
- 3 correlations for the boiling flow in the evaporator, i.e. the correlations proposed by Amalfi
et al. [15], Han et al. [16] and Cooper [17].
- 3 correlations for the condensing flow in the recuperator, namely the correlations proposed by
Longo et al. [18], Han et al. [19] and Shah [20].
Regarding the air-cooled condenser, the following correlations are tested:
- 1 general correlation proposed by Gnielinski [21] for the single-phase flow of working fluid
in horizontal tubes.
- 1 general correlation proposed by Cavallini et al. [22] for the condensing flow of working
fluid in the condenser tubes.
- 2 correlations for the air flow across the coil, i.e. the empirical laws proposed in [21] and the
one proposed by Wang et al. [23].
Fewer correlations are tested for the condenser because of the better characterized flow occurring in
the horizontal tubes. For the sake of conciseness, the equations constituting the heat transfer
correlations are not presented in the current paper, but they may be found in the corresponding
references. Because of the multiple zones coexisting in the heat exchangers, correlations must be
coupled to simulate the components. Since the single-phase and two-phase correlations are, a priori,
independent to each other, any combination between them is possible. As shown in Table 2, it results
nine different models for the brazed plate heat exchangers (i.e. the evaporator and the recuperator),
and two models for the condenser. In order to assess their reliability, the different models presented
in Table 2 are evaluated in the exact same conditions as in the reference dataset and the heat transfer
predicted by each model is confronted to the experimental observations.
In the case of the condenser, the two models investigated (i.e. the models CDA and CDB in Table 2)
demonstrate fairly good agreement with the experimental data. As shown in Figure 2a, both models
properly predict the heat transfer and the modelling deviations are smaller than 10% (on average, the
relative errors are 2.6% and 1.9% for the models CDA and CDB respectively). Regarding the brazed
plate heat exchangers, the modelling performance of the different correlations is much poorer. For
both the recuperator and the evaporator, it appears that all the models, in every case, highly
overpredict the heat transfer in the BPHEXs. In the case of the recuperator, as depicted in Figure 2b,
the heat transfer is overpredicted by 40% on average and similar results are observed for the
evaporator.
5
Table 2: Heat exchangers models investigated for the evaporator, the recuperator and the condenser (NB:
1Han’s boiling correlation [16]; 2Han’s condensation correlation [19])
Evaporator models
(correlations for single-phase & boiling flows in BPHEX)
EVA :
Martin + Almalfi
EVD :
Martin + Han (1)
EVG :
Martin + Cooper
EVB :
Wanniarachchi + Almalfi
EVE :
Wanniarachchi + Han (1)
EVH :
Wanniarachchi + Cooper
EVC :
Thonon + Almalfi
EVF :
Thonon + Han (1)
EVI :
Thonon + Cooper
Recuperator models
(correlations for single-phase & condensing flows in BPHEX)
RECA :
Martin + Longo
RECD :
Martin + Han (2)
RECG :
Martin + Shah
RECB :
Wanniarachchi + Longo
RECE :
Wanniarachchi + Han (2)
RECH :
Wanniarachchi + Shah
RECC :
Thonon + Longo
RECF :
Thonon + Han (2)
RECI :
Thonon + Shah
Condenser models
(correlations for single-phase & condensing flows in tubes + air flow through the coil)
CDA:
Gnielinski + Cavallini + VDI
CDB:
Gnielinski + Cavallini + Wang
These large deviations may be explained by different reasons. Firstly, the single-phase correlations
are all empirically determined using water as heat transfer fluid and their extrapolability to organic
fluids is not verified. Secondly, even though the two-phase correlations are developed with
refrigerants (or other organic fluids), the operating conditions used to calibrated them are more typical
of refrigeration systems than those encountered in ORC systems. In the case of condensing flows, the
saturation temperatures in the two technologies (ORC and HVAC) are of the same order (20°C to
50°C). However, the evaporating temperature in HVAC systems is much smaller than in ORC power
units (-10°C/ 20°C vs. 80°C/150°C) and the validity of the correlations to characterize boiling flows
in ORC systems is not guaranteed. Finally, the correlations employed require a good knowledge of
the BPHEX geometry (i.e. the chevron angle, the plate thickness, the enlargement factor, the
corrugation pattern, etc.). Although some characteristics may be retrieved indirectly from the heat
exchanger datasheet, uncertainties remain and these may alter the proper predictions of the
correlations.
Figure 2. Heat transfer predictions (a) in the condenser (b) in the recuperator
(a)
(b)
6
Based on these results, it appears that the correlations investigated in this work should not be used
directly to simulate the ORC system and its heat exchangers (especially for the BPHEXs). It is
therefore proposed to modify these correlations in order to better fit the experimental measurements.
To this end, three correction methods are investigated for all the models presented in Table 2:
Correction #1: only the most influential correlation in the heat exchanger (i.e. the one referring
to the highest thermal resistivity) is scaled by means of a single factor, i.e.
( 3 )
Correction #2: idem as correction #1, except that all the correlations in the heat exchanger are
corrected with independent factors , i.e.
( 4 )
Therefore, two (resp. three) correction factors are used for correcting each BPHEX (resp.
condenser) model.
Correction #3: idem as correction #2, except that, additionally, the empirical exponents on the
Reynolds number are also scaled by factors , i.e.
( 5 )
In total, four (resp. six) correction factors are used for modifying each BPHEX (resp.
condenser) model.
For each model proposed in Table 2, the correction factors are tuned by minimizing the residuals
between the model predictions and the experimental data. More specifically, the following objective
function F is optimized by means of an interior-point algorithm [24], i.e.
( 6 )
where the first term is referring to the Normalized Root Mean Square Error (as defined in (7)), the
second term accounts for the correction applied to the correlations (aimed to be minimized as well)
and is a weighting factor (set to 0.95 in this work).
( 7 )
In order to compare the effect of the different correction methods, averaged values of the NRMSE
related to each modelling approach are given in Figure 3. As expected, the larger the modifications
applied to the correlations, the better the fitting of the experimental data. The effect of each correction
method on the individual models is detailed in the next section (Figure 4).
Figure 3. Average values of the NRMSE for the heat exchangers in function of the correction method applied
to the correlations
7
4. Void fraction correlations analysis
As mentioned in the introduction, the density of a flowing two-phase mixture is not function of its
thermodynamic state only, but it also depends on the spatial fraction occupied by the liquid and
vapour phases. To account for this effect, the flow can be characterized by the void fraction α, defined
as:
( 8 )
where Av and Atot are respectively the vapour flow and the total flow cross-sectional areas, x is the
fluid quality, ρv and ρl are the saturated vapour and saturated liquid densities, and S is the slip
(velocity) ratio between the vapour phase and the liquid phase. Based on the void fraction α, the mass
Mtp enclosed in a two-phase zone of length L and of cross section area A can be calculated by
( 9 )
As for the heat transfer coefficients, several correlations may be found in the scientific literature to
characterize the void fraction in function of the flow operating conditions. In this work, four of the
most common void fraction models are considered, namely:
- The homogenous model, which assumes a slip-ratio S equal to 1;
- The model proposed by Zivi [25], which computes the slip-ratio such as
;
- The model proposed by Lockhart-Martinelli [26], which calculates α as an empirical function
of the parameter Xtt (see the reference paper for further details);
- The empirical mass-flux-dependent model proposed by Hughmark [27].
By using these four void fraction models, the total mass of working fluid enclosed in the ORC system
is computed over the whole dataset (40 points in total) and compared to the experimental charge. The
total charge of R245fa is calculated as the sum of the masses enclosed in the various components of
the ORC system, i.e.
( 10 )
To numerically quantify the reliability of the mass prediction, both the mass mean value (i.e. the
average mass computed over the 40 experimental points) and the mass standard deviation (to illustrate
the mass scattering) are computed for the different modelling approaches. Because there are two
models of the condenser, nine models for the BPHEXs and 4 correction methods, all independent
from each other, 72 different models of the ORC system are built (i.e. all the combinations possible
are evaluated). For each of these 72 ORC models, the four void fraction methods are used to compute
the total mass of working fluid.
Ultimately, 288 charge-sensitive simulations are performed and the results are given in Figure 4. In
this figure, to each abscissa position corresponds a unique combination of BPHEX model, condenser
model and correction method (refer to the legends for better clarity). The three top subplots illustrate
the residuals (NRMSE as defined in (7)) related to the heat transfer prediction for each heat exchanger
(in comparison to the experimental data). The fourth subplot depicts the mean mass value computed
for the total system over the 40 reference points (aimed to be close to the experimental charge of 26
± 0.5kg). Finally, the last subplot depicts the standard deviation while evaluating the mass over the
40 reference experimental points (aimed to be as low as possible).
8
Figure 4. Global results of the comparative study for the ORC system in terms of heat transfer and charge inventory predictions. Each abscise (from 1 to 72) is
referring to a single ORC model, i.e. a unique combination of BPHEX model (EVA/RECA
EVI/RECI), condenser model (CDA or CDB) and correction method
(original correlation or with correction #1 to #3). The 3 top subplots depict the NRMSE committed on the heat transfer prediction of each heat exchangers. The
4thsubplot depicts the mean total mass predicted over the 40 experimental points. The 5th plot illustrates the standard deviation in the mass prediction over the
dataset.
9
Based on this figure, the following elements can be highlighted:
- Regarding the condenser, the model CDB shows a slightly better thermal performance (i.e. it
better fits the experimental data in terms of heat transferred in the condenser), but it induces
larger scattering in the global mass calculation (i.e. larger standard deviations of MORC)
whatever the correction method employed.
- In all situations, the homogenous and the Hughmark’s void fraction models lead to the lowest
and the highest mass estimations, respectively. On average, the difference between their total
mass predictions is 2.54kg. On the other hand, the void fraction proposed by Zivi and
Lockhart-Martinelli computes similar intermediate charge inventories (generally closer to the
predictions of the homogenous model). Whatever the correction method and the heat transfer
correlations employed, Hughmark’s void fraction model (which accounts for the influence of
the fluid mass flux) appears to be the best modelling approach to assess the global charge of
refrigerant in the system. In every case, it leads to the lowest error in the prediction of the
charge and to the lowest standard deviation.
- The mass standard deviation is not much influenced by the void fraction model, but rather by
the correction methods applied to the heat transfer correlations. As shown in the previous
section, the larger the modifications applied to the correlations, the better the fitting of the
heat power transferred in the heat exchangers. However, from Figure 4 it can be seen that the
larger the modifications applied to the correlations, the wider the scattering in the mass
predictions. By altering the heat transfer correlations, the thermal performance of the heat
exchanger models is improved but the charge inventory is deteriorated. Furthermore, the
correction method also influences the mean mass prediction over the entire dataset. According
to this analysis, the most suited correction method to be applied to the heat transfer
correlations is the method #1. By only scaling one heat transfer correlation, this correction
method offers the best trade-off between:
o improving the heat exchangers models thermal predictions;
o estimating the global charge of working fluid in the system both in terms of good mean
mass value and low mass prediction scattering.
From these results, the best modelling approach to perform a charge-sensitive simulation of the
system appears to be the ORC model #19 (i.e. the models EVA + RECA + CDA, all modified by means
of the correction method #1) using Hughmark’s void fraction model. The detailed charge inventory
predicted by this model for the 40 points of the reference dataset is depicted in Figure 5. As can be
seen, the mass mean value (25.12kg) fits well the experimental charge enclosed in the ORC system
(26±0.5kg). The scattering of the global mass prediction is fairly limited, with a standard deviation
of 1.71kg. The deviation observed from the experimental charge is maximum 13.5% (MORC,max = 29.5
kg) and drops to 6.2% on average. According to the simulations, the largest part of the fluid is found
in the condenser, the liquid receiver and then the evaporator. Without any weight measurements of
the individual system components, this charge-sensitive model cannot be further validated.
5. Conclusion
The goal of this work is to investigate and compare different empirical correlations for simulating the
heat exchangers in a charge-sensitive ORC simulation tool. To this end, a 2kWe recuperative ORC
unit is used as case study and experimental measurements are gathered as reference dataset. The ORC
system features two brazed plate heat exchangers and one fin coil condenser. For these three heat
exchangers, various empirical correlations derived from the scientific literature are tested in order to
evaluate both the fluids void fractions and their convective heat transfer coefficients. The reliability
of these models is assessed by confronting the simulation predictions to the experimental data.
10
Figure 5. Charge inventory predicted by the ORC model #19 with Hughmark’s void fraction
More specifically, the current study compares:
- 9 models of brazed plate heat exchangers built by combining different heat transfer
correlations of single-phase, condensing and boiling flows;
- 2 models of air-cooled fin coil condenser;
- 3 correction methods to enhance the models thermal prediction;
- 4 void fraction models (homogenous, Zivi, Lockhart-Martinelli and Hughmark).
Ultimately, 288 different models of the ORC are compared for predicting both the heat exchangers
thermal performance and the total mass enclosed in the ORC unit. The main outcomes of the study
are the following ones:
- The original correlations characterizing the heat transfer coefficients in the brazed plate heat
exchangers should not be considered trustful and they require to be corrected for improving
their thermal performance predictions. The models of the condenser, on the other hand,
demonstrate better agreement with the experimental data.
- By altering the heat transfer correlations, the thermal performance of the heat exchanger
models is improved but the charge inventory of the ORC system is deteriorated. The best
correction method applied to the heat transfer correlations appears to be the less intrusive
(correction method #1). By only scaling one correlation in the heat exchanger models (see
equation (3)), it is possible to much better predict the heat transfer in the heat exchangers
while ensuring a proper mass estimation in the ORC unit.
- The best void fraction model identified is the one proposed by Hughmark which accounts for
the influence of the fluid mass flux. It is interesting to note that similar analyses applied to
HVAC systems [e.g. [5], [28]] also identified this model to be the best for characterizing the
fluids void fraction.
- Accounting for the fact that the experimental charge in the ORC system was 26kg, the best
modelling approach permits to estimate a mean mass of 25.12kg over 40 different operating
conditions with a standard deviation of 1.7kg. The deviation from the experimental charge is
maximum 13.5 % and it drops to 6.3% in average.
- In the current analysis, the best modelling method is chosen to be the one offering a good
compromise between reliable thermal performance predictions of the heat exchanger models
and proper mass estimation in the ORC system. Future work would require to better assess
11
the influence of these effects on the performance modelling of the global ORC system. Indeed,
it might be interesting to give more credit to one criteria over the other (i.e. the proper
predictions in the heat exchangers over the mass modelling in the system) if its effect was
demonstrated to be more important on the simulation of the entire system.
- In this work, the charge-sensitive ORC model is validated in terms of global charge prediction
only. In order to better validate the model and its charge inventory predictions, experimental
measurements of the mass repartition between the different components would be required.
Nomenclature
Acronyms
Greek symbols
BPHEX
Brazed plate heat exchangers
α
Void fraction, -
CD
Condenser
β
Weighting factor, -
EV
Evaporator
ρ
Density, kg/m³
EXP
Expander
ω
Volume fraction, -
HEX
Heat Exchangers
HVAC
Heating Ventilation Air Conditioning
Subscripts
NRMSE
Normalized Root Mean Square Error
i,j,k
indices
ORC
Organic Rankine Cycle
exp
experimental
PP
Pump
sim
simulated
REC
Recuperator
min
minimum
max
maximum
Variables
v
vapour
A
Surface area, m²
l
liquid
c
Correction factor, -
tot
total
M
Mass, kg
tp
two-phase
Nu
Nusselt number, -
pp
pump
Heat power, W
Re
Reynolds number, -
S
Slip ratio, -
V
Volume, m³
Xtt
Lockhart-Martinelli factor, -
x
Quality -
References
[1] R. Dickes, O. Dumont, R. Daccord, S. Quoilin, and V. Lemort, “Modelling of organic Rankine cycle
power systems in off-design conditions: an experimentally-validated comparative study,” Energy,
2017.
[2] R. Dickes, O. Dumont, A. Legros, S. Quoilin, and V. Lemort, “Analysis and comparison of different
modeling approaches for the simulation of a micro-scale organic Rankine cycle power plant,” in
Proceedings of ASME -ORC 2015, 2015.
[3] I. H. Bell, S. Quoilin, E. Georges, J. E. Braun, E. A. Groll, T. W. Horton, and V. Lemort, “A generalized
moving-boundary algorithm to predict the heat transfer rate of counterflow heat exchangers for any
phase configuration,” Appl. Therm. Eng., vol. 79, pp. 192–201, 2015.
[4] R. Dickes, D. Ziviani, M. de Paepe, M. van den Broek, S. Quoilin, and V. Lemort, “ORCmKit : an
open-source library for organic Rankine cycle modelling and analysis,” in Proceedings of ECOS 2016,
2016.
[5] M. Farzad and D. L. O’Neal, “The effect of void fraction model on estimation of air conditioner system
performance variables under a range of refrigerant charging conditions,” Int. J. Refrig., vol. 17, no. 2,
pp. 85–93, 1994.
[6] C. K. Rice, “Effect of Void Fraction Correlation and Heat Flux Assumption on Refrigerant Charge
12
Inventory Predictions.,” in ASHRAE Transactions, 1987, vol. 93, no. 1, pp. 341–367.
[7] C. Cuevas Barraza, “Contribution to the modelling of refrigeration systems,” University of Liège, 2006.
[8] R. Dickes, O. Dumont, S. Declaye, S. Quoilin, I. Bell, and V. Lemort, “Experimental investigation of
an ORC system for a micro-solar power plant,” in Proceedings of the 22nd International Compressor
Engineering at Purdue, 2014.
[9] Z. H. Ayub, “Plate Heat Exchanger Literature Survey and New Heat Transfer and Pressure Drop
Correlations for Refrigerant Evaporators,” Heat Transf. Eng., vol. 24, no. 5, pp. 3–16, 2003.
[10] R. L. Amalfi, F. Vakili-Farahani, and J. R. Thome, “Flow boiling and frictional pressure gradients in
plate heat exchangers. Part 1: Review and experimental database,” Int. J. Refrig., vol. 61, pp. 166–184,
2016.
[11] R. Eldeeb, V. Aute, and R. Radermacher, “A survey of correlations for heat transfer and pressure drop
for evaporation and condensation in plate heat exchangers,” Int. J. Refrig., vol. 65, pp. 12–26, 2016.
[12] E. Macchi and M. Astolfi, Organic Rankine Cycle (ORC) Power Systems - Technologies and
Applications. Woodhead Publishing, 2016.
[13] H. Martin, “A theoretical approach to predict the performance of chevron-type plate heat exchangers,”
Chem. Eng. Process., vol. 35, no. 4, pp. 301–310, 1996.
[14] S. A. Wanniarachchi, U. Ratnam, B. E. Tilton, and K. Dutta-Roy, “Approximate correlations for
chevron-type plate heat exchangers,” in Proceedings of the 30th National Heat Transfer Conference,
1995, pp. 145–151.
[15] R. L. Amalfi, F. Vakili-Farahani, and J. R. Thome, “Flow boiling and frictional pressure gradients in
plate heat exchangers. Part 2: Comparison of literature methods to database and new prediction
methods,” Int. J. Refrig., vol. 61, pp. 185–203, 2016.
[16] D.-H. Han, K.-J. Lee, and Y.-H. Kim, “Experiments on the characteristics of evaporation of R410A in
brazed plate heat exchangers with different geometric configurations,” Appl. Therm. Eng., vol. 23, pp.
1209–1225, 2003.
[17] M. G. Cooper, “Heat flow rates in saturated nucleate pool boiling – a wide- ranging examination using
reduced properties,” Adv. Heat Transf., vol. 16, pp. 157–239, 1984.
[18] G. A. Longo, G. Righetti, and C. Zilio, “A new computational procedure for refrigerant condensation
inside herringbone-type Brazed Plate Heat Exchangers,” Int. J. Heat Mass Transf., vol. 82, pp. 530–
536, 2015.
[19] D. H. Han, K. J. Lee, and Y. H. Kim, “The caracteristics of condensation in brazed plate heat exchangers
with different chevron angles,” J. Korean Phys. Soc., vol. 43, no. 1, pp. 66–73, 2003.
[20] M. M. Shah, “A general correlation for heat transfer during film condensation inside pipes,” Int. J. Heat
Mass Transf., vol. 22, no. 4, pp. 547–556, 1979.
[21] VDI Heat Atlas. Springer-Verlag Berlin Heidelberg.
[22] A. Cavallini, D. Del Col, L. Doretti, M. Matkovic, L. Rossetto, C. Zilio, and G. Censi, “Condensation
in Horizontal Smooth Tubes: A New Heat Transfer Model for Heat Exchanger Design,” Heat Transf.
Eng., vol. 27, no. 8, pp. 31–38, 2006.
[23] C. Wang, K. Chi, and C. Chang, “Heat transfer and friction characteristics of plain fin-and- tube heat
exchangers , part II : Correlation,” vol. 43, pp. 2693–2700, 2000.
[24] R. A. Waltz, J. L. Morales, J. Nocedal, and D. Orban, “An interior algorithm for nonlinear optimization
that combines line search and trust region steps,” Math. Program., vol. 107, no. 3, pp. 391–408, 2006.
[25] S. M. Zivi, “Estimation of steady-state steam void-fraction by means of the principle of minimum
entropy production,” J. Heat Transfer, vol. 86, no. 2, pp. 247–251, 1964.
[26] R. W. Lockhart and R. C. Martinelli, “Proposed correlation of data for isothermal two-phase two-
component flow in pipes.pdf,” Chem. Eng. Prog., vol. 45, no. 1, pp. 39–48, 1949.
[27] G. A. Hughmark, “Holdup and heat transfer in horizontal slug gas-liquid flow,” Chem. Eng. Sci., vol.
20, no. 12, pp. 1007–1010, 1965.
[28] M. Grodent, “Contribution à l’étude des composants de systèmes frigorifiques: modélisation en régime
stationnaire et validation expérimentale. Application des modèles développés à l’étude d’un système
‘bisplit,’” University à Liège, 1998.