Hydrocarbons can be interesting refrigerants in domestic facilities such as heat pumps for domestic hot water production called heat pump water heaters (HPWH). However, due to flammability and submission to severe regulations, the use of hydrocarbons requires improvements in design and optimisation of components to reduce the refrigerant charge. This paper first reviews the regulations applied to hydrocarbon technologies then discusses possibilities of charge reduction for a R290 HPWH. Mainly by selecting condensers with high thermal efficiency and low internal volume, the charge may be reduced to extremely low levels. Using the same base of refrigerating system, three types of condensers were tested: tank-wrapped D-tube, roll-bond and microchannel heat exchangers. The D-tube has a low compactness. Microchannels are penalised by the diameter of their distributors. The best performance is obtained by the roll-bond HPWH with a charge of 224 g: COP of 3.17 and heating time under 7 h.
Content may be subject to copyright.
A preview of the PDF is not available
... Many experimental, analytical, and numerical studies have focused on the performance of heat pumps and refrigeration systems when using hydrocarbons as refrigerants [8][9][10][11][12]. These studies examine the use of hydrocarbons in their pure forms or mixed with HFCs or HFOs. ...
... The total and specific exergy of a fluid were calculated using Equations (10) and (11), respectively [26]: ...
Article
Full-text available
The phase-down of hydrofluorocarbons and substitution with low global warming potential values are consequences of the awareness about the environmental impacts of greenhouse gases. This theoretical study evaluated the energy and exergy performances and the environmental impact of three vapor compression system configurations operating with the hydrocarbons R290, R600a, and R1270 as alternatives to R134a. The refrigeration cycle configurations investigated in this study include a single-stage cycle, a cycle equipped with an internal heat exchanger, and a two-stage cycle with vapor injection. According to the results, the alternative hydrocarbon refrigerants could provide comparable system performance to R134a. The analysis results also revealed that using an internal heat exchanger or a flash tank vapor injection could improve the system's efficiency while decreasing the heating capacity. The most efficient configuration was the two-stage refrigeration cycle with vapor injection, as revealed by the exergy analysis. The environmental impact analysis indicated that the utilization of environmentally-friendly refrigerants and improving the refrigeration system's efficiency could mitigate equivalent CO2 emissions significantly. The utilization of hydrocarbons reduced the carbon footprint by 50%, while a 1% to 8% reduction could be achieved using the internal heat exchanger and flash tank vapor injection.
Article
The ambition of zero emission neighborhood has been set out to operate the building components with zero life cycle greenhouse gas emissions. Hydrocarbon heat pumps as the building components with nearly zero greenhouse gas emissions are faced with the problem of simultaneously reducing refrigerant charges and maintaining competitive capacities. These must be resolved by formulating an effective modeling tool for detailed design and optimization. To develop a resistance–capacitance network model, interdisciplinary knowledge (including graph theory, heat and mass transfer, local moving boundary modeling, and algebraic multigrid) is integrated. The model simultaneously considers heat exchanger circuitries with a high detail level and component behaviors at a holistic system level. Based on experimental validation, the model’s error is ∼ 10%. In an R290 heat pump case study, the coupling mechanism of the system’s configuration, working conditions, and refrigerant distribution are analyzed. Results indicate that the refrigerant charge can be reduced by 11.6% at the expense of a 4.2% reduction in the coefficient of performance, by varying the compressor displacement alone. In response to the variation in the system’s refrigerant, 46.8%, 7.85%, and 44.2% of the total amount of refrigerants are allocated to the condenser, evaporator, and compressor, respectively. The distribution of the refrigerant quality in the heat exchanger is also visualized to indicate the direction of refrigerant reduction.
Article
Recently, natural refrigerants have gained a significant attention as a future alternative because of their performance and environmentally friendly characteristics; No Ozone Depleting Potential and near zero Global Warming Potential. The present paper reports an experimental study performed with refrigeration systems developed using one of natural refrigerants, R-290 (Propane & GWP=3), particularly with the limited charge amount to meet the most stringent regulatory requirement, IATA - Dangerous Goods Regulation. Under IATA regulation, refrigerating machines and components containing flammable gas are forbidden for international air freight unless the flammable charge shall be less than 100g. Two types of standalone system were developed, so called Liquid Circulating Chiller and Air-Air Cooler. Both were with air-cooled condensers. Liquid Circulating Chiller consisted of a liquid cooled evaporator while Air-Air Cooler came with an air-cooled evaporator. All component selections were made to achieve the minimum refrigerant charge and as a result, the total system charge was kept around 100g or less. During the system development, several combinations of the components were considered (e.g., compressors and heat exchangers), and system developed was tested under various test conditions as a part of the system optimization. From the study, the maximum cooling capacity achieved was around 3kW with less than 100g of R-290 refrigerant charge.
Article
Dynamic characteristics of wrap-around microchannel condenser coil are essential to heat pump water heater (HPWH) during heating-up transient. In this paper, effectiveness of applying liquid-separation technology to the wrap-around microchannel condenser coil is discovered. A mathematical model adopting “quasi-steady-state” and “segment-tube-path” approaches is established for the water tank and microchannel condenser coil. Its predictions on both liquid-separation microchannel condenser coil (LMC) and conventional microchannel condenser coil (CMC) are in good agreements with experimental data. Results show that simply employing separators in the condenser coil (LMC-I) does not bring improvement. The average heat transfer coefficient of LMC-I is enhanced by 10.34% and 5.75% at the entrances of the second and third paths compared to that of CMC, respectively, whereas it is degraded at the outlets of the second and third paths as well as in the entire fourth path. However, LMC-I achieves a significant pressure drop reduction by 34.48%. Thereafter, LMC-II is screened from 963 candidates of path arrangements, and has better performances in terms of higher heat capacity and shorter heating time than both CMC and LMC-I. Its average proportion of 51.83% of two-phase area to the total area is also superior to both CMC and LMC-I.
Article
Accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.
Article
This paper deals with the condensation heat transfer characteristic of propane (R290) inside a 4-mm-inner-diameter (ID) horizontal smooth tube. Three-dimensional Computational Fluid Dynamics (CFD) simulations were performed based on the volume of fluid (VOF) multiphase flow model and shear stress transport (SST) k-ω turbulence model together with a dedicated user-defined function (UDF) compiled for the phase change model. The flow pattern and velocity field distribution were derived, and the condensation heat transfer coefficient (HTC) versus mass flux, saturation temperature, and heat transfer temperature difference were analyzed in detail. The results demonstrate that the area-weighted average condensation HTC of the wall takes on an average increase rate of 33.69% as the mass flux increases from 180 to 360 kg/(m2 s), and an average decrease rate of 19.83% with the increasing saturation temperature. Besides, the local condensation HTC swells more than twice as the temperature difference increases from 5 to 20 K. Compared with the saturation temperature, the mass flux and heat transfer temperature difference have a more remarkable effect on the condensation flow pattern and velocity field distribution. Under the specific conditions, the flow condensation of R290 inside the tube can be successively transformed from annular flow, annular wavy flow, half annular flow to plug flow, and the annular flow region can be enlarged with increasing mass flux. Comparing the simulated results with those of the experiment, it can be concluded that the numerical model adopted in this paper has good accuracy and the relative deviation is within ± 20%.
Article
R290 has obvious advantages in aspects of environmental protection and thermal properties, and researches on R290 room air conditioners (RACs) are attracting more and more attention. As for R290 RAC, the suction temperature is continuously low and a large number of refrigerants are dissolved in the compressor oil sump during defrosting process, resulting in a longer time length of the start-up process after defrosting. Two reverse-cycle defrosting methods, the discharge-throttling method (DTM) and suction-discharge bypass method (SDBM) are proposed in order to solve these problems. This paper compares the two defrosting methods on an R290 RAC by experiment and the results show that the defrosting time of DTM is relatively short, but the temperature at the inlet and outlet of the indoor heat exchanger is relatively low after defrosting. The SDBM can alleviate the situation of low suction temperature in the defrosting process, but the viscosity of the oil sump is large in the early stage of defrosting and the time length of the start-up process after defrosting is longer. Both methods have their own advantages and disadvantages, and the paper will provide an experimental basis for the reliability study of R290 RACs.
Article
Due to the great potential of propane in environmental protection and thermodynamic properties, the promotion of propane room air conditioner will make a great contribution to environmental protection. The defrosting behaviors of propane room air conditioner system and rotary compressor were studied by experiments in this paper. Experimental analysis redefines and distinguishes defrosting time and frost melting time, and their relationship with condition temperature is different. The experimental results show that the lower the ambient temperature was, the longer the defrosting time was, but the shorter the frost melting time on the outdoor heat exchanger was. The state of the oil sump and foam layer in propane rotary compressor using Mineral Oil (MO) was recorded and the variation reason for liquid level was analysed during defrosting. Combined with the change of viscosity and liquid level of the oil sump, the experimental results show that the compressor has abnormal oil discharged, and the lower the ambient temperature was, the larger the oil discharge was under three conditions during defrosting process. The total mass of the mixture in the oil sump under the three working conditions is 275.18 g, 289.10 g and 276.41 g, the lubricating oil is 202.97 g, 200.23 g and 189.71 g, and the refrigerant mass is 72.21 g, 88.87 g and 86.71 g respectively when the defrosting process ended. This study will provide an experimental basis of the reliability study and application of propane air conditioners.
Article
Heat pumps are often operated with nonoptimal amounts of refrigerant charge under various operating conditions; this results in excessive energy consumption by the air-conditioning systems in buildings. This paper proposes a novel variable liquid-line length system (VLLS) to improve the performance of heat pumps by optimizing the amount of refrigerant charge under various operating conditions. The feasibility of the VLLS is experimentally verified by proving that changes in the condensing and evaporating pressures afford the same effects as those of varying the amount of refrigerant charge. The performance improvement in the heat pump using the VLLS was evaluated by varying the heat sink and source temperatures under a fixed electronic expansion valve (EEV) opening and fixed superheat. The results indicate that the VLLS with a fixed EEV opening enhances the maximum capacity and coefficient of performance (COP) of the heat pump by appropriately controlling superheat and subcooling under various operating conditions. Furthermore, the heat pump adopting the VLLS with a fixed superheat exhibits substantial improvements in the heating and cooling COPs by varying the optimal amount of refrigerant charge.
Article
Due to the consensus on energy conservation and environmental protection in the international community, and considering the environmental protection and thermophysical properties, R290 has great advantages as an alternative working fluid compared with R22 in the field of air conditioner and heat pump. In the promotion process of the R290 air source heat pump (ASHP), the potential safety hazard caused by flammability can be controlled, but effective control methods are needed to ensure the reliability of the low-temperature heating process. In this paper, a new modified control strategy (MST) was proposed for R290 ASHP. The experimental results showed that the lubricating oil discharged from the compressor with MST was 10.55g less than the original control strategy (OST). In addition, when the temperature judgment condition for starting to adjust the opening of MST was 4°C, the performance was improved (using the MST) by about 1%. Whether from the point of view of reducing the discharge of lubricating oil from the compressor or the storage of refrigerant in the compressor and accumulator, the MST can effectively eliminate the oil blockage, thus improving the reliability of the heat pump system, while having beneficial impacts on the performance of the R290 heat pump.
Article
Full-text available
Hydrocarbons are today considered as promising alternatives to hydrofluorocarbons thanks to their low environmental impact and their easy implementation. However, some precautions have to be taken to thwart their flammability. European regulations impose to take stringent measures regarding components and to install heat pumps in unoccupied spaces. Nevertheless manufacturers keep working on components for hydrocarbons. In the frame of a research project on heat pumps for simultaneous heating and cooling, an R407C prototype working with a scroll compressor was built and tested. A near-industrial prototype is today being designed for propane with the help of recent modelling techniques. After having detailed the main issues regarding hydrocarbons as refrigerants, this article reviews scroll compressor modelling studies and presents the development of a thermodynamically realistic scroll compressor model. It was first developed for R407C and then adapted to thermodynamic properties of hydrocarbons and to other sizes of compressors.
Article
D'un strict point de vue thermodynamique, le recours aux fluides naturels (hydrocarbures et ammoniac) peut avantageusement être proposé pour pallier les interdictions portant sur les fluides halogénés. L'utilisation de ces fluides doit s'accompagner d'une réflexion sérieuse sur les risques technologiques associés à leur utilisation. Cet article recense le type de risque associé à ces fluides naturels (inflammabilité, explosivité et toxicité) et propose des méthodes de calcul des conséquences d'accidents (débits de fuites et distances d'effets). Ces méthodes, dans la majorité des cas applicables à des installations industrielles, sont extrapolées à des installations frigorifiques de petite taille.
Article
For environmental protection, flammable hydrocarbon refrigerants have been applied to domestic refrigerator and air conditioners. How to reduce refrigerant charge is the main problem for the safety use of hydrocarbons. A novel low charge microchannel condenser was proposed and investigated experimentally and numerically in domestic air conditioner system. Experimental results show that in comparison with normal microchannel condenser, cooling capacity of the novel condenser system increased by 1.6%, system refrigerant charge decreased by 28.3%. The optimum charge for R290 was reduced to 190 g, which meet the safety requirement of China National Standard GB 4706.32-2012. A numerical model of domestic air conditioning system (3.2 kW) with this new condenser was established. Parametric analysis of the new condenser and its impact on the system performance was studied. It was found that the reasonably reducing header inner diameter and flat tube hole diameter can cause more refrigerant charge reduction in condenser (−6.9% and −45.5% respectively) and almost no energy efficiency attenuation. Flow pass arrangement and its impact on refrigerant charge were also studied in this paper. If the novel condenser are fully optimized or other components of the air conditioning system (like compressor) are improved, the system charge may be reduced to 150 g, so as to meet IEC safety charge requirement.
Article
In this work, a new prototype of glazed flat plate solar collector is presented and its performance is experimentally characterized. The new collector uses a roll-bond absorber plate made of aluminum. The roll-bond is a production process aimed at manufacturing canalized panels by bonding two aluminum sheets with a rolling technique. Thus, in this prototype, the channels for liquid are integrated in the absorber plate. Measurements of thermal efficiency are reported for two prototypes, one with a black coating and the other with a semi-selective coating and those measurements are compared with those of standard glazed flat plate collectors at the same test conditions. The test runs have been performed in several conditions in order to reproduce different uses: hot water, space heating and solar cooling. The effect of the coating of the absorber is also evaluated and discussed using the experimental data collected. Efficiency test runs have been performed on a test rig both in steady-state and in quasi-dynamic conditions, according to the standard EN 12975-2 (2006). The results are presented in terms of efficiency curves. A three-dimensional model is used to predict the behavior in steady-state conditions of the solar collectors to obtain the efficiency curve. The model was implemented for standard glazed flat plate collectors but, in this work, its use is extended to roll-bond solar collectors and its validation is made by the comparison with the efficiency curve obtained from experimental tests.
Article
In this investigation, a direct expansion solar assisted heat pump (DX-SAHP) water heating system using an optimized-channel roll-bond collector/evaporator was designed, fabricated and tested. Optimized fractal T-shape and honeycomb shaped channel patterns were adopted to improve the thermal performance of the roll-bond panel, which acts as both the evaporator for the heat pump system and the collector for solar thermal utilization. The performance of the studied water heating system using the south-faced, wall-mounted roll-bond panel with the new composite channel patterns was investigated experimentally. Results show that, under the experimental conditions, the roll-bond panel with optimized channel pattern shows better thermal properties, and the performance the DX-SAHP system is significantly enhanced by using the roll-bond panel with optimized channel pattern. Compared to the conventional parallel channel pattern, fractal T-shaped channel pattern enhanced COP of the system by 14.6%, and heating capacity by 17.3%. And the honeycomb shaped channel pattern further enhanced COP and heating capacity of the system by 5.9% and 6.2%.
Article
R-290 (propane) has been chosen as one of the most potential next generation working fluids of RACs because of its favourable environmental and thermo-physical properties. However, its use is hindered by its flammability and resulting concerns on safety. In addition, the charge mass is limited strictly by the standards which would impact RAC’s heating performance. In this paper, refrigerant mass distributions within a R290 split type air conditioner were experimentally investigated at both static and dynamic state, in which the liquid nitrogen method (LNM) was used to determine the refrigerant mass inside the components of the circuit. The distribution of refrigerant that changes with temperatures and compressor speed were also measured and discussed. The results can assist with improving the design of the products (performance improvement, safety measures, etc.) and providing data for further theoretical study and simulation analyses.
Article
A prototype of glazed flat plate solar collector with roll-bond absorber is presented and its performance is experimentally characterized. Differently from common sheet-and-tube collectors, in the present prototype the channels for the liquid are integrated in the roll-bond absorber plate. Measurements of thermal efficiency are reported for two samples of the prototype, one with a black coating on the absorber and the other with a semi-selective coating. Efficiency test runs have been performed in both steady-state and quasi-dynamic conditions, according to the standard EN 12975-2 (EN 12975-2. Thermal solar systems and components solar collectors part 2: test methods. Brussels: CEN; 2006). The efficiency measurements are compared with those taken for standard glazed flat plate collectors with sheet-and-tube absorber under the same test conditions. The experimental results show that the roll-bond absorber can provide higher performance. Besides, the thermal efficiency can be further increased and this is shown by means of a numerical model. The model is experimentally validated for standard flat plate collectors with sheet-and-tube absorber and for roll-bond collectors.
Article
This short communication reports a study of the potential for refrigerant charge reduction in vapor compression refrigeration systems by means of a liquid-to-suction heat exchanger. The analysis was carried out on purely thermodynamic grounds for refrigerants of current interest, such as R134a, R22, R290, R600a and R717, assuming the cooling capacity as a constraint so that the evaporating pressure is free to vary. It was found that the minimum amount of refrigerant can be reduced depending on the thermophysical properties of the refrigerant, the working conditions, and the charge inventory.
Article
In several situations, a heat pump for simultaneous heating and cooling (HPS) can be installed advantageously in buildings where simultaneous needs occur. Unlike a reversible heat pump that works alternatively in heating or cooling, a HPS operates under three modes: a heating mode, a cooling mode and a simultaneous mode. In this article, different types of buildings are simulated using Trnsys software to identify their needs for heating, cooling and domestic hot water production (DHW). The introduction of a ratio of simultaneous needs in heating and cooling (RSN) can qualify buildings in relation to the appropriateness of a HPS. Three kinds of buildings are investigated (a low-energy building, an office building, and a retail space) under three different climatic conditions in France. As the design of a heat pump is highly dependent on the refrigerant properties, models of small-to-medium HPS using R407C, R290 and HFO1234yf are developed. Results of experimental tests on a 15 kW-heating-capacity HPS working with R407C were used to validate the numerical models of components and global model. Finally, a co-solving technique using two environments (EES and Trnsys) is used to compare the performance of the different refrigerants coupled to the building having the best RSN.