Computing human optical point spread functions

Authors:

Abstract

There is renewed interest in the role of optics in human vision. At the same time there have been advances that allow for routine standardized measurement of the wavefront aberrations of the human eye. Computational methods have been developed to convert these measurements to a description of the human visual optical point spread function (PSF), and to thereby calculate the retinal image. However, tools to implement these calculations for vision science are not widely available or widely understood. In this report we describe software to compute the human optical PSF, and we discuss constraints and limitations. © 2015 ARVO.
The full text of this paper is available for free
online at the journal.
... Watson [38] The author used Zernike aberration coefficients and the Fourier transformation to efficiently compute the PSFs of the human eye for varying pupil sizes and object distances Vision simulation was limited to a single object plane Tang and Xiao [39] This work simulated low-order eye aberrations in real-time using an elliptical Gaussian kernel and per-pixel blur field to support peripheral vision and variable eye parameters ...
... The simulation was limited to low-order aberrations and peripheral vision was not considered theory. To this end, Watson [38] used the Fraunhofer diffraction formula [47] as a more computationally efficient approach than ray tracing because it facilitates the computation of the PSF via the fast Fourier transform of the complex-valued generalized pupil function. More recently, Csoba and Kunkli [44] proposed the use of the extended Nijboer-Zernike (ENZ) diffraction theory [48] as an alternative means of computing human PSFs for vision simulation purposes. ...
... The situation is somewhat more complicated with diffraction theory, in which the wavelength-dependent aberration coefficients need to be obtained to compute the corresponding PSFs. Watson [38] and Cholewiak et al. [15,41] demonstrated that this problem can be solved using empirical formulas to derive the amount of defocus introduced by chromatic aberration. ...
Article
Full-text available
Vision-simulated imagery-the process of generating images that mimic the human visual system-is a valuable tool with a wide spectrum of possible applications, including visual acuity measurements, personalized planning of corrective lenses and surgeries, vision-correcting displays, vision-related hardware development, and extended reality discomfort reduction. A critical property of human vision is that it is imperfect because of the highly influential wavefront aberrations that vary from person to person. This study provides an overview of the existing computational image generation techniques that properly simulate human vision in the presence of wavefront aberrations. These algorithms typically apply ray tracing with a detailed description of the simulated eye or utilize the point-spread function of the eye to perform convolution on the input image. Based on the description of the vision simulation techniques, several of their characteristic features have been evaluated and some potential application areas and research directions have been outlined.
... Let ( , ) be the OA. The complex-valued generalized pupil function is then given [17]: ...
Article
Full-text available
The ocular aberrations (wavefront) can be used to describe the vision defects, and wavefront sensing devices (aberrometers) are used to measure the ocular aberrations (OAs). The Zernike polynomials (ZPs) have been successfully used in wavefront reconstruction algorithms of aberrometers for years. As the aberrometer measurements consist with noise, the measurements observed using aberrometers are not always accurate. It is therefore necessary to take multiple measurements from the patient in each sitting. However, taking multiple measurements also causes to induce the variations on measurements, and this variability of measurements is significant, and leads errors in clinical practice. Therefore, the variability should be taken into account during wavefront reconstruction. Consequently, unlike prior work, the accuracy of Zernike representation for the ocular aberrations with noise (due to the system noise and the variability of measurements) is studied. In the study, the noisy data is fitted using ZPs. Data sets are created using extracted data from arbitrary OAs, that is, synthetic data sets are used. Normally distributed very small random numbers are added into the data sets in order to create measurement noise. The magnitude of added noisy has been changed to range the signal-to-noise ratio (SNR) from 55 dB to 20 dB. The corresponding Zernike coefficients for each noised wavefront are computed, and visual acuity is used to examine the deviation of the reconstructed wavefront from the data set. The study concludes that the Zernike polynomials are not good enough to represent the wavefront with noisy level less than certain value of SNR which is greater than the reference SNR values of aberrometers, and note that the aberrometer SNR is always between 20-30 dB.
... The visual point spread function was discussed in the literature [40][41][42]. The important conclusion drawn based on the studies in the literature is the classification of the PSF responses to the foveal (<1˚) and stray-light (>1˚) fields. ...
Article
Full-text available
Nowadays many patients are choosing EDOF or multifocal lenses for replacement of natural lens in cataract surgery. This can result in issues such as presence of dysphotopsias, namely halo and glare. In this work, we propose a new perimetry method to describe dysphotopsias in far-field region in a presence of bright, point-like light source. We constructed a custom device and designed measurement procedure for quantitative measurement of dysphotopias in the center of visual field and used it to examine patients with mild cataracts or implanted IOLs. Our approach may help in establishing an objective method to study and compare dysphotopsias.
... From the wave aberration coefficients, different optical quality descriptors can be directly derived after mathematical operations [71,[75][76][77][78][79][80]. The two classic descriptors are the Modulation Transfer Function (MTF) and the Point Spread Function (PSF). ...
Chapter
Full-text available
Intraocular lens (IOL) power calculation is normally performed using theoretical Gaussian formulas. Paraxial calculation renders clinically acceptable outcomes in normal eyes with regular corneal shape and optics but leads to refractive error whenever the cornea is irregular in terms of anterior surface shape or anterior to posterior curvature proportions. The most prevalent conditions are keratoconus, keratoplasty, or corneas that have undergone refractive surgery, especially with old techniques. In this chapter, a more robust calculation methodology is proposed based on a three-dimensional model of the cornea constructed from tomographic data. Optical calculations are done by exact ray tracing, overcoming the limitations of the paraxial constraints and managing adequately the effect of higher-order aberrations. Image quality metrics that correlates with subjective vision will be used as a target to determine the best IOL sphere and cylinder power.
Article
Full-text available
Introduction Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. Methods In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. Conclusions Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.
Article
Full-text available
The basic merit functions of the point spread function are to increase the intensity of central maxima and elimination of side lobes or to reduce the radius of first dark ring. The point spread function of the two zone optical system of the second order in the presence of defocus and primary spherical aberration with Hanning (outer zone) and Triangular (inner zone) amplitude filters is studied. A significant increase in the intensity of central maximum when apodization parameter for β=1 is achieved. Employment of the Hanning and Triangular filters under the higher degree of primary spherical aberration and defocusing effect helps the aberrated optical systems increase the resolution thus making it a super resolver. Our aim is to improve the lateral resolution of the central peak by the highest degree of the amplitude apodization parameter β and to realize least possible radius for the first minima as the presence of first minima with zero intensity is necessary for Rayleigh criterion which can be used to study two-point resolution.
Preprint
Full-text available
PURPOSE: We search for an a priory criteria for quality of astigmatic aberrated fundus images in order to estimate minimal their details being able detected still. DESIGN: We model distortions of fundus images caused by astigmatism using computer simulation and calculate integral quality criteria of the images. SUBJECTS: High resolution fundus images from open-source databases (both healthy and with signs of diabetic retinopathy). METHODS: Under incoherent isoplanar approach we convolute initial images with system optical transfer function for simulation of distorted images. We calculate full reference quality criterion and compare it with non-reference criteria to calibrate their output for a priory quality estimation. MAIN OUTCOME MEASURES: We calibrate mentioned criteria output (in arbitrary units) against the magnitude of astigmatism in diopters (D) and the corresponding radius of optical impulse response function in micrometers (um). RESULTS: We estimate that if the magnitude of the eye astigmatism exceeds 0.7D, the minimal image details is greater than 15 um, and the output of selected non-reference criterion will be less than 20 comparing to 70 for non-distorted images. CONCLUSIONS: Mentioned approach permits using selected a priory criterion to calculate quality of astigmatic distorted fundus images and to estimate the their minimal details which maybe reliably detected.
Preprint
Full-text available
In this paper we present the attempts made for the improvement of the resolution of an optical system in the presence of higher orders of defocus and primary spherical aberration function by introducing four level asymmetric filters of Triangular, Connes, Polynomial and Hanning. Four zone aperture shading amplitude in each zone have been tested for better results. Using the above four filters placing Triangular filter in the inner zone, Connes filter in the second zone, Polynomial filter in the third zone and Hanning filter in the outer zone at higher degrees of both defocusing and primary spherical aberration situation provides the optical system to achieve super-resolver state. The highest degree of the amplitude apodization improves the lateral resolution of the central maxima and suppression of side lobes which helps to study the two point resolution.
Preprint
Full-text available
The point spread function of the optical system in the presence of defocus and primary, secondary and tertiary spherical aberration with Hanning and Connes amplitude filter is studied. A noted increase in the profile of the point spread function has been achieved. Employment of the Hanning and Connes amplitude pupil function under the higher degree of spherical aberration and defocusing effect helps the optical systems increases the resolution. The lateral resolution of the central peak is improved by the highest degree of the amplitude apodization parameter β. The presence of first minima with zero intensity necessary for Rayleigh criterion can be used to study two-point resolution.
Article
Full-text available
In order to work in a consistent way with Zernike aberration coefficients estimated in different pupils, it is necessary to refer them to a common pupil size. Two standard approaches can be used to that end: to rescale algebraically the coefficients estimated in the original pupil or to refit them anew using the wavefront slope measurements available within the new one. These procedures are not equivalent; they are affected by different estimation errors that we address in this work. Our results for normal eye populations show that in case of reducing the pupil size it is better to rescale the original coefficients than to refit them using the measurements contained within the smaller pupil. In case of enlarging the pupil size, as it can a priori be expected, the opposite holds true. We provide explicit expressions to quantify the errors arising in both cases, including the expected error incurred when extrapolating the Zernike estimation beyond the radius where the measurements were made.
Article
Full-text available
The Stiles–Crawford effect is treated as an apodization in the plane of the entrance pupil of the eye by computing the pupil function from measured values of the line spread function. The resulting apodized spread function is shown to be different from the measured spread function. The differences are in the order of 10% to 20%, but may be quite significant in the light of certain neurological phenomena.
Article
Full-text available
We present an alternative formal calculation of the scaled Zernike coefficient expansion by means of the inner product of the Zernike polynomials and the wavefront error corresponding to the scaled pupil. The relationship exhibited by the radial polynomials and Bessel functions leads to a general expression in terms of the Gauss hypergeometric function. Direct properties and index selection rules are established, and easy derivation of the non-normalized coefficients is also straightforward.
Article
Full-text available
Watson and Ahumada (2008) described a template model of visual acuity based on an ideal-observer limited by optical filtering, neural filtering, and noise. They computed predictions for selected optotypes and optical aberrations. Here we compare this model's predictions to acuity data for six human observers, each viewing seven different optotype sets, consisting of one set of Sloan letters and six sets of Chinese characters, differing in complexity (Zhang, Zhang, Xue, Liu, & Yu, 2007). Since optical aberrations for the six observers were unknown, we constructed 200 model observers using aberrations collected from 200 normal human eyes (Thibos, Hong, Bradley, & Cheng, 2002). For each condition (observer, optotype set, model observer) we estimated the model noise required to match the data. Expressed as efficiency, performance for Chinese characters was 1.4 to 2.7 times lower than for Sloan letters. Efficiency was weakly and inversely related to perimetric complexity of optotype set. We also compared confusion matrices for human and model observers. Correlations for off-diagonal elements ranged from 0.5 to 0.8 for different sets, and the average correlation for the template model was superior to a geometrical moment model with a comparable number of parameters (Liu, Klein, Xue, Zhang, & Yu, 2009). The template model performed well overall. Estimated psychometric function slopes matched the data, and noise estimates agreed roughly with those obtained independently from contrast sensitivity to Gabor targets. For optotypes of low complexity, the model accurately predicted relative performance. This suggests the model may be used to compare acuities measured with different sets of simple optotypes.
Article
Full-text available
The size of the pupil has a large effect on visual function, and pupil size depends mainly on the adapting luminance, modulated by other factors. Over the last century, a number of formulas have been proposed to describe this dependence. Here we review seven published formulas and develop a new unified formula that incorporates the effects of luminance, size of the adapting field, age of the observer, and whether one or both eyes are adapted. We provide interactive demonstrations and software implementations of the unified formula.
Article
The white-light point spread function (PSF) of the human eye is computed from monochromatic results obtained by a hybrid optical-digital procedure. The method is based on the linear recording of monochromatic aerial short-term retinal images of a point test. From these data, the monochromatic PSF is computed, and the wave aberration of the human eye is retrieved from the actual PSF by means of a phase retrieval method. The white-light PSF is generated by a digital image processing system from the monochromatic wave aberrations corresponding to three different wavelengths. The procedure proposed here allows a more complete evaluation of the optical image quality in the human eye and can be used in a variety of practical applications. As an example, the methodology is used to obtain objectively information on the reflecting layers in the retina for different incident wavelengths.
Article
Purpose: This study aimed to validate the mathematical Zernike pupil size scaling from bigger pupils to smaller pupils, and vice versa, by comparing the estimates of the Zernike coefficients with corresponding clinical measurements obtained at different pupil sizes. Methods: The i.Profiler Plus (Carl Zeiss Vision, Inc, USA) was used to obtain measures of wavefront aberrations for two pupil sizes (3 mm and the maximum natural pupil size) from the right eyes of 28 visually normal subjects (mean [±SD] age, 57 [±7] years) whose maximum pupil size was greater than or equal to 5 mm without pharmacological dilation. Zernike coefficients were estimated for a 3-mm pupil size scaling down from the measured data of the maximum natural pupil size and, similarly, for the maximum pupil size scaling up from the measured data of the 3-mm pupil. Results: The differences between the estimated and measured values were not significantly different (repeated-measures analysis of variance; p > 0.05) over the range of pupil sizes examined, irrespective of whether the estimates were made by scaling up from a small pupil or scaling down from a large pupil. However, the difference between the measured and estimated coefficients was more variable and less systematic when scaling to a larger pupil size when compared with scaling to a smaller pupil size. Conclusions: Estimation of ocular wavefront aberration coefficients either scaling down from large to smaller pupils or scaling up from smaller to large pupils provides estimates that are not significantly different from clinically measured values. However, when scaling up to a larger pupil size, the estimates are more variable. These findings have implications for pupil scaling on an individual basis, such as in cases of refractive surgery or when using pupil scaling to examine a clinical cohort.
Article
Purpose: To determine if measurement of monochromatic wavefront aberrations in near-infrared light can accurately and precisely predict subjective refractive error for polychromatic light. Our approach requires knowledge of the monochromatic wavelength-in-focus (WiF) when polychromatic light is well focused, for which new empirical measurements are reported. Methods: With accommodation paralyzed, subjective refractive error was measured as a function of wavelength using a Badal optometer by optimally focusing a letter chart illuminated with monochromatic or white light (color temperature, 4575 K). Wavelength-in-focus was determined by interpolation as that wavelength for which monochromatic refractive error matches white light refractive error. The population-based mean value of WiF, used in conjunction with the Indiana Eye model of chromatic aberration, corrected for monochromatic (842 nm) estimates of refractive error obtained from wavefront aberration measurements, predicts the absolute refractive error of individual eye for polychromatic light for comparison with empirical measurements. Results: Average WiF for eight subjects was 569 nm (SE = 3.6 nm) for a 3-mm pupil and 575 nm (SE = 3.0 nm) for an 8-mm pupil. For small (3 mm) pupils, the mean (±SD) error in predicting refractive error for white light was 0.20 (±0.05) diopters (D) (range, +0.70 to -0.46 D), and for large (>8 mm) pupils, the mean (±SD) prediction error was 0.004 (±0.12) D (range, +0.56 to -0.52 D). The population mean of prediction errors was statistically not different from zero for large pupils but was slightly hyperopic for small pupils. Conclusions: Subjective refractive error for white light can be accurately and precisely predicted objectively from monochromatic wavefront aberrations obtained for near-infrared light, but intersubject variability limits accuracy for individual subjects.
Article
Modulation transfer functions of the dioptrics of the human eye for white (equal energy distribution) light were calculated for different pupil sizes from experimental data on the aberrations. The largest aberration is the chromatic difference of focus. Since this aberration is well known quantitatively and is subject to small individual differences only, the calculated modulation transfer functions can be considered as representative for human eyes in general. The present calculations, the fundus reflection measurements of the line-spread function by Campbell and Gubisch [1], and the measurements of retinal scattering by Ohzu and Enoch [2] confirm each other. Modulation transfer functions were also calculated for just noticeable focusing errors, and may be informative on the tolerance limit to visual image quality. The calculations have been extended to the special conditions of vision at low luminances.