3D Roof Model Generation and Analysis Supporting Solar System Positioning

Authors:

Abstract and Figures

Given the growing needs of renewable energy in urban areas, identifying suitable installation locations for solar systems is increasingly important. Existing energetic cadastres often have a limited level of detail in the analysed geometry, which needs to be rapidly updated following any changes to the buildings. The required 3D data can be generated by photogrammetry techniques and Structure-from-Motion (SfM) software. In this paper, the method was tested employing Digital Mapping Camera images (virtual images), on a case study in northwest Italy. The results are analysed for assessing the reliability of the DSM produced by SfM methods, to be employed in solar radiation analyses. The problem of this kind of automatic 3D modelling can be the excessive detail sometimes required in reconstructing the geometry of the roofs and the possible noise. The results are managed and analysed through Geographical Information System (GIS) tools. For the whole workflow, proprietary and free open source software (OSS) are used. The problems and limitations are investigated in order to evaluate and confirm the reliability and cost effectiveness of the described methods.
Content may be subject to copyright.
13 August 2018
POLITECNICO DI TORINO
Repository ISTITUZIONALE
3D roof model generation and analysis supporting solar system positioning / Chiabrando, Filiberto; Danna, Chiara;
Lingua, Andrea; Noardo, Francesca; Osello, Anna. - In: GEOMATICA. - ISSN 1195-1036. - ELETTRONICO. -
71:3(2017), pp. 137-153.
Original
3D roof model generation and analysis supporting solar system positioning
Publisher:
Published
DOI:10.5623/cig2017-301
Terms of use:
openAccess
Publisher copyright
(Article begins on next page)
This article is made available under terms and conditions as specified in the corresponding bibliographic description in
the repository
Availability:
This version is available at: 11583/2700334 since: 2018-02-19T16:01:41Z
Canadian Institute of Geomatics
3D roof model generation and analysis supporting solar system
positioning
Filiberto Chiabrando1, Chiara Danna2, Andrea Lingua2, Francesca Noardo2, Anna Osello3
1 Politecnico di Torino - DAD, viale Mattioli, 39 10125 Torino
2 Politecnico di Torino - DIATI, c.so Duca degli Abruzzi, 24 10129 Torino
3 Politecnico di Torino - DISEG, c.so Duca degli Abruzzi, 24 10129 Torino
filiberto.chiabrando@polito.it, chiara.danna@polito.it, andrea.lingua@polito.it,
francesca.noardo@polito.it, anna.osello@polito.it
Abstract
Given the growing needs of renewable energy in urban areas, identifying suitable installation locations for
solar systems is increasingly important. Existing energetic cadastres have often a limited level of detail in the
analysed geometry, which needs to be rapidly updated following any changes in the buildings. The required
3D data can be generated by photogrammetry techniques and Structure-from-Motion (SfM) software. In this
paper, the method was tested employing Digital Mapping Camera images (virtual images), on a case study in
north-west of Italy. The results were analysed for assessing the reliability of the DSM produced by SfM
methods, to be employed in solar radiation analyses. The problem of this kind of automatic 3D modelling
could be sometimes the excessive detail in reconstructing the geometry of the roofs or the possible noise.
The results are managed and analysed through Geographical Information System (GIS) tools. For the whole
workflow, proprietary and free open source software (OSS) were used. The problems and limitations were
investigated in order to evaluate and confirm the reliability and cost effectiveness of the described methods.
Keywords: Photogrammetry, structure-from-motion, open source, solar irradiation, GIS, surface analysis,
DSM.
1. INTRODUCTION
The use of energy from renewable sources, in particular solar energy, is very challenging in urban
environments, where the density of buildings is very high, and few surfaces are available. A key issue, for
both private and public investors, is to identify and analyse surfaces best suited for the installation of
photovoltaic or solar systems. Since the operators planning these activities are often professionals or
administrators with different competences, a system that provides reliable results in an automatic or semi-
automatic way could play a key role. Geomatics methods can be effective for this aim.
For the mapping of solar radiation, GIS (Geographical Information System) tools are an actual solution
(Borfecchia et al., 2013, Hofierka et al., 2014), as demonstrated by the solar cadastres in some cities (for
example New York, Boston, Bolzano, Morgex), available on the web. However, these services are limited in
the level of detail of the roof analysis because they sometimes do not evaluate the real surface available nor
the possible presence of obstacles on the roofs, such as dormers and chimneys. This deficiency is due to the
fact that these applications consider rather large geographical areas and may not exploit the most appropriate
information. Even when LiDAR information is available, it often does not extract a dense three-dimensional
representation, since generally the resolution is too low to acquire all the necessary details (Borfecchia et al.,
2013). For example, the maximum density for a scale 1:2000 point cloud is usually 1 point every 0.80 m,
which is not enough to capture all the useful details.
Other studies have employed photogrammetric systems for reconstructing detailed 3D models of buildings
(Agugiaro et al., 2012). However, in this study, a very particular case is considered, since images acquired by
a DMC (Digital Mapping Camera) are available, which are not usually processed in recent automatic
software. It is a critical issue, even if the Structure from Motion (SfM) technique is nowadays well affirmed.
In fact, it is usually employed to process close range images or common aerial images, which can have major
distortions but a simpler geometry, since they are not the result of a composition of many images.
Once a suitable and accurate 3D representation of the roofs is achieved, which are usually the most available
surfaces for solar panel installation in urban environments, their surfaces are analysed by solar radiation GIS
tools. The results are validated by a comparison with the norm values for the geographical location
considered. Moreover, a deeper analysis of the raster maps extracted by the DSM and critical to compute the
received solar radiation (aspect and slope) is performed, in order to verify the reliability of the generated
DSM by SfM technique, to be used for supporting solar radiation analyses. A summary of the phases is
reported in Figure 1.
Figure 1: Flow-chart showing progress from DMC images to the 3D roof analysis.
The first objectives of this research is, therefore, the validation and test of the SfM technique employing
DMC images.
Secondly, the analysis of the obtained 3D surfaces of the roofs is a central purpose of this study, to evaluate
the reliability of the information extracted from them (slope, aspect, solar radiation information),
notwithstanding the possible noise affecting some SfM products (due to the high level of detail, remaining
outliers or simple noise effects). Some tests varying the computed values are performed, and some statistics
are computed in order to assess the accuracies threshold in the surface analysis products. This permits the
validation of the method to be used for cost and time effective mapping and analysis.
For each step in the study, we used open source software (OSS). The OSS proposes suitable tools to promote
the sharing and exchange of data and information. OSS has two main advantages compared to proprietary
software, which is important both for public administrations that need to respect the instructions, for
example, in the Italian Circular 63/2013 (Agenzia per l’Italia Digitale, 2013), and also for private companies.
Firstly, OSS saves on expensive licensing and maintenance costs, and also promotes the data interoperability
by using open formats and implementing international standards. Secondly, the knowledge of the source
code is a key element for effectively monitoring and controlling the software. This enables the user to adapt
the processing to specific needs and, where necessary, to correct, change or enhance the software itself, thus
contributing to its improvement.
The test site considered in this paper is an area of Turin (north-west Italy) analysed during the DIMMER
Project (District Information Modeling and Management for Energy Reduction). DIMMER is an EU project
of the Seventh Framework Program for research and technological development set up in Manchester and
Turin. In this project (2013/2016), industries, research centres and universities were involved, including the
Politecnico di Torino, where the authors of this paper conduct their research. The aim of DIMMER was to
realize an open platform for real time data processing, visualization and monitoring of energy consumption
and production from renewable sources. In this paper, the proposed semiautomatic method for the generation
of a 3D model of an area of Turin for supporting solar systems installation is described. Moreover, the data
analysis in a GIS platform is also reported.
2. THE ROOF GEOMETRY MEASUREMENT AND RECONSTRUCTION:
PHOTOGRAMMETRY AND SFM
The first objective was to generate a suitable 3D model of the roofs in the area using a photogrammetric
approach. Existing images were used to realize a traditional photogrammetric plotting (vector map). The
results of the manual plotting were compared with the results obtained using more automatic digital
photogrammetry, Structure from Motion (SfM) and dense matching software tools.
The test area (approximately 0.2 km2) was in the “Crocetta” district in Turin (Figure 2). The terrain is quite
flat, but the buildings present different sizes and geometries.
Figure 2: Google map of the study area
The initial data consisted of 10 aerial images acquired in 2007 for an orthophoto map of Piemonte (the
Region where Turin is located), from a flight height of about 900 m, permitting nominal scale of 1:2000:
0.40 m for both plane (tolerance 0.69 m) and height (tolerance 0.80 m) accuracy (Brovelli et al., 2010). The
GSD of such images, considered the flight height and the pixel dimension, is 0.09 m on the ground. The
GSD is quite smaller on the higher areas, such as the building roofs, but, due to the high flight height, the
difference is not so meaningful. The data were acquired by a Zeiss Imaging (Z/I) Digital Mapping Camera
(DMC). This is a turnkey, frame-based digital aerial camera system designed to support aerial
photogrammetric missions requiring high-resolution and accuracy. The DMC uses eight individual lenses
rather than a single lens. The lenses operate simultaneously and collect colour imagery (RGB), CIR (colour
infrared), and black-and-white panchromatic imagery. After the flight, the captured image data are
normalized, verified, rectified, colour coded, formatted and made available for digital photogrammetric
production.
The first post-processing step is to generate Level 1 images, which include the elimination of defect pixels
and a normalization (Diener et al., 2000). Next, the image data are geometrically converted, that is, they are
transformed to reduce the perspective distortions, and mosaicked. Finally, the virtual image is generated, and
the lens distortions are geometrically corrected, based on the camera calibration. The images created in this
way have a new, virtual, camera constant, that is, new independent interior orientation parameters, and can
be considered as ideal central perspective photogrammetric images. The employed images were provided
with the interior calibration and the external orientation parameters: pose coordinates (X,Y,Z) and attitude
(,,). The exterior parameters were calculated during the bundle block adjustment using traditional digital
photogrammetric software, which combined the information from the on board sensors (GNSS and IMU)
and several Ground Control Points (GCPs) previously measured on the terrain. The DMC images are often
available, since they are used for building regional orthophotos, and represent an imaging product covering
wide portions of land with a higher detail than satellite images. Therefore, testing a procedure for extracting
the currently used geomatics and cartographic products from these images is a great opportunity,
notwithstanding some problems to be overcome. The main issue is the management of virtual images in SfM
software, which were generally conceived to automatically process simple central-perspective images, with
integrated EXIF information.
Since the solar radiation received by the surfaces is strongly influenced by their three-dimensional
conformation, a dense Digital Surface Model (DDSM) of the area is needed in order to perform a correct
analysis using raster analysis tools in GIS platforms. The processes followed to obtain the most suitable
DDSM are summarized in Figure 3.
Figure 3: Processing schema for the generation of the dense DSM.
For obtaining a reference product (ground truth), which is useful for checking the reliability of the results
processed through an image-matching approach, a traditional stereoscopic plotting was performed using Z-
Map software (www.mencisoftware.it,). This represents a highly controlled 3D drawing of the area, with a
very high level of detail, which also offers a better reference than the sometimes available aerial LiDAR
data.
For assessing the accuracy of the manual plotting, some empiric rules were applied:
Where:
= the accuracy of the marked point in XY directions = ±6µm on the image
= the accuracy of the marked point in Z direction = ±0.06 of the shooting distance
= the accuracy of the point aimed on the image in XY directions = 7 cm
= the accuracy of the point aimed on the image in Z direction = 8 cm
and are the accuracies of the natural points in the final plotted model in the XY and Z
directions.
= 7 cm and = 9.65 cm
The plotting also avoids neglecting the small geometries of the roofs, such as chimneys or dormers. The
plotted model was then converted into a Dense DSM and a dense Point Cloud using a homemade software
“DDSM to dxf” (Biasion et al., 2004).
The image-matching methodology was developed and tested for remotely sensed data. It was employed to
compute exterior orientation of images in photogrammetry processing and to extract Digital Terrain Model /
Digital Surface Model (DTM/DSM) from aerial or satellite stripes (Marr & Hildreth, 1980; Torre & Poggio,
1986; Ackermann, 1984; Baltsavias, 1991). Recently, the methodology has been extensively used in close-
range applications concerning architectural and archaeological surveys (Aicardi et al., 2016; Bastonero et al.,
2014; Chiabrando et al., 2013; Toldo et al., 2013; Kersten & Lindstaedt, 2012; Remondino & Menna, 2008).
The developed technique was tested here in an urban context. The images were processed automatically
using the proprietary low-cost software Agisoft PhotoScan (www.agisoft.ru) and the open source suite
Apero–MicMac implemented by IGN (Institut National de l’Information Géographique et Forestière, Paris)
(Deseilligny & Cléry, 2011). In both cases, the DMC aerial images and their exterior and interior orientation
parameters were used in order to orient the images, to generate the point clouds and the dense DSMs, and,
finally, the orthophoto. The data-processing was performed on the total area covered by the images and
required a few hours to generate the final results.
In order to perform the image matching, the interior orientation parameters (provided in the calibration
certificate) were fixed. This was necessary since the DMC images are provided without any Exif file. The
Exif file is usually attached to each digital image, and describes its main details (date and hour when it was
shot, image dimensions, used focal length and so on). Such details are read by many photogrammetric and
SfM software to obtain parameters useful to initialize the alignment and orientation of the images. In the case
of virtual images deriving from some pre-processing (e.g. the DMC images or spherical images), the virtual
geometry does not always enable the correct focal length and distortion parameters to be automatically
estimated, since very specific procedures are necessary (Dörstel, 2003). Therefore, the software tools used, at
present, cannot automatically calculate the calibration parameters. In particular, Agisoft Photoscan does not
work and MicMac calculates a wrong focal length (7.5 mm instead of 120 mm).
For the point cloud and DSM generation, the typical data workflow of this kind of software was followed. In
PhotoScan, high resolution Tie Point Extraction and Dense Matching were set up. As a consequence, a
final 65.838.239 point cloud was achieved and subsequently the DSM was generated. In MicMac, using the
Ortho option in Malt (simplified MicMac tool), a dense 50.664.687 point cloud was created. The DSM
(stored as integer values to optimize the memory use) were converted into float values (Section 2.1.2) which
are useful for data comparison. The results of the adjustments of the two software respect the input exterior
orientation values are summarized in Table 1
Table 1: Statistics of the processing results: discrepancies of the exterior orientation values adjusted by the
software and the ones provided with the images
MicMac
PhotoScan
Minimum distance [m]
0.711
0.090
Maximum distance [m]
0.766
0.303
Mean distance [m]
0.741
0.165
Standard deviation [m]
0.018
0.032
2.1. Analysis of results and comparisons
The DSMs (grid 20 cm) and the 3D point clouds obtained by the photogrammetry and image matching
software tools (MicMac and Photoscan) were compared to the roof shape generated by the manual plotting,
in order to evaluate their precision and accuracy. Since these latter data, used as the reliable ground truth, are
related to a restricted area of interest, only the image matching results concerning this area were considered,
in order to exclude the external parts from the analysis, and thus avoid misleading errors.
2.1.1. MicMac point cloud vs PhotoScan point cloud
The comparison between the point clouds was performed using CloudCompare, an OSS that enables 3D
models and point clouds to be analysed and measured using several tools (Girardeau-Montaut, 2011). The
point to point distances, and thus the discrepancies, between the clouds generated by the SfM software and
the reference point cloud, derived from the transformation of the manual plotted model were automatically
computed, using the method Nearest Neighbour distance. The statistical results are summarized in Table 2,
where the mean value could be considered as representative of the point cloud accuracy, in absence of biases.
The gross errors (distance major than 5 m) were removed and not considered for the analysis. However, the
point clouds used to perform these analyses are still the complete ones, without any cleaning or filtering,
because it was important to evaluate the quality of the entire product; therefore some outliers or noisy objects
increase the measured discrepancies to the reference points in some areas. Especially, the higher
discrepancies are located on the borders and in correspondence of breaklines. Once the clouds are filtered,
eliminating a 20% of these points, the values in Table 3 can be obtained. Table 4 and Figure 4 represent the
percentage of points respecting the accuracies () and tolerances (2) for a 1:2000 scale. Equally, after a
filtering and cleaning process, the percentage of the points included in the tolerance range (0.0 0.80 m)
increases approximately to the 95%, respecting the validation rules for mapping products.
Table 2: Statistics on the discrepancies between the 3D point clouds produced by MicMac and PhotoScan,
without any editing process, and the manually extracted data (as reference).
MicMac
PhotoScan
Minimum distance [m]
0
0
Maximum distance [m]
2.960
3.687
Mean distance [m]
0.815
0.565
Standard deviation [m]
0.486
0.597
Table 3: Statistics on the discrepancies between the 3D point clouds produced by MicMac and PhotoScan after
an editing process, and the manually extracted data (as reference).
MicMac
PhotoScan
Minimum distance [m]
0
0
Maximum distance [m]
0.901
1.052
Mean distance [m]
0.232
0.196
Standard deviation [m]
0.298
0.301
Table 4: Percentage of points of the generated point clouds respecting the expected accuracies for 1:2000 scale
map, derived from the comparison with the reference ground truth (the manually plotted data).
Accuracy range [m]
MicMac
Photoscan
0.0 - 0.40
17.81 %
49.34 %
0.0 - 0.80
57.02 %
83.24 %
0.0 1.20
86.17 %
91.31 %
Figure 4 Cloud to cloud comparison: percentage values distribution
Unfortunately, some points with measured coordinates on the ground, to be used as check points were not
available Therefore it was not possible to further assess the quality of the point cloud by means of further
statistics and analysis.
2.1.2. MicMac DSM vs PhotoScan DSM
The other analysed products were the DSMs. PhotoScan can easily and automatically provide this data: the
algorithm it uses is unknown, however, a high number of scientific researches and tests on cases studies
prove its reliability. On the other hand, for MicMac, various intermediate steps are needed. One way is to
interpolate the dense point cloud, whose correctness and accuracy were verified beforehand, in GIS software
(in this case QGIS with a linear interpolation algorithm was used). Alternatively, a DSM can be built using
MicMac (which also uses a linear interpolation). However, for the latter, it is necessary to correct the
generated raster values, since MicMac optimizes the memory by calculating the height raster values using
the voxel cell (expressed as height resolution), and establishes an arbitrary height origin, when it produces
the TIFF file. This avoids negative values and enables only integer numbers to be managed. The procedure is
thus faster and occupies a smaller memory space. This raster therefore had to be transformed into a product
to be compared with the other products. The raster calculator tool in QGIS was used, following the relation
“(raster value * height resolution) + height origin”. The two DSMs were compared to the reference one
(derived from the manual plotting) using, again, the QGIS Raster Calculator tools. The differences between
the cells in a similar location were computed.
QGIS (www.qgis.org) is a free and OS desktop GIS (subject to the GNU General Public License), which has
a user-friendly interface and performs the spatial analysis and processing typical of GIS. It also has some
benefits due to the huge number of tools exploitable in the software, fulfilling customized processing needs.
The typical QGIS functionalities can be enhanced by other specific python programmed plug-ins, or
integrated tool sets from different platforms, such as GRASS (Geographic Resources Analysis Support
System) (Neteler et al., 2012), SAGA (System for Automated Geoscientific Analysis), Orfeo Toolbox, and
so on.
In order to focus on the surface of the roofs, which were our main interest, some preliminary operations were
performed. Only the roofs were extracted by masking the buildings with the areas defined in the Turin digital
map (scale 1:2000), using clipping tools in GIS. Since the raw data used to produce the Turin digital map
were the same DMC images, with the same parameters, there were no noticeable discrepancies in the
superimposition of the two maps. This masking operation was necessary to exclude the areas that could
include some misleading statistics, such as the trees along the streets, cars and so on.
Finally, the discrepancies (Figure 5) were calculated through the Raster Calculator” tool, which makes
calculations using raster values. The mean values (Table 5), highlight that the PhotoScan DSM was the
nearest to the reference one. The two DSMs derived from the MicMac data show that on most of the surfaces
the results were quite similar, but there were problems in areas corresponding to particularly shadowed or
dark roofs: these parts were not included in the MicMac DSM. On the other hand, the DSM interpolated in
QGIS from the MicMac point cloud presented high errors in those same areas (up to 20 m). We thus chose
the DSM produced directly by MicMac, in order to prevent the wrong areas from affecting the further
analysis. The final DSMs have a 0.20 m grid.
.a
.b
Figure 5: Comparison between DSMs: Manual/MicMac (a) and Manual/PhotoScan (b). The legend is in m.
Table 5: Statistical values of discrepancies between the DSMs and the reference data. The high values in the max
cells are due to the outliers distributed on the borders, where the SfM DDSMs are less defined, whereas in the
manually plotted DDSM the breaklines are clearly drawn; however mean values respect the required accuracies.
The standard deviation values are not reliable, since they are too influenced by the outliers in noisy areas.
MicMac
MicMac + QGIS
PhotoScan
0
0
0
35.095
37.155
35.204
0.593
0.666
0.245
1.825
3.290
1.228
The generation of the DDSM through the tool “DDSM to dxf”, used to convert the 3D plotting into a DDSM
and a point cloud, was actually innovative when it was proposed (Biasion et al., 2004), since it allowed the
generation of more accurate orthophotos and final cartographic products. Nowadays the use of the SfM
software tools seems to be often sufficient to obtain very detailed and defined point clouds and derived
products. However, if the images have a low resolution, with high GSD values (as in the DMC images,
aiming at 1:10000 representation scale), the number of pixels representing each surface is low and, therefore,
the geometry can be not so clear, especially for defining the breaklines of the 3D model. Furthermore, some
areas (such as the shadowed or dark areas) have problems when the contrast with neighbouring areas is too
high or too low. For these reason it could be a good solution to integrate the two techniques. The SfM
algorithms can extract a high number of points for reaching a high level of detail in the reconstructed
geometry, also including small details; but for defining some critical breakline or objects which are not
sufficiently clear for SfM algorithms, some plotted lines could be fundamental to increase the DDSM
quality.
2.2. FILLING THE HOLES
Analysing the completeness of the results, some noisy or missing areas in relation to shadowed zones and
dark roofs (Figure 6) were evident. This noise is quite common due to the various factors conditioning the
matching process, such as the radiometric quality of the images, image overlapping, shadows and texture (or
external features) of the buildings.
a b
Figure 6: Portion of an aerial image (a) with a dark roof (red square) and the lack of relevant information in the
generated point cloud (b).
Since the problem could be due to the radiometric and contrast values characterizing the portion of the image
(shadowed areas or dark surfaces are affected) (Chiabrando et al., 2014), we completed the model by
performing another SfM processing using the same images with modified radiometric and tonal values. In
particular, three changes were made to the radiometric values of the original images (in the following
identified with “A”) using Adobe Photoshop or an OSS alternative such as Gimp:
conversion into gray scale (B);
change in tonal values (C);
conversion into gray scale plus the change in tonal values (D).
We thus reduced the shadowed or dark areas, making them more visible with respect to the background, in
order to evaluate the possible improvement in the processed model.
Each set of images was processed separately, following the same workflow explained above. The results
were compared, considering both the accuracies of the model, and the completeness of its content. Table 6
shows how the accuracies in the different models are very similar, so that it is possible to consider their
integration. Figure 7 indicates the gaps in the different models. Since the gaps are complementary, they can
be integrated into a complete model.
Table 6: Statistical values of residuals on 25 check points extracted from the stereoscopic model, for: original
images (A), grey scale images (B), modified tonal values (C), grey scale images + modified tonal values (D).
A
B
C
D
Minimum distance [m]
0.090
0.092
0.091
0.088
Maximum distance [m]
0.315
0.293
0.315
0.290
Mean distance [m]
0.170
0.155
0.174
0.161
Standard deviation [m]
0.068
0.063
0.068
0.062
Figure 7: Completeness differences in the DSMs generated from the different sets of images: the circles indicate
that the area is present in the model reported in the legend: original images (A), grey scale images (B), modified
tonal values (C), grey scale images + modified tonal values (D).
The model derived from the original images was then completed by adding the missing parts from the other
models. To perform the integration, various attempts were made considering the point clouds, which are the
first generated product, from which the others are derived. However, the best solutions were found by
considering the DSMs directly, by integrating the missing parts in the model generated from the original
images. This was performed using the Raster Calculator tools in QGIS. In particular, only the roofs were
masked and extracted from the various DSMs, and the raster images were integrated in the parts where “no
data” value was read in the reference DSM. The complete roofs DSM was thus obtained starting from the
available DMC images, without requiring further acquisition phases (Figure 8).
Figure 8: Final integrated DSM.
For this test, Agisoft PhotoScan was used. Similar results, or even better ones, could probably be obtained
using MicMac due to the possibility of having more control on the settings in the processing phases.
3. ANALYSIS OF ROOF SURFACE AND EXTRACTION OF INFORMATION IN GIS
On the basis of the digital models, by using various tools of the GIS software it is possible to extract
information on the solar radiation received by a surface. This is critical information for planning solar panels
and system installation. The aforementioned surface analysis processing tools are typical in both proprietary
and OS GISs. In this case, QGIS was used again by exploiting the GRASS GIS algorithms, integrated in the
QGIS interface. The reliability of the results of the different modules available in GRASS GIS has been
tested in a variety of studies (Hofierka & Šuri, 2002; Šuri & Hofierka, 2004). Obviously, the data extracted
from the manual DSM are less noisy than the other data, however, if considering the average or median
values on homogeneous surfaces, it is possible to verify that the data produced by an image matching
approach are compliant with the considered accuracies, and, thus, can be considered reliable.
To perform the analysis of solar irradiation the GRASS tool r.sun - solar irradiance and irradiation model,
was used. This module calculates five different maps (irradiation layer, insolation time, diffuse irradiation
layer, ground reflected irradiation layer, and global irradiance / irradiation layer) in clear-sky conditions, and
therefore it does not take into consideration the presence of clouds. The analysis is not only based on the
DSM, but is a function of many factors such as aspect, slope, latitude, longitude, declination value, air
turbidity coefficients (linke data), and the percentage of diffuse components of the radiation. This
information (except for the shadow mask) has to be manually introduced into the shell to run the algorithm.
This may be more difficult than a similar process run by other proprietary software, however it enables each
step of the processing to be monitored, controlled and customized. Studies have also shown how this
software offers more correct and precise results than other proprietary software (Nex et al., 2013). In the
analysed case, the processes were performed during the days of the solstice and equinox, and the shadows
were incorporated within the results.
Some parts may be difficult for non-expert users, as the plug-ins often need specific formats in input data.
For example, the plug-in that computes solar radiation requires the raster maps of the latitudes and longitudes
expressed in decimal degrees, however there is currently no specific tool for this task. This requires several
steps, each of which needs specific parameters to be set. Therefore, a graphical model was defined through
the expressed module in QGIS (http://areeweb.polito.it/geomatics_lab/download/latitute-and-longitude-
generation-in-q-gis/). The QGIS graphical model module enables complex models to be defined using a
simple interface: the sequence of plug-ins to be run on specific input data can be defined, with pre-set
parameters, to obtain the result needed. This saves time and the effort of repeating the same process several
times. The model could be enhanced to include full processing (from the DSM to the generation of aspect
and slope maps, to the computing of the solar radiation map). This could be useful if these analyses become
“good practice” for Public Administrations, which could rapidly obtain useful data.
However, it is useful to consider the approximate errors affecting the slope and aspect maps derived from the
DSM processed by MicMac. It is clear, looking at the Figures 9 and 10, that the surfaces of the roof pitches
are not smooth, but are affected by some errors. They are due to the many details visible in the images and
used to reconstruct the geometry (sometimes a synthesis of a model is necessary, and too many details could
give problems in processing some algorithms). Moreover, some areas are affected by noise, which can
disturb the model.
Figure 9: Aspect analysis with manual DSM (upper) and MicMac DSM (lower)
Figure 10: Slope analysis with manual DSM (upper) and MicMac DSM (lower)
The DSM processed through SfM technique was apparently too noisy, compared to the one generated from
the manual plotting, so as, consequently, the product generated from it (Figures 11 and 12). For this reason, a
deeper test was realized for assessing the reliability of the information extracted from the DSM computed
through SfM technique.
Figure 11 Raster maps of aspect values generated from the manually plotted DSM and from the SfM DSM.
The important object are the roofs, so that the noise outside the roofs area can be ignored, since it is due to other
objects present on the ground, vegetation and further interpolation errors where the data are confused.
Figure 12 Raster maps of slope values generated from the manually plotted DSM and from the SfM DSM.
A sample of pitches were considered, oriented in different directions (approximately 20 pitches for each
direction, which, in the case study, are north-east, north-west, south-east and south-west). They are visible in
Figure 13. Also a sample of flat pitches was investigated, but the results are not here reported because the
resulting raster images were too noisy and they presented a number of blunders. Moreover, for evaluating the
installation of solar systems on flat roofs it is simply necessary to generate a shadow mask of the area, since
the values of solar radiation do not change for the whole area. The values in correspondence of the inclined
pitches were considered for performing some statistical analyses on the specific areas. These values and their
statistics were computed by means of the ZonalStatistics tool in QGIS.
Figure 13 Map of the roof pitches sample considered for extracting the raster values and performing the
analyses.
First of all, the difference between the values of slope and aspect extracted from the two DSMs were
compared, since they influence the computation of the solar radiation received by the mapped surfaces. The
results are summarized in Table 7. In the Tables 7 and 8 the weighted average on the surface units (the raster
pixels) are reported, so that the obtained values are independent from the area of the considered pitches.
Table 7 Comparison of the values of the slope and aspect raster maps describing the DSM generated from SfM
and the ones describing the manually plotted DSM. They are read in correspondence of the pitches samples.
Weighted Average of the discrepancies between the values of the slope
raster of the roofs generated from the DSM processed through SfM
technique and the one extracted from the manually plotted DSM.
Mean values [degrees]
3.96
Median values [degrees]
4.07
Weighted Average of the discrepancies between the values of the aspect
raster of the roofs generated from the DSM processed through SfM
technique and the one extracted from the manually plotted DSM.
Mean values [degrees]
20.07
Median values [degrees]
4.60
For better assessing how much the change in slope and aspect values influence the computation of the final
global irradiation, a test was performed using only the DSM extracted from the manual plotting, which
presents a more limited noise that possibly affect the results.
Four new raster images were generated from the slope and aspect raster data describing the manually plotted
DSM, using the Raster Calculator tool of QGIS:
A slope raster increased with 5 degrees [function: slope raster + 5] (Slope+5);
A slope raster decreased of 5 degrees [function: slope raster - 5] (Slope-5);
An aspect raster increased with 5 degrees [function: aspect raster + 5] (Aspect+5);
An aspect raster decreased of 5 degrees [function: aspect raster - 5] (Aspect-5).
The value to be added or subtracted (5 degrees) was selected based on the discrepancies of the median values
between the manually plotted DSM and the SfM generated one (see Table 7).
These new maps were employed as input to generate new global irradiation maps, which were then
compared to the original one (originalGI) to assess how much each parameter influences the processing, and,
consequently, what are the tolerances in the slope and aspect values. The global irradiation maps were
generated for the day 80 (21st March). For better considering the differences also in the sun position, the
different orientations of the pitch surfaces were considered separately. In the studied case, they are: North-
East (NE), North-West (NW), South-East (SE) and South-West (SW) (Table 8).
Table 8 Comparison between the daily sums of solar radiation (global irradiation) values obtained using the
original manually plotted DSM (originalGI) and the ones obtained inputting slope and aspect raster maps
increased or decreased with 5 degrees. The solar radiation is expressed in kWh/m2/day, and the % values are
considered with respect to the average values of the originalGI.
NE
NW
SE
SW
[kWh/m2
/day]
[%]
[kWh/m
2/day]
[%]
[kWh/m2
/day]
[%]
[kWh/m
2/day]
[%]
Weighted average of
discrepancies between the
values of the originalGI
and the global irradiance
raster generated with
Slope+5
Mean
values
4.92
0.15
2.30
0.07
3.23
0.10
3.04
0.09
Median
values
4.64
0.14
1.88
0.06
5.96
0.18
3.32
0.10
Weighted average of
discrepancies between the
values of the originalGI
and the global irradiance
raster generated with
Slope-5
Mean
values
4.60
0.14
1.54
0.05
7.71
0.24
4.19
0.13
Median
values
5.42
0.17
1.96
0.06
7.30
0.22
4.08
0.13
Weighted average of
discrepancies between the
values of the originalGI
and the global irradiance
raster generated with
Aspect+5
Mean
values
1.75
0.05
1.64
0.05
9.78
0.30
0.96
0.03
Median
values
1.78
0.05
1.70
0.05
10.44
0.32
1.04
0.03
Weighted average of
discrepancies between the
values of the originalGI
and the global irradiance
raster generated with
Aspect-5
Mean
values
2.11
0.06
1.61
0.05
9.52
0.29
1.18
0.04
Median
values
2.24
0.07
1.67
0.05
9.84
0.03
1.28
0.04
As it is possible to notice in Table 8, the percentage change is very low (it is always less than 0.5%), as a
consequence of the variation of 5 degrees of both slope and aspect. This percentage should be compared with
the solar systems efficiency parameters. The tolerance of 5 degrees in the computation of slope and aspect
values can be therefore established, and this validates the possibility to employ the DSM generated through
SfM technique for performing such kind of analysis supporting the installation of solar systems. Moreover,
the computation of solar irradiance is less influenced by the variation of slope in the areas towards the west
(less than 0.1%).
Moreover, the discrepancies between the values of global irradiation processed from the manually plotted
DSM and the ones derived from the SfM DSM are computed. They are reported in Table 9. Also in this case,
the percentage change is never higher than 0.5%, confirming the results of the previous test, and verifying
the possibility to use the SfM extracted DSM for supporting solar systems installation through such analyses
in GIS. The apparent noise affecting the DSM does not influence the final results.
Table 9 Comparison between the daily sums of solar radiation (global irradiation) values obtained using the
DSM generated from the manually plotted data and the ones obtained inputting the SfM DSM. The solar
radiation is expressed in kWh/m2/day, and the % values are considered with respect to the average values of the
manually plotted DSM.
Weighted average of the discrepancies between
the mean values of the global irradiance raster of
the roofs generated from the DSM processed
through SfM technique and the one extracted
from the manually plotted DSM.
Weighted average of the discrepancies between
the median values of the global irradiance
raster of the roofs generated from the DSM
processed through SfM technique and the one
extracted from the manually plotted DSM
[kWh/m2/day]
[% with respect to the average
reference values (derived from
the manually plotted DSM)]
[kWh/m2/day]
[% with respect to the average
reference values (derived from
the manually plotted DSM)]
NE
5.74
0.18 %
3.33
0.10 %
NW
17.07
0.40 %
0.47
0.01 %
SE
15.40
0.25 %
4.29
0.07 %
SW
10.89
0.16 %
8.46
0.12 %
Finally, in order to verify whether the obtained values of solar radiation were reasonable, in terms of
numbers and trends, a comparison with the values established by the UNI 10349 (UNI, 2016) for the city of
Turin was performed. The UNI 10349 norm is the Italian version of the European standard EN ISO 15927-
6:2007 (ISO, 2007), which in turn adopts ISO 15927-6:2007 (Hygrothermal performance of buildings -
calculation and presentation of climatic data - Accumulated temperature differences). In the Italian standard,
the reference values of solar radiation are reported, together with the procedures to be used in energetic
calculations and projects.
For this test, four samples of points with the same aspect values were queried on the generated raster maps
(Figure 14). The average of the obtained values was then compared to values stipulated in the norm, as
shown in Figure 15. Here, it is clear that the computed geometry is sufficiently reliable to support such kind
of analysis about the solar radiation received by the surfaces.
Figure 14: Solar radiation analysis in June. In this analysis, the shadows related to the chimneys or other 3D
volumes are considered.
Figure 15: Graph values of the solar radiation in June.
4. CONCLUSIONS
The geometry of the roofs in an area of Turin (Italy) was analysed by means of geomatics methods in order
to automatically obtain information for supporting planning of solar systems installation, improving
renewable energy exploitation.
The generation of the 3D model was considered, employing digital photogrammetry tools and more
automatic SfM software tools, testing also open source software solutions. The 3D model produced by the
SfM software (both the OSS MicMac and PhotoScan) result to be accurate enough compared to the data
considered as ground truth (the manually plotted data), notwithstanding the higher noise of these products.
Moreover, a deeper analysis of the DSM processed through SfM technique was performed in order to assess
the reliability of the computation of solar radiation values generated by the GIS tools starting from these
input data. The DDSM generated by SfM is more noisy and, consequently, the slope and aspect raster maps
generated from this. On the one hand, this is possibly due to some interpolation procedure or disturbing
objects present in the images, and, on the other hand it is too detailed (including, for example some noise due
to the irregular surface of the pitches covered with shingles).
Notwithstanding, the statistical analysis on specific characteristics of the DSM (in particular slope and
aspect), and a specific test for assessing their tolerance, underlined how the tolerance of 5 degrees (verified
in SfM results) can be considered valid and effective for calculating the solar radiation received by the
surfaces and consequently supporting solar systems installations.
The proposed expeditious and cost-effective method for analysing the roof pitches to support solar system
installation is verified to be reliable and effective.
Non-expert users can exploit the proposed methodology, including the SfM processing of the images and the
analysis of the obtained DSM in QGIS (because a graphical model is already proposed here, but other GIS
tools and software could be equally effective). Even if some manual operations appears to be essential, a
dedicated simple tutorial about the specific operations in the software could be sufficient to guide any user to
perform the whole workflow, from the images to the radiation values computation (lasting about 3 hours).
5. REFERENCES
Ackermann, F. (1984). Digital image correlation: performance and potential application in Photogrammetry.
The Photogrammetric Record, 11(64), 429439.
Agenzia per l’Italia Digitale– Presidenza del Consiglio dei Ministri (2013), Circolare 6 dicembre 2013 n.63 -
Linee guida per la valutazione comparativa prevista dall’art. 68 del D.Lgs. 7 marzo 2005 n. 82
“Codice dell’amministrazione digitale”.
Agugiaro, G., Nex, F., Remondino, F.,De Filippi, R., Droghetti, S., and Furlanello, C. (2012). Solar radiation
estimation on building roofs and web-based solar cadastre. ISPRS Annals of the Photogrammetry,
Remote Sensing and Spatial Information Sciences, I-2, pp. 177-182. XXII ISPRS Congress.
Aicardi, I., Chiabrando, F., Grasso, N., Lingua, A.M., Noardo, F., Spanò, A. (2016). UAV photogrammetry
with oblique images: first analysis on data acquisition and processing. ISPRS International Archives
Of The Photogrammetry, Remote Sensing And Spatial Information Sciences 2016. Scopus: 2-s2.0-
84987899476 doi: 10.5194/isprsarchives-XLI-B1-835-2016.
Baltsavias, E. P. (1991). Geometrically constrained multiphoto matching, Mitteilungen, 49, Swiss Federal
Institute of Technology (ETH), Zürich, Switzerland.
Borfecchia, F., Pollino, M., De Cecco, L., Martini, S., La Porta, L., Marucci, A., and Caiaffa, E. (2013).
Integrated GIS and Remote Sensing Techniques to Support PV Potential Assessment of Roofs in
Urban Areas. Computational Science and Its Applications ICCSA 2013, pp. 422-437.
Brovelli M.A., Cina A., Crespi M., Lingua A.M., and Manzino A. (2010). Ortoimmagini e modelli
altimetrici a grande scala Linee guida, CISIS.
Bastonero, P., Donadio, E., Chiabrando, F., and Spanò, A. (2014). Fusion of 3D models derived from TLS
and image-based techniques for CH enhanced documentation. ISPRS Annals Of The
Photogrammetry, Remote Sensing And Spatial Information Sciences, 2, pp. 73-80.
Chiabrando, F., Lingua, A., Noardo, F., and Spanò, A. (2014). 3D modelling of trompe l’oeil decorated
vaults using dense matching techniques. ISPRS Annals of the photogrammetry, remote sensing and
spatial information sciences, 2, pp. 97-104.
Chiabrando, F., Lingua, A., Piras, M. (2013). Direct photogrammetry using UAV: tests and first results.
ISPRS Archives of the photogrammetry, remote sensing and spatial information sciences, XL-1, W2,
UAV-g2013, Rostock, 46 September 2013, pp. 81-86. ISSN: 2194-9034.
Deseilligny, M. P., and Clery, I. (2011). Apero, an open source bundle adjusment software for automatic
calibration and orientation of set of images. ISPRS-International Archives of the Photogrammetry,
Remote Sensing and Spatial Information Sciences, 38, 5.
Diener, S., Kiefner, M., and Dörstel, C. (2000). Radiometric normalisation and colour composite generation
of the DMC. International Archives of Photogrammetry and Remote Sensing, XXXIII, Part B1, pp.
82-88.
Dörstel, C. (2003). DMC-Practical Experiences and Photogrammetric System Performance. In: Fritsch
D.(Ed.), Photogrammetric Week 2003.
Girardeau-Montaut, D. (2011). CloudCompare-Open Source project.
Hofierka, J., Kaòuk J., and Gallay, M. (2014). The spatial distribution of photovoltaic power plants in
relation to solar resource potential: the case of the Czech republic and Slovakia. Moravian
Geographical Reports, n. 2/2014, 22, pp.26-33.
Hofierka, J., and Šuri, M. (2002). The solar radiation model for Open source GIS: implementation and
applications. Proceedings of the Open source GIS - GRASS users conference, pp. 1-19.
Kersten, T. P., and Lindstaedt, M. (2012). Automatic 3D object reconstruction from multiple images for
architectural, cultural heritage and archaeological applications using open-source software and web
services. Photogrammetrie Fernerkundung - Geoinformation, 2012(6), pp. 727-740.
Biasion A.; Dequal S.; Lingua A., (2004) A new procedure for the automatic production of true orthophotos,
International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences,
35(B4).
Marr, D., and Hildreth, E. (1980). Theory of edge detection. Proceedings of the Royal Society of London.
Series B, Biological Sciences. 207(1167), pp. 187-217.
Neteler, M., Bowman, M.H., Landa, M., Metz, M. (2012). GRASS GIS: A multi-purpose open source GIS.
Enviromental Modelling & Software, 31, Maggio 2012, pp. 124-130.
Nex, F., Remondino, F., Agugiaro, G., De Filippi, R., Poletti, M., Furlanello, C., Menegon, S., Dallago, G.,
and Fontanari, S. (2013). 3D SolarWeb: a solar cadaster in the Italian alpine landscape. International
Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, XL-7/W2.
Remondino, F., and Menna, F. (2008). Image-Based surface measurement for close-range heritage
documentation. International Archives of Photogrammetry, Remote Sensing and Spatial Information
Sciences. XXXVII, part B5-1, pp. 199-206.
Šuri, M., and Hofierka, J. (2004). A New GIS-based solar radiation model and its application to photovoltaic
assessments. Transactions in GIS, 8, pp. 175-190.
Toldo, R., Fantini, F., Giona, L., Fantoni, S., and Fusiello, A. (2013). Accurate multiview stereo
reconstruction with fast visibility integration and tight disparity bounding. International Archives of
Photogrammetry, Remote Sensing and Spatial Information Sciences, 40(5/W1), pp. 243249.
Torre, V., and Poggio, T. A. (1986). On edge detection. Pattern Analysis and Machine Intelligence, IEEE
Transactions on, (2), pp. 147-163.
UNI (2016). UNI 10349, Riscaldamento e raffrescamento degli edifici Dati climatici.
ISO (2007). ISO 15927-6:2007, Hygrothermal performance of buildings -- Calculation and presentation of
climatic data Accumulated temperature differences.
... For this, it is crucial to have a reliable 3D model. Hippenstiel et al. [44] studied the accuracy of a 3D model realized from LiDAR data, while [27] concerns 3D modeling starting from a DSM and structure using motion. In both cases, solar radiation estimation is used to evaluate the model, given the complexity it entails. ...
... This is especially relevant when looking at groups of buildings; the impact that each building has on the others is taken into account-at this scale, other elements of disturbance, such as trees, can be included in the model-together with slope and orientation in order to define, among a restricted set of alternatives, the most profitable. In this group, all the papers considering this scale [25,27,28,32,49,59,72,74,77,81] focused on a university campus. However, the number of buildings in this category of papers ranges from two and three in [49,72], respectively, to tens in [32]. ...
Article
Full-text available
In the current framework of energy transition, renewable energy production has gained a renewed relevance. A set of 75 papers was selected from the existing literature and critically analyzed to understand the main inputs and tools used to calculate solar energy and derive theoretical photovoltaic production based on geographic information systems (GISs). A heterogeneous scenario for solar energy estimation emerged from the analysis, with a prevalence of 2.5D tools—mainly ArcGIS and QGIS—whose calculation is refined chiefly by inputting weather data from databases. On the other hand, despite some minor changes, the formula for calculating the photovoltaic potential is widely acknowledged and includes solar energy, exploitable surface, performance ratio, and panel efficiency. While sectorial studies—targeting a specific component of the calculation—are sound, the comprehensive ones are generally problematic due to excessive simplification of some parts. Moreover, validation is often lacking or, when present, only partial. The research on the topic is in constant evolution, increasingly moving towards purely 3D models and refining the estimation to include the time component—both in terms of life cycle and variations between days and seasons.
... However, the studies were also performed using other photogrammetric techniques. A research team from Torino (northwestern Italy) tested the possibility to generate the data necessary for solar radiation analysis using measurements taken with a digital camera [58]. ...
Article
Full-text available
In the age of the impending climate crisis, and further forecast ecological catastrophes, humankind has begun to think with growing interest about replacing existing energy sources with renewable ones. An increasing number of people have begun to discuss the need to implement registries that collect information about the energy potential of specific parts of the environment we live in. Additionally, the simultaneous registration of installations used for obtaining energy from alternative sources is desirable. In addition to quantitative attributes, such databases should also contain comprehensive spatial information. Since, in the era of globalization, the creation of such databases ought to be standardized, the purpose of this study is to indicate the directions in which the cadastre of renewable energy sources should be developed by: (i) reviewing the solutions of renewable energy sources that have been described in the scientific literature; (ii) analyzing the content of selected geoportals containing data on renewable energy sources. The literature review was preceded by a detailed bio-metric analysis, whereas the content analysis of the geoportals led to the creation of a flow chart containing a proposal for a renewable energy source cadastre, and a ranking of the analyzed portals. Nevertheless, the conceptual work was limited to the solar cadastre only.
... Given the morphology of the village, the survey was combined using both photogrammetry survey taking pictures by a commercial UAV (Unmanned Aerial Vehicle) and an innovative laser scanner called "Leica Pegasus Backpack". Drone was used to survey whole village: this allowed to get a point cloud with a good accuracy concerning the context, the castle and roofs (Chiabrando et al., 2017). But this approach did not allow to get geometric data into narrow streets. ...
Article
Full-text available
Nowadays we are able to produce geometric models of historical building at different scale of detail using photos and measurements. More and more we are facing with lack of preservation actions and maintenance activities, bad foreseen policies, unexpected natural events, that are forcing professionals and researchers to operate without usual data. In these cases, we need consistent repository to collect and distribute data to produce information. Furthermore, we need to “give intelligence” to these repositories in order to query them with respect geometrical instances, topological issues, historical features. We dispose of tons of xyz points: how can we pass from the point cloud to a building information model, then to a geographic information system, not necessarily in this order? A simple Scan-to-BIM-to-GIS and Scan-to-GIS-to-BIM process were tested in order to consequently evaluate, with purposes of preservation and of enhancing of resilience, some practices that could became the best, also in terms of time and cost saving. The work we propose is a part of an ongoing research focused on the application of H-BIM approach for the management of historical building heritage, focused on a district management (H-DIM, at an urban level). In particular, with regard to the resilience theme, both the acquisition phase and the archive research process are of great importance for protecting our undefended building heritage. Regarding the case study of the paper, UNESCO sites represent important areas for collective interests of humanity. This contribution proposes a possible solution applying a digital cultural heritage to the historical part of the Municipality of Serralunga d’Alba belonging to the UNESCO site called Vineyard Landscape of Langhe-Roero and Monferrato.
Article
Full-text available
In recent years, many studies revealed the advantages of using airborne oblique images for obtaining improved 3D city models (e.g. including façades and building footprints). Expensive airborne cameras, installed on traditional aerial platforms, usually acquired the data. The purpose of this paper is to evaluate the possibility of acquire and use oblique images for the 3D reconstruction of a historical building, obtained by UAV (Unmanned Aerial Vehicle) and traditional COTS (Commercial Off-the-Shelf) digital cameras (more compact and lighter than generally used devices), for the realization of high-level-of-detail architectural survey. The critical issues of the acquisitions from a common UAV (flight planning strategies, ground control points, check points distribution and measurement, etc.) are described. Another important considered aspect was the evaluation of the possibility to use such systems as low cost methods for obtaining complete information from an aerial point of view in case of emergency problems or, as in the present paper, in the cultural heritage application field. The data processing was realized using SfM-based approach for point cloud generation: different dense image-matching algorithms implemented in some commercial and open source software were tested. The achieved results are analysed and the discrepancies from some reference LiDAR data are computed for a final evaluation. The system was tested on the S. Maria Chapel, a part of the Novalesa Abbey (Italy).
Conference Paper
Full-text available
The last guidelines approved by Italian government to financially support the solar Photovoltaic (PV) Energy production development (Fourth and Fifth feed-in-scheme, January 2012 and later), in order to avoid soil consumption in agricultural or naturals areas, include specific indications for more advantageously funding installations exploiting roofs or covers surfaces. In this context it becomes important, for a suitable PV planning and monitoring, the extensive mapping of the available surfaces extent, usually corresponding to covers and properly assessing their quality in term of PV potential. Since the covers are mainly located in urban or industrial areas, whose 3D heterogeneity, albedo, atmospheric turbidity and casting shadows significantly influence the local solar irradiance, it is necessary to suitably account for these distributed factors by means of GIS mapping and advanced modeling tools in order to provide realistic estimates of solar available radiance at roofs level. The implemented methodology, based on remote sensing techniques, has allowed to estimate and map the global solar radiance over all the roofs within Avellino (southern Italy) municipality. Starting from LIDAR data, DSM of the entire area of interest (~42 Km2) has been firstly obtained; then the 3D model of each building and related cover has been derived. To account the atmospheric transparency and the related time-dependent diffuse/direct radiation percentage on the area, data and tools from EU PVGIS web application have been also used. The final processing to obtain the solar radiance maps has been carried out using specific software modules available within commercial and open-source GIS packages.
Article
Full-text available
In recent years, the quality of high resolution acquisition platforms for geomatic applications has decidedly increased, especially in the performance of the sensors devoted to image acquisition. The small size of these new sensors combined with the increase in resolution allows them to be easily mounted onto Unmanned Aerial Vehicles (UAVs); in particular, calibrated, very-high-resolution digital cameras for photogrammetric purposes such as digital terrain model (DTM) and digital surface model (DSM) extraction, orthophotos, and map realization have been used. In this case, the UAV performance allows a high quality product to be obtained, considering the pixel size and the accuracy of the DTM/DSM which could be obtained with automatic procedures. Several navigation sensors (GPS/GNSS and IMU-MEMS) are embedded into UAVs in order to realize autonomous flight. The quality of these sensors, in terms of accuracy, depends on the model of UAV and its purpose. The navigation solution (position and attitude) is estimated by the internal UAV sensor and can be employed to directly georeference the images, in order to produce an quick and easy description and analysis of the overlooked area. This is a good condition for semi-automatic procedures using a bundle-block photogrammetric approach. But is it possible to realize a direct photogrammetry? And what are the limits? Several tests were carried out over different areas and in different conditions using three different UAVs belonging to the Geomatics group of the Politecnico di Torino. In this paper, an investigation of the limits of some commercial UAVs is reported, defining a dedicated procedure to valuate their performance, especially considering the use of UAVs for direct photogrammetry.
Article
Full-text available
Over the last few years, many European countries experienced a rapid growth of photovoltaic (PV) power plants. For example, more than 20,000 new PV power plants were built in the Czech Republic. The high spatial and temporal variability of the solar resource and subsequent PV power plant production, poses new challenges for the reliability and predictability of the power grid system. In this paper, we analyse the most recent data on PV power plants built in the Czech Republic and Slovakia, with a focus on the spatial distribution of these installations. We have found that these power plants scarcely follow the solar resource potential and, apparently, other factors affect decisions for their location. Recent changes in the support schemes for solar applications also influence these patterns, with new installations mostly confined to built-up areas. These changes will require new tools to assess the appropriate locations of PV systems.
Article
Full-text available
The aim of this study is the estimation of solar irradiance on building roofs in complex Alpine landscapes. Very high resolution geometric models of the building roofs are generated by means of advanced automated image matching methods. Models are combined with raster and vector data sources to estimate the incoming solar radiation hitting the roofs. The methodology takes into account for atmospheric effects, site latitude and elevation, slope and aspect of the terrain as well as the effects of shadows cast by surrounding buildings, chimneys, dormers, vegetation and terrain topography. An open source software solution has been developed and applied to a study area located in a mountainous site and containing some 1250 residential, commercial and industrial buildings. The method has been validated by data collected with a pyranometer and results made available through a prototype WebGIS platform.
Article
Full-text available
Dense matching techniques, implemented in many commercial and open source software, are useful instruments for carrying out a rapid and detailed analysis of complex objects, including various types of details and surfaces. For this reason these tools were tested in the metric survey of a frescoed ceiling in the hall of honour of a baroque building. The surfaces are covered with trompe-l’oeil paintings which theoretically can give a very good texture to automatic matching algorithms but in this case problems arise when attempting to reconstruct the correct geometry: in fact, in correspondence with the main architectonic painted details, the models present some irregularities, unexpectedly coherent with the painted drawing. The photogrammetric models have been compared with data deriving from a LIDAR survey of the same object, to evaluate the entity of this blunder: some profiles of selected sections have been extracted, verifying the different behaviours of the software tools.
Article
Full-text available
Recognizing the various advantages offered by 3D new metric survey technologies in the Cultural Heritage documentation phase, this paper presents some tests of 3D model generation, using different methods, and their possible fusion. With the aim to define potentialities and problems deriving from integration or fusion of metric data acquired with different survey techniques, the elected test case is an outstanding Cultural Heritage item, presenting both widespread and specific complexities connected to the conservation of historical buildings. The site is the Staffarda Abbey, the most relevant evidence of medieval architecture in Piedmont. This application faced one of the most topical architectural issues consisting in the opportunity to study and analyze an object as a whole, from twice location of acquisition sensors, both the terrestrial and the aerial one. In particular, the work consists in the evaluation of chances deriving from a simple union or from the fusion of different 3D cloud-models of the abbey, achieved by multi-sensor techniques. The aerial survey is based on a photogrammetric RPAS (Remotely piloted aircraft system) flight while the terrestrial acquisition have been fulfilled by laser scanning survey. Both techniques allowed to extract and process different point clouds and to generate consequent 3D continuous models which are characterized by different scale, that is to say different resolutions and diverse contents of details and precisions. Starting from these models, the proposed process, applied to a sample area of the building, aimed to test the generation of a unique 3Dmodel thorough a fusion of different sensor point clouds. Surely, the describing potential and the metric and thematic gains feasible by the final model exceeded those offered by the two detached models.
Conference Paper
Full-text available
The paper presents the research carried out in the on-going 3DSolarWeb project to test and implement a complete pipeline for the generation of a solar cadastre of building roofs located in alpine areas. The project aims at providing reliable results in a costeffective way, using (low resolution) available data and new aerial imagery acquisitions as input. The environmental context is digitally represented using already existing low resolution LiDAR data (1–2 m resolution), while the urban area is modelled using high resolution aerial images (10–20 cm GSD) and photogrammetric DSM. Reliable models and algorithms for the estimation of the incoming sun radiance are then adopted and a WebGIS is set up for the interactive calculation of the photovoltaic (PV) potential in a raster-based form. The paper summarizes the entire pipeline and the results (Figure 1) achieved on the test areas to show the potentialities of the method and the web-based service.