Two previous articles discussed how the acceptable daily exposure (ADE) of a compound and the process capability (Cpu) of its cleaning process can be used to assess the level of risk associated with cross contamination in shared facilities. This article will discuss how the maximum safe surface residue (MSSR) can be combined with the visual residue limit (VRL) to assess the acceptability of visual inspection for detecting the possibility of compound carryover in shared facilities. Combined with the ADE-derived toxicity scale and Cpu-derived probability scale, this new detectability scale can provide for a total measure of risk, and this new scale can also assist in determining whether visual inspection is acceptable for use in cleaning validation or verification.
Content may be subject to copyright.
An MSSR-Derived Scale For Assessing Detectability Of Visual Inspection
By Andrew Walsh; Thomas Altmann; Alfredo Canhoto, Ph.D.; Ester Lovsin Barle, Ph.D.; David G. Dolan, Ph.D.; Andreas Flueckiger, M.D.; Igor
Gorsky; Robert Kowal; Mariann Neverovitch; Mohammad Ovais; Osamu Shirokizawa; and Kelly Waldron
Part of the Cleaning Validation For the 21 Century series
Two previous articles discussed how the acceptable daily exposure (ADE) of a compound and the
process capability (Cpu) of its cleaning process can be used to assess the level of risk associated with
cross contamination in shared facilities. This article will discuss how the maximum safe surface
residue (MSSR) can be combined with the visual residue limit (VRL) to assess the acceptability of
visual inspection for detecting the possibility of compound carryover in shared facilities. Combined
with the ADE-derived toxicity scale and Cpu-derived probability scale, this new detectability scale
can provide for a total measure of risk, and this new scale can also assist in determining whether
visual inspection is acceptable for use in cleaning validation or verification.
Selection Of Analytical Methods In Cleaning
The analytical methods typically used in cleaning validation fall into two broad categories: specific methods and nonspecific methods. The decision to use
a specific or nonspecific method should be science- and risk-based. For example, total organic carbon analysis (TOC) has been a method of choice for
proteins due to its ease of use, the high carbon content of proteins, and the physiochemical difficulties in using specific methods such as enzyme-linked
immunosorbent assay (ELISA).
In general, visual inspection would be considered a foundation method, and therefore always required. It would be supported next by TOC, conductivity,
and other nonspecific methods or by more specific methods as necessitated by the risk level. Figure 1 illustrates this risk-based hierarchy of analytical
methods. Particularly for low-risk situations (e.g., low-hazard compounds and easily inspected equipment), visual inspection could be the sole method
used for release of equipment after cleaning for return to manufacturing (which it typically is after successful cleaning validation studies). Visual
inspection can also complement other methods such as TOC or conductivity to provide additional documentation for the release of equipment after
cleaning. Finally, in high-risk situations, specific methods such as HPLC, LC/MS, etc., may need to be used along with, as always, a visual inspection.
Figure 1 presents a hierarchy for selecting analytical methods for cleaning based on the ADE-derived toxicity scale. As the level of the hazard increases,
the rigor required of the analytical method should increase. However, as indicated by the question marks, the transitions from using simple visual
inspection to needing TOC, conductivity, etc., and from there to needing specific methods are not clear. The use of the scale based on visual detection
limits discussed in this article may provide a tool to help resolve this question for visual inspection.
Figure 1: Risk hierarchy of analytical methods (Note: Toxicity Scale is based on –log(ADE) where ADE is the Acceptable Daily Exposure in grams)
Detection Limits For Visual Inspection
While the potential for using visual inspection in the validation of cleaning was proposed by Doug Mendenhall as long ago as 1989, there have not been
many actual studies performed or publications on using it. In 1993, Fourman and Mullen published an article on cleaning validation acceptance limits
where they stated:
Guest Column | December 11, 2017
st
1,2
1 2
1
3
4
Spiking studies have determined that the active ingredients in most products are visible at approximately 100µg per 2 X 2 in. swab area.
This single sentence has somehow become a de facto industry standard in the minds of many industry workers, although no data or any information
other than the sentence quoted above was provided by the authors. The "100µg per 2 X 2 in. swab area" translates into 4µg/cm , and it is the 4µg/cm
value that is most frequently quoted, although that's not what was actually written in the article. Shortly after, in 1994, Jenkins and Vanderwielen stated
that the VRL (visual residue limit) could be reduced to 1µg/cm if a light source is used during the inspection. In 1998, two workers at Bristol-Myers
Squibb published an article referencing a study where they had used visual inspection as the sole method for solid dosage packaging equipment. In
2004, Richard Forsyth and coworkers at Merck started publishing a series of articles in which they claimed that VRLs for APIs and common excipients
could be seen down to 2µg/cm and even as low as 1µg/cm . These studies used a "spotting" technique to apply the residues, which may have made the
residues easier to see. However, based on the results of only four observers in their initial article, they concluded that visual inspection had many
challenges making it difficult to justify. More recently, Forsyth published an article on the logistical difficulties involved in qualifying a large group of
personnel without knowing the VRLs of the products. A statistical study by Mohammad Ovais in 2010 demonstrated that the VRL could be determined
using logistic regression analysis of the inspection data. Subsequently, a series of studies using large numbers of observers was performed at Stevens
Institute of Technology from 2011 to 2013, employing an "even coating" technique that found VRLs for one particular product to range from 3
to7µg/cm , which were found to be dependent on training.
While there is not a lot of supporting data at this point in time, it appears reasonable to say that the VRL for the majority of products, under the majority
of viewing conditions, probably lies somewhere between 1 and 10µg/cm , depending on the product, type of surface (so far only stainless steel has been
evaluated), the training of the inspectors, the preparation of the test coupons, and possibly the environmental conditions of the inspection.
If it is truly the case that the majority of drug product residues on equipment can be discerned by visual inspection in the range of 1 to 10µg/cm , then
equipment could be released after cleaning, and cleaning procedures could even be validated, using only visual inspection as long as the MSSR levels
were safely above this range. If the MSSRs are set too low using arbitrary limits, then visual inspection would be harder to justify, limiting its usefulness.
Impact Of 1/1,000th Dose And 10ppm Limits On The Use of Visual Inspection
A recent article examined 304 drugs from several companies and compared their ADEs to their corresponding 1/1,000th of the lowest therapeutic dose.
This article revealed that the limits calculated by the 1/1,000th were not low enough in about 15 percent of the cases and were too low in 85 percent of
the cases – by as much as 10x, 100x and, in a few cases, over 1,000x (Figure 2).
Figure 2: Comparison of ADEs to the 1/1,000th dose
The cases where the ADEs were 85 percent higher are very significant to this discussion, as this is where continuing the use of the 1/1,000th or 10ppm
will preclude the use of visual inspection in many of these cases, especially if both are used in combination.
To illustrate the impact that the 1/1,000th or 10ppm limits have on the use of visual inspection, the MSSRs were calculated for the 304 ADEs and their
corresponding 1/1,000th limit using the following assumptions:
Table 1: Parameter Values Used For Calculations
The MSSR (Maximum Safe Carryover/Total Equipment Surface Area) was calculated.
2 2
2 5
6
2 2
7
8
9
2 10
2
2
11
The data obtained was then plotted using R statistical software and, just as in the previous article, the data had to be plotted on a log scale in order to
visualize it all on one graph. The results can be seen in Figure 3.
Figure 3: Comparison of ADE, 1/1,000th and 10ppm to visual residue limits (10µg/cm )A line has been drawn at the 10µg/cm level for the VRL.
Obviously, many of these compounds could not be considered for evaluation by visual inspection as the MSSRs based on the 1/1,000th dose or 10 ppm
are below the VRL or too close to it to be justified as a safe method of analysis. However, if only the ADE is used to calculate the MSSRs, then many of
these compounds could easily be considered for evaluation by visual inspection (Figure 4).
Figure 4: Drug products where ADE can meet visual residue limits (10µg/cm )It would seem that the compounds on the right side of the curve in the
rectangle could easily be justified for evaluation by visual inspection. But as we move to the left and the MSSRs get closer and closer to the 10µg/cm
VRL, it would seem harder to justify evaluation by visual inspection (Figure 5).
Figure 5: Where is visual inspection appropriate to use?
Would it not be helpful to have some way of judging how close the MSSR is to the VRL and whether it is acceptable to use?
Using MSSR As A Measure Of Detectability
11
22
2
2
Since we are trying to measure how close the MSSR is to the VRL so we can make a decision on whether we can use visual inspection, a simple method to
measure the relative distance regardless of what the MSSRs or the VRLs happen to be is to look at the ratio of the two values. If we then take the log of
this ratio we can obtain a logarithmic scale that equals "0" when the values of the MSSR and VRL are equal and becomes negative when the VRL is lower
than the MSSR and positive when it is higher. This calculation would provide us with a visual detection index that could be applied across all
manufacturing situations (Equation 1):
Table 2 shows the range of VDIs for different MSSRs based on VRLs of 5ug/cm and 10µg/cm .
Table 2: Example Of Visual Detection Index Scales For Different MSSRs And VRLs
In this example, any VDI above 0 is unacceptable, with VDIs below -1.0 being acceptable. A VDI of 0 can be considered the "vanishing point" where an
MSSR equals its VRL and is about to pass below it. Consequently, each company could select how close to a VDI of 0 it believes is justifiable before
allowing visual inspection to be used. For example, one company may require all its VDIs to be < -2.0, or at least 2 logs below this vanishing point.
Discussion
The selection of methods for assessing cleaning should be science-based and risk-based. Risks to consider in the risk assessment can include the hazard
or risk of the process residue to be analyzed (toxicity score), level of detection required, applicability of existing methods, other quality and compliance
risks, as well as risks to the business, such as difficulty of implementation and the possible long-term maintenance of the method for ongoing monitoring
programs. A reasoned and logical approach needs to be taken, as some methods may be unnecessarily expensive or difficult to implement for the process
residues under consideration. Conversely, a simple, inexpensive method may not be appropriate for all process residues. In general, the simplest
techniques should be examined first and used if determined to be appropriate through an assessment based on science and risk. Ultimately, the goal
should be to use the simplest technique that is appropriate and can be justified. Visual inspection could be the sole method if properly justified based on
risk.
As noted in a previous article on visual inspection, U.S. regulation 21 CFR 211.67 (b) (6) has required the "inspection of manufacturing equipment
immediately before use" since 1979 and, in practice, pharmaceutical manufacturers have been releasing equipment based on a “visual" inspection for
many years. Subsequently, the industry and even regulators have come to see this "inspection" as a "visual inspection" requirement. For example, the
Pharmaceutical Inspection Co-operation Scheme (PIC/S) recommends “no quantity of residue should be visible on the equipment after cleaning
procedures are performed.” Similar statements can be found in many of the regulatory guidances on cleaning. PIC/S also mentions "spiking studies
should determine the concentration at which most active ingredients are visible.”
Recently, it appears that regulators are open to the possible use of visual inspection for cleaning validation. The draft of Annex 15 in Paragraph 9.2
originally stated:
A visual check for cleanliness may form an important part of the acceptance criteria for cleaning validation however, it is not acceptable for
this criterion alone to be used.
However, after comments from industry stakeholders, in the final version of Annex 15 Paragraph 10.2 this was changed to:
A visual check for cleanliness is an important part of the acceptance criteria for cleaning validation. It is not generally acceptable
for this criterion alone to be used.
2 2
1 2-4
It should be noted that Annex 15 is used by PIC/S, which has 49 health authorities as members, including the FDA, which joined PIC/S in January of
2011. So, it appears that most of the world's health authorities are ready to accept visual inspection for cleaning validation under the right circumstances
and justification. The question, of course, is under what circumstances and justification.
This new detectability scale for visual inspection can be used in conjunction with the ADE-derived toxicity scale and the Cpu-derived probability scale
as tools to evaluate the level of risk in cleaning validation. Going further, the toxicity scale could also help define the circumstances for visual inspection
(a low hazard) and the detectability scale can provide the justification (easy to see at levels well below the safe limit for that hazard). This has the
potential to help justify visual inspection in clinical manufacturing or R&D areas where there are limited amounts of API available for analytical method
development and help speed and simplify the introduction of new compounds in a safe manner.
To move forward on implementing visual inspection as a method for cleaning validation, we believe it will be important to develop and maintain a formal
visual inspection program, including justification through risk assessments, training and qualification of operators and inspectors, and with periodic
assessments to ensure the integrity of the program. Future articles will examine the implementation of visual inspection in both clinical and commercial
manufacturing environments.
A subsequent article will discuss how another detectability scale can be developed using total organic carbon detection limits and TOC swab limits, and a
final article will discuss how all these new scales can be used together to create a cleaning risk dashboard and how they can also be used for scoring
cleaning FMEAs (failure modes and effects analyses)/FMECAs (failure mode effects and criticality analyses) of cleaning processes.
Peer Reviewers: Sarra Boujelben; Gabriela Cruz, Ph.D.; Mallory DeGennaro; Parth Desai; Ioanna-Maria Gerostathi; Miquel Romero Obon; Joel
Young; and Ersa Yuliza
References:
1. Walsh, Andrew, Ester Lovsin Barle, Michel Crevoisier, David G. Dolan, Andreas Flueckiger, Mohammad Ovais, Osamu Shirokizawa, and Kelly
Waldron, "An ADE-Derived Scale For Assessing Product Cross-Contamination Risk In Shared Facilities," Pharmaceutical Online, May 2017.
2. Walsh, Andrew, Ester Lovsin Barle, David G. Dolan, Andreas Flueckiger, Igor Gorsky, Robert Kowal, Mohammad Ovais, Osamu Shirokizawa, and
Kelly Waldron, "A Process Capability-Derived Scale For Assessing Product Cross-Contamination Risk In Shared Facilities," Pharmaceutical Online,
August 2017.
3. Mendenhall, D., “Cleaning Validation,” Drug Development and Industrial Pharmacy, 15(13), pp. 2105-2114, 1989
4. Fourman, G.L., and Mullen, M.V., "Determining Cleaning Validation Acceptance Limits for Pharmaceutical Manufacturing Operations,"
Pharmaceutical Technology, 1993, Vol. 17, No. 4, pp 54-60.
5. Jenkins K.M. and A.J. Vanderwielen, "Cleaning Validation: An Overall Perspective", Pharm. Technol. 18 (4), 60–73 (1994).
6. Alvey, A. P., and Carrie, T.R. "Not Seeing is Believing — A Non-Traditional Approach for Cleaning Validation," Journal of Validation Technology,
May 1998, Vol. 4, Issue 3.
7. Richard J. Forsyth, Vincent Van Nostrand, and Gregory P. Martin, "Visible-Residue Limit for Cleaning Validation and its Potential Application in
Pharmaceutical Research Facility," Pharmaceutical Technology, Oct. 02, 2004.
8. R. Forsyth, "Qualifying Personnel to Visually Inspect Cleaned Equipment Part II: Small vs. Large Group Training," Pharmaceutical Technology 40
(6) 2016.
9. Ovais, Mohammad, "Statistically Justifiable Visible Residue Limits," Pharmaceutical Technology, 2010, Volume 34, Number 3.
10. Desai, Parth and Andrew Walsh, "Evaluation of Visual Inspection for use in Cleaning Validation - Part I,” Pharmaceutical Online, September 2017.
11. Walsh, Andrew, Michel Crevoisier, Ester Lovsin Barle, Andreas Flueckiger, David G. Dolan, and Mohammad Ovais, "Cleaning Limits—Why the 10-
ppm and 0.001-Dose Criteria Should be Abandoned, Part II," Pharmaceutical Technology, 40 (8), 45-55 (2016).
1 2
... The visual residue limit (VRL) to assess the acceptability of visual inspection for detecting the possibility of substance carryover in shared facilities for the majority of products, under the majority of viewing conditions is considered to range between 1 and 10 μg/cm 2 (Walsh et al., 2017 and as food additives (generally at levels many times greater than those in drugs) for years, and it therefore is reasonable to consider these substances as presenting a low-risk to patients or workers in pharmaceutical manufacturing. With both guidance documents, resources (e.g., auditing efforts, exposure controls, and others) can be better focused on substances of concern as the risks for using these materials are very low and do not warrant the regular type of review (IPEC, 2015). ...
... A visual check for cleanliness is generally not acceptable by regulators, to be used as criterion alone. Therefore, additional sampling methods (swab tests, TOC) should be in place, depending on science-based and risk-based considerations in the manufacturing process(Walsh et al., 2017). Only rare cases (e.g., very low batch size) would lead to Maximum Safe Surface Residue (MSSR) limits, which range below the VRL, when applying high PDE values of 50 mg/day.As mentioned above, this is not the first attempt in establishing a framework for the identification of hazardous and nonhazardous substances. ...
Article
Contract Development and Manufacturing Organizations (CDMOs) that manufacture large, diverse portfolio of chemical and pharmaceutical substances require pragmatic risk‐based decisions with respect to the safe carry‐over between different chemical entities, as well as for worker protection. Additionally, CDMOs may not have access to primary study data or data is generally lacking for a specific substance. While pharmaceuticals require the establishment of health‐based exposure limits (HBELs) (e.g., occupational exposure limits, permitted daily exposure limits), the limits for non‐hazardous substances could be set in a protective and pragmatic way by using default values, when internally required. Since there is no aligned definition provided by authorities, nor agreed default values for non‐hazardous substances, we provide a decision tree in order to help qualified experts (such as qualified toxicologists) to identify the group of non‐hazardous substances and to assign default HBEL values for specific routes of exposure. The non‐hazardous substances discussed within this publication are part of the following subgroups: (I) inactive pharmaceutical ingredients, (II) pharmaceutical excipients or cosmetic ingredients, (III) substances Generally Recognized as Safe (GRAS), and (IV) food ingredients, additives and contact materials. The proposed default limit values are 1 mg/m3 for the OEL, and 50 mg/day for the PDE oral and IV (intravenous) route. Contract Development and Manufacturing Organizations (CDMOs) work with a large, diverse portfolio of pharmaceutical substances, thus, often need a pragmatic approach to apply risk‐based decisions for patient and worker safety during manufacturing in multi‐purpose facilities. This work provides guidance on identifying and setting default health‐based exposure limits (HBELs) for defined non‐hazardous substances in pharmaceutical manufacturing in line with regulatory guidelines.
... Then, SRLs were set as acceptable residue levels in 100 cm 2 usually used in swab testing (formula 7). The example values of batch size (BS), maximum daily dose (MDD), and example shared surface area shown in Walsh et al. (2017) were used for the SRL calculations in this study. ...
Article
Allergic contact dermatitis is a common occupational and environmental health problem and setting of health-based exposure limits (HBELs) to prevent induction of skin sensitization is strongly desired. When manufacturing pharmaceuticals in a shared facility, cleaning validation using surface residue levels (SRLs) derived from permitted daily exposures (PDEs) is conducted to avoid cross-contamination from the perspective of protecting patients; however, it is unclear whether the SRLs are sufficient to prevent induction of skin sensitization for workers as well. In this study, we compared acceptable surface limits (ASLs) derived from acceptable exposure levels (AELs) based on EC1.6 obtained from local lymph node assay (LLNA): BrdU-ELISA for occupational risk management of skin sensitizers with PDE-based SRLs. ASLs for 1,4-phenylenediamine (GHS skin sensitization sub-category 1A), isoeugenol (sub-category 1A), and methyl methacrylate (sub-category 1B) were compared with SRLs based on the PDEs derived from their systemic effects. The results yielded an SRL for 1,4-phenylenediamine (PDE: 0.8 mg/day) of 30 mg/100 cm², almost 1,000 times higher than ASL (0.031 mg/100 cm²) derived from its skin sensitization potency. SRL for isoeugenol (PDE: 3.1 mg/day) was 130 mg/100 cm², over 500 times higher than ASL (0.18 mg/100 cm²). For methyl methacrylate (PDE: 5 mg/day) as well, SRL (200 mg/100 cm²) was higher, but it was within 20 times the ASL (10 mg/100 cm²). These results showed that ASL-based risk management is extremely important especially for strong sensitizers classified as GHS sub-category 1A for occupational skin sensitization risk management.
Article
Full-text available
This article reviews the European Medicines Agency (EMA) April 16, 2018 Questions and answers on implementation of risk-based prevention of cross-contamination in production and Guideline on setting health-based exposure limits for use in risk identification in the manufacture of different medicinal products in shared facilities. The article discusses the significance of these changes to cleaning validation programs and how they compare to the new ASTM E3106-18 Standard Guide for Science-Based and Risk-Based Cleaning Process Development and Validation and the forthcoming ASTM Standard Guide for the Derivation of Health-Based Exposure Limits (HBELs).
Article
Full-text available
Part of the Cleaning Validation for the 21st Century series U.S. Regulation 21 CFR 211.67 (b) (6) has required the "inspection of manufacturing equipment immediately before use" since 1979. In practice, pharmaceutical manufacturers have been releasing equipment based on a " visual" inspection for many years. Subsequently, the industry and even regulators have come to see this "inspection" as a "visual inspection" requirement. For example, the Pharmaceutical Inspection Cooperation Scheme (PIC/S) recommends " no quantity of residue should be visible on the equipment after cleaning procedures are performed. " 1 Similar statements can be found in many of the regulatory guidances on cleaning. PIC/S also mentions "spiking studies should determine the concentration at which most active ingredients are visible. " There have been only a few studies on visual inspection (VI). In 1993, Gary Fourman and Dr. Mike Mullen of Eli Lilly published an article in which they mentioned that spiking studies indicated many compounds were visible at approximately 100 µgrams/4 inch (or 4 µgrams/cm). No details were provided on how the studies were performed or on what compounds. A year later, an article by Jenkins and Vanderwielen claimed to be able to see residues down to 1 µgrams/cm by using an additional light source. Six years later, in 2000, Frank Buscalferri et al, published an article where they claimed to see residues of several compounds down to approximately 0.4 µgrams/cm. Then, from 2004 to 2014, Richard J. Forsyth, along with several others, published a series of articles that found a range of 0.4 to >10 µgrams/cm for several different compounds. The basic approach for conducting these VI studies has been " spotting " a known amount of residue onto a "coupon" or surrogate material surface. Analysts then observed the spiked surface under various specified viewing conditions, and the lowest amount of residue that all analysts could see was considered the visual detection limit (VDL) for that compound/product. However, it has never been clear whether VI is reliable since it has never actually been validated. If VI can be validated, or qualified, then the use of this technique for release of equipment would be justified and might even be used in place of traditional swab methods, which take substantial amounts of time and resources to develop, validate, and perform. As mentioned, the above approach used a " spotting " technique that may result in an easily visible deposit. There has been a question of whether actual residues typically deposit all in one spot. Another possible approach is to apply an even coating of residue on the material surface and see if analysts can see these residues at the same levels. If analysts could, that could lead to the validation of VI as an analytical method.
Article
Full-text available
This article will present a new scale based on the process capability of a cleaning process that can be used to evaluate the probability of cross-contamination by compounds manufactured in a shared facility or equipment train. This approach can be used to evaluate sample results from cleaning validations or monitoring studies for all types of cleaning, including manual, semi-automated, or automated cleaning
Article
Full-text available
This article discusses how to derive a Toxicity Scale from the ADE (with scores form 1-10) and how the ADE of any compound can be directly converted into a score on this scale. This Toxicity Scale can be used to quickly assess the potential for the risk of cross contamination in manufacturing situations through an easy to use visual scale. This Toxicity Scale can be used as the "Severity" Score in FMEAs of Cleaning Processes.
Article
Full-text available
This article discusses how the 10ppm limit, along with the 0.001 dose limit, are not truly risk-based approaches and are also unsound from an operational standpoint as they have caused unnecessary difficulties for many companies. A statistical process-based approach to demonstrate that acceptable cleaning has been achieved compared to a health-based limit is proposed.
Article
Full-text available
Current methods for establishing visible residue limits (VRLs) are not statistically justifiable. The author proposes a method for estimating VRLs based on logistic regression.
Article
Evaluations have shown that, in most cases, visual observations are sensitive enough to verify equipment cleanliness. An experiment was conducted to explore the possibility of using a visible-residue limit as an acceptable cleaning limit in a pharmaceutical research facility, including an evaluation of the iimits and subjectivity of "visually clean" equipment.
Determining Cleaning Validation Acceptance Limits for Pharmaceutical Manufacturing Operations
  • G L Fourman
  • M V Mullen
Fourman, G.L., and Mullen, M.V., "Determining Cleaning Validation Acceptance Limits for Pharmaceutical Manufacturing Operations," Pharmaceutical Technology, 1993, Vol. 17, No. 4, pp 54-60.