Signe Johanna Vannesjo

Signe Johanna Vannesjo
Norwegian University of Science and Technology | NTNU

PhD

About

53
Publications
3,908
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
945
Citations
Citations since 2017
19 Research Items
752 Citations
2017201820192020202120222023020406080100120140
2017201820192020202120222023020406080100120140
2017201820192020202120222023020406080100120140
2017201820192020202120222023020406080100120140
Additional affiliations
January 2021 - present
Norwegian University of Science and Technology
Position
  • Associate Professor
August 2019 - July 2020
University of Zurich
Position
  • Researcher
August 2014 - August 2018
University of Oxford
Position
  • Postdoctoral research fellow

Publications

Publications (53)
Preprint
Purpose Although functional MRI is widely applied in the brain, fMRI of the spinal cord is more technically demanding. Proximity to the vertebral column and lungs results in strong spatial inhomogeneity and temporal fluctuations in B 0 . Increasing field strength enables higher spatial resolution and improved sensitivity to BOLD signal, but amplifi...
Chapter
This chapter gives an overview of artifacts caused by dynamic B0 field variations, and how to correct for the field variations retrospectively in the image reconstruction or image processing. Motion during MR acquisitions can change the B0 field in the imaging volume, by changing the magnetic susceptibility distribution. The B0 field variations int...
Preprint
Full-text available
The investigation of spontaneous fluctuations of the blood-oxygen-level-dependent (BOLD) signal has recently been extended from the brain to the spinal cord, where it has also generated initial interest from a clinical perspective. A number of resting-state functional magnetic resonance imaging (fMRI) studies have demonstrated robust functional con...
Article
Full-text available
There is emerging evidence that sampling the blood-oxygen-level-dependent (BOLD) response with high temporal resolution opens up new avenues to study the in vivo functioning of the human brain with functional magnetic resonance imaging. Because the speed of sampling and the signal level are intrinsically connected in magnetic resonance imaging via...
Article
Full-text available
Functional magnetic resonance imaging (fMRI) of the human spinal cord faces many challenges, such as signal loss due to local magnetic field inhomogeneities. This issue can be addressed with slice-specific z-shimming, which compensates for the dephasing effect of the inhomogeneities using a slice-specific gradient pulse. Here, we aim to address out...
Article
Purpose: Spinal cord gray-matter imaging is valuable for a number of applications, but remains challenging. The purpose of this work was to compare various MRI protocols at 1.5 T, 3 T, and 7 T for visualizing the gray matter. Methods: In vivo data of the cervical spinal cord were collected from nine different imaging centers. Data processing con...
Article
Full-text available
Purpose Slice-wise shimming can improve field homogeneity, but suffers from large noise propagation in the shim calculation. Here, we propose a robust shim current optimization for higher-order dynamic shim updating, based on Tikhonov regularization with a variable regularization parameter, . Theory and Methods was selected for each slice separate...
Article
Spiral imaging is very well suited for functional MRI, however its use has been limited by the fact that artifacts caused by gradient imperfections and B0 inhomogeneity are more difficult to correct compared to EPI. Effective correction requires accurate knowledge of the traversed k-space trajectory. With the goal of making spiral fMRI more accessi...
Preprint
Full-text available
Functional magnetic resonance imaging (fMRI) of the human spinal cord faces many challenges, such as signal loss due to local magnetic field inhomogeneities. This issue can be addressed with slice-specific z-shimming, which compensates for the dephasing effect of the inhomogeneities using a slice-specific gradient pulse. Here, we aim to address out...
Preprint
Full-text available
Spiral imaging is very well suited for functional MRI, however its use has been limited by the fact that artifacts caused by gradient imperfections and B 0 inhomogeneity are more difficult to correct compared to EPI. Effective correction requires accurate knowledge of the traversed k-space trajectory. With the goal of making spiral fMRI more access...
Article
MRI gradient systems are required to generate magnetic field gradient waveforms with very high fidelity. This is commonly implemented by gradient system calibration and pre-emphasis. However, a number of mechanisms, particularly thermal changes, cause variation in the gradient response over time, which cannot be addressed by calibration approaches....
Article
Full-text available
Purpose Spinal cord MRI at ultrahigh field is hampered by time‐varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi‐shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to co...
Preprint
Full-text available
Purpose: Spinal cord MRI at ultra-high field is hampered by time-varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi-shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to...
Data
Video of FLASH magnitude and field images acquired during normal free breathing in one subject. The acquisition incidentally captured one swallowing event. The corresponding ΔB0(z) is shown beneath the images, and the current time point is indicated by the dashed vertical line.
Data
Fit parameters of the skewed Gaussian model.
Article
Full-text available
Purpose: In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. Methods: The template-based prediction method uses prior knowledge of the B0 distribution in the hum...
Article
Full-text available
Magnetic resonance imaging and spectroscopy of the spinal cord stand to benefit greatly from the increased signal-to-noise ratio of ultra-high field. However, ultra-high field also poses considerable technical challenges, especially related to static and dynamic B0 fields. Breathing causes the field to fluctuate with the respiratory cycle, giving r...
Article
Magnetic resonance imaging (MRI) of the human spinal cord at 7 T has been demonstrated by a handful of research sites worldwide, and the spinal cord remains one of the areas in which higher fields and resolution could have high impact. The small diameter of the cord (∼1 cm) necessitates high spatial resolution to minimize partial volume effects bet...
Article
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and gradient components of the magnetic field were recorded with NMR field sensors. By principal component analysis it is found that differences of field evolution between the EPI...
Article
Purpose: The goal of this contribution is to enhance the fidelity and switching speed of gradient and shim fields by advancing pre-emphasis toward broadband and full cross-term correction. Theory and methods: The proposed approach is based on viewing gradient and shim chains as linear, time-invariant (LTI) systems. Pre-emphasis is accomplished b...
Article
Purpose: The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Methods: Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B0 , and coil sensitivity encoding. The enco...
Article
To calibrate a pre-emphasis to sufficiently compensate eddy currents for application of dynamic shim updating to fMRI without extension of scan times. Eddy current effects induced into all shim terms up to third-order were characterized by spatiotemporal field monitoring, using a third-order field camera. Pre-emphasis settings were derived from the...
Article
Gradient imperfections remain a challenge in MRI, especially for sequences relying on long imaging readouts. This work aims to explore image reconstruction based on k-space trajectories predicted by an impulse response model of the gradient system. Gradient characterization was performed twice with 3 years interval on a commercial 3 Tesla (T) syste...
Article
Diffusion MRI is compromised by unknown field perturbation during image encoding. The purpose of this study was to address this problem using the recently described approach of concurrent magnetic field monitoring. Magnetic field dynamics were monitored during the echo planar imaging readout of a common diffusion-weighted MRI sequence using an inte...
Article
MR image formation and interpretation relies on highly accurate dynamic magnetic fields of high fidelity. A range of mechanisms still limit magnetic field fidelity, including magnet drifts, eddy currents, and finite linearity and stability of power amplifiers used to drive gradient and shim coils. Addressing remaining errors by means of hardware, s...
Article
Full-text available
Background The accuracy of phase-contrast cardiovascular magnetic resonance (PC-CMR) can be compromised by background phase errors. It is the objective of the present work to provide an analysis of the temperature dependence of background phase errors in PC-CMR by means of gradient mount temperature sensing and magnetic field monitoring. Methods B...
Article
Applications of dynamic shimming require high field fidelity, and characterizing the shim field dynamics is therefore necessary. Modeling the system as linear and time-invariant, the purpose of this work was to measure the impulse response function with optimal sensitivity. Frequency-swept pulses as inputs are analyzed theoretically, showing that t...
Article
PurposeTo assess the utility of concurrent magnetic field monitoring for observing and correcting for variations in k-space trajectories and global background fields that occur in single-shot echo planar imaging (EPI) time series as typically used in functional MRI (fMRI).Methods Field monitoring was performed using an array of NMR field probes ope...
Article
PurposeMagnetic field fluctuations caused by subject motion, such as breathing or limb motion, can degrade image quality in brain MRI, especially at high field strengths. The purpose of this study was to investigate the feasibility of retrospectively correcting for such physiological field perturbations based on concurrent field monitoring.Theory a...
Article
We introduce matched-filter fMRI, which improves BOLD (blood oxygen-level dependent) sensitivity by variable-density image acquisition tailored to subsequent image smoothing. Image smoothing is an established post-processing technique used in the vast majority of fMRI studies. Here we show that the signal-to-noise ratio of the resulting smoothed da...
Article
Magnetic resonance spectroscopy (MRS) experiments rely on a homogeneous and stable magnetic field within the sample. Field homogeneity is typically optimized by static B0 shimming while reproducible effects from dynamic field variation are commonly diminished by means of gradient system calibration as well as calibration based on non-water suppress...
Article
PurposeMR imaging and spectroscopy require a highly stable, uniform background field. The field stability is typically limited by hardware imperfections, external perturbations, or field fluctuations of physiological origin. The purpose of the present work is to address these issues by introducing spatiotemporal field stabilization based on real-ti...
Article
This work demonstrates a fast, sensitive method of characterizing the dynamic performance of MR gradient systems. The accuracy of gradient time-courses is often compromised by field imperfections of various causes, including eddy currents and mechanical oscillations. Characterizing these perturbations is instrumental for corrections by pre-emphasis...
Article
Full-text available
Introduction: MRI relies on dynamic linear gradients for signal encoding. However the realization of given gradient time-courses is usually imperfect due to physical limitations, including limited bandwidth of gradient amplifiers, gradient chain delays, crosstalk between gradient coils, and eddy currents in the rest of the setup. Jointly, all of th...

Network

Cited By