Analyte volatilization procedure for the determination of low concentrations of chlorine by atmospheric-pressure helium microwave-induced plasma atomic emission spectrometry 1 This paper is published in honour of Professor C.L. Chakrabarti. 1

Department of Applied Chemistry, Osaka Prefecture University, Sakai, Ōsaka, Japan
Spectrochimica Acta Part B Atomic Spectroscopy (Impact Factor: 3.18). 07/1998; 53(6):1209-1220. DOI: 10.1016/S0584-8547(98)00147-5

ABSTRACT

A simple method is described for the generation of a continuous flow of volatile chlorine by the oxidation of aqueous chloride for the determination of low concentrations of chlorine by atmospheric-pressure helium microwave-induced plasma atomic emission spectrometry (He MIP-AES). The chlorine atom emission line at 438.976nm and ion emission lines at 479.454 and 481.006nm were selected as the analytical lines of interest. Of the various oxidation reactions investigated, two analyte volatilization reactions with potassium permanganate and perbromate in combination with sulfuric acid were found to be the most appropriate for the generation of elemental chlorine. The gaseous chlorine is separated from the solution in a simple gas–liquid separator, dried with concentrated sulfuric acid and swept into the MIP with helium carrier gas for analysis. The best attainable detection limits (3σ criterion) for chlorine at 438.976, 479.454 and 481.006nm with the use of potassium permanganate as an oxidant were found to be 29.9, 6.8 and 12.3ngml−1, respectively. Typical calibration graphs obtained under the optimized experimental conditions are rectilinear over approximately three orders of magnitude of concentration. The present method has successfully been applied to the determination of chlorine as chloride in several water samples.

0 Followers
 · 
5 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: A review is presented of developments in all aspects of atomic-emission spectrometry, including fundamental processes and instrumentation. It is noted that trends evident in the previous reviews have been maintained, particularly the impact of array detectors in many areas of study. For example, in ICP-AES applications of chemometrics and detection of transient pulses from solid sampling and coupled chromatographic techniques have benefited from the multielement detection capability afforded by array detectors. Numerous studies have been reported on various combinations of nebulizer, desolvation, axial viewing, internal standardization etc., in order to improve analytical figures of merit. Other areas of growing interest are laser ablation AES and laser-induced fluorimetry. (420 references).
    No preview · Article · Jan 1999 · Journal of Analytical Atomic Spectrometry
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: This Atomic Spectrometry Update is a new review resulting from an amalgamation of the reviews formerly appearing under the titles 'Atomic Emission Spectrometry' and 'Advances in Atomic Absorption and Fluorescence Spectrometry and Related Techniques'. An attempt has been made to address only novel and interesting developments so less emphasis has been placed on applications, which are covered in greater detail in the applications reviews, and more on technical developments. The structure of the review has been changed somewhat to keep pace with the evolution of the field. The three primary techniques of atomic absorption, emission and fluorescence spectrometry are all dealt with under each individual heading, so that 'Sample Introduction', for example, deals with sample introduction methods pertaining to all three techniques. There are now separate sections on 'Laser-based Analytical Spectrometry' and 'Coupled Techniques for Speciation Studies' to reflect the growing importance of these fields. It is hoped that these developments will result in a more integrated overview of developments in these related techniques, and any comments on the merit of this approach, or suggestions for 'fine tuning' would be welcome.
    Full-text · Article · Jan 2000 · Journal of Analytical Atomic Spectrometry
  • [Show abstract] [Hide abstract]
    ABSTRACT: A trace amount of carbon was determined by atmospheric-pressure helium microwave induced plasma atomic emission spectrometry (He-MIP-AES) with gas-phase sample introduction technique. This method was applied for the generation of a continuous flow of carbon dioxide by the acidification of carbonate ion and hydrogen carbonate ion for the determination of carbon. The generated carbon dioxide was separated from the solution by a simple gas-liquid separator, dried with a desiccant and swept into the MIP with helium carrier gas for analysis. Of the acids and drying agents investigated, hydrochloric acid for acidification and anhydrous calcium chloride as a desiccant were found to be the most appropriate for the generation of carbon dioxide. Under the optimized experimental conditions, the best attainable detection limits at C (I) 193.09 and C (I) 247.86 nm lines were 7.89 and 8.10 microg/l with linear dynamic ranges of 100 to 10,000 and 100 to 20,000 microg/l for carbon, respectively. The presence of many diverse elements and ions was found to cause a more or less depressing interference by the proposed technique. However, no interference was observed from the following elements and ions: Ca, K, Rb, Br-, Cl-, F- and I-. Finally, the present method has been applied to the determination of carbon in several water samples.
    No preview · Article · Apr 2003 · Analytical Sciences
Show more