• Home
  • Renato Aparecido Corrêa Caritá
Renato Aparecido Corrêa Caritá

Renato Aparecido Corrêa Caritá

About

32
Publications
7,715
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
137
Citations

Publications

Publications (32)
Article
New findings: What is the central question of this study? What role do neuromuscular fatigue mechanisms play in resistance training-induced adaptations of the impulse above end-test torque (IET) after the training period? What is the main finding and its importance? IET and global and peripheral fatigue were increased after a short period of resis...
Article
Full-text available
The present study aiming to verify the interference of different conditions (treadmill vs. track) on critical velocity (CV) values, as well as on the correlation to the 3000-meter performance (v3000m), and thus infer about the specificity of each values as training parameter for this distance. Seven runners (15.3±1.4 years) were submitted to a maxi...
Conference Paper
Full-text available
Usualmente, a Velocidade Crítica (VC) representa a intensidade limite do exercício sustentável, porém os perfis de resposta do V̇ O2 e da concentração de lactato sanguíneo tendem a alcançar patamares máximos, não toleráveis por período longo de tempo, quando analisados entre populações não treinadas jovens ou adultos. Assim, o presente estudo anali...
Article
Full-text available
Introduction: The respiratory compensation point (RCP) is the metabolic rate for a maximal incremental test, from which the control of the acid-base balance is lost. However, the critical velocity (CV) defines the upper limit of the heavy exercise domain, in which the exhaustion is not related to metabolic disturbance. Objective: To compare the phy...
Conference Paper
Full-text available
A prescrição individualizada do treinamento possibilita melhores respostas fisiológicas agudas e crônicas, consequentemente, aumentando a relação entre o nível de estresse e a adaptação desejada (CAPUTO & DENADAI, 2008). Assim, a determinação dos domínios de intensidade de exercício tem importantes implicações para a prescrição de treinamentos e el...
Article
Full-text available
In this study, it was hypothesized that the peak torque reliability would depend on the type of muscular action. The aim of this study was to analyze and to compare the reliability of isometric peak torque (IPT) and isokinetic peak torque at speeds of 60º.s-1 and 180°.s-1 (CPT60 and CPT180, respectively) of elbow flexors (EF) and elbow extensors (E...
Conference Paper
Full-text available
A determinação dos limiares ventilatórios (LV1 e LV2) é sensível aos procedimentos matemáticos adotados em sua determinação, o que não ocasionalmente pode fornecer parâmetros de intensidade com tendência a sub- ou superestimar a demarcação de zonas de treinamento. O objetivo deste estudo foi comparar a relação fisiológica entre três métodos de anál...
Article
Full-text available
O objetivo deste estudo foi analisar o efeito do exercício prévio severo (EPS) sobre a potência crítica (PC) e a capacidade de trabalho anaeróbio (CTA) determinados durante o exercício de ciclismo. Sete indivíduos realizaram os seguintes protocolos em cicloergômetro: (a) teste progressivo para determinação do limiar ventilatório (LV), consumo máxim...
Article
Full-text available
O efeito do treinamento sobre a cinética do VO2 no ponto de compensação respiratória (PCR) foi analisado no presente estudo. Foram avaliados 10 corredores (15,5±1,5 anos, 1,7±0,1 metros e 54,9±11,5kg) em um teste progressivo (incrementos de 1,0 km×h-1×min-1, partindo de 7,0km×h-1), determinando-se PCR e VO2max. A análise da cinética do VO2 foi real...
Article
Full-text available
The aim of this study was to investigate whether the maximal power output (Pmax) during an incremental test was dependent on the curvature constant (W′) of the power–time relationship. Thirty healthy male subjects (maximal oxygen uptake = 3.58 ± 0.40 L·min⁻¹) performed a ramp incremental cycling test to determine the maximal oxygen uptake and Pmax,...
Article
Full-text available
DOI: http://dx.doi.org/10.5007/1980-0037.2015v17n1p112 Atletas de diferentes esportes têm usado frequentemente exercícios de aquecimento como forma de preparação para a sessão de treinamento ou a competição. Entre as razões que levam os técnicos a adotarem este procedimento estão o aumento no metabolismo e na performance, como também a prevenção d...
Conference Paper
Full-text available
A determinação de parâmetros aeróbios a partir de testes diretos requer elevado custo operacional, inviabilizando a aplicação em diferentes contextos práticos e a informação específica aos treinadores. Uma alternativa é a aplicação de testes indiretos, relacionando parâmetros perceptivos e fisiológicos do esforço aos índices da aptidão aeróbia. Obj...
Conference Paper
Full-text available
Os procedimentos de determinação do Limiar Aeróbio (LAer) e Limiar Anaeróbio (LAn), correspondentes aos Limiares Ventilatórios (LV1 e LV2), apresentam diferentes procedimentos de determinação, gerando diferentes resultados, dado ao procedimento de análise. Objetivo: O presente estudo comparou três diferentes técnicas de determinação do LAer e LAn e...
Conference Paper
Full-text available
A velocidade crítica (VC) é um parâmetro da intensidade de esforço no limite do domínio pesado, e é obtida em testes retangulares. Todavia, o Ponto de Compensação Respiratória (PCR) tem sido relatado como um parâmetro correspondente à VC, porém obtido por um teste progressivo máximo. Apesar de informações fisiologias (lactacidemia e consumo de oxig...
Article
Unlabelled: Prior high-intensity exercise can improve exercise performance during severe-intensity exercise. These positive alterations have been attributed, at least in part, to enhancement of overall oxygen-uptake (VO2) kinetics. Purpose: To determine the effects of prior heavy-intensity exercise on VO2 kinetics and short-term high-intensity e...
Article
Full-text available
The purpose of this study was to determine both the independent and additive effects of prior heavy-intensity exercise and pacing strategies on the VO2 kinetics and performance during high-intensity exercise. Fourteen endurance cyclists (VO2max = 62.8±8.5 mL.kg-1.min-1) volunteered to participate in the present study with the following protocols: 1...
Article
Full-text available
INTRODUÇÃO: O exercício prévio tem importantes implicações na preparação de atletas antes de competições. OBJETIVO: Analisar o efeito de um exercício prévio realizado no domínio pesado no pico de torque (PTORQUE) medido após exercício severo. MÉTODOS: Participaram deste estudo 14 homens ativos (idade: 26 ± 4 anos, VO2max: 44 ± 6 mLO2.min⁻¹.kg⁻¹⁾...
Article
Full-text available
DOI: http://dx.doi.org/10.5007/1980-0037.2014v16n2p233 A cinética do consumo de oxigênio (VO2) e a resposta do lactato sanguíneo durante o exercício de carga constante em diferentes intensidades permitem caracterizar os domínios moderado, pesado e severo do exercício. Em exercício de intensidade constante, o perfil da resposta do VO2, analisada po...
Article
To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokine...
Article
Full-text available
INTRODUÇÃO: A determinação dos domínios de intensidade de exercício tem importantes implicações na prescrição do treino aeróbio e na elaboração de delineamentos experimentais. OBJETIVO: Analisar os efeitos do nível de aptidão aeróbia sobre a amplitude dos domínios de intensidade de exercício durante o ciclismo. MÉTODOS: Doze ciclistas (CIC), 11 cor...
Article
Full-text available
The objective was to analyze the oxygen uptake (VO2) kinetics during exercise performed at critical power (CP) in subjects with different aerobic status in cycling. Six trained cyclists (GT) and seven non-trained subjects (GNT) underwent to the following protocols in cyclergometer: (a) incremental to exhaustion to determine VO2max and its respectiv...
Article
Full-text available
The purpose of this study was to analyze the effect of recovery type (passive vs. active) during prolonged intermittent exercises on the blood lactate concentration (MLSS) and work rate (MLSSwint) at maximal lactate steady state. Nineteen male trained cyclists were divided into 2 groups for the determination of MLSSwint using passive (maximal oxyge...
Article
Full-text available
This study aimed at assessing the sensitivity of both maximal lactate steady state (MLSS) and critical power (CP) in populations of different aerobic training status to ascertain whether CP is as sensitive as MLSS to a change in aerobic fitness. Seven untrained subjects (UT) (maximal oxygen uptake = 37.4 ± 6.5 mL·kg–1·min–1) and 7 endurance cyclist...
Article
Barbosa, LF, de Souza, MR, Corrêa Caritá, RA, Caputo, F, Denadai, BS, and Greco, CC. Maximal lactate steady-state independent of recovery period during intermittent protocol. J Strength Cond Res 25(12): 3385-3390, 2011-The purpose of this study was to analyze the effect of the measurement time for blood lactate concentration ([La]) determination on...
Article
Full-text available
The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 ± 4 yr., 72.5 ± 10.6 kg, 178.5 ± 4.0 cm), performed the following tests on a cycle ergometer: (1) incremental test until volunt...
Article
Full-text available
O principal objetivo deste estudo foi comparar a intensidade correspondente à máxima fase estável de lactato (MLSS) e a potência crítica (PC) durante o ciclismo em indivíduos bem treinados. Seis ciclistas do sexo masculino (25,5 ± 4,4 anos, 68,8 ± 3,0kg, 173,0 ± 4,0cm) realizaram em diferentes dias os seguintes testes: exercício incremental até a e...
Article
The main objective of this study was to compare the intensity corresponding to the maximal lactate steady state (MLSS) and critical power (CP) in well-trained cyclists. Six male cyclists (25.5 +/- 4.4 years, 68.8 +/- 3.0 kg, 173.0 +/- 4.0 cm) performed in different days the following tests: incremental exercise test until exhaustion to determine pe...
Article
Full-text available
The objective of this study was to determine the validity of maximum lactate steady state (MLSS) for the identification of the upper limit of the heavy-intensity domain in well-trained cyclists. Fourteen male cyclists (25.5 ± 4.4 years, 69.5 ± 7.8 kg, 175.8 ± 7.5 cm) underwent the following tests on different days: incremental exercise test until e...

Network

Cited By