Background: Conventional cannulated screws are commonly used for internal fixation in the treatment of vertical femoral neck fractures. However, the noticeably high rates of undesirable outcomes such as nonunion, malunion, avascular necrosis, and fixation failure still troubled the patients and surgeons. It is urgent to develop new cannulated scre...
Article
The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the fe...
Article
Background: Component alignment is essential to improve knee function and survival in total knee arthroplasty. However, it is still unclear whether the conformity design of tibiofemoral component can mitigate abnormal knee biomechanics caused by component malrotation. The purpose of this study was to investigate whether the sagittal/coronal confor...
Article
A micro silicone oil liquid spring was designed and manufactured in this article. The performance of the liquid spring was studied by simulation analysis and mechanical test. A self-force source power-assisted knee orthosis was designed based on the liquid spring. This power-assisted knee orthosis can convert the kinetic energy of knee flexion into...
Article
The geometric bone model of patients is an important basis for individualized biomechanical modeling and analysis, formulation of surgical planning, design of surgical guide plate, and customization of artificial joint. In this study, a rapid three-dimensional (3D) reconstruction method based on statistical shape model was proposed for femur. Combi...
Article
Posterior-stabilized total knee prostheses have been widely used in orthopedic clinical treatment of knee osteoarthritis, but the patients and surgeons are still troubled by the complications, for example severe wear and fracture of the post, as well as prosthetic loosening. Understanding the in vivo biomechanics of knee prostheses will aid in the...
Article
Background and objective: Loosening and wear are still the main problems for the failure of total ankle arthroplasty, which are closely related to the micromotion at the bone-implant interface and the contact stress and joint motions at the articular surfaces. Implant design is a key factor to influence the ankle force, motions, contact stress, an...
Article
Full-text available
Implant loosening and bearing surface wear remain the most common failure problems of total ankle arthroplasty (TAA). One of the main factors leading to these problems is the non‐physiologic design of articular surfaces. The goals of this study were to reveal the effects of the anatomical medial‐lateral borders height differences, coronal and sagit...
Article
Restoration of ankle kinematic functions is the major objective following total ankle arthroplasty (TAA). However, the clinical results of traditional ankle implants are still unsatisfactory. Anatomic ankle implant may provide better ankle kinematic functions and load distribution. In this study, the biomechanical performances between two potential...
Article
Full-text available
Ceramic mask stereolithography can fabricate ceramic parts with complex macrostructures and specific microstructures. Adding the two-dimensional material of alumina platelet crystal to the slurry make this technology possible to print the nacre like “brick-mortar” bionic microstructure ceramics or textured ceramics. However, how the curable ceramic...
Article
Aberrant knee biomechanical environment caused by the component mal-alignment of unicompartmental knee arthroplasty (UKA) could lead to knee pain and even early prosthetic failure. This study aims at quantifying the effects of the coronal mal-alignment of femoral and tibial components on biomechanics of knee joint during walking. A subject-specific...
Article
This study aims to evaluate the reconstructive stability for Paprosky III acetabular defects after total hip arthroplasty using three different reconstruction strategies with trabecular metal (TM) augments. The acetabular bone defects examined were located in the ilium, the sciatic ramus and the pubic ramus. Different scenarios of acetabular recons...
Article
Background and objective Investigating the biomechanics of cartilage could help to understand the unique load-bearing property of the cartilage and optimize the scaffold design in tissue-engineering. It is important to model the cartilage as a highly inhomogeneous fibril-reinforced biphasic material to represent its complex composition and structur...
Article
Full-text available
Anatomic total shoulder arthroplasty (ATSA) is widely used to treat the diseases of the glenohumeral (GH) joint. However, the incidence of rotator cuff tears after ATSA increases during follow-up. The effects of rotator cuff deficiencies after ATSA on the biomechanics of the GH joint are to be investigated. In this study, a musculoskeletal multibod...
Article
Full-text available
Unicompartmental knee arthroplasty has been shown to provide superior functional outcomes compared to total knee arthroplasty and have motivated development of advanced implant designs including bicruciate retaining knee arthroplasty. However, few validated frameworks are available to directly compare the effect of implant design and surgical techn...
Article
Full-text available
For pre-operative osteoarthritis (OA) patients with varus knee, previous studies showed inconsistent results. Therefore, we conducted this study to better identify the association of Hospital for Special Surgery (HSS) score and mechanical alignment. 44 patients (51 knees) with constitutional varus knee caused by combined deformities (LDFA (lateral...
Chapter
Contact mechanics analysis and wear assessment of total knee replacement (TKR) are essential for investigating potential failures of knee implants. This chapter firstly review a large number of literatures, which have introduced the structure, kinematics, and biomechanics of knee joint, the kinematics and biomechanics of knee replacement, the mater...
Chapter
This chapter highlights the computational modelling methods for biomechanics and biotribology of artificial shoulder joint. After a brief of overview of total shoulder arthroplasty, designs, clinical problems, and the development of modelling approaches, we review the major modelling methods, including musculoskeletal multibody dynamics simulation,...
Article
The motion capture and force plates data are essential inputs for musculoskeletal multibody dynamics models to predict in vivo tibiotalar contact forces. However, it could be almost impossible to obtain valid force plates data in old patients undergoing total ankle arthroplasty under some circumstances, such as smaller gait strides and inconsistent...
Article
Full-text available
Bi-cruciate retaining total knee arthroplasty has several potential advantages including improved anteroposterior knee stability compared to contemporary posterior cruciate-retaining total knee arthroplasty. However, few studies have explored whether there is significant differences of knee biomechanics following bi-cruciate retaining total knee ar...
Article
Full-text available
Flatfoot is linked to secondary lower limb joint problems, such as patellofemoral pain. This study aimed to investigate the influence of medial posting insoles on the joint mechanics of the lower extremity in adults with flatfoot. Gait analysis was performed on fifteen young adults with flatfoot under two conditions: walking with shoes and foot ort...
Article
Full-text available
Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion a...
Article
In vivo load and motion in the ankle joint play a key role in the understanding of the failure mechanism and function outcomes of total ankle arthroplasty. However, a thorough understanding of the biomechanics of the ankle joint in daily activities is lacking. The objective of this study was to develop a novel lower extremity musculoskeletal multib...
Article
Wear particle-induced osteolysis is the main reason for the long-term failure of total knee replacement. Simulator testing is the standard procedure for validating wear performance pre-clinically. The load and kinematics specified in the ISO are standard input profiles for wear testing of implants. Directions of internal-external rotation and anter...
Article
Tibial locking mechanism design is adopted to limit the backside micromotion in fixed-bearing total knee replacement. However, the effect of the interference assembly of a tibial insert on the tibiofemoral contact mechanics was usually ignored. Finite element model of a fixed-bearing total knee replacement with full peripheral locking mechanism was...
Article
Full-text available
This study aims to compare the knee morphological difference between Han and Mongolian Chinese in China. This will improve the knee prostheses design. A total of 37 natural knees of Han Chinese (13 males, 9 females) and Mongolian Chinese (8 males, 7 females) were measured used Mimics medical imaging program, and the parameters included fML (the fem...
Chapter
Ultrahigh molecular weight polyethylene (UHMWPE) remains the gold standard polymeric bearing material for use in total knee arthroplasty (TKA). However, the wear of UHMWPE inserts, the prosthetic aseptic loosening, and the osteolysis induced by wear particles limit the in vivo performance and lifetime of TKA. The loading and wear performance of UHM...
Article
Full-text available
High tibial osteotomy becomes increasingly important in the treatment of cartilage damage or osteoarthritis of the medial compartment with concurrent varus deformity. HTO produces a postoperative valgus limb alignment with shifting the load-bearing axis of the lower limb laterally. However, maximizing procedural success and postoperative knee funct...
Article
The overall objective of this study was to introduce knee joint power as a potential measure to investigate knee joint stability following total knee arthroplasty (TKA). Specific aims were to investigate whether weakened knee joint stabilizers cause abnormal kinematics and how it influences the knee joint kinetic (i.e., power) in response to pertur...
Article
Full-text available
The uses of mechanical and kinematic alignments in total knee arthroplasty are under debate in recent clinical investigations. In this study, the differences in short-term biomechanics and long-term wear volume between mechanical and kinematic alignments in total knee arthroplasty were investigated, based on a subject-specific musculoskeletal multi...
Article
Background: Meniscectomy is likely to result in an increase of joint loading on articular cartilage and initiates cartilage damages. However, the induced alterations in knee contact mechanics and secondary kinematics after the meniscal removal are still unclear during a walking gait. In this study, the role of menisci on the knee contact mechanics...
Article
Full-text available
The combination of dipole antennas and 3D diamond-structure photonic crystals is investigated by simulating method in this paper. The radiation frequency point of dipole antennas was selected to correspond to the reflection frequency point of the strongest energy in band gap. The results show that there is a good resonance performance in the range...
Article
Background: Steep inclination and excessive anteversion angles of acetabular cups could result in adverse edge-loading. This, in turn, increases contact pressure and impingement risk for traditional artificial hip joints. However, the influence of high inclination and anteversion angles on both the kinematics and contact mechanics of dual mobility...
Article
Full-text available
Detailed knowledge of the in vivo loading and kinematics in the knee joint is essential to understand its normal functions and the aetiology of osteoarthritis. Computer models provide a viable non-invasive solution for estimating joint loading and kinematics during different physiological activities. However, the joint loading and kinematics of the...
Article
Full-text available
A combined musculoskeletal multibody dynamics and finite element modeling was performed to investigate the effects of design parameters on the fracture-healing efficiency and the mechanical property of a patient-specific anatomically adjusted femoral locking plate. Specifically, the screw type, the thickness and material of the locking plate, the g...
Article
Full-text available
Ground reaction forces and moments (GRFs and GRMs) measured from force plates in a gait laboratory are usually used as the input conditions to predict the knee joint forces and moments via musculoskeletal (MSK) multibody dynamics (MBD) model. However, the measurements of the GRFs and GRMs data rely on force plates and sometimes are limited by the d...
Article
Tibiofemoral contact forces in total knee replacement have been measured at the medial and lateral sites respectively using an instrumented prosthesis, and predicted from musculoskeletal multibody dynamics models with a reasonable accuracy. However, it is uncommon that the medial and lateral forces are applied separately to replace a total axial lo...
Article
A novel wear prediction framework was developed by coupling a patient-specific lower extremity musculoskeletal multibody dynamics model with the finite element contact mechanics and wear model of total knee replacement. The tibiofemoral contact forces and kinematics were influenced by articular surface wear, and in turn, the variations from the kne...
Article
Full-text available
In vivo kinematics of total knee arthroplasty (TKA) are essential to investigate the articular surface wear of the knee implant. However, the prediction of in vivo knee kinematics and contact track during walking remains challenged. In this study, a previously developed subject-specific musculoskeletal multibody dynamics model was utilized to predi...
Article
Musculoskeletal (MSK) multibody dynamics (MBD) models have been used to predict in vivo biomechanics in total knee arthroplasty (TKA). However, a full lower limb MSK MBD modelling approach for TKA that combines subject-specific skeletal and prosthetic knee geometry has not yet been applied and evaluated over a range of patients. This study evaluate...
Article
Full-text available
Musculoskeletal lower limb models are widely used to predict the resultant contact force in the hip joint as a non-invasive alternative to instrumented implants. Previous musculoskeletal models based on rigid body assumptions treated the hip joint as an ideal sphere with only three rotational degrees of freedom. An musculoskeletal model that consid...
Article
Mal-rotation of the components in total knee arthorplasty (TKA) is a major cause of postoperative complications, with an increased propensity for implant loosening or wear leading to revision. A musculoskeletal multi-body dynamics model was used to perform a parametric study of the effects of the rotational mal-alignments in TKA on the knee loading...
Data
Full-text available
Lower extremity musculoskeletal (MSK) computational models play an important role in predicting joint forces and muscle activation simultaneously and are valuable for investigating functional outcomes of the implants. However, current computational MSK models of total knee replacement (TKR) rarely consider the bearing surface geometry of the implan...
Article
There is a growing interest in non-surgical gait rehabilitation treatments to reduce the loading in the knee joint. In particular, synergetic kinematic changes required for joint offloading should be determined individually for each subject. Previous studies for gait rehabilitation designs are typically relied on a “trial-and-error” approach, using...
Article
Full-text available
Lower extremity musculoskeletal computational models play an important role in predicting joint forces and muscle activation simultaneously and are valuable for investigating functional outcomes of the implants. However, current computational musculoskeletal models of total knee replacement rarely consider the bearing surface geometry of the implan...