Destruction of the polar ozone layer and global climate change are proven consequences of various man-made volatile compounds of which substances used for air-conditioning systems or refrigeration units are important contributors. The Montreal and Kyoto Protocol regulate the phase-out of ozone-depleting substances and the reduction of greenhouse gas emissions. In the present work, the main focus is laid on emissions from air-conditioning (A/C) systems depending on the used refrigerants, and the comparison of life cycle assessment results by means of the Hasse Diagram Technique. Five refrigerants were ranked according to three parameters. Two Hasse Diagrams were drawn; one using the energy consumption during refrigerant production and compression of the refrigerants during operation of the A/C system, the other one additionally including the direct emissions during the total life cycle of the A/C system. According to this study, the refrigerants R152a and R290 have the smallest environmental impact. The two Hasse Diagrams clearly show that direct emissions of refrigerants are crucial within the life cycle of an A/C system. Due to its small GWP100, carbon dioxide (R744) has a better direct emission balance than hydrofluorocarbons and hydrocarbons. Next to energy and emissions values, other properties (e.g. toxicology, safety, energy efficiency…) are of importance when deciding which refrigerant can be recommended as substitute. But the more parameters are included, the more likely is it that incomparabilities in the Hasse Diagrams occur. Thus, when applying the Hasse Diagram Technique to LCA, not more than three parameters should be considered. Further studies are planned to examine the relative importance with re-spect to energy efficiency, environmental and human health of the various properties.
Content may be subject to copyright.
A preview of the PDF is not available
... Another direction is the further development of the concept of stability fields, where still many questions (e.g. how to relate different stability fields if the G-space is more than two-dimensional) are open and must quickly be solved, as the application may have direct consequences for better substitutes of refrigerants (Restrepo et al., 2007;Weckert et al., 2007). We conclude that partial order is a general applicable tool just because of its conceptual simplicity, and it seems that the concepts derived from partial order fit very well to chemical problems, as typical questions in chemistry are answered in the form of series, nephelauxetic series, soft and hardness series, series of electronegativity, etc. ...
... Another direction is the further development of the concept of stability fields, where still many questions (e.g. how to relate different stability fields if the G-space is more than two-dimensional) are open and must quickly be solved, as the application may have direct consequences for better substitutes of refrigerants (Restrepo et al., 2007;Weckert et al., 2007). We conclude that partial order is a general applicable tool just because of its conceptual simplicity, and it seems that the concepts derived from partial order fit very well to chemical problems, as typical questions in chemistry are answered in the form of series, nephelauxetic series, soft and hardness series, series of electronegativity, etc. ...
Article
This chapter discusses the nature of Hasse diagrams and presents some examples from the area of environmental chemicals and their data availability. The chapter describes the software, by which partial order from the point of view of applications can be analyzed and by which partial orders can be visualized—for example, by Hasse diagrams. The chapter focuses on the approaches of inverse quantitative structure–activity relationships (QSAR) to show that partial order in chemistry must not necessarily be restricted to evaluation. The graphical display by Hasse diagrams is attractive as long as the number of objects is not too high. The chapter concludes that partial order is a general applicable tool because of its conceptual simplicity, and the concepts derived from partial order fit very well to chemical problems, as typical questions in chemistry are answered in the form of series, nephelauxetic series, soft and hardness series, and series of electronegativity.
Article
For more than a decade, R134a has been the most widely used refrigerant in automobile air conditioners in China. Although R134a does not damage the ozone layer, it contributes to the greenhouse effect. In 2021, China officially announced its decision to accept the Kigali Amendment, which mandates the gradual replacement of hydrofluorocarbon refrigerants used in automobile air conditioners. Focusing on the replacement of R134a with R1234yf and R744 — two environment-friendly refrigerants that are currently popular in the industry — this study predicted how refrigerant replacement could impact China’s emissions under different scenarios in the future. The results showed that with automobile electrification in China, emissions from automobile air conditioners could peak in 2030 and drop to 58,300 tons of CO2 equivalents by 2045. Through relevant policy interventions, the emissions from automobile air conditioners could be reduced to 27,500 tons of CO2 equivalents by 2045 — a decrease of 52.8%. Thus, policy interventions could have a great impact on automobile air conditioner-related emissions. The research results of this study provide basic data for the subsequent formulation of relevant policies, so as to better promote the development of non-carbon greenhouse gas emission reduction in China.
Article
Total Equivalent Warming Impact (TEWI) analysis has been shown to be a useful aid to quantifying the climate change effect of potential emissions from the operation of systems that involve the use of greenhouse gases and consume energy, so generating CO2 emissions. It enables these systems to be optimized for minimum global warming impact. In previous studies1,2,3, the energies required to manufacture the greenhouse gases themselves were not included; by analogy with other chemical manufacturing processes they were assumed to be small in the context of climate change. In the work described here, climate change impacts from the energy used to produce a number of common refrigerant fluids are evaluated. These impacts are compared with the potential impact on global warming from the other components of TEWI: use and disposal of the refrigerants, including direct release into the environment. It is shown that the implications for climate change of the production of traditional refrigerants like ammonia, hydrocarbons or CFC–12 and new refrigerating fluids, such as HFC–134a, are truly insignificant in comparison with other stages of the life cycle of a refrigerator and have no role in TEWI.
Article
The comparative evaluation of environmentally significant chemicals needs at first protection goals, in order to decide, whether a chemical is a 'bad' or a 'good' one. For that decision, many detailed pieces of information are to be gathered. However increasing information per chemical hampers the comparison of chemicals with respect to the protection goals. In order to avoid arbitrary aggregation functions, which often hide valuable information, very simple elements of the theory of partial order will be applied. The result of a comparative evaluation is a Hasse diagram. Its usefulness will be shown, an analysis of data structures and the possibility to include elements of descriptive statistics is included. It is suggested to supply ranking procedures (based on aggregation functions) by the Hasse diagram technique.
Article
METEOR (METhod of Evaluation by ORder) is introduced as a new evaluation approach, based on partial order theory. METEOR combines transparent decision support and convenient tools for data analysis with the ability to include stakeholders' preferences in the decision process. The basic idea is a systematic step-by-step aggregation of indicators, including their weighting. We applied METEOR to evaluate the eco-hydrological effects of nine water management strategies upon the complex surface water system of Berlin and Potsdam, Germany. Altogether 14 river sections are defined, each of which is evaluated by a set of four hydro-chemical indicators. Aggregation of indicators was performed on two levels: spatially with respect to the river sections, and thematically to the four indicators themselves. The METEOR result is in good agreement with that obtained by the PROMETHEE approach. However, advantages of METEOR are (1) identification of sensitive steps of indicator aggregation, and (2) extraction of explanatory background information about advantages and disadvantages of scenarios. Both topics enhance the transparency of the evaluation process and thus support public acceptance of the decision.
Article
As per the Montreal Protocol, CFCs and HCFCs are being phased out. HCFC-22 is used in window air conditioners. This paper presents the experimental performance study of a window air conditioner with propane (HC-290), a natural refrigerant, as a drop-in substitute to HCFC-22. Experimental results showed that HC-290 had 6.6% lower cooling capacity for the lower operating conditions and 9.7% lower for the higher operating conditions with respect to HCFC-22. The coefficient of performance for HC-290 was 7.9% higher for the lower operating conditions and 2.8% higher for the higher operating conditions. The energy consumption of the unit with HC-290 was lower in the range 12.4–13.5% than HCFC-22. The discharge pressures for HC-290 were lower in the range 13.7–18.2% than HCFC-22. For HC-290, the pressure drop was lower than HCFC-22 in both heat exchangers.This paper also presents simulation results for the heat exchangers of an HCFC-22 window air conditioner with HC-290 as a drop-in substitute. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by NIST [National Institute of Standards and Technology. EVAP-COND: simulation models for finned-tube heat exchangers, Maryland, USA (2003). http://www2.bfrl.nist.gov/software/evap-cond/[18]]. The simulated evaporator capacities are within ±4% of the experimentally measured cooling capacities for both refrigerants. Simulation results for HC-290 and HCFC-22 are compared. The exit temperatures of HC-290 are lower by 0.3–1.2 °C in the condenser and are higher by 2.1–2.4 °C in the evaporator than HCFC-22. Evaporating pressures of HC-290 are lower by 2.1–3.3% as compared to HCFC-22. The pressure drops of HC-290 are lower in both the evaporator and the condenser as compared to HCFC-22. The outlet temperatures of air for HCFC-22 and HC-290 in both heat exchangers are nearly the same.
Article
Commercial replacement of fluorocarbons in mobile air conditioning systems (MACS) with typically HC-290/600a[60/40] and minimal precautions began in Idaho in 1993. R290/600a has low environmental impact but mixed with air is flammable and frequencies for fire, injury and cabin overpressure were predicted. No such accidents are known from 1993 to mid-2003. R290/600a suppliers consumption, representative MACS charges and charge termination frequency were used to predict yearly total MACS numbers. Mid-2002 in Australia there were 0.33×106 and at end 2002 in the USA 4.7×106 R290/600a MACS. Integrating over time gave usage for Australia to the end 2002 as 1.09×106 car-years and to mid-2003 for the USA 21.7×106 car-years. The measured US fire, injury and cabin overpressure frequencies are less than 3.2×10−7 per car year with high probability. This fire frequency is a hundred times lower than predicted because most R290/600a leaks in MACS use are effectively non flammable.
Article
When a ranking of some objects (chemicals, geographical sites, river sections, etc.) by a multicriteria analysis is of concern, then it is often difficult to find a common scale among the criteria, and therefore even the simple sorting process is performed by applying additional constraints, just to get a ranking index. However such additional constraints, often arising from normative considerations, are controversially discussed. The theory of partially ordered sets and its graphical representation (Hasse diagrams) does not need such additional information just to sort the objects. Here, the approach of using partially ordered sets is described by applying it to a battery of tests, developed by Dutka et al. In our analysis we found the following: (1) The dimension analysis of partially ordered sets suggests that, at least in the case of the 55 analyzed samples and the evaluation by the scores, developed by Dutka et al., there is a considerable redundancy with respect to ranking. The visualization of the sediment sites can be performed within a two-dimensional grid. (2) Information, obtained from the structure of the Hasse diagram: For example six classes of sediment sites have high priority, and each class exhibits a different pattern of results. (3) Loss of information, when an aggregation of test results is used in order to guarantee complete comparability among all objects. A relation between information drawn from the graphic and the uncertainty of ranking after using an aggregation is given. (4) The sensitivity analysis identifies one test as most important, namely the test for Fecal Coliforms/Escherichia coli. This means that the ranking of samples is heavily influenced by the results of this specific test.
Article
MOLGEN-QSPR is a software newly developed for use in quantitative structure property relationships (QSPR) work. It allows to import, to manually edit, or to generate chemical structures, to detect duplicate structures, to import or to manually input property values, to calculate the values of a broad pool of molecular descriptors, to establish QSPR equations (models), and using such models to predict unknown property values. In connection with the molecule generator MOLGEN, MOLGEN-QSPR is able to predict property values for all compounds in a predetermined structure space (inverse QSPR). Some of the features of MOLGEN-QSPR are demonstrated on the example of haloalkane boiling points. The data basis used here is broader than in previous studies, and the models established are both more precise and simpler than those previously reported.
TEWI Analysis for Future A/C Systems Selection
  • C Petitjean
  • M B Yahia
  • G Guyonvarch
  • R Beauvis
Petitjean, C., Yahia, M.B., Guyonvarch, G., Beauvis, R. (1999): TEWI Analysis for Future A/C Systems Selection. Alternate Refrigerant Forum, June 30, Phoenix USA.