Research interest : Fuel cells - specific to DMFC. Presently working as Engineer In-Charge and scientific officer; Responsible for Maintenance of mechanical equipment viz pumps, heat exchangers, pressure vessels, compressors, vacuum systems, hydraulic press, piping, rubber lining, etc., and In Service Inspection of plant equipment.
Additional affiliations
August 1998 - July 2020
HWP
Position
  • Engineer
Description
  • Presently working as an EIC (Mechanical) responsible for maintenance of pumps, compressors, piping, vessels, tanks, in-service-inspection of plant components, NDT inspections, etc. Research in Direct Methanol Fuel cell area.
Education
July 2019 - July 2023
National Institute of Technology, Warangal
Field of study
  • Mechanical Engineering - Thermal Stream - Fuel Cell Technology

Publications

Publications (13)
Chapter
Experimental investigation is carried out on passive direct methanol fuel cell, to study with the selected combination of different anode and cathode current collectors which have high electrical and thermal conductivity together with corrosion resistance compatibility properties. These collectors are fabricated with an opening ratio of 45.3% on St...
Article
Full-text available
Purpose The purpose of this paper is to investigate the performance of Passive Direct Methanol Fuel Cell (PDMFC) experimentally using various Membrane Electrode Assembly (MEA) shapes such as square, rectangle, rhombus, and circle with equal areas and equal perimeters. The variation in MEA shape/size is achieved by altering gasket openings in the dy...
Article
Full-text available
Analysis of buoyancy effect on the evaluation of carbon dioxide gas from passive direct methanol fuel cell current collectors’ (CCs’) openings is carried out. Two types of setups are chosen for the analysis, one with taper cylindrical openings and the other with uniform cylindrical openings. The analysis shows that buoyancy is more effective in tap...
Article
Full-text available
To attract and get a major share of the passive direct methanol fuel cell in the global market, optimization of the influencing parameters like system durability, effectiveness, productivity, availability, and competitive price are to be balanced for achieving the excellent performance of cell for electricity generation and charging portable electr...
Chapter
Full-text available
The prime intention of this chapter is to introduce fuel cells for the sustainable energy needs of the future world. With increase in demand for electrical power globally, the need for developing a variety of renewable energy conservation is getting significant for sustainable development in the electrical power sector, keeping environmental protec...
Chapter
Full-text available
The International Energy Agency estimated that 50% of the world's electricity is being consumed by only four main equipments, viz., motors, air conditioners, refrigerators, and lighting. This chapter discusses all of this electrical equipment with respect to energy‐saving components in each of them and the application of digital technology and Inte...
Article
Full-text available
From the inception, Direct Methanol Fuel Cell (DMFC) is made suitable for various appliances which include stationary and portable electrical applications as it is considered as a notably highly promising one amongst energy sources in renewable energies. Its ion or proton conducting electrolyte is based totally on polymer electrolyte membrane (PEM)...
Article
Full-text available
Take responsibility for your own safety when you weld, cut or grind. Wear the right PPE, maintain a safe workplace and follow the safety rules that apply to your job. This article describe new ideas on safety procedures.
Article
Full-text available
ASME Boiler and Pressure vessel code (BPVC) Section VIII Division 1 is focused on a design-by-rule approach and Division 2 on design-by-analysis approach. While ASME Section VIII, Division 1's design-by-rule approach is most commonly utilized by engineers to size the pressure vessel according to the application requirements, it is quite a conservat...
Article
Full-text available
The objective of maintenance and reliability in any industry having mechanical equipment is to maintain the capability of the system while controlling costs. Maintenance is all activities involved in keeping a system's equipment in working order by implementing or improving preventive maintenance and increasing repair capability whereas Reliability...
Article
Full-text available
RMA-4 quality rubber is one of the best barrier protections between metal and acids. Rubber hardness is one of the most widely measured properties used to characterize rubber. IRHD (International Rubber Hardness Degree) scale and the Shore-A scale are two testing methods widely accepted. The two test methods use totally different indentor geometrie...

Questions

Questions (34)
Question
Good morning to all.
Can anybody help me? I am looking for Permissible uncertainty in experimental research work. Is it less than 1%?. If so, shall I get a literature support. Thank you.
Question
Surface oxidation of brass in methanol environment is observed . Is it zinc oxide or copper (cuprous) oxide or copper-meth-oxide or zinc- meth- oxide? Please help me in understanding of brass corrosion in (dilute) methanol environment of 1M to 10M concentartion.
Thank you in advance for helping me.
Question
Physical thickness of corroded iron found to be increased, whereas when we measure with ultrasonic thickness gauge, it measures less. What's the reason behind this?

Network