ArticlePDF Available

Abstract and Figures

Energy efficiency in buildings is today a prime objective for energy policy at national and international levels. Because the residential and commercial energy consumption has steadily increased reaching figures between 20% and 40%. The use of thermal insulation of the building envelope is one of the most currently requested solutions to reduce this energy consumption. Phase Change Materials (PCM) have received increased attention due to their ability to store large amounts of thermal energy within narrow temperature ranges. This property makes them ideal for storage of passive heat in the building envelopes. An experimental study was conducted to analyze the influence of PCM in the construction of exterior walls. Two test cells are constructed in the Faculty of Science Ain Chock, Casablanca. One is equipped with a 0.56 cm layer of PCM on its roof while the second is a reference cell without PCM. The results presented for the period from 8th to 10th July 2014 show that the integration of PCM layer reduces the amplitude of instantaneous heat flux through the horizontal wall. The indoor and the internal vertical wall temperatures, in the case of the cell with PCM, are relatively decreased compared to those of the reference one. For example, the maximum deviation between the indoor temperatures of the cubicles is not more than 1.5˚C while the one on the west faces reaches 3˚C by mid day. Also the inclusion of a layer of PCM shifts the time of peak load and discharge
Content may be subject to copyright.
Journal of Power and Energy Engineering, 2016, 4, 26-37
Published Online August 2016 in SciRes. http://www.scirp.org/journal/jpee
http://dx.doi.org/10.4236/jpee.2016.48003
How to cite this paper: Mourid, A., El Alami, M. and Najam, M. (2016) Passive Study of Energy Efficiency of a Building with
PCM on the Roof during Summer in Casablanca. Journal of Power and Energy Engineering, 4, 26-37.
http://dx.doi.org/10.4236/jpee.2016.48003
Passive Study of Energy Efficiency of a
Building with PCM on the Roof during
Summer in Casablanca
Amina Mourid, Mustapha El Alami*, Mostafa Najam
Laboratory of Physics of Materials, Microelectronics, Automation & Thermal (LPMMAT), Department of Physics,
Faculty of Sciences Ain Chock, Hassan II University of Casablanca, Casablanca, Morocco
Received 18 April 2016; accepted 30 July 2016; published 3 August 2016
Copyright © 2016 by authors and Scientific Research Publishing Inc.
This work is licensed under the Creative Commons Attribution International License (CC BY).
http://creativecommons.org/licenses/by/4.0/
Abstract
Energy efficiency in buildings is today a prime objective for energy policy at national and interna-
tional levels. Because the residential and commercial energy consumption has steadily increased
reaching figures between 20% and 40%. The use of thermal insulation of the building envelope is
one of the most currently requested solutions to reduce this energy consumption. Phase Change
Materials (PCM) have received increased attention due to their ability to store large amounts of
thermal energy within narrow temperature ranges. This property makes them ideal for storage of
passive heat in the building envelopes. An experimental study was conducted to analyze the in-
fluence of PCM in the construction of exterior walls. Two test cells are constructed in the Faculty of
Science Ain Chock, Casablanca. One is equipped with a 0.56 cm layer of PCM on its roof while the
second is a reference cell without PCM. The results presented for the period from 8th to 10th July
2014 show that the integration of PCM layer reduces the amplitude of instantaneous heat flux
through the horizontal wall. The indoor and the internal vertical wall temperatures, in the case of
the cell with PCM, are relatively decreased compared to those of the reference one. For example,
the maximum deviation between the indoor temperatures of the cubicles is not more than 1.5˚C
while the one on the west faces reaches 3˚C by mid day. Also the inclusion of a layer of PCM shifts
the time of peak load and discharge.
Keywords
Energy Efficiency, Experimental Study, PCM, Solar Radiation Insulation, Summer, Casablanca
*
Corresponding author.
A. Mourid et al.
27
1. Introduction
The energy consumption is expected to increase rapidly in the coming years due to the significant development
of the building sector as well as the significant increase in household equipment rate appliances. The Moroccan
policy framework is focused on reducing energy consumption in the building sector and so thermal insulation in
buildings is imposed as an important factor to achieve thermal comfort for the occupants and to reduce un-
wanted heat loss or gain. The aim is to reduce the energy consumptions. Note that housing and tertiary (hospitals,
hotels…) are responsible for, approximately, 25% of the total energy consumption in Morocco [1]. One such
method is to incorporate PCM to the lightweight buildings. Phase Change Materials are smart materials that are
based on a simple physical principle: they liquefy absorbing energy from a certain temperature characteristic for
each type of materials (generally determined by their chemical formulation), and restore the energy when the
temperature of their environment decreases.
When selecting a PCM, its melting and freezing temperatures should be close to the range of the average
room air temperature. Then many factors influence the choice of the PCM: weather, building structure and
thermos-physical proprieties [2].
The use of phase change materials has been studied since the 1940s [3] [4]. However, their usage in building
has been the subject of several studies. Kuznik et al. [5] examined the effect of integration of PCM wallboard in
the lateral walls and the ceiling of renovated tertiary building. Two identical rooms have been tested: The first as
reference and the second was equipped with an ENERGAIN PCM. This later was characterised by the authors
using Differential Scanning Calorimeter Method (DSC). It was reported that its melting and freezing tempera-
tures were 13.6˚C and 23.5˚C, respectively. The results showed that the PCM enhanced the thermal comfort of
occupants. They concluded, too, that the thermal comfort improvement could be efficient if the building was of
low thermal inertia and if the temperature variations were around the phase change temperature of used PCM.
An energetic and economic study related to the application of PCMs Boards in building enclosures was con-
ducted by Sun et al. [6]. In this study, the solar energy stored by PCM in the day is recovered at night either
naturally using outside air, or by using cooling systems that consume electrical energy (less expensive during the
night). They developed a heat transfer model to analyse electric energy consumption during the cooling season
for five different climate regions in China. Energy saving ration and simple payback period were used to assess
the simulation application. Their results showed that the energy saving ratio was 100% when a cold energy
source was used and then the use of PCMs did not offer economic benefit from reduced air conditioning. An
acceptable payback period was obtained the phase change temperatures were 3˚C higher than mean outdoor
temperature. Lee et al. [7] studied thermal performance of building walls integrating PCMs. Heat reduction and
heat transfer time delay were evaluated in this work. The PCM was incorporated as thin layers placed longitudi-
nally within the walls at different depths. Note that this study was realized experimentally using two test houses
and concerning the thermal performance of the south and west facing walls with and without PCMs. Five posi-
tions of PCM layer was examined (1 to 5 from inside to outside) at intervals of 1.27 cm. The results showed that
the optimal location of PCM layer (location for which heat transfer reduction was maximum) in the south wall
was 2.54 cm and that in the west wall was 1.27 cm from the wallboard. Peak heat flux reductions were 51% and
29.7%, at these locations, for the south wall and the west wall, respectively. The maximum heat flux time delays
were 6.3 h (PCM placed at the wallboard) for the south wall and 2.3 h in the west wall (PCM located at 1.27 cm
from the wallboard). Thermal performance of a PCMTS was evaluated, using a dynamic wall simulator, by Jin
et al. [8]. In this work authors used a mixture of gypsum and PCMs (10% by weight of PCMs). They developed
a PCM layer integrated into a prototype walls and they evaluated the thermal performance of this system in three
different locations within the cavity of a typical North American building walls. The experimental results
showed that, compared to a wall without PCMTS, the peak heat fluxes were reduced by as much as 11% when
the thermal shield was placed in the inward-most location next to the internal face of the gypsum wallboard
within the wall cavity. The PCM thermal shield produced only small effects on the peak heat fluxes when it was
placed half way between the enclosing surfaces of the internal cavity of the wall and almost no effect when it
was placed next to the internal face of the outermost layer of the wall.
Two identical cells with Vacuum Insulation Panels (VIP) light wallboards with and without PCM were stud-
ied by Ahmad et al. [9]. Temperature and heat flux were determined and compared to a numerical simulation
with TRNSYS software. The study showed that the PCM could reduce the indoor temperature amplitude. In
Lleida (Spain), Castell et al. [10] tested several cubicles that were made with conventional and alveolar brick.
Two different microencapsulated PCMs (SP-25 A8 (hydrate Salt with melting point 26˚C) and RT-27 (paraffin,
A. Mourid et al.
28
melting temperature 28˚C) provided by RUBITHERM) were added to the cubicles. Two different experiments
were performed: the first measuring the indoor temperature and the second measuring the consumption when
domestic heat pumps controlled the inner temperature for the cubicles. The temperatures in the cubicles with
PCM were reduced compared with the cubicle without PCM and the energy consumption of the cavities using
RT-27+PU was reduced about 15% compared to cells with PU, while the cavities with the SP-25+Alveolar had
achieved 17% of energy reduction, compared to cubicle with alveolar one.
In a large scale, Mandilaras et al. [11] studied a two-story typical family house in mid-west Greece, which
incorporated gypsum panels with PCM. Experimental measurements performed with an unoccupied house
showed that the indoor air temperatures, in all thermal zones of the building, do not significantly vary during a
24 h day-night cycle, leading to a decrease in the decrement factor and an increase in the time lag.
The objective of this study is to evaluate the thermal performance of residential walls equipped with a phase
change material on the roof during summer 2014. The experimental set-up consists of two identical cells built at
the Faculty of Science Ain Chock Casablanca.
2. Experimental Setup
The experimental set-up consists of two cells, kind of living rooms, located at the Faculty of Science Ain Chock
(FSAC), Hassan II University of Casablanca, Figure 1(a). The first sample (reference cavity) is made with
standard walls, and the other one is equipped with PCM on the roof. They are equipped with 75 Thermocouples
K-Type (2/10 mm). The assembly is connected to a data acquisition as shown in Figure 1(b).
2.1. Phase Change Material (PCM)
The phase change material (PCM) used is Energain product qualified by Dupont de Nemours (Luxembourg)
company. The product in the form of panel consisting of two aluminium sheets 130 μm thick is composed of a
solid compound copolymer (ethylene, 40%) and paraffin (60%).
The panels have dimension of 1 m × 1.2 m × 0.00526 m and melting temperature of PCM (paraffin) is 21.7˚C,
an enthalpy of 70 kJ/kg. The thermal conductivity is 0.18 Wm1K1 in the solid phase and decreases to about
0.14 Wm1K1 in liquid phase. The Energain panel 5 mm thickness is equivalent to 30 mm of concrete as a
function of temperature. The choice of this PCM is mainly dictated by its melting temperature, which is close to
human comfort and its availability in the market.
2.2 Test Cells
The cavities have dimensions of 3 m × 3 m × 3 m, Figure 1(a). The north wall is equipped with a laminated
wooden door (1 m × 2 m) and a single glazed window (1 m × 1 m). The vertical walls have a thickness of 30.62
cm and are composed of five layers (1 cm of mortar, 7 cm of alveolar yellow brick, 14 cm of air layer, 7 cm of
alveolar yellow brick and 1 cm of mortar). The outer face of the roof is covered with PCM panels. Thus, the
ceiling is composed of the following layers (from inside to outside): 2 cm of mortar, 12 cm of heavy concrete, 2
cm of mortar and 0.526 cm of PCM.
2.3. Instrumentation and Measurements
The cells are instrumented with thermocouples K-type (2/10 mm) in each wall. They are, carefully, welded,
Figure 1. Experimental setup. (a) View of the cell; (b) Figure of the experiment: PCM on the roof; (c) PCM Panel.
PCM
A. Mourid et al.
29
ensuring that the weld is of the same diameter that the two wires. Then, they are calibrated and connected to
multiplexers in the data acquisition device. The absolute thermal errors (ϴmeasured-ϴSet point) do not exceed 0.1˚C.
The thermocouples are distributed in order to access to the average temperatures of all the walls and the indoor
temperature of the samples.
Note that, achieving temperatures and heat flux measurements in a cell at the scale 1 in-situ is facing a serious
control problem of boundary conditions. They are conditioned by the weather conditions of the site, which vary
considerably with time.
We recall that experimental determination of the thermal resistance of walls always presents practical prob-
lems in the field for thermal analysis as well as for the determination of energy savings. In recent years, experi-
mental activity has been conducted solely in the laboratory using prototypes of walls built with reduced scale. In
particular, the test facility designed and built prototypes based on directives that met the objectives of a large set
of international standards [12]. Measurements of both surface temperatures and heat flux related to a wall in
steady state conditions were thus determined. Also, one must to consider that, notwithstanding the extreme ac-
curacy of the measurement in the laboratory, the thermal resistance of the wall determined in-situ might present
a significant deviation from the resistance determined from the prototype. This deviation is due not only to the
inevitable differences among supplies of the same material made in different time periods, but also to the inevi-
table differences in the conditions of wall-building [13].
In our procedure, we chose the period from 8th to 10th July in this study, because it shows some moderation in
Casablanca weather fluctuations, compared to other periods of summer.
2.4. Weather Data
The cavities are located in Casablanca FSAC (33˚32'N latitude, 7˚39'W longitude and altitude 57 m). The
weather data used in this study are those relating to 8th to10th July 2014, measured using our weather station in-
stalled on the roof of the FSAC. These data were measured with a time step of one hour and concerning: Out-
door temperature, humidity, global solar radiation, wind speed and wind direction. Note that for this period, ex-
ternal temperature fluctuations are not very important and do not exceed 6˚C as shown in Figure 2. Global heat
radiation is presented in Figure 3. It is practically identical for the three days of measurement. It maximum val-
ue is around 850 W/m2. Against, the wind speed has varied considerably between the nights of 8th to 9th July,
Figure 4. These fluctuations will act on the outer heat exchange coefficient and thus the thermal resistance of
the walls.
3. Equations
The equation used to calculate the thermal resistance for different walls is as follows:
Figure 2. Outdoor temperature, 8th to 10 July 2014.
A. Mourid et al.
30
Figure 3. Solar radiation (W/m2), 8th to 10 July 2014.
Figure 4. Wind Speed variation, 8th to 10 July 2014.
i
tii
e
R
λ
=
, ,1i n=
(1)
n: number of the wall layers.
However, in large spaces such as wall cavities, heat can still be lost across the air layer (inside the wall) by
convection and radiation.
Table 1 summarizes the calculation of the thermal resistance of the various walls taking into account their
composition.
The thermal conductivity of air is about 0.026 W/mK, the value 0.09 W/mK, considered in this work (Table
1, found in TRNSYS16 database) reflects the weak natural convection that may exist in the layer air.
The heat flux exchanged is calculated relating to the overall strength taking into account the internal natural
convection and the external free convection:
11
t
ie
R
hh
θ
φ
=
++
(2)
A. Mourid et al.
31
Table 1. Characteristics of the different layers of the walls.
Wall Material Thickness (e) (mm) Thermal Conductivity (λ) (W∙m1K1) Resistance (R) (m2K∙W1)
Vertical walls
Mortar 10 1.15 0.008
Brick 70 1.15 0.061
Air gap 140 0.09 1.555
Brick 70 1.15 0.061
Mortar
10
1.15
0.008
Ceiling
PCM 5.26 0.18 0.029
Mortar 20 1.15 0.017
Heavy concrete 120 1.75 0.068
Mortar 20 1.15 0.017
Floor
Mortar 100 1.15 0.087
Polysterene 50 0.02 2.500
Heavy concrete 100 1.75 0.057
Calc
300
2.25
0.133
The thermal convective heat transfer coefficient describing heat exchanged along the external and internal
faces of the building walls, can be calculated using approximated correlations from previous work [14] [15], re-
spectively:
2
0.0203* 1.766* 12.263
e
h VV=− ++
(Wm2K1) (3)
8.3
i
h=
(Wm2K1) (4)
4. Results and Discussion
In order to minimize the heat gain in the summer period, we placed the PCM on the roof of the test cell. To
highlight the contribution of PCM for insulation against the solar radiation and storage, we performed a system-
atic comparison of the internal and external temperatures of the walls and the room temperature with and with-
out PCM. The preliminary results presented in this paper are obtained for the period from 8th to 10th July 2014,
for which we consider that the boundary conditions are fairly stable and uniform in order to use the steady state
method in our evaluation process of thermal resistance.
Thermal Profiles
Figure 5 and Figure 6 illustrate the temperature variations of west and south walls of the two cavities, respectively.
These walls are exposed to solar radiation more than the other plates. In case of the west wall of the sample with
PCM (Figure 5), the temperature of the inside surface is lower than the inner temperature of the same wall of
that without PCM, during the day. The situation is reversed during the night. It turns that the integration of PCM
on the roof can reduce the temperature fluctuations of 2.53˚C during our test period. Figure 6 shows that the
external temperature fluctuated from 20.70˚C to 31.56˚C and the internal temperature is varying between a
minimum of 25.67˚C and a maximum of 29.01˚C for the cavity with PCM while in the case without PCM, it
varies from 25.7˚C to 30.04˚C, during these three days. The incorporate PCM in the ceiling allows a reduction
of the temperature for different walls of the cavity (different orientations).
Moreover, we can observe a remarkable difference between the surface temperatures of west wall and that of
the south wall, in both cases (with and without PCM), it is due to the significant insolation received by the south
faces.
The variation of the indoor temperature of the two cells (with and without PCM) is shown in Figure 7. It is
found that the indoor temperature of the cubicle with PCM is reduced by 1.5˚C compared to the one without
PCM. This can be explained by the good thermal inertia presented by the phase change material (PCM). This
difference between indoor temperatures is directly affecting the comfort sensation, according the well-estab-
lished comfort theories. In Table 2 we summarized the thermal time shifts for the cell walls.
The reduction of heat inputs through the ceiling (by introduction of the PCM) does not only affect the
A. Mourid et al.
32
Figure 5. Evolution of the external and internal temperatures of the west
face of the two cavities.
Figure 6. Evolution of the external and internal temperatures of the south
face of the two cavities.
temperature of the walls but also the indoor temperature of the cell. The latter is the result of heat exchange be-
tween the cavity and the outside through the walls (usually it is calculated by weighting temperatures of differ-
ent surfaces). The latter (walls) are at different temperatures, for given time (depending on their orientation).
The differences that present the wall temperatures for both cavities are not synchronized (when the difference
related to the southern walls is low, that of the East walls are important and so on). Knowing that the indoor
temperatures are closely related to those of the walls at a specific time, it is normal that the gap between them
will not be comparable to those of walls.
Time (h)
Temperature (°C)
012 24 36 48 60
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Without PCM
With PCM
Outside
Time (h)
Temperature (°C)
012 24 36 48 60 72
19
20
21
22
23
24
25
26
27
28
29
30
31
32
With PCM
Without PCM
Outside
A. Mourid et al.
33
Figure 7. Evolution of the indoor temperatures of the cavities.
Table 2. Time shifts between the temperatures of the two cells.
Cavity with PCM Cavity without PCM
θ
max (˚C) Time
θ
max (˚C) Time (s) Time shift
West Wall 27.357 21 h 23 mn 30.153 19 h 43 mn 1 h 40 min T 2 h 20 min
South Wall 29.056 19 h 43 mn 30.107 19 h 33 mn 10 min T 30 min
Ceiling 32.597 18 h 23 mn 31.921 17 h 13 mn 40 min T 3 h 30 min
Indoor
Temperature
29.7863 18 h 23 mn 30.587 19 h 03 mn 20 min T 1 h
We present the heat transfer between the two cavities and the outside in terms of heat flux densities through
the various walls. In this paper, only those relating to the ceilings, the west and the south walls will be exposed
and discussed.
Figure 8 shows the heat flux evolution of the two ceilings with and without PCM. First, we note that, there is
a significant gap between the two heat flux densities during this period. The insulation effect of PCM is clearly
visible during the day as can be seen on the maximum curve (φmax, with_PCM = 58.35 W/m2, φmax, without_PCM = 63.80
W/m2). The Aluminium layer reflects a significant portion of solar radiation in our setup. It will reduce, signifi-
cantly, the solar flux absorbed by the PCM, knowing its reflectivity against the radiation which is about 0.9. In
this work, we have not considered this aspect because our objective was focused on the study of the thermal ef-
ficiency of the local, but we evaluated the effect of the entire PCM panel. In further configurations, we will
cover the panels by a very few reflector materials to highlight the only effect of PCM. The effect of the thermal
inertia is very clear; a delay of three hours is observed (Table 2). This leads to a significant reduction in energy
consumption during the discharge period (night). The cells do not cool in the same way. In fact, the heat flux
density on the cell with PCM remains greater than or equal to zero while that of the reference cell drops to 10
W/m2. This is due to the refund of the amount of heat previously stored (in the form of latent heat) in the PCM.
Based on the analysis of representative figures of the heat flux exchanged through the vertical walls, we dis-
tinguish the emergence of two phenomena during the day. As an example, we present Figure 9 and Figure 10
showing heat fluxes related to the West and South walls of the two cavities. Generally, it is noted that the heat
flux values range from maximum (positive) and minimum (negative) for a period of 24 hours. From 6 h 00 to 13
h 00 both cells yield the same heat flux density while for the rest of the day, the exchanged heat flux are different
Time (h)
Temperature (°C)
0 12 24 36 48 60
23
24
25
26
27
28
29
30
31
32
With PCM
Without PCM
A. Mourid et al.
34
Figure 8. Evolution of the heat flux densities of ceilings with and without
PCM.
Figure 9. Evolution of the heat flux densities of west wall for the two cavi-
ties.
from one cell to the other one. Through the west wall, the maximum value in the cavity without PCM is 2.98
W/m2, while in the cell with PCM; it reaches 2.62 W/m2. This remark also applies to the south wall. We can
note also that the time shift is approximately 6 hours for the two walls. So it is an important thermal inertia in-
troduced by the PCM.
During the first period, the similarity of the heat flux is due to internal wall temperatures, which are substan-
tially equal. The difference observed in the second period is due to the time shift between the internal and exter-
nal temperatures of the two cells (see Figure 2 and Figure 3).
Time ( h)
Flux (W/m2)
0 12 24 36 48 60
-10
0
10
20
30
40
50
60
With PCM
Without PCM
Without PCM
With PCM
Time (h)
0 10 20 30 40 50 60 70
ϕ(w/m
2
)
3
−1
2
1
0
−2
−3
−4
A. Mourid et al.
35
Figure 10. Evolution of the heat flux densities of south wall for the two
cavities.
The heat flux through the ceiling is almost 10 times greater than those for vertical faces. The difference of the
heat fluxes of the two ceilings arrives to 11.2 W/m2. This suggests the importance of the ceiling insulation
against solar radiation in Morocco.
5. Conclusions
We conducted an experimental study of the thermal performance of two cavities like living quarters built, in-situ
within the Faculty of Science Ain Chock, Casablanca. One of them is equipped with a PCM on the roof, during
summer of 2014.
The results show that the integration of PCM on the roof of the building reduces the indoor temperatures of
the cells by 1.5˚C and those of the internal walls of 2.53˚C. We also note that the amplitude of thermal oscilla-
tions of south and west walls decreases.
The study of heat transfer, through the vertical walls and ceilings of the two cells, led to conclude that the
PCM was a good insulation and storage agent on the one hand, and greatly increased the thermal inertia of the
cavity with PCM, on the other hand (due to the return of the heat stored during the day).
According to the same study, it is imperatively important to insulate the ceilings of residential premises
against solar radiation: the gap between the two streams of the ceiling with and without PCM reaches 11.2 W/m2.
Note that solar radiation constitutes the major part of the overall gain in Morocco. Therefore, there will be a sig-
nificant reduction of energy used to cool the local. Furthermore, there is a significant time shift presented by the
temperatures and the heat flux densities due to PCM incorporated in the ceiling.
Acknowledgements
Authors acknowledge the financial support provided by IRESEN Institut de Recherche en Energie Solaire et
Energies Nouvelles” Morocco.
References
[1] (2012) Règlement Thermique de Construction au Maroc, Version simplifiée. Agence de Développement des Energies
Renouvelables et de l’Efficacité Energétique, ADEREE.
[2] Darkwa, K., O’Callaghan, P.W. and Tetlow, D. (2006) Phase-Change Drywalls in a Passive-Solar Building. Apply En-
ergy, 83, 425-435. http://dx.doi.org/10.1016/j.apenergy.2005.05.001
Time (h)
Flux (W/m2)
012 24 36 48 60
-3
-2
-1
0
1
2
3
Without PCM
With PCM
A. Mourid et al.
36
[3] Telkes, M. (1949) Review of Solar House Heating. Heating and Ventilating, 46, 68-74.
[4] Telkes, M. and Raymond, E. (1949) Storing Solar Heat in Chemicals. Heating and Ventilating, 46, 79-86.
[5] Kuznik, F., Virgone, J. and Johannes, K. (2011) In-Situ Study of Thermal Comfort Enhancement in a Renovated
Building Equipped with Phase Change Material Wallboard. Renewable Energy, 36, 1458-1462.
http://dx.doi.org/10.1016/j.renene.2010.11.008
[6] Sun, X.Q., Zhang, Z., Medina, M.A. and Lee, K.O. (2014) Energy and Economic Analysis of a Building Enclosure
Outfitted with a Phase Change Material Board (PCMB). Energy Conversion and Management, 83, 73-78.
http://dx.doi.org/10.1016/j.enconman.2014.03.035
[7] Lee, K.O., Medina, M.A., Raith, E. and Sun, X.Q. (2015) Assessing the Integration of a Thin Phase Change Material
(PCM) Layer in a Residential Building Wall for Heat Transfer Reduction and Management. Applied Energy, 137,
699-706. http://dx.doi.org/10.1016/j.apenergy.2014.09.003
[8] Jin, X., Medina, M.A. and Zhang, X.S. (2014) On the Placement of a Phase Change Material Thermal Shield within the
Cavity of Building Walls for Heat Flux Reduction. Energy, 73, 780-786.
http://dx.doi.org/10.1016/j.energy.2014.06.079
[9] Ahmad, M., Bontemps, A., Sallée, H. and Quenard, D. (2006) Thermal Testing and Numerical Simulation of a Proto-
type Cell Using Light Wallboards Coupling Vacuum Isolation Panels and Phase Change Material. Energy and Build-
ings, 38, 673-681. http://dx.doi.org/10.1016/j.enbuild.2005.11.002
[10] Castell, A., Martorell, I., Medrano, M., Pérez, G. and Cabeza, L.F. (2010) Experimental Study of Using PCM in Brick
Constructive Solutions for Passive Cooling. Energy and Buildings, 42, 534-540.
http://dx.doi.org/10.1016/j.enbuild.2009.10.022
[11] Mandilaras, I., Stamatiadou, M., Katsourinis, D., Zannis, G. and Founti, M. (2013) Experimental Thermal Characteri-
zation of a Mediterranean Residential Building with PCM Gypsum Board Walls. Building and Environment, 61,
93-103. http://dx.doi.org/10.1016/j.buildenv.2012.12.007
[12] ISO Standard 8301-1991. Thermal InsulationDetermination of Steady-State Thermal Resistance and Related Proper-
tiesHeat Flow Meter Apparatus.
[13] Laurenti, L., Marcotullio, F. and de Monte, F. (2004) Determination of the Thermal Resistance of Walls through a Dy-
namic Analysis of In-Situ Data. International Journal of Thermal Sciences, 43, 297-306.
http://dx.doi.org/10.1016/j.ijthermalsci.2003.08.007
[14] Zhang, L., Zhang, N., Zhao, F.Y. and Chen, Y.M. (2004) A Genetic-Algorithm-Based Experimental Technique for
Determining Heat Transfer Coefficient of Exterior Wall Surface. Applied Thermal Engineering, 24, 339-349.
http://dx.doi.org/10.1016/j.applthermaleng.2003.07.005
[15] Kaynakli, O. (2008) A Study on Residential Heating Energy Requirement and Optimum Insulation Thickness. Renew-
able Energy, 33, 1164-1172. http://dx.doi.org/10.1016/j.renene.2007.07.001
A. Mourid et al.
37
Appendix
Nomenclature
e: Thickness, mm.
he: Outdoor thermal convective heat transfer coefficient (W/m2K).
hi: Inside thermal convective heat transfer coefficient (W/m2K).
PCM: Phase Change Material.
r: Thermal resistance of a wall layer (m2/W∙K).
Rt: Global thermal resistance of wall (m2/W∙K).
Δθ: Temperature gap (ϴwi-ϴwe) (˚C).
Δts: Thermal Time shift.
φ
: Heat flux, W/m2.
λ: Thermal conductivity (W/m∙K).
ϴwi: Internal temperature of the wall (˚C).
ϴwe: External temperature of the wall (˚C).
Subscripts
i: internal.
e: external.
max: maximum.
min: minimum.
we: external face of wall.
wi: internal face of wall.
Submit or recommend next manuscript to SCIRP and we will provide best service for you:
Accepting pre-submission inquiries through Email, Facebook, LinkedIn, Twitter, etc.
A wide selection of journals (inclusive of 9 subjects, more than 200 journals)
Providing 24-hour high-quality service
User-friendly online submission system
Fair and swift peer-review system
Efficient typesetting and proofreading procedure
Display of the result of downloads and visits, as well as the number of cited articles
Maximum dissemination of your research work
Submit your manuscript at: http://papersubmission.scirp.org/
... The application of PCMs for cooling purposes in buildings was devised with the help of various reliable researches. The PCM may be applied for cooling in buildings in many ways including PCMs installation in walls [27][28][29][30][31][32][33][34], PCMs installation in roofs [31,35,36], PCMs installation in flooring [37], PCMs combination with bricks [33,38], and PCMs enabling ventilation [39,40]. It was found that 60% of the researches involved the PCMs in the walls using the encapsulation technology. ...
Article
Full-text available
Thermal energy storage systems have been investigated for the last decades, even though the information is quantitatively enormous with a few application works. In this study, a review has been carried out for the applications of phase change materials in the cooling of buildings, where these materials have tendency to gain extra heat (latent heat) during solid–liquid phase change. The study presents significant information regarding the use of phase change materials for cooling with many considerations like: climate conditions, types of phase change materials and their thermo-physical properties. Theresultant studies show that the integration of phase change material in the building have a good potential for reducing energy demand for cooling, further investigations are needed to really assess their benefits.
... The impact reduction by 10.5% and 9% was found in esters, compared with paraffin. The performance of PCM during the daytime in two residential buildings was analyzed (Mourid et al., 2016). The wall temperature increased by 6°C during the night, with increase in the thermal mass of the room. ...
Article
Full-text available
The present trend in building research is to improve sustainability in building construction and operation. The development of new renewable technologies is essential to improve the sustainability and to reduce emissions. The incorporation of phase change materials in buildings is an effective way to reduce the room temperature fluctuations and cooling loads/heating loads. Although several works have been carried out in this field, a novel phase change material clay hollow-brick composite has been used in this work. This article discusses the research on investigating the thermal performance of phase change material integration in building walls. Two identical test rooms (3 m × 3 m × 3.65 m) were constructed to study the effect of phase change material integration in buildings. The experimental buildings were constructed for the warm and humid weather conditions of Chennai city, India. Phase change material integration in the building wall is beneficial for reduction of room temperature and provides passive cooling of the building. The temperature drop in a phase change material room compared with a non-phase change material room varies from 6°C to 2°C, during various months of the year. DESIGNBUILDER simulation was carried out for phase change material and non-phase change material buildings during the months of January, March, May, and July. The simulated room temperature variation follows the same pattern in these months.
... Two test houses with a classic residential construction showed that the introduction of 1.27 cm of PCM wall panel in the west wall reduced maximum heat flux by 29.7 %, while the optimal location of 2.54 cm of PCM wall panel in the southern wall reduced maximum heat flux by 51.3 %, Lee et al. [13]. Mourid et al. [14,15,16]carried out an experimental thermal study using two identical real scale cells: One is equipped with PCM layer installed on the roof and / or in vertical walls. Authors notice a reduction of transmitted flux density from the ceiling to the cavity of 56.8% in the case of a single thickness of PCM layer, and of 88% with double layer of PCM, Compared with a reference cavity. ...
Article
Full-text available
The present work consists of a parametric study of a double wall separated by an air layer within PCM panels, exposed to solar radiation. This experimental study was conducted using two real-scale test cavities, located in the Faculty of Science Ain Chock-Casablanca, for active and passive cases. For this purpose, many thermocouples are used for the thermal control of indoor applications, as well as for measuring the temperature field of the air layer within PCM. The evolution of the measured temperatures will make it possible to calculate the heat fluxes densities exchanged through the walls to explore heat transfer inside the air layer with PCM. The results show that the temperature fluctuations are reduced by 1.8 °C for the internal face of the studied wall and by 1 °C for the indoor temperature of the room with PCM compared to the reference room.
... The advantage of PCM is that it is possible to store large amounts of heat or cold in small temperature ranges [4]. Several review papers have been published on the concept of using PCM in the building envelope: walls [5] [6] [7] [8] [9], ceilings [10] [11] [12], floors [13] [14] and windows. ...
Article
Full-text available
The purpose of this paper is to study the energy efficiency of a local living space exposed to solar radiation in the subtropical climate of Casablanca. The study was mainly focused on the contribution of a phase change material (PCM), inserted into a 7-cm thick air layer of a double brick wall, in two different locations. We note that the experimental study was conducted using two real-scale test cavities, located in the Faculty of Science Ain Chock-Casablanca. Two PCM mounting methods were used for the south and west walls, in order to test its energy efficiency as a storage and retrieval means of the solar flux coming from the outside. In the case of the southern wall, the PCM is put directly on the internal side of the outside part of the double wall (Case 1). For the west wall, the PCM is placed 1.2 cm away from the internal side of the outer part of the double wall (Case 2). The first result shows that the PCM placed to the wall allows storing the solar heat during the day and releasing it to the outside of the building at night. While in the second case, the PCM keeps the heat stored day and night.
... The results showed that this type of PCM room can decrease the indoor air temperature fluctuations by a maximum of 4°C. Mourid et al. (Mourid and El Alami, 2016) tested the effect of PCM into the roof during summer period, to control the indoor air temperature for a better thermal comfort. Their result showed that the Energain ® PCM wallboard reduced the indoor temperature with 1.5°C and delay the time of peak load and discharge. ...
Article
The study aims at analyzing the performance of phase change material (PCM) in two residential rooms within heating periods. This paper presents the results of experiments performed in the Faculty of Science Aïn Chock, Casablanca. The in-situ cells are identical with dimension of 3 m × 3 m × 3 m. The walls are made with double layer of alveolar brick (72 mm) separated by an air layer (126 mm). The internal faces of one of these cavities are embedded with a PCM layer (5.3 mm). The tested PCM is Energain® wallboard manufactured by DuPont™. The cavities are heated by oil radiators which delivered the same energy power. Measures focus on ambient temperatures, wall temperatures and instantaneous heat flux densities through the walls. Also, the effect of phase change material on energy consumption was investigated. The results, related to two periods (January 25th to 27th, 2015 and April 1st to 3rd, 2015), show that the inclusion of the PCM to a standard wall leads to a temperature increase about 6 °C during the night and increases strongly the apparent thermal mass of the room, which allows a reduction in heat fluxes. Finally, the heating energy savings resulting from PCM application can reach up to 20%.
... New technology has been developed like the supper insulating [5,6], radiant barriers [7,8], ventilated air cavity [9,10], green roof [11] and the cool materials [12,13]. Another approach based on the dynamic thermal properties has developed by the implantation of phase change materials [14,15,16]. ...
Article
Full-text available
In this paper, we present a comparative thermal study of the usual insulation materials used in the building as well as the innovate one like phase change materials (PCMs). Both experimental study and numerical approach were applied in this work for summer season. In the experimental study the PCM was installed on the outer surface on the ceiling of one of two full-scale rooms located at FSAC, Casablanca. A simulation model was performed with TRNSYS'17 software. We have established as a criterion of comparison the internal temperatures. An economic study also has been carried out. Based on this latter, that the PCM is most efficient.
Conference Paper
Currently, energy storage is becoming a real challenge in the face of this industrial and economic technological transition. The orientation toward the strategy of use of phase change materials represents a sustainable and efficient alternative to reduce energy consumption in terms of heating during the period of intermittence and increase the thermal comfort of the occupants. This work is devoted to carrying out a set of experimental tests to study the storage capacity of two types of phase change materials in order to test the feasibility of integrating them into building elements. The results obtained show that the increase in heating power at 80 W/m2 causes a significant phase shift of about 8.59 ℃ between the inside and outside surfaces of the plaster wall and the paraffin wax (2). In addition, this type of phase change material can store a significant amount of heat during the charging phase, which leads to an increase in wall temperature of approximately 4 ℃ during the intermittent period compared to the reference case. Finally, the results of the phase change material thermal conductivity measurements obtained by the box method are in accordance with the values given by the manufacturer.
Article
Phase change material (PCM) applied to roofs can weak external heat entering the room to reduce air-conditioning energy consumption. In this study, three forms of macro-encapsulated PCM roofs with different PCMs (RT27, RT31, RT35HC, PT37) are proposed. The effects of PCM thickness, the encapsulation forms, and different PCMs on the thermal performance of the roof are discussed in Moroccan semi-arid and Mediterranean climates. The results show that as the PCM thickness increases, the peak temperature attenuation of the roof inner surface decreases. In two climates, the pure PCM layer among the three encapsulation forms (i.e. pure PCM layer, PCM in aluminum tubes, PCM in triangular aluminum) is the easiest to appear the phenomenon of insufficient heat storage and release, while the reduction of the peak inner surface temperature and time lag is the most satisfying. For the PCM in the aluminum tube, phase change time is the shortest and the latent heat utilization ratio is the highest, while thermal regulation performance is the least satisfying. The PCM in triangular aluminum can improve the latent heat utilization ratio significantly, and its thermal regulation performance is in the middle. In semi-arid climate, the time lag increases with phase change temperature increasing. The time lag could reach up to 6 h with 37 °C phase transition temperature. In Mediterranean climate, the longest time lag with RT31 is 5 h, while the lowest peak inner surface temperature appears with RT27. The obtained conclusions could provide guidance for the application of PCM roofs in these two climates.
Chapter
Algeria’s energy needs are actually satisfied mainly through the use of hydrocarbons. Demand for energy is growing exponentially because the population is growing massively and the building sector is in full expansion in order to address and solve the problems of housing, health and education. In 2011, Algeria initiated a dynamic green energy program by launching an ambitious development project aims at developing a renewable energy power source of 22000 MW and to save more than 60 Million TOE in energy efficiency by the year 2030. Our research topic is linked to the energy efficiency program initiated in Algeria. The objective of this article in to present a study carried out on the thermal performance of Phase Change Materials (PCMs) and their integration in buildings in order to achieve thermal comfort and to reduce the energy consumption. Then, an investigation on the capacity of using (PCMs) in Algeria is presented for a sustainable development and rational energy consumption.
Article
Full-text available
The thermal performance of building walls integrated with phase change materials (PCM) was evaluated in terms of heat flux reduction and heat transfer time delay. To fully melt and solidify over daily cycles, PCMs must be incorporated as thin layers placed longitudinally within the walls. The thin PCM layer was integrated into the wall via a thermal shield, whereby the PCM was contained in thin sealed polymer pouches, arranged in sheets laminated with aluminum foil on both sides. This system is herein referred to as “PCM thermal shield (PCMTS)”. The optimal location of the PCMTS within the wall cavities is critical for heat transfer reduction and management. The thermal performance of south and west facing walls with and without PCMTS was evaluated experimentally using two identical test houses. The PCMTS was installed at various depths, one at a time, within the wall cavities. Each location depth was numbered from 1 to 5 starting at next to the wallboard surface facing the wall cavity (location 1) and proceeding to the exterior side of cavity at intervals of 1.27 cm. The results showed that the optimal location for a PCMTS in the south wall was location 3 (2.54 cm from the wallboard), while the optimal location for a PCMTS in the west wall was location 2 (1.27 cm from the wallboard). At these locations, the peak heat flux reductions were 51.3% and 29.7% for the south wall and the west wall, respectively. The maximum peak heat flux time delays were 6.3 h for location 1 in the south wall and 2.3 h for location 2 in the west wall. The maximum daily heat transfer reductions were 27.1% for location 3 in the south wall and 3.6% for location 5 in the west wall.
Article
Full-text available
This paper presents energy and economic analyses related to the application of phase change materials boards (PCMBs) in building enclosures during the cooling season. A heat transfer model was developed, which was implemented via a computer program. Simulations were carried out using weather data files from five cities located in five different climate regions in China. Energy savings from using a natural cold source (e.g., outdoor air) and electricity savings from a reduction in electricity by air conditioning systems were evaluated. The energy savings ratio (ESR) and simple payback period (SPP) were used to assess the application of PCMBs in building enclosures. The selection of optimum phase transition temperatures for the PCMs for the various climates was made using indoor and outdoor air temperatures, as well as SPP. For space cooling purposes, it was suggested that phase transition temperatures should be at least 3 °C higher than the mean outdoor air temperature. Simple payback period suggested the possibility of the cost effective use of PCMBs in occupied buildings for moderate temperature climates.
Article
Full-text available
Light envelopes are more and more frequently used in modern buildings but they do not present sufficient thermal inertia. A solution to increase this inertia is to incorporate a phase change material (PCM) in this envelope. This paper presents the performance of a test-cell with a new structure of light wallboards containing PCMs submitted to climatic variation and a comparison is made with a test-cell without PCMs. To improve the wallboard efficiency a vacuum insulation panel (VIP) was associated to the PCM panel. This new structure allows the apparent heat capacity of the building to be increased, the solar energy transmitted by windows to be stored without raising the indoor cell temperature, and the thickness of the wallboard to be decreased compared with that of traditional wallboards. An experimental study was carried out by measuring temperature and heat fluxes on and through the wallboards. The indoor temperature, which has a special importance for occupants, was also measured.A numerical simulation with the TRNSYS software was carried out in adding a new module representing the new wallboard. It showed a good agreement with experimental results. This new tool will allow users to simulate the thermal behaviour of buildings having walls with PCMs.
Article
PCMs (Phase change materials) are used to enhance the thermal storage capacity of building walls, decrease indoor air temperature fluctuations, and shift peak heat transfer rates to off-peak times. PCM location within building walls is recognized to be critical for the optimum performance of the system. One possible integration of the PCM into a wall could be via a PCM-layer or “shield,” herein referred to as “PCMTS” (PCM Thermal Shield). A prototype PCMTS was developed and its thermal performance was evaluated in three different locations within the cavity of a typical North American residential wall system using a dynamic wall simulator in this paper. The experimental results showed that, compared to a wall without a PCMTS, the peak heat fluxes were reduced by as much as 11% when the thermal shield was placed in the inward-most location next to the internal face of the gypsum wallboard within the wall cavity. The PCM thermal shield produced only small effects on the peak heat fluxes when it was placed half way between the enclosing surfaces of the internal cavity of the wall and almost no effect when it was placed next to the internal face of the outermost layer of the wall.
Article
In this paper a method for calculating the thermal resistance of a wall through the dynamic analysis of both heat flux and surface temperature samples is presented. Such a method models the transient thermal response of the wall through a linear relation with constant parameters that links the instantaneous heat flux at the inner surface of the wall to the temperature difference between the surfaces of the same wall at the same instant. Additionally, the linear relation mentioned above also links a certain number p of terms formed, each of them, by differences of the same variables related to the considered instant and to p previous instants. The number of the parameters of the model is derived through the principles of hypothesis testing. At this stage, the proposed method is applied to simulated data as indicated by the proposal of European standard 12494, 1996. The results shown here have been concerning with different typologies of wall, namely light, medium and heavy, as well as with 24 data sets obtained by picking data in the one-year time series. Although limited to winter and summer measurement periods, a comparison between the proposed method and classic average one is also performed.
Article
Heat loss from buildings has a considerable share in waste of energy especially in Turkey since no or little insulation is used in existing and new buildings. Therefore, energy savings can be obtained by determining of heat loss characteristics with using proper thickness of insulation. For this purpose, in this study, calculations of optimum insulation thickness are carried out on a prototype building in Bursa as a sample city. Considering long term and current outdoor air temperature records (from 1992 to 2005), degree-hour (DH) values are calculated, and the variation of annual energy requirement of the building is investigated for various architectural design properties (such as air infiltration rate, glazing type, and area). Then, the effects of the insulation thickness on the energy requirement and total cost are presented. Based on life cycle cost (LCC) analysis, the optimum insulation thicknesses are determined for different fuel types. As a conclusion, the length of the heating period is average 221 days, and the mean heating DH value is found as 45 113.2 besides changing between 38 000 and 55 000. The optimum insulation thicknesses for Bursa vary between 5.3 and 12.4 cm depending on fuel types. In addition to this, the variation in Turkey is more dramatically.
Article
Integration of phase-change materials (PCMs) into building fabrics is considered to be one of the potential and effective ways of minimising energy-consumption and CO2-emissions in the building sector. In order to assess the thermal effectiveness of this concept, composite PCM drywall samples (i.e., randomly mixed and laminated PCM drywalls) have been evaluated in a model passive-solar building. For a broader assessment, the effects of three phase-change zones (narrow, intermediate and wide) of the PCM sample were considered. The results showed that the laminated PCM sample with a narrow phase-change zone was capable of increasing the minimum room temperature by about 17% more than the randomly mixed type. Even though there was some display of a non-isothermal phase-change process, the laminated system proved to be thermally more effective in terms of evolution and utilisation of latent heat. A further heat-transfer enhancement process is, however, required for the development of the laminated system.