Speciation of Cr(VI) and Cr(III) in Water Samples by Adsorptive Stripping Voltammetry in the Presence of Pyrogallol Red Applying a Selective Accumulation Potential

International journal of electrochemical science (Impact Factor: 1.5). 11/2012; 7(11):11444 - 11455.

ABSTRACT

An adsorptive stripping voltammetric procedure for the speciation of Cr(VI) and Cr(III) in the presence of pyrogallol red (PGR) is presented. The method is based on the previous reduction of Cr(VI) to Cr(III) at the electrode surface, its complexation with PGR, and the later reduction of CrIII−PGR to CrII−PGR at −0.85 V. The effects of various operational parameters such as pH, ligand concentration (CPGR), and accumulation potential and time (Eads, tads) were optimized. These studies were carried out using individual Cr(VI) and Cr(III) solutions and also mixtures of them. The results showed that the proper choice of the adsorptive potential produces selectivity for Cr(VI) in the presence of Cr(III). At an Eads of 0.00 V only Cr(VI) produces the reduction signal of CrIII−PGR at −0.85 V, while at an Eads of −0.68 V both Cr(VI) and Cr(III) produce this signal. Total chromium was determined after oxidation of Cr(III) to Cr(VI) by UV radiation in the presence of H2O2. The concentration of Cr(III) was evaluated as the difference between total chromium and Cr(VI). Under the best experimental conditions (pH 4.5; CPGR 0.25 μmol L−1; Eads −0.68 V and tads 60 s), the peak current is proportional to the total Cr concentration up to 20.0 μg L–1, with a 3 detection limit of 0.05 μg L–1. The relative standard deviation for a Cr(VI) solution (9.8 μg L−1) was 1.8 % for six successive assays. The method was validated using synthetic sea water (ASTM D665) spiked with Cr(VI) and Cr(III), and with a certified reference water (NCS ZC76307). In this reference material total chromium was determined as Cr(III) other aliquot of reference sample was oxidized and the total chromium determined as Cr(VI). Finally, the method was applied to the determination of Cr(VI) and Cr(III) in sea water samples

Download full-text

Full-text

Available from: Nagles Edgar
  • [Show abstract] [Hide abstract]
    ABSTRACT: Chronoamperometric assays based on tyrosinase and glucose oxidase (GOx) inactivation have been developed for the monitoring of Cr(III) and Cr(VI). Tyrosinase was immobilized by crosslinking on screen-printed carbon electrodes (SPCEs) containing tetrathiafulvalene (TTF) as electron transfer mediator. The tyrosinase/SPCTTFE response to pyrocatechol is inhibited by Cr(III). This process, that is not affected by Cr(VI), allows the determination of Cr(III) with a capability of detection of 2.0±0.2μM and a reproducibility of 5.5%. GOx modified screen-printed carbon platinised electrodes (SPCPtEs) were developed for the selective determination of Cr(VI) using ferricyanide as redox mediator. The biosensor was able to discriminate two different oxidation states of chromium being able to reject Cr(III) and to detect the toxic species Cr(VI). Chronoamperometric response of the biosensor towards glucose decreases with the presence of Cr(VI), with a capability of detection of 90.5±7.6nM and a reproducibility of 6.2%. A bipotentiostatic chronoamperometric biosensor was finally developed using a tyrosinase/SPCTTFE and a GOx/SPCPtE connected in array mode for the simultaneous determination of Cr(III) and Cr(VI) in spiked tap water and in waste water from a tannery factory samples.
    No preview · Article · Jun 2014 · Analytica Chimica Acta
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The present paper describes an optimized Box-Behnken design using a catalytic-differential pulse polarograhic technique for the simultaneous determination of chromium (III) and (VI) in wastewater samples using ammonium piperidine dithiocarbamate as a complexing agent. The optimization strategy was carried out using a two level full factorial design. The results of the experimental design were based on an analysis of variance and demonstrated that only the pH, concentrations of the buffer and the complexing agent were statistically significant throughout the experiment. The optimal values for the three variables were 8.0, 0.2 mM and 5.0 mM for pH, concentrations of the buffer and the complexing agent respectively. Under optimum experimental conditions the detection limit of the proposed method was found to be 0.0841 µg L -1 while the linear range was 1.0-10.0 and 0.5-25.0 µg L -1 for chromium (III) and (VI) respectively. The present method was also applied for the simultaneous determination of chromium in the presence of some foreign ions with satisfactory analytical responses.
    Full-text · Article · Dec 2014 · International journal of electrochemical science
  • [Show abstract] [Hide abstract]
    ABSTRACT: We report, for the first time, the design and fabrication of an electrochemical ion (E-ION) sensor for highly specific detection of hexavalent chromium (Cr(VI)). Unlike previously developed electrochemical Cr(VI) sensors, the sensing mechanism relies on the previously unexplored electrocatalytic reaction between Cr(VI) and surface-immobilized methylene blue (MB). The sensor is sensitive, specific, and selective enough to be used in a synthetic aquifer sample. Like many sensors of this class, it is also reagentless, reusable, and compatible with gold-plated screen-printed carbon electrodes. Despite the difference in the sensing mechanism, this E-ION Cr(VI) sensor possesses attributes similar to other MB-based electrochemical sensors, sensors with potential for real world applications.
    No preview · Article · Feb 2015 · Analytical Chemistry
Show more