An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals

Authors:
  • University of Zurich & University of Bern

Abstract and Figures

We present a new method for automatic detection of peaks in noisy periodic and quasi-periodic signals. The new method, called automatic multiscale-based peak detection (AMPD), is based on the calculation and analysis of the local maxima scalogram, a matrix comprising the scale-dependent occurrences of local maxima. The usefulness of the proposed method is shown by applying the AMPD algorithm to simulated and real-world signals.
Content may be subject to copyright.
Algorithms 2012, 5, 588-603; doi:10.3390/a5040588
algorithms
ISSN 1999-4893
www.mdpi.com/journal/algorithms
Article
An Efficient Algorithm for Automatic Peak Detection in Noisy
Periodic and Quasi-Periodic Signals
Felix Scholkmann *, Jens Boss and Martin Wolf
Biomedical Optics Research Laboratory, Division of Neonatology, University Hospital Zurich,
8091 Zurich, Switzerland; E-Mails: bossj@student.ethz.ch (J.B.); martin.wolf@usz.ch (M.W.)
* Author to whom correspondence should be addressed; E-Mail: felix.scholkmann@usz.ch;
Tel.: +41-(0)44-255-93-26.
Received: 3 August 2012; in revised form: 29 October 2012 / Accepted: 13 November 2012 /
Published: 21 November 2012
Abstract: We present a new method for automatic detection of peaks in noisy periodic and
quasi-periodic signals. The new method, called automatic multiscale-based peak detection
(AMPD), is based on the calculation and analysis of the local maxima scalogram, a matrix
comprising the scale-dependent occurrences of local maxima. The usefulness of
the proposed method is shown by applying the AMPD algorithm to simulated and
real-world signals.
Keywords: peak detection; local maxima scalogram; multiscale local maxima detection;
automatic multiscale-based peak detection (AMPD) algorithm
1. Introduction
The detection of peaks in signals is an important step in many signal processing applications. Up to
now, many different methods have been developed, including those based on traditional
window-threshold techniques [14], wavelet transform [513], Hilbert transform [14], combining Hilbert
and wavelet transform [15], artificial neural networks [16,17], techniques using templates [18,19],
morphology filtering [2022], nonlinear filtering [2326], Kalman filtering [27], Gabor filtering [28],
Gaussian second derivative filtering [29], linear prediction analysis [30], higher-order statistics [31],
K-Means clustering [32], fuzzy C-Means clustering [33], Empirical Mode Decomposition [34], hidden
Markov models [35], and techniques using entropy [36], momentum [37], histogram/cumulative
OPEN ACCESS
Algorithms 2012, 5
589
distribution function [38], intensity weighted variance [39], stochastic resonance [40], or a smoothed
nonlinear energy operator [41].
The problem with most of the peak detection algorithms available is that the more generally
applicable the algorithm, the more free parameters (i.e., window length or threshold value) have to be
chosen in order to be able to apply the algorithm to the signal. In contrast, algorithms with only a few
parameters are in general restricted for use in specific applications such as the detection of R-peaks in
electroencephalography (ECG) signals [1,7,8,10,12,1417,2024,3034] or peaks in chromatography
data [3,4]. Additionally the existence of noise in the analyzed signal is a challenge for many of the
peak detection algorithm available.
The unsatisfactory situation with regard to existing peak detection methods motivated the
development of a simple and effective new peak detection algorithm for noisy periodic and
quasi-periodic signals based on the insight that the general applicability of an algorithm could be
preserved by (i) using a multiscale technique to detect all local maxima of the signal and (ii) finding
the ―real peaks‖ by automatically analyzing the results of the multiscale technique applied. In
particular, the goal of our work was to develop a peak detection algorithm that has the properties of
(i) not having any free parameters values that have to be chosen by the user prior to the analysis; (ii)
being able to detect peaks in periodic and quasi-periodic signals; and (iii) having a peak detection
efficiency that is fairly robust against high and low frequency noise.
It should be noted that the goal of the present work was to develop a peak detection algorithm
specifically to detect peaks in noisy periodic and quasi-periodic signals. Thus, it was not the intention
to develop a general peak detection method that is also applicable to non-periodic signals, such as
signals normally obtained in the field of analytical chemistry, including mass spectra, optical spectra or
gas chromatograms.
2. Algorithm
Let
12
[ , , , , , ]
iN
x x x xx
be a given univariate uniformly sampled signal containing a component
of periodic or quasi-periodic peaks. The first step of the automatic multiscale-based peak detection
(AMPD) algorithm consists of calculating the local maxima scalogram (LMS). To this end, the signal
x
is first linearly detrended, i.e., the least-squares fit of a straight line to x is calculated and subtracted
from x. Then, the local maxima of the signal x are determined using a moving window approach
whereby the window length
k
w
is varied
{ 2 | 1,2, , }
k
w k k L
with k the k-th scale of the signal and
/ 2 1LN


where
z


is the ceiling function that gives the smallest integer not less than z. This is
realized for every scale
k
and for
according to
1 1 1 1
,
0,
, otherwise
i i k i i k
ki
x x x x
mr
    
 
(1)
where r is a uniformly distributed random number in the range [0, 1] and α a constant factor (α = 1).
For
1, , 1ik
, and for
2, ,i N k N  
the value r + α is assigned to
,ki
m
. These operations of
Equation 1 result in the matrix
Algorithms 2012, 5
590
1,1 1,2 1,
2,1 2,2 2, ,
,1 ,2 ,
()
N
Nki
L L L N
m m m
m m m m
m m m








M
(2)
where the k-th row contains the value for the window length
k
w
.
Thus, all elements of the L × N matrix M are in the range of [0, 1 + α]. The matrix M is called the
LMS of the signal x.
The second step of the algorithm comprises a row-wise summation of the LMS matrix M
,
1
N
k k i
im
, for
{1,2, , }kL
(3)
The vector
12
[ , , , , , ]
iL
 
γ
contains the information about the scale-dependent distribution
of zeros (and thus local maxima). The global minimum of
γ
,
argmin( )
k

, represents the scale
with the most local maxima. This value λ is used in the third step of the algorithm to reshape the LMS
matrix M by removing all elements
,ki
m
for which k > λ holds, leading to the new λ × N-matrix
,
()
ki
m
r
M
, for
{1,2, , }iN
and
{1,2, , }k
.
In the last step of the algorithm, the peaks are detected by (i) calculating the column-wise standard
deviation of the matrix
r
M
according to
1
22
,,
11
11
1
i k i k i
kk
mm












, for
{1,2, , }iN
(4)
and (ii) find all indices i for which
0
i
holds. These values are stored in the vector
ˆ
12
[ , , , , ]
qN
p p p pp
with
ˆ
N
the total number of detected peaks of the signal x. p refers to the
indices of the detected peaks. We found empirically that for quasi-periodic input signals the highest
frequency
max
()f
of the oscillation should not be larger than 4 times the lowest frequency
min
()f
, i.e.,
max min
4ff
.
Thus, using this AMPD algorithmic framework, every value of a given signal
12
[ , , , , , ]
iN
x x x xx
is detected as a peak when the column-wise standard deviation of the matrix
r
M
meet the criterion
0
i
.
Figure 1 summarizes visually the steps of the AMPD algorithm and Figure 2 shows an example of
applying the AMPD algorithm to a simulated noisy multicomponent signal
x
, defined as
12
[ , , , , , ]
iN
x x x xx
, with
1 2 3
{ sin(2 / ) sin(2 / ) sin(2 / ) }
i S S S i
x a f f b f f c f f d
 
 
for
{0,0.1, , }iN
where
800Hz
S
f
,
110Hzf
,
270Hzf
,
35Hzf
, a = 1, b = 1, c = 0.5, d = 0.1
and
a normally distributed random number in the range [0, 1].
Algorithms 2012, 5
591
Figure 1. Calculation steps of the AMPD algorithm.
Figure 2. Example of applying the AMPD algorithm to a simulated signal. (a) Local
maxima scalogram, calculated from scale 1 to L, with
/ 2 1LN


and N the length of
the signal (N = 3000); (b) Rescaled local maxima scalogram (LMS) according to the
detected global minimum as shown in (c); (d) Calculated row-wise standard deviation of
the rescaled LMS; (e) and (f) Detected peaks.
3. Validation
Two types of simulated data sets (type A and B) were created and used for the validation of the
algorithm. The first type (A) of data set was constructed to evaluate the ability of the AMPD algorithm
to detect peaks in noisy periodic signals. Therefore 5 signals (sampling frequency: 100 Hz, length:
20 s, frequency of the sinus oscillation: 1 Hz) with different amount of Gaussian white noise were
used. The signal-to-noise ratios (SNR) of the final signals were 25 dB, 10 dB, 5 dB and 0 dB.
Additionally one signal without noise was created. The SNR values were calculated according to the
Algorithms 2012, 5
592
formula
SNR 10log( / )
signal noise
PP
, with
signal
P
the power of the periodic signal and
noise
P
the power of
the noise. The second type (B) of data set was constructed to evaluate the ability of the AMPD
algorithm to detect peaks in noisy quasi-periodic signals. Therefore, five chirp signals were created,
each comprising a sinus oscillation with an increasing frequency (start frequency: 1 Hz, end frequency:
3.8 Hz). As for the type A signals, different amounts of noise were added to the signals leading to the
same SNR-values as for the type A signals.
The AMPD algorithm was implemented in Matlab (The Mathworks, Natick, MA, USA). The
results of applying the algorithm to the simulated data sets are visualised in Figures 3 and 4. All peaks
were correctly detected (based on visual inspection) for all types of signal characteristics used.
Figure 3. Results of applying the AMPD algorithm to the simulated type A data sets.
(a) no noise; (b) SNR = 25 dB; (c) SNR = 10 dB; (d) SNR = 5 dB; (e) SNR = 0 dB.
Algorithms 2012, 5
593
Figure 4. Results of applying the AMPD algorithm to the simulated type B data sets.
(a) no noise; (b) SNR = 25 dB; (c) SNR = 10 dB; (d) SNR = 5 dB; (e) SNR = 0 dB.
4. Application Examples
In this section, we present a demonstration of the proposed algorithm on five different time series
originating from different research areas (i.e., astrophysics, biomedical optics, physiology, geophysics
and chaos theory) in the field of natural sciences.
4.1. Sunspot Numbers
The time series analyzed comprises the total monthly number of sunspots, i.e., the number of dark
spots on the solar surface caused by interactions between the solar magnetic field and the Sun’s
plasma [42]. The time series comprises 3151 values and spans a period from January 1749 to July
2011. The data was downloaded from the website of the Solar Influences Data Analysis Center (SIDC)
of the Royal Observatory of Belgium (SIDC-team) [43]. The results of the analysis are given in
Figure 5. All 23 peaks were correctly detected (no false negative errors) and no false detection
occurred (no false positive errors).
Algorithms 2012, 5
594
Figure 5. Results of applying the AMPD algorithm to a time series comprising the
monthly total number of sunspots.
4.2. Blood Volume Pulse in fNIRS Signals
Signals measured using functional near-infrared spectroscopy (fNIRS) contain a strong oscillation
that is caused by the blood volume pulse (BVP) related to the arterial blood pressure changes
(systole, diastole). fNIRS is a technique allowing non-invasive measurement of changes in the blood
concentrations of oxyhemoglobin ([O2Hb]) and deoxyhemoglobin ([HHb]) by irradiating light in the
near-infrared spectrum (600950 nm) into the brain and analyzing the reflected light intensity
changes [4446]. The information of the BVP in fNIRS signals is relevant for various reasons, i.e., for
a proper removal of the BVP from fNIRS signals to improve the detection of fast neuronal optical
signals [47,48], or for the usage of a surrogate to the heart rate variability measured with
electrocardiography [49].
In order to demonstrate the applicability of the AMPD algorithm to detect the BVP-peaks in a
fNIRS time series, we used a self-recorded [O2Hb] signal measured on the prefrontal cortex
(sampling frequency: 10 Hz, source-detector distance: 2.5 mm, device: MCP-II, multichannel
continuous-wave NIR-spectroscope, for technical details see [50]). The time series analyzed had a
duration of 200 s (~3.3 min). The results of the analysis are given in Figure 6. All 225 peaks were
correctly detected (no false negative errors) and no false detection occurred (no false positive errors).
Algorithms 2012, 5
595
Figure 6. Results of applying the AMPD algorithm to a [O2Hb] time series with BVP-peaks.
4.3. Maximum Concentration of Expired CO2
The CO2 concentration of the exhaled air, measured with capnography, is an important parameter in
medicine and basic physiological research. The waveform of CO2 concentration changes during the
respiratory cycle comprises four phases (I: inspiratory baseline, II: expiratory upstroke, III: expiratory
plateau, and IV: inspiratory downstroke) where the phase IV marks the peak of the whole waveform.
This peak value is called end-tidal CO2 (PETCO2) and is a best approximation of the alveolar CO2
level, i.e., the partial pressure of CO2 in the arterial blood (PaCO2) [51]. A precise and robust
measurement of the phase IV peak is indispensable to correctly determine the PETCO2 values.
The time series analyzed comprised a 500 s long CO2 time series measured on a resting subject
(sampling frequency: 5 Hz, device: Nellcor N1000 gas analyzer, Nellcor. Inc, Hayward, USA). The
results of the analysis are given in Figure 7. All 133 peaks were correctly detected (no false negative
errors) and no false detection occurred (no false positive errors).
Algorithms 2012, 5
596
Figure 7. Results of applying the AMPD algorithm to a CO2 time series.
4.4. QRS Peaks in ECG Signals
Electrocardiography (ECG) time series contain information about the direction and magnitude of
the electrical activity caused by electrophysiological effects (depolarisation and repolarisation) of the
atria and ventricles. The time series comprises a recurrent sequence of characteristic signal waveforms
(P, QRS, T) where the QRS complex is the most striking element. The maximum of the QRS complex
is the R-peak. The sequence of RR intervals is the heart rate. The variability of the RR interval lengths
is called hart rate variability (HRV), associated with the state of the autonomic nervous system [52].
To demonstrate the usefulness of the proposed AMPD algorithm, we used a self-recorded ECG
signal (sampling frequency: 128 Hz; device: 1-channel ECG, MK3-ETA, TOM-Medical, Graz,
Austria). The analyzed time series had a duration of 200 s (~3.3 min). The results of the analysis are
given in Figure 8. All 221 R-peaks were correctly detected (no false negative errors) and no false
detection occurred (no false positive errors).
Algorithms 2012, 5
597
Figure 8. Results of applying the AMPD algorithm to an ECG time series.
4.5. Peaks in the Variation of the Earth’s Length of Day due to Lunar Tidal Forcing
Since the Earth’s rotation rate is not a constant, each day has a different duration (length of day,
LOD) when comparing the astronomically determined duration of a day on Earth with the duration of a
day according to the SI units definition (1 day = 86,400 s) measured using atomic clocks [53]. The
variations in LOD are highly non-stationary and comprise different oscillations. One of the strongest
oscillations present in the LOD time series has the average period of 13.6 days. This oscillation is the
result of a lunar tidal force that the Moon exerts on the Earth’s rotation due to changes in the lunar
declination during the lunar cycle [54].
The proposed AMPD algorithm was tested to establish its ability to detect the peaks of this
lunar-related oscillation in the unfiltered (raw) LOD data. To this end, (i) daily averaged LOD data
were obtained from the International Earth Rotation and Reference Service (IERS) [55]; and (ii) the
peaks of the LOD time series from 2008 to 2011 (1461 days) were detected. The results are given in
Figure 9. In total 105 peaks were detected. One peak was not detected (one false negative error) but no
false detection occurred (no false positive errors). As shown in Figure 9, the missed peak has low
amplitude and is superimposed with a rapidly decreasing part of a slower oscillation (low frequency
noise) which makes the detection difficult. The missed peak detection could be prevented by high-pass
filtering the signal prior to analysis with the AMPD algorithm.
Algorithms 2012, 5
598
The average duration of the intervals between the peaks was 13.7885 ± 2.1974 days, which
corresponds well with the value reported in literature [54,56].
Figure 9. Results of applying the AMPD algorithm to aLOD time series.
4.6. Chaos Theory: Lorenz System
The three-dimensional Lorenz system, developed by Edward N. Lorenz in 1963 [57], is a
simplification of the seven-dimensional system developed by Barry Salzman in 1962 [58]. The Lorenz
system is a classic example of a nonlinear system exhibiting chaotic behaviour. It is given by three
ordinary differential equations (Lorenz equations):
()
dx yx
dt

,
()
dy x z y
dt
 
,
dz xy z
dt

(5)
with the system parameters σ, ρ and β that determine the dynamic behaviour of the system.
To demonstrate the capability of the proposed AMPD algorithm, (i) the system of ordinary
differential equations given by (5) was solved for the parameter values σ = 10, ρ = 28, β = 8/3, and
[1,3000]t
; and (ii) the peaks of the time series x(t) were detected. The results are given in
Figure 10. All 53 peaks were correctly detected (no false negative errors) and no false detection
occurred (no false positive errors).
Algorithms 2012, 5
599
Figure 10. Results of applying the AMPD algorithm to the x(t) time series of the
Lorenz system.
5. Discussion and Conclusions
In this paper, we presented a new method, called automatic multiscale-based peak detection
(AMPD), for automatic detection of peaks in noisy periodic and quasi-periodic signals. Compared to
traditional methods for peak detection, the proposed AMPD algorithm has the following advantages:
(i) no free parameter values have to be chosen by the user prior to analysis; (ii) peaks in periodic and
quasi-periodic signals can be detected; and (iii) the peak detection efficiency is fairly robust against
high and low frequency noise. Hence, the presented method results in a high efficiency in detection
of peaks.
Using simulated and real-world signals, the usefulness of the AMPD algorithm was evaluated and
demonstrated. For signals with high amplitude low frequency noise, the performance of the algorithm
can be optimized by high-pass filtering the signal prior to analysis. However, the high-pass filtering is
not necessary for most of the signals as demonstrated.
For future work it would be interesting (i) to further explore the information given in the LMS in
order to find, for example, additional rules for the automatic identification of peaks; (ii) to evaluate the
performance of the AMPD algorithm compared to other peak detection algorithms available; and (iii)
to use and test the algorithm in real world applications.
Acknowledgments
The authors thank Rachel Folkes for assisting with proofreading and Patrick Wespi for his helpful
comments on the draft.
Algorithms 2012, 5
600
References
1. Pan, J.; Tompkins, W.J. A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. 1985,
32, 230236.
2. Jacobsen, A.L. Auto-Threshold peak detection in physiological signals. In Proceedings of the
23rd Annual International Conference of the IEEE, Al-Ain, United Arab Emirates, 2001;
Volume 3, pp. 21942195.
3. Vivó-Truyols, G.; Torres-Lapasió, J.R.; Van Nederkassel, A.M.; Vander Heyden, Y.; Massart, D.L.
Automatic program for peak detection and deconvolution of multi-overlapped chromatographic
signals part I: Peak detection. J. Chromatogr. A 2005, 1096, 133145.
4. Excoffier, J.L.; Guichon, G. Automatic peak detection in chromatography. Chromatographia
1982, 15, 543545.
5. Du, P.; Kibbe, W.A.; Lin, S.M. Improved peak detection in mass spectrum by incorporating
continuous wavelet transform-based pattern matching. Bioinformatics 2006, 22, 20592065.
6. Coombes, K.R.; Tsavachidis, S.; Morris, J.S.; Baggerly, K.A.; Hung, M.C.; Kuerer, H.M.
Improved peak detection and quantification of mass spectrometry data acquired from
surface-enhanced laser desorption and ionization by denoising spectra with the undecimated
discrete wavelet transform. Proteomics 2005, 5, 41074117.
7. Singh, O.; Sunkaria, R.K. A robust R-peak detection algorithm using wavelet packets. Int. J.
Comput. Appl. 2011, 36, 3743.
8. Kadambe, S.; Murray, R.; Boudreaux-Bartels, G.F. Wavelet transform-based QRS complex
detector. IEEE Trans. Biomed. Eng. 1999, 46, 838848.
9. Nenadic, Z.; Burdick, J.W. Spike detection using the continuous wavelet transform. IEEE Trans.
Biomed. Eng. 2005, 52, 7487.
10. Li, C.; Zheng, C.; Tai, C. Detection of ECG characteristic points using wavelet transforms. IEEE
Trans. Biomed. Eng. 1995, 42, 2128.
11. Gregoire, J.M.; Dale, D.; Van Dover, R.B. A wavelet transform algorithm for peak detection and
application to powder X-ray diffraction data. Rev. Sci. Instrum. 2011, 82, 18.
12. Fard, P.J.; Moradi, M.H.; Tajvidi, M.R. A novel approach in R peak detection using Hybrid
Complex Wavelet (HCW). Int. J. Cardiol. 2008, 124, 250253.
13. Wee, A.; Grayden, D.B.; Zhu, Y.; Petrkovic-Duran, K.; Smith, D. A continuous wavelet
transform algorithm for peak detection. Electrophoresis 2008, 29, 42154225.
14. Benitez, D.; Gaydecki, P.A.; Zaidi, A.; Fitzpatrick, A.P. The use of the Hilbert transform in ECG
signal analysis. Comput. Biol. Med. 2001, 31, 399406.
15. Rabbani, H.; Mahjoob, M.P.; Farahabadi, E.; Farahabadi, A. R peak detection in
electrocardiogram signal based on an optimal combination of wavelet transform, Hilbert
transform, and adaptive thresholding. J. Med. Signals Sens. 2011, 1, 9198.
16. Xue, Q.; Hu, Y.H.; Tompkins, W.J. Neural-Network-Based adaptive matched filtering for QRS
detection. IEEE Trans. Biomed. Eng. 1992, 39, 317329.
17. Vijaya, G.; Kumar, V.; Verma, H.K. ANN-Based QRS-complex analysis of ECG. J. Med. Eng. &
Technol. 1998, 22, 160167.
Algorithms 2012, 5
601
18. Mtetwa, N.; Smith, L.S. Smoothing and thresholding in neuronal spike detection. Neurocomputing
2006, 69, 13661370.
19. Andreev, V.P.; Rejtar, T.; Chen, H.S.; Moskovets, E.V.; Ivanov, A.R.; Karger, B.L. A universal
denoising and peak picking algorithm for LC-MS based on matched filtration in the
chromatographic time domain. Anal. Chem. 2003, 75, 63146326.
20. Chen, Y.; Duan, H. A QRS complex detection algorithm based on mathematical morphology and
envelope. In Proceedings of 27th Annual International Conference of the Engineering in
Medicine and Biology Society, Shanghai, China, 2006; pp. 46544657.
21. Zhang, F.; Lian, Y. QRS detection based on multiscale mathematical morphology for wearable
ECG devices in body area networks. IEEE Trans. Biomed. Circuits Syst. 2009, 3, 220228.
22. Zhang, F.; Lian, Y. QRS detection based on morphological filter and energy envelope for
applications in body sensor networks. J. Signal Proc. Syst. 2011, 64, 187194.
23. Sun, Y.; Suppappola, S.; Wrublewski, T.A. Microcontroller-Based real-time QRS detection.
Biomed. Instrum. & Technol. 1992, 26, 477484.
24. Ferdi, Y.; Herbeuval, J.P.; Charaf, A.; Boucheham, B. R wave detection using fractional digital
differentiation. ITBM-RBM 2003, 24, 273280.
25. Aboy, M.; McNames, J.; Thong, T.; Tsunami, D.; Ellenby, M.S.; Goldstein, B. An automatic beat
detection algorithm for pressure signals. IEEE Trans. Biomed. Eng. 2005, 52, 16621670.
26. Shim, B.; Min, H.; Yoon, S. Nonlinear preprocessing method for detecting peaks from gas
chromatograms. BMC Bioinf. 2009, doi:10.1186/1471-2105-10-378.
27. Tzallas, A.T.; Oikonomou, V.P.; Fotiadis, D.I. Epileptic spike detection using a Kalman filter
based approach. In Proceedings of the 28th IEEE EMBS Annual International Conference, New
York, NY, USA, 2006; pp. 501504.
28. Nguyen, N.; Huang, H.; Oraintara, S.; Vo, A. Peak detection in mass spectrometry by Gabor
filters and envelope analysis. J. Bioinf. Comput. Biol. 2009, 7, 547569.
29. Fredriksson, M.J.; Petersson, P.; Axelsson, B.O.; Bylund, D. An automatic peak finding method
for LC-MS data using Gaussian second derivative filtering. J. Seperation Sci. 2009, 32,
39063918.
30. Lin, K.-P. QRS feature extraction using linear prediction. IEEE Trans. Biomed. Eng. 1989, 36,
10501055.
31. Panoulas, K.I.; Hadjileontiadis, L.J.; Pasa, S.M. Enhancement of R-wave detection in ECG data
analysis using higher-order statistics. In Proceedings of the 23rd Annual International Conference
of the IEEE, Thessaloniki, Greece, 2001; Volume 1, pp. 344347.
32. Mehta, S.S.; Sheta, D.A.; Lingayat, N.S.; Chouhan, V.S. K-Means algorithm for the detection and
delineation of QRS-complexes in electrocardiogram. IRBM 2010, 31, 4854.
33. Sharma, S.; Mehta, S.S.; Mehta, H. Development of derivative based algorithm for the detection
of QRS-complexes in single lead electrocardiogram using FCM. IJCA 2011, 4, 1923.
34. Slimane, Z.-E.H.; Nait-Ali, A. QRS complex detection using Empirical Mode Decomposition.
Digit. Signal Proc. 2010, 20, 12211228.
35. Coast, D.A.; Stern, R.M.; Cano, G.G.; Briller, S.A. An approach to cardiac arrhythmia analysis
using hidden Markov models. IEEE Trans. Biomed. Eng. 1990, 37, 826836.
Algorithms 2012, 5
602
36. Palshikar, G. Simple algorithms for peak detection in time-series. In Proceedings of 1st IIMA
International Conference on Advanced Data Analysis, Business Analytics and Intelligence,
Ahmedabad, India, 2009.
37. Harmer, K.; Howells, G.; Sheng, W.; Fairhurst, M.; Deravi, F. A peak-trough detection algorithm
based on momentum. In Proceedings of the International Congress on Image and Signal
Processing CISP 08, Sanya, Hainan, China, 2008; Volume 4, pp. 454458.
38. Sezan, M.I. A peak detection algorithm and its application to histogram-based image data
reduction. Comput Vis. Graph. Image Proc. 1990, 49, 3651.
39. Jarman, K.H.; Daly, D.S.; Anderson, K.K.; Wahl, K.L. A new approach to automated peak
detection. Chemom. Intell. Lab. Syst. 2003, 69, 6176.
40. Deng, H.; Xiang, B.; Liao, X.; Xie, S. A linear modulation-based stochastic resonance algorithm
applied to the detection of weak chromatographic peaks. Anal. Bioanal. Chem. 2006, 386,
21992205
41. Mukhopadhyay, S.; Ray, G.C. A new interpretation of nonlinear energy operator and its efficacy
in spike detection. IEEE Trans. Biomed. Eng. 1998, 45, 180187.
42. Solanki, S.K. Sunspots: An overview. Astron. Astrophys. Rev. 2003, 11, 153286.
43. Solar Influences Data Analysis Center (SIDC) of the Royal Observatory of Belgium. Available
online: http://sidc.oma.be/DATA/monthssn.dat (accessed on 22 May 2012).
44. Mansouri, C.; Kashou, N.H. New window on optical brain imaging; medical development,
simulations and applications. In Selected Topics on Optical Fiber Technology; Yasin, M.,
Harun, S.W., Arof, H., Eds.; InTech: Rijeka, Croatia, 2012; pp. 271288.
45. Wolf, M.; Ferrari, M.; Quaresima, V. Progress of near-infrared spectroscopy and topography for
brain and muscle clinical applications. J. Biomed. Opt. 2007, doi: 10.1117/1.2804899.
46. Ferrari, M.; Quaresima, V. A brief review on the history of human functional near-infrared
spectroscopy (fNIRS) development and fields of application. Neuroimage 2012, 63, 921935.
47. Morren, G.; Wolf, M.; Lemmerling, P.; Wolf, U.; Choi, J.H.; Gratton, E.; De Lathauwer, L.;
Van Huffel, S. Detection of fast neuronal signals in the motor cortex from functional near infrared
spectroscopy measurements using independent component analysis. Med. Biol. Eng. Comput.
2004, 42, 9299.
48. Steinbrink, J.; Kempf, F.C.D.; Villringer, A.; Obrig, H. The fast optical signalrobust or elusive
when non-invasively measured in the human adult? Neuroimage 2005, 26, 9961008.
49. Trajkovic, I.; Scholkmann, F.; Wolf, M. Estimating and validating the interbeat intervals of the
heart using near-infrared spectroscopy on the human forehead. J. Biomed. Opt. 2011,
doi: 10.1117/1.3606560.
50. Haensse, D.; Szabo, P.; Brown, D.; Fauchere, J.C.; Niederer, P.; Bucher, H.U.; Wolf, M. A new
multichannel near-infrared spectro-photometry system for functional studies of the brain of adults
and neonates. Opt. Express 2005, 13, 45254538.
51. Bhavani-Shankar, K.; Moseley, H.; Kumar, A.Y.; Delph, Y. Capnometry and anaesthesia. Can. J.
Anesth. 1992, 39, 617632.
52. Rajendra Acharya, U.; Paul Joseph, K.; Kannathal, N.; Lim, C.M.; Suri, J.S. Heart rate variability:
A review. Med. Biol. Eng. Comput. 2004, 44, 10311051.
53. Wahr, J.M. The earths rotation. Ann. Rev. Earth Planet. Sci. 1988, 16, 231249.
Algorithms 2012, 5
603
54. Li, G. 27.3-day and 13.6-day atmospheric tide and lunar forcing on atmospheric circulation. Adv.
Atmos. Sci. 2005, 22, 359374.
55. International Earth Rotation and Reference Service (IERS). Available online: http://www.iers.org,
used data file: EOP 08 C04 series for 1862-2012 (IAU2000) (accessed on 29 May 2012).
56. Bellanger, E.; Blanter, E.M.; Le Mouël, J.-L.; Shnirman, M.G. Estimation of the 13.63-day lunar
tide effect on length of day. J. Geophys. Res. 2002, 107, 2102.
57. Lorenz, E.N. Deterministic nonperiodic flow. J. Atmos. Sci. 1963, 20, 130148.
58. Saltzman, B. Finite amplitude free convection as an initial value problem1. J. Atmos. Sci. 1962,
19, 329341.
© 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article
distributed under the terms and conditions of the Creative Commons Attribution license
(http://creativecommons.org/licenses/by/3.0/).
... The combined data from the clinical studies (dataset I: n = 33, dataset II: n = 25+18) resulted in total of 76 BP pairs (developed device and reference) for validation. Dataset III: This dataset contained oscillometric measurements taken simultaneously with pressure and optical sensors using the instrument III from ten volunteers (mean age 45 ± 19 years, range of [29,85] years, five women). Reference BP measurements were taken with a cuff-based NIBP monitor (Omron M3, HEM-7154-E). ...
... Furthermore, arterial waveform signals were recorded with the instrument III from 19 subjects (mean age 58 ± 19 years, range of [29,84] years), four women) under constant external pressure. Five subjects had persistent AF. ...
... Waveform feet were detected from the bandpass filtered signal (Butterworth filter with cutoff frequencies set at 0.5 and 8 Hz) using the automatic multiscale-based peak detection (AMPD) algorithm. [29,30] The detected feet were visually and independently validated by two annotators. ...
Article
Full-text available
Results from two independent clinical validation studies for measuring hemodynamics at the patient's bedside using a compact finger probe are reported. Technology comprises a barometric pressure sensor, and in one implementation, additionally, an optical sensor for photoplethysmography (PPG) is developed, which can be used to measure blood pressure and analyze rhythm, including the continuous detection of atrial fibrillation. The capabilities of the technology are shown in several form factors, including a miniaturized version resembling a common pulse oximeter to which the technology could be integrated in. Several main results are presented: i) the miniature finger probe meets the accuracy requirements of non‐invasive blood pressure instrument validation standard, ii) atrial fibrillation can be detected during the blood pressure measurement and in a continuous recording, iii) a unique comparison between optical and pressure sensing mechanisms is provided, which shows that the origin of both modalities can be explained using a pressure‐volume model and that recordings are close to identical between the sensors. The benefits and limitations of both modalities in hemodynamic monitoring are further discussed.
... In this study, the VPG signal was obtained via the first-order differentiation of the PPG signal because the peaks of the VPG have a higher detection contrast than the PPG. The AMPD [21] algorithm was used to detect peaks, as it is an adaptive frame-based peak-finding algorithm for periodic signals. As suggested by previous studies, data with peak-to-peak intervals greater than 1200 ms or less than 600 ms were excluded. ...
... CNN-LSTM: In Trial I, the classical one-dimensional 1DCNN+LSTM model was adopted, based on the methodology proposed by Mumtaz et al. This model configuration was utilized for the analysis and processing of the data in our study [21], which combines a one-dimensional convolutional neural network (CNN) with a bidirectional long-short-term memory (LSTM) network. The specific model architecture is shown in Table 2. Machine learning model: In Trial II, the extracted feature sequences were classified using machine learning techniques. ...
Article
Full-text available
Mental workload is an important predisposing factor for mental illnesses such as depression and is closely related to individual mental health. However, the suboptimal accuracy of utilizing photoplethysmography (PPG) exclusively for mental workload classification has constrained its application within pertinent professional domains. To this end, this paper proposes a signal processing method that combines continuous wavelet transform (CWT) and cardiopulmonary coupling mapping (CPC) to classify mental load via a convolutional neural network (ResAttNet). The method reflects changes in mental workload, as assessed by changes in the association between heart rate variability and respiration. In this paper, the strengths and weaknesses of this method are compared with other traditional psychological workload monitoring methods, such as heart rate variability (HRV), and its validation is performed on the publicly available dataset MAUS. The experiments show that the method is significantly better than previous machine learning methods based on heart rate variability correlation. Meanwhile, the accuracy of the method proposed in this paper reaches 80.5%, which is 6.2% higher than in previous studies. It is comparable to the result of 82.4% for the ECG-based mental workload monitoring system. Therefore, the method of combining CWT and CPC has considerable potential and provides new ideas for mental workload classification.
... The process of extracting an oscillogram from a raw wavelengthbinned PPG signal involved the following steps: i) flip the PPG signal so that the systolic peaks point up, ii) filter the signal with a 4th order zero-phase Butterworth bandpass filter with cutoff frequencies set to [0.5, 8.0], iii) extract the amplitude envelope by computing the absolute value of the Hilbert transform, iv) find the peaks from the resulting amplitude envelope with the automatic multiscale-based peak detection (AMPD) algorithm, [34] and v) calculate an 11 th -order polynomial fit on the amplitude envelope peaks to extract the final oscillogram envelope. To avoid poor fittings, each measurement was manually investigated to find the beginning and end of the oscillogram. ...
Article
Full-text available
Minimally invasive and non‐invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non‐invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time‐ and wavelength‐resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434–731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (<590 nm) probe superficial low‐pressure blood vessels, whereas longer wavelengths (>630 nm) probe high‐pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
... For the final stage of extreme value detection, we used the AMPD (automatic multiscale-based peak detection) algorithm to identify both local maxima and local minima [44]. However, it is important to note that there were instances where the algorithm did not accurately detect extreme values. ...
Article
Full-text available
PARKINSON’S disease (PD) is a neurological disorder caused by degeneration of dopaminergic neurons in the midbrain. PD patients mainly suffer from motor symptoms, which significantly impact their daily lives. The diagnostic criteria for PD include the presence of muscle rigidity, tremor, and postural reflex disturbances. The Movement Disorder Society Unified Parkinson’s Disease Rating Scale (MDS-UPDRS) is the standard tool for evaluating PD symptoms, part III of which is dedicated to motor symptoms. That part involves a comprehensive set of specific physical examinations, and physicians assign semi quantitative scores from 0 to 4. However, this approach faces notable challenges, including the requirement for movement-disorder experts proficient in using MDS-UPDRS and the presence of substantial inter rater variability even among experts. Overcoming these challenges requires a quantitative and objective assessment method. Given that the rating of motor symptoms predominantly involves assessing kinematic characteristics, the integration of sensor-based devices and machine learning techniques holds the potential to outperform human experts in symptom evaluations. This study used the Leap Motion optical motion-capture device to quantitatively measure and analyze hand movements while 45 PD patients performed the following 3 tasks from the MDS-UPDRS part III: finger tapping (FT), hand opening and closing (OC), and forearm pronation and supination (PS). Data from these tasks were collected and processed, resulting in the extraction of 31 movement patterns for each task. Additionally, 69 statistical features were extracted from each movement pattern, yielding 2139 features for each task. We subsequently employed a random forest algorithm to select the top 15% of features based on the reduction of Gini impurity. These selected features were subsequently fed into a sequential-forward-floating-selection algorithm, combined with a support vector machine, to identify relevant feature combinations and predict the severity of the motor symptoms. The classification accuracy was 87.0% for FT, 93.2% for OC, and 92.2% for PS. One-way analysis of variance identified 13 features of the OC task that were significantly more discriminative for classifying the movement disability of PD patients ( p <0.05). This study highlights the effectiveness of combining sensor-based measurements with machine learning for symptom assessment, which demonstrated performance comparable to that of expert physicians. Implementing these findings in clinical settings holds the promise of applying objective and quantitative methods for evaluating the symptoms of PD and related disorders.
... We then apply the predicted mask to the spectrogram to obtain the foreground signals. In the second stage, we first accumulate the power spectrogram corresponding to the foreground at each frame to obtain the accumulated energy map as shown in Fig. 4. Next, we utilize multiscale peak detection [26] to identify peaks within the accumulated energy map. Instances are defined as the frames situated between two peaks. ...
Preprint
Full-text available
Radar-based human activity recognition (HAR) is a popular area of research. In this paper, we investigate methods to improve the generalization of micro-Doppler-based swimming activity recognition. We identify three main challenges to this task: a small dataset lacking motion diversity, inaccurate period estimation, and inefficient network design that does not take into account the unique characteristics of spectrograms. To address the limited motion diversity, we propose a spectral data augmentation tailored for micro-Doppler spectrograms, including positive augmentations that account for physical fidelity and negative augmentations that penalize the unrealistic examples. We also investigate self-supervised pre-training to effectively use these negative augmentations. To address inaccurate period estimation, we introduce a segmentation approach based on energy distribution to handle temporal period variation. To exploit the spreading pattern of limb motion in the Doppler dimension and the continuous properties of torso motion in the temporal dimension, we design a module consisting of both 2D convolution and 1D temporal dynamic convolution to serve as a feature extractor. Our evaluation on a self-collected swimming activity recognition dataset shows that our model achieves the best classification accuracy and robustness to corruptions, even compared to much larger models and multi-domain fusion models.
Article
FCM algorithm is used to divide the ECG signal into QRS and non-QRS region. This paper presents a simple technique for automatic detection of cardiac beat (QRS-complex) in Electrocardiogram (ECG) using Fuzzy C-Means (FCM) clustering algorithm. The power line interference and baseline wander present in the ECG signal is removed using digital filtering techniques. Absolute derivative of the filtered ECG signal is calculated to enhance the QRS-complexes in the ECG signal. Algorithm performance is validated using original single lead ECG recordings from the CSE ECG database. Detection rate of 98.32% with 1.68% of false negative (FN) and 0.08% of false positive (FP) has been achieved.
Article
The efficient detection of R-peaks in electrocardiogram (ECG) signal is extremely important for its further processing with regard to cardiac health monitoring. In this paper, an efficient R-peak detection algorithm based on wavelet packets has been proposed. The wavelet packets decompose ECG signal into different frequency subbands of uniform bandwidth. The features evaluated from a set of subbands are combined with heuristic detection strategy for beat detection. The proposed R-peak detection algorithm was tested on different data records of standard data bases Fantasia database, MIT-BIH arrhythmia database and self-recorded signals. A sensitivity íµí±† íµí±’ = 100% and a positive predictivity of +P = 100% for Fantasia database and íµí±† íµí±’ = 100%, +P = 100% for self-recorded signals and íµí±† íµí±’ = 99.94%, +P = 99.93% for MIT-BIH arrhythmia database were achieved using this proposed algorithm.
Article
Spectral peak detection algorithms are often difficult to automate because they either rely on somewhat arbitrary rules, or are tuned to specific spectral peak properties. One popular approach detects peaks where signal intensities exceed some threshold. This threshold is typically set arbitrarily above the noise level or manually by the user. Intensity threshold-based methods can be sensitive to baseline variations and signal intensity. Another popular peak detection approach relies on matching the spectral intensities to a reference peak shape. This approach can be very sensitive to baseline changes and deviations from the reference peak shape. Such methods can be significantly challenged by modern analytical instrumentation where the baseline tends to drift, peaks of interest may have a low signal to noise (S/N) ratio, and no well-defined reference peak shape is available.We present a new approach for spectral peak detection that is designed to be generic and easily automated. Employing a histogram-based model for spectral intensity, peaks are detected by comparing the estimated variance of observations (the x-axis of the spectrum) to the expected variance when no peak is present inside some window of interest. We compare an implementation of this approach to two existing peak detection algorithms using a series of simulated spectra.
Article
Using a simple nonlinear analysis method (E. M. Blanter et al., submitted manuscript, 2001), we are able to observe in the length of day the 18.6-year beating of the two main fortnightly lunar tides and to measure the amplitude of the smallest one with a great accuracy. We can thus estimate the associated zonal response coefficient kappa for this period. We find kappa = 0.311 +/- 0.010.
Article
Electrocardiogram (ECG) is an important bioelectrical signal used to asses the cardiac state of a patient. It consists of a recurrent wave sequence of P-wave, QRS-complex and T-wave associated with each beat. The QRS-complex is the prominent feature of the ECG. This paper presents a simple method using K-means clustering algorithm for the detection of QRS-complexes in ECG signal. Digital filters are used to remove the power line interference and baseline wander present in the ECG signal. K-means algorithm is used to classify QRS and non-QRS-region in the ECG signal. The performance of the algorithm is validated using dataset-3 of the CSE multi-lead measurement library. Detection rate of 98.66% is obtained. The percentage of false positive and false negative is 1.14% and 1.34% respectively. The mean and standard deviation of the errors between automatic and manual annotations is calculated to validate the delineation performance of the algorithm. The onsets and offsets of the detected QRS-complexes are found well within the tolerance limits as specified by the CSE library.
Article
Earth rotation observations and their implications are surveyed. The theory of the earth's rotation is summarized. The effects of tidal friction, postglacial rebound, and decade fluctuations on length of day and polar motion are considered. Present understanding of the earth's nutation is addressed.