me Berli

me Berli
  • Doctor of Engineering
  • Professor (Associate) at National University of Entre Rios

About

40
Publications
10,835
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
86
Citations
Current institution
National University of Entre Rios
Current position
  • Professor (Associate)
Additional affiliations
January 1997 - present
National University of Entre Rios
Position
  • Research Associate

Publications

Publications (40)
Article
Full-text available
Los modelos numéricos para predecir el efecto mecánico de las prótesis de cadera en el hueso humano suelen considerar a este último como un material estático, sin cambios ante la presencia del implante. Esto limita su capacidad predictiva a largo plazo a nivel del tejido, generando dudas sobre el éxito mecánico del diseño de la prótesis. Para un an...
Article
Full-text available
This study aims to investigate the impact of hormonal imbalances during menopause, compounded by the natural ageing process, on bone health. Specifically, it examines the effects of increased bone turnover and focal bone balance on bone mass. A three-dimensional computational bone remodeling model was employed to simulate the response of the femur...
Article
The roof of a family home introduces important amounts of heat into the house. In Santa Fe city (Argentina), the attic of social family houses is not designed with thermal optimization purposes. In this work, a low Reynolds number k-e turbulent model is computationally implemented to show that a proper selection of constructive parameters of a vent...
Article
Full-text available
In this work, a computational model of thin film lubrication applied to a knee prosthesis was designed in order to make a comparison between three constitutive models, i.e. a power law, the Carreau-Yasuda model and the Cross model. The equivalent model of the knee prosthesis was modeled as a rigid cylinder on a deformable plane. The mechanical beha...
Article
Bone mechanical and biological properties are closely linked to its internal tissue composition and mass distribution, which are in turn governed by the purposeful action of the basic multicellular units (BMUs). The orchestrated action of osteoclasts and osteoblasts, the resorbing and forming tissue cells respectively, in BMUs is responsible for ti...
Article
Full-text available
Background The expression of embryonic Homeobox (HOX) genes is tightly regulated based on anatomic location in human adult dermal and synovial fibroblasts. Previously, we showed that HOX-D10,-D11 and -D13 are higher expressed in synovial fibroblasts from small distal joints from the hands and feet, in particular in digits II-V and wrists compared t...
Article
Full-text available
El proyecto FITR 009/2013 de FONARSEC-ANPCyT “Desarrollo y Prototipado de Bioimplantes Forjados” fue reconocido como proyecto PDTS por el MINCyT y se ejecuta entre la Facultad de Ingeniería de la Universidad Nacional de Entre Ríos y la empresa Implantes FICO Alemana S.A., para el diseño de un vástago de prótesis de cadera con características innova...
Article
Full-text available
En la ciudad de Santa Fe de la Vera Cruz, Argentina, se está construyendo un edificio de altura que incluye elementos de arquitectura sustentable, eficiencia energética y confort logrado en base a la utilización de recursos naturales. Particularmente, un diseño de doble fachada en los frentes que dan al exterior para lograr una cámara de aire que i...
Article
Full-text available
En el estudio de la mecánica de contacto de las articulaciones humanas, la deformación de las superficies en contacto es fundamental porque posibilita un canal por el que fluye el lubricante reduciendo el desgaste. Para determinar la validez de las predicciones de los desplazamientos de estas superficies a partir de distintos métodos, estos se apli...
Article
Full-text available
Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone...
Article
Full-text available
Ventricular assist devices are a technological solution for patients who suffer from cardiac insufficiency and await a transplant. In this work, a new design of an implantable pulsatile blood pump is analyzed in terms of blood damage, by means of finite elements on a simplified geometry. It is a double effect volumetric pump, which has a noncontact...
Article
Full-text available
Bone is a living tissue whose main mechanical function is to provide stiffness, strength and protection to the body. Both stiffness and strength depend on the mineralization of the organic matrix, which is constantly being remodelled by the coordinated action of the bone multicellular units (BMUs). Due to the dynamics of both remodelling and minera...
Data
Values of the parameter of the model presented in supporting information. (DOCX)
Data
Results of the model by using the Specific Surface from Martin [30] (?srM) and from Adams et al.(2014) measurements (?srAZ), compared with other data from Zioupos et al.[13]. Derivation of different model outputs depending on different inputs for the bone surface density function. Note that the smaller specific surface from Adams et al.[28] implies...
Data
Appendix to the main text describing the early evolution of the model. (DOCX)
Data
Apparent bone density vs ash density. Comparison of the model output to recent data in the literature. Measurements extracted from Schileo et al. [38] superimposed to numerical results derived from the present model for (?sr = 150). Note that the ash density is defined as the ratio of mineral mass to the reference bone volume (?mVm/Vt). (TIF)
Data
Histomorphometry of human elephant and human femoral cancellous samples in comparison. Plots of Tb.Th, Tb.N, Tb.Sp and BS/TV versus BV/TV. The histomorphometry of these two species is very similar and thus the full ranges of samples used here allowed us to build a more generic model. This model has been validated for the present elephant samples bu...
Article
Full-text available
Bone is a living tissue whose main mechanical function is to provide stiffness, strength and protection to the body. Both stiffness and strength depend on the mineralization of the organic matrix, which is constantly being remodelled by the coordinated action of the bone multicellular units (BMUs). Due to the dynamics of both remodelling and minera...
Article
Full-text available
The lubricated contact zone in a total knee prosthesis is modeled, where femoral and tibial components are supposed to be made of hard materials (high stiffness and hardness) and lubricated by a non Newtonian fluid (synovial liquid). To determine optimal relations among geometric parameters, load and film thickness, a generalized Reynolds equation...
Article
Full-text available
Prosthetic in-contact surfaces wear is one of the main causes of hip replacements fallure. Lubrication is essen- tial to reduce the friction and consequently the wear. A two- dimensional model based on a modified Reynolds equation, was used to aoalyze the lubricated contact In a hypothetical hip prosthesis. It is assumed that prosthesis is made of...
Conference Paper
Full-text available
Patients that suffer congestive cardiac insuffi-ciency need to be assisted with assist devices (VAD) as a temporal solution when the cardiac transplantation is not possible. For that reason it is of great interest to know the performance of such devices, especially the potential blood damage that they can produce. In this work, a computational two-...
Article
Full-text available
A preliminary study of a new pulsatile pump that will work to a frequency greater than 1 Hz, is presented. The fluid-structure interaction between a Newtonian blood flow and a piston drive that moves with periodic speed is simulated. The mechanism is of double effect and has four valves, two at the input flow and two at the output flow; the valves...
Article
Full-text available
Hip spacers are temporary implants having a geometry similar to the femoral component of a hip prosthesis, and they are manufactured with antibiotic-impregnated bone cement. The use of spacers in two stage revisions is the most effective treatment to eradicate infections and to avoid limb shortening. The most frequent complication associated with s...
Article
Full-text available
Polyethylene wear of the tibial component is recognized as the main problem limiting the duration of these implants. The difficulty of in vivo measurements of the variables that influence wear, has motivated the numerical study of theoretical models. Previous works focused on studying the lubricant film thickness, the pressure field and friction co...
Article
Full-text available
In this work the dip coating process when an insoluble surfactant is adsorbed at the interface is numerically studied. The work centers in the applicability of the linear approximation usually employed to model the relationship between surface tension and the concentration of the surface active agent. Reported solutions show that film thicknesses p...
Article
Full-text available
Atherosclerosis causes partial or total arterial blockage; this is the leading cause of death in developed coun-tries. Numerous clinical observations suggest that fluid dynamics plays an important role in the development and evolution of this disease. A research using non-invasive methods allows the systematic study without exposing people to exper...
Conference Paper
Full-text available
La enfermedad cardiovascular (ECV) es la principal causa de morbilidad y mortalidad en los países occidentales y un problema de salud pública significativo en la mayoría de las naciones industrializadas. Si bien existen tratamientos para re ducir los efectos de esta enfermedad frecuentemente a largo plazo la ECV deriva en insuficiencia cardiaca...
Article
Full-text available
Resumen— Cada año se realizan alrededor de 500.000 artroplastias o reemplazos totales de cadera en el mundo, de las cuales entre el 1 y el 4% de los casos se observan complicaciones por infección. La artroplastia de revisión en dos tiempos consiste en la colocación de un espaciador de polimetilmetacrilato (PMMA) inpregnado de antibióticos en el int...
Article
Full-text available
This work addresses the problem of heat transfer through the roof of a family home with the purpose of improving air-conditioning energy savings during hot summer days. To this end, the air natural convection in a right-angle triangular cavity, resembling an attic, is numerically analyzed. The air cavity is assumed as naturally ventilated through t...
Article
Full-text available
Tibial component of knee prostheses, made of ultra high molecular weight polyethylene (UHMWPE), experiences a high degree of wear and may be expected to last twelve years on average. In this work, a steady state one-dimensional lubrication model of a knee prosthesis is solved through a nu-merical technique based on the Finite Element Method. The mo...
Article
Full-text available
Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numeric...
Conference Paper
Full-text available
Los catéteres angioplásticos son ampliamente utilizados en el diagnóstico y tratamiento de la patología ateroesclerótica. Este tipo de afección del aparato circulatorio consiste en la reducción localizada del calibre de algunos vasos sanguíneos (en general arterias) como consecuencia de la acumulación de distintas sustancias y tipos celulares en la...
Article
The tibial component of current knee prostheses made of ultra high molecular weight polyethylene (UHMWPE) has a high degree of wear that causes knee inflammation, prosthesis loosening and subsequent replacement in not more than 15 years. In order to know which UHMWPE material properties have more influence on wear, a steady state lubrication model...
Article
Full-text available
RESUMEN La ateroesclerosis provoca obstrucción parcial o total de arterias, constituyéndose en una de las principales causas de decesos en los países desarrollados. Numerosas observaciones clínicas indican que la fluidodinámica juega un papel importante en el desarrollo y evolución de esta patología. La investigación mediante métodos no invasivos p...
Article
Full-text available
Palabras claves: Elementos finitos, prótesis de cadera, desgaste, sustrato poroso. 1 INTRODUCCIÓN Ante un estado de movimiento pleno y bajo la acción de cargas, la articulación de la cadera humana permite el movimiento relativo entre los huesos que la componen con un mínimo de fricción entre las superficies en contacto. De esta manera, se preserva...

Network

Cited By