ABSTRACT

The amount of water absorption of poly(methyl methacrylate) (PMMA) containing 0, 1, 3 and 5 wt% of an adhesive monomer, 4-methacryloxyethyl trimellitic anhydride (4-META), was measured at 7 degrees C, 37 degrees C and 60 degrees C. After the water uptake reached equilibrium in specimens, they were desorbed to obtain a constant value and the absorption process was repeated. Mass changes in the second desorption were recorded for the storage temperatures of 37 degrees C and 60 degrees C. Multiple regression analyses were conducted on three independent variables, 4-META concentration, storage temperature and absorption-desorption cycle. A statistically significant relationship was found between the maximum water uptake and 4-META concentration, while there was no relationship between the maximum water uptake and diffusion coefficient obtained using the Fick's law. The negative relationship in the latter did not support the free space theory. The significant and positive relationship between the maximum water uptake and 4-META concentration demonstrates that water molecules diffuse through the formation of a hydrogen bond at polar sites. The maximum water uptake was not influenced by temperature, while the diffusion coefficient increased with the rise in temperature. The activation energy was 41-47 and 50-53 kJ/mol in the first and second absorption tests, respectively.

  • Source
    • "Diffusion of water into resin matrices may result in the deterioration of the physical/ mechanical properties, decreasing the life expectancy of the interfaces by hydrolysis and microcrack forma- tion[19,20]. Water ingress may, however, have related beneficial effects[19,20]. Currently, endodontic materials based on various formulas such as epoxy resin, calcium hydroxide and zinc oxide-eugenol are available. Unfortunately, several studies have shown that most commercially available materials can cause mild to severe inflammatory changes in apical tissues, leading to bone destruction21222324. "
    [Show abstract] [Hide abstract]
    ABSTRACT: The toxic potential of the endodontic sealers ingredients, especially the unreacted monomer, that can irritate the periapical tissue and interfere with the healing process, thus having a negative impact on the biocompatibility of the material. The aim of this study was to evaluate the influence of three experimental endodontic sealers on cells viability in vitro. Human umbilical vein endothelial cells (HUVEC) were used. The experiments were done with solid samples and extracts of sealers in artificial saliva and water. The experiments evaluated the cytotoxicity of the residual monomers that resulted from the tested composites. The decrease in cell viability was quantified by colorimetric measurement of formazan. The components of the sealers dissolved in artificial saliva and water were determined by high performance liquid chromatography (HPLC). The HUVEC are a novelty for testing the endodontic sealers biocompatibility, with certain advantages compared to other cell types used in the literature, e.g. HELA cells, fibroblasts. The data showed that cytotoxicity was directly linked with the unreacted monomer — 2-hydroxyethyl methacrylate (HEMA) present in these composites. Two of the three formulations had little or no cytotoxic effect, which makes them suitable for further testing in order to be used in endodontic treatment.
    Full-text · Article · Aug 2013 · Central European Journal of Medicine
  • Source
    • "Thus, factors related to the increased water sorption in these adhesive systems may also explain the greater silver permeation and deposition. Water sorption into polymer networks is predominantly controlled by two main factors: resin polarity, which is dictated by the concentration of polymer polar sites available to form hydrogen bonds with water,22,23 and network topology, which is related to the density of the polymer network.22,24,25 Thus, water may diffuse freely through polymers’ nanoporosities as “unbound” water or it may diffuse tightly attached to polar domains via hydrogen bonding. "
    [Show abstract] [Hide abstract]
    ABSTRACT: To morphologically evaluate the permeability of different commercial dental adhesives using scanning electron microscopy. SEVEN ADHESIVE SYSTEMS WERE EVALUATED: one three-step system (Scotchbond Multi-Purpose - MP); one two-step self-etching primer system (Clearfil SE Bond - SE); three two-step etch-and-rinse systems (Single Bond 2 - SB; Excite - EX; One-Step - OS); and two single-step self-etching adhesives (Adper Prompt - AP; One-Up Bond F - OU). The mixture of primer and bond agents of the Clearfil SE Bond system (SE-PB) was also tested. The adhesives were poured into a brass mold (5.8 mm x 0.8 mm) and light-cured for 80 s at 650 mW/cm2. After a 24 h desiccation process, the specimens were immersed in a 50% ammoniac silver nitrate solution for tracer permeation. Afterwards, they were sectioned in ultra-fine slices, carbon-coated, and analyzed under backscattered electrons in a scanning electron microscopy. MP and SE showed slight and superficial tracer permeation. In EX, SB, and OS, permeation extended beyond the inner superficies of the specimens. SE-PB did not mix well, and most of the tracer was precipitated into the primer agent. In AP and OU, "water-trees" were observed all over the specimens. Different materials showed distinct permeability in aqueous solution. The extent of tracer permeation varied according to the composition of each material and it was more evident in the more hydrophilic and solvated ones.
    Full-text · Article · Oct 2010
  • Source
    • "The increase in strength and E-modulus in group A can be explained as being the result of ongoing polymerization and crosslinking, and the onset of physical ageing (Struik 1978, Hay 1995). For groups B and C, we assume that the slight decrease in strength and modulus between 1 week and 1 month was caused by water uptake in the cement (Ruyter and Svendsen 1980, Schmitt et al. 2004), which has a plasticizing effect (Deb et al. 1995, Akashi et al. 1999, Unemori et al. 2003). Thus, storage and testing at room temperature in the dry state, as recommended in specifications for bone cements, produces unrealistically high values compared with storage and testing under simulated body conditions. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Current specifications (standards) for preclinical testing of bone cements (ISO 5833: 2002, ASTM F451-99a) require simple mechanical testing after ageing for 24 h under dry conditions at 23 degrees C. Some bone cements have fulfilled the requirements in the specifications, and yet had inferior clinical results. Clinically, bone cements are subjected to complex loading patterns in a moist or wet environment at 37 degrees C. Thus, both the validity and the robustness of current standard testing protocols can be questioned. We examined the influence of temperature and storage medium on the properties of bone cement. We also compared the results of storage and testing under standard conditions of 23 degrees C in dry air, with the results obtained at 37 degrees C in water or plasma. The dry specimens showed an increase in strength and elastic modulus with time, while the values of the wet ones decreased. There was no difference between specimens stored in water or in plasma. Ultimate compressive strength of dry specimens after 24 h was 1.16 times higher than that of the ones stored wet, increasing to 1.34 times after 1 month, and 1.46 times after 6 months (p<0.001 for all comparisons). Testing under dry conditions-as required in current standards-always gave higher values for mechanical properties than did storage and testing under more physiological conditions. The sensitivity of test values to different environments implies that testing conditions for bone cements should be scrutinized in order to develop more relevant testing protocols that reflect the in vivo environment more closely.
    Full-text · Article · Dec 2008 · Acta Orthopaedica