Sara Savatović

Sara Savatović
  • PhD
  • Medical Physics Student at University of Padua

About

15
Publications
2,339
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
57
Citations
Current institution
University of Padua
Current position
  • Medical Physics Student

Publications

Publications (15)
Article
Full-text available
Phase-contrast micro-tomography (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu$$\end{document}CT) with synchrotron radiation can aid in the differentiation of s...
Preprint
Full-text available
Recent advancements in propagation-based phase-contrast imaging, such as hierarchical imaging, have enabled the visualization of internal structures in large biological specimens and material samples. However, wavefront marker-based techniques, which provide quantitative electron density information, face challenges when imaging larger objects due...
Article
Full-text available
Speckle-based imaging (SBI) is an advanced X-ray imaging technique that measures phase and dark-field signals, in addition to absorption signals. SBI uses random wavefront modulators to generate speckles and requires two images: one with a speckle pattern alone, and one with both the sample and speckles. SBI reconstruction algorithms retrieve three...
Article
Full-text available
In this study, we use synchrotron-based multi-modal X-ray tomography to examine human cerebellar tissue in three dimensions at two levels of spatial resolution (2.3 µm and 11.9 µm). We show that speckle-based imaging (SBI) produces results that are comparable to propagation-based imaging (PBI), a well-established phase-sensitive imaging method. The...
Article
Full-text available
Speckle-based imaging (SBI) is a multi-modal X-ray imaging technique that gives access to absorption, phase-contrast, and dark-field signals from a single dataset. However, it is often difficult to disentangle the different signals from a single measurement. Having complementary data obtained by repeating the scan under slightly varied conditions (...
Conference Paper
Speckle-based imaging provides complementary information through multiple imaging channels for three-dimensional visualisation of cerebellar cortex tissues. We describe a preliminary investigation of multi-resolution tomography, down to single cells, of the human cerebellum.
Article
Full-text available
Wavefront-marking X-ray imaging techniques use e.g., sandpaper or a grating to generate intensity fluctuations, and analyze their distortion by the sample in order to retrieve attenuation, phase-contrast, and dark-field information. Phase contrast yields an improved visibility of soft-tissue specimens, while dark-field reveals small-angle scatter f...
Preprint
Full-text available
Wavefront-marking X-ray imaging techniques use e.g., sandpaper or a grating to generate intensity fluctuations, and analyze their distortion by the sample in order to retrieve attenuation, phase-contrast, and dark-field information. Phase contrast yields an improved visibility of soft-tissue specimens, while dark-field reveals small-angle scatter f...
Article
Full-text available
Background Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk between the residual breast and the pectoralis fascia fo...
Poster
Full-text available
CONCLUSION The thermal dose is scattered along the two-axis finding both maximum values at 90° degrees, considering the geometrical structure of the equipment. A collimated beam is mandatory to perform a combined photoneutron therapy [1] [2].
Poster
Full-text available
Distance from isocenter [cm] BD-PND 10x10 BDT 10x10 BD-PND 1x1 BDT 1x1 LB 6411 10x10 LB 6411 1x1 narrow beam geometry 50 200 500 • ImageProPlus software Neutron dose measurements comparison from medical LINAC with different detectors Abstract ID: 128

Network

Cited By