Jungmin Kim

Jungmin Kim
  • Senior Researcher at Daewoo Shipbuilding and Marine Engineering

About

21
Publications
8,405
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
175
Citations
Introduction
Current institution
Daewoo Shipbuilding and Marine Engineering
Current position
  • Senior Researcher

Publications

Publications (21)
Article
With the continued increase in the number of pieces of diagnostic medical radiography equipment being used, radiation shielding in radiology departments is becoming increasingly important. Lead is the most commonly used material for radiation protection; however, there are numerous disadvantages associated with the use of lead, including environmen...
Article
Full-text available
The aim of the study was to evaluate dose distributions on the superficial cardiac lesion surrounded by low-density lungs. Volumetric modulated arc therapy (VMAT) technique was applied to optimize the dose distribution using the anisotropic analytic algorithm (AAA) and Acuros XB algorithm (AXB) using the 3-D printed cardiac phantom. We used four fu...
Article
Full-text available
Background: Infants admitted to neonate intensive care units (NICUs) are placed in incubators to maintain body temperature and condition, which undergo normal radiographs and are exposed to radiation. Furthermore, different incubator structures in different hospitals exhibit varying object to image receptor distance (OID), source to image receptor...
Article
Full-text available
Intra-hospital transport is associated with fatal risks for the occupants of an intensive care unit (ICU). Thus, mobile CT is used in ICUs. In this study, two-dimensional equivalent dose distribution data were expanded using the inverse square law of distance to identify the potential exposure of radiologic technologists and public and the maximum...
Article
Full-text available
Cardiac angiography to visualize the cardiac coronary artery for lesions causes a lot of radiation exposure dose to the interventional cardiologist. We evaluated the occupational radiation exposure to the interventional cardiologist based on changes to the angle of the X-ray tube used in cardiac angiography and calculated the conversion factor for...
Preprint
Full-text available
The study aimed to evaluate dose distributions on the superficial cardiac lesion surrounded by low-density lungs. We fabricated the 3-D printed cardiac phantom to insert in a multipurpose lungman phantom (KYOTO KAGAKU, Japan) for simulating a stereotactic body radiation therapy (SBRT) in ventricular tachycardia (VT) treatment. The cardiac phantom c...
Article
Full-text available
In radiography, the exposure index (EI), as per the International Electrotechnical Commission standard, depends on the incident beam quality and exposure dose to the digital radiography system. Today automatic exposure control (AEC) systems are commonly employed to obtain the optimal image quality. An AEC system can maintain a constant incident exp...
Article
The International Electrotechnical Commission introduced the concepts of exposure index (EI), target exposure index (EI T) and deviation index (DI) to manage and optimize patient dose in real time. In this study, we have proposed an appropriate method for setting the EI T based on the Korean national diagnostic reference levels (DRLs). Furthermore,...
Article
International Electrotechnical Commission (IEC) established the framework for the use of exposure index (EI) for evaluating the exposure conditions with various digital systems. In this study, we investigated the feasibility of EI, as per the IEC, by comparing the EIs obtained through manual calculated and that displayed on the console of two compu...
Article
Full-text available
Radiation dose monitoring in medical imaging examination areas is mandatory for the reduction of patient radiation exposure. Recently, dose monitoring techniques that use digital imaging and communications in medicine (DICOM) dose structured reports (SR) have been introduced. The present paper discusses the setup of a radiation dose monitoring syst...
Article
Full-text available
The purpose of this study is to investigate the feasibility of a novel indirect flat panel detector (FPD) system for removing scatter radiation. The substrate layer of our FPD system has a Pb net-like structure that matches the ineffective area and blocks the scatter radiation such that only primary X-rays reach the effective area on a thin-film tr...
Article
The radiation exposure dose must be optimised because the hazard resulting from an interventional radiology procedure is long term depending on the patient. The aim of this study was to measure the radiation doses received by the patients and medical staff during endoscopic retrograde cholangiopancreatography (ERCP) procedures. Data were collected...
Article
Full-text available
At present, concern regarding radiation exposure is increasing with the prevalence of radiologic examination. As radiation damages the human body, we have evaluated medical radiation dose values and studied the importance of optimizing radiation exposure. We measured entrance surface dose (ESD) values using a RANDO(®) phantom (neck) in 94 randomly...
Article
Full-text available
Digital cardiovascular angiography accounts for a major portion of the radiation dose among the examinations performed at cardiovascular centres. However, dose-related information is neither monitored nor recorded systemically. This report concerns the construction of a radiation dose monitoring system based on digital imaging and communications in...
Article
According to the International Electro-technical Commission, manufacturers of X-ray equipment should indicate the number of radiation doses to which a patient can be exposed. Dose–area product (DAP) meters are readily available devices that provide dose indices. Collimators are the most commonly employed radiation beam restrictors in X-ray equipmen...
Article
Full-text available
Digital radiography is often performed at a higher dose rate than analogue radiography for image acquisition. The authors measured the Entrance Surface Dose (ESD) of analogue and digital radiography techniques for 14 radiographic examinations from randomly selected medical centres in the central district of Korea. It was that the mean ESD of the d...
Article
Full-text available
A bio-anatomical quality assurance (QA) method employing tumor control probability (TCP) and normal tissue complication probability (NTCP) is described that can integrate radiobiological effects into intensity-modulated radiation therapy (IMRT). We evaluated the variations in the radiobiological effects caused by random errors (r-errors) and system...
Article
With the introduction of digital radiography, patients undergoing radiographic procedures are subject to being overexposed to radiation. Therefore, it is necessary to estimate the absorbed organ dose and the effective dose, which are significant for patient health, along with body type. During chest radiographic examinations conducted in 899 patien...
Article
Full-text available
In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm(2), respectively, were measured. In panoram...
Article
We developed a high precision position decoding method for a positron emission tomography (PET) detector that consists of a thick slab scintillator coupled with a multichannel photomultiplier tube (PMT). The DETECT2000 simulation package was used to validate light response characteristics for a 48.8 mm×48.8 mm×10 mm slab of lutetium oxyorthosilicat...

Network

Cited By