ArticlePDF Available

Software development for gasometric data interpretation applicable in intensive care units

Authors:

Abstract

The objective of this study was to develop a software for data interpretation of gasometric applicable in Intensive Care Units that can provide a diagnosis for disorders of acid-base balance. This is an experimental study being selected on a theoretical basis with the Java IDE NetBeans 6.8 through a partnership with professionals trained in Information Systems. The program development was based on creating an algorithm, a sequence of well-defined and unambiguous to be performed mechanically in order to provide a desired diagnosis. We created a software applicable in intensive care units called InterGas, which is a program easy to install, has an interface easy to understand and use, and to process the data quickly and accurately providing as the final diagnosis for the disorder the acid-base balance. The lack of another tool that brings together all the components of InterGas makes it a pioneering software that facilitates decision-making, as it characterizes the occurrence of mixed disturbances using compensation formulas.
A preview of the PDF is not available
ResearchGate has not been able to resolve any citations for this publication.
Article
Full-text available
Resumo: Este artigo pretende apontar alguns caminhos a serem seguidos por Gerentes de Tecnologia da Informação no ambiente corporativo. O presente estudo elaborado inicialmente visou auxiliar uma instituição pública de ensino superior, a Faculdade de Engenharia Química de Lorena. Posteriormente, o estudo recebeu incrementos com o objetivo de atender organizações dos mais diversos setores e segmentos. Palavras-chave: Engenharia de Software – Tecnologia da Informação – Sistemas de Informações Gerenciais – Estratégia e Qualidade. Introdução: Atualmente um número crescente de Empresas investe grandemente em Tecnologia de Informação (TI). Cabe salientar que a Tecnologia de Informação vai muito além do que possuir equipamentos de tecnologia avançada, ou seja, trata-se de uma ação que envolve determinadas estratégias em que vários fatores devem ser levados em consideração para que a implantação para que a mesma propicie os melhores resultados ao processo decisório. Investir em Tecnologia da Informação somente por modismo, não se preocupando com os procedimentos adequados para que isto ocorra, é um risco elevado e imensurável. A Tecnologia de Informação exige qualidade em seu desenvolvimento, principalmente na criação dos Sistemas de Informações Gerenciais. Para desenvolver tais sistemas com qualidade, a Engenharia de Software deve ser aplicada. O ambiente deve estar preparado para receber esta tecnologia e saber fazer bom uso dela. Em algumas ocasiões, é bastante complexo estabelecer uma forma para mensurar e quantificar a capacidade que a Tecnologia de Informação possui para criar valores, reduzir custos e avaliar se realmente a empresa está se tornando melhor ou mais competitiva com sua aplicação. Existem empresas que falharam no processo de aplicação da Tecnologia da Informação por falta de um planejamento ou capacitação adequada de seus colaboradores. No entanto, muitas empresas têm obtido sucesso com a sua implantação e utilização, pois a mesma agiliza o processo de tomada de decisão quando os dados são coesos e a qualidade é aplicada no desenvolvimento dos Sistemas de Informações Gerenciais. Isto ocorre quando a Tecnologia da Informação é utilizada de forma eficiente e eficaz. Para aplicar Tecnologia da Informação e obter êxito, a empresa deve planejar minuciosamente como esta será absorvida por seu ambiente. Acesse: http://www.publicacoes.fatea.br/index.php/janus/article/view/26
Article
Full-text available
Background and objectives: To correlate standard base excess (SBE) with serum lactate level and demonstrate the independent prognostic significance of each one. Methods: In a retrospective study, we retrieved data from 333 patients of our prospectively collected database of 7-bed medical intensive care unit of a 1800-bed university hospital. Results: The results have shown a poor correlation between SBE and lactate, r = - 0.358, p < 0.001, and an independent prognostic significance of each one when analyzed concomitantly, odds ratio (95% Confidence interval) = 0.996 (0.992 - 0.999) to standard base excess and 1.000 (1.000 - 1.002) to lactate at entrance; and odds ratio (95% Confidence interval ) = 0.990 (0.985 - 0.994) to standard base excess and 1.003 (1.001 - 1.005) to lactate after 24 hours. The accuracy of standard base excess was close to lactate to determine in-intensive care unit death. Conclusions: The lactic component of the metabolic acidosis is not the major determinant of standard base excess. Serum lactate and SBE are independent outcome predictors in critically ill patients.
Article
Full-text available
The field of program, services and technology evaluation in general, and in health care in particular, is going through an important growth and conceptual and methodological diversification. It is also the object of an increasing demand for its participation as an effective supportive instrument in the decision-making process, and a constant need in the dynamics of health systems and services. In this paper, based on literature review, nuclear criteria involved in the organization of all evaluation processes are identified, and articulated with the existing institutionalized evaluation practices in developed countries, that is, program evaluation, quality assessment and management and technology assessment. In conclusion, the incipient development of a methodological evaluation output in Brazil is analyzed.
Article
Full-text available
For the past 5 decades, a bicarbonate-based approach has been the dominant method used for the diagnosis and treatment of acid-base disorders. This approach, however, has been criticized by some as (1) qualitative and not quantitative in nature and (2) incapable of detecting important diagnoses. Stewart, using principals of electroneutrality and conservation of mass, developed a "new" approach to the diagnosis and management of these disorders. The proponents of Stewart's approach believe that it not only offers a mechanistic explanation for the disorders but also provides the tool to make a more accurate diagnosis. Although Stewart's approach has been largely ignored by nephrologists and renal physiologists, it is increasingly used by anesthesiologists and intensivists. This review discusses the clinical utility of Stewart's method compared with the traditional bicarbonate-based approach. Although Stewart's method proposes a different, however not new, approach, it does not improve our ability to diagnose more accurately or manage these disorders. Stewart's method also does not provide the tool to prognosticate any better than the traditional method.
Book
Pro NetBeans IDE 6 Rich Client Platform Edition is the second Apress book to cover the agile, open source NetBeans IDE platform. The book focuses on the new features of NetBeans 6 as well as what has changed since NetBeans 5.5, empowering you to be a more effective and productive developer. • Enables you to click and use any of the Java Swing and other desktop Java graphical user interface (GUI) APIs available in Java SE 6 or prior • Covers working with rich client platform features available in NetBeans for building web–based application front ends • Shows you the web–tier development plug-ins available including JSF, Struts Action Framework 2.0, and JRuby for bringing the Ruby on Rails feature set to Java via NetBeans For building back–end, server–side Java applications, pick up Pro NetBeans IDE 5.5 Enterprise Edition, which is based on APIs found in the Java EE 5.
Maintenance of plasma pH (-log10 [H+]) within the range 7.38-7.42 is an essential requirement for life, because many metabolic processes (e.g. enzymatic reactions) are exquisitely sensitive to changes in H+ concentration. The range compatible with life is 7.00-7.70 (i.e. a 5-fold change in H+ concentration). The intracellular H+ concentration is higher (about pH 7.00) than that in extracellular fluid (ECF), but is sensitive to changes in extracellular H+ concentration. ECF is normally alkaline. This narrow pH range must be maintained in the face of the production of large quantities of volatile acid from cellular metabolism (mainly CO2) and non-volatile acid from the metabolism of fats and certain proteins. The main problem encountered in the homeostatic control of plasma pH is the defence of the alkaline environment in the face of this massive, daily acid load.
Maintenance of the alkaline environment (pH∼7.4) of body fluids in the face of the production of vast quantities of acid as volatile acid (CO2) or non-volatile acids from metabolism requires defence mechanisms for both short- and long-term regulation. Short-term regulation is achieved through intracellular and extracellular buffer systems, with the main buffer system in plasma being H2CO3/HCO3– and the removal of CO2 through altered alveolar ventilation, but these can only limit the change in pH. Long-term regulation that can restore plasma pH involves regulation of renal tubular H+ secretion, the major determinant of HCO3– reabsorption, and the excretion of NH4+ and acid buffer salts, both of which result in HCO3– production by renal tubular cells. Disturbances in acid–base balance can be subdivided into those of either respiratory or metabolic (non-respiratory) origin and include both acidosis and alkalosis. As a general rule the effects of respiratory disturbances can be minimized by non-HCO3– buffer systems and corrected through changes in renal function, whereas the effects of metabolic disturbances are minimized by both HCO3– and non-HCO3– buffer systems and changes in alveolar ventilation and corrected through changes in renal function.
Article
Arterial blood gas (ABG) measurements are one of the most frequently requested laboratory examinations in critically ill patients. ABGs include measurement of pHa, PaCO2, PaO2, and oxyhemoglobin saturation. These measurements allow for assessment of the nature, progression, and severity of metabolic and respiratory disturbances.
Article
The interpretation and understanding of acid-base dysfunction has recently been revisited. The 'traditional' approach developed from the pioneering work of Henderson and Hasselbalch and is still the most widely used in clinical practice. There are a number of problems identified with this approach, however. The 'modern' approach derives from Stewart's work in physical chemistry. In this review we describe the origins of the traditional approach and discusses related concepts. We then describe Stewart's approach, including how it is derived and how it may be used to classify acid-base derangements. The applications of Stewart's approach to clinical scenarios in intensive care is then discussed briefly before we examine some published clinical studies based on his work.