Jouke Dijkstra

Jouke Dijkstra
  • Ph.D.
  • Professor (Associate) at Leiden University Medical Centre

About

343
Publications
48,500
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
8,090
Citations
Current institution
Leiden University Medical Centre
Current position
  • Professor (Associate)

Publications

Publications (343)
Preprint
Full-text available
Liver-vessel segmentation is an essential task in the pre-operative planning of liver resection. State-of-the-art 2D or 3D convolution-based methods focusing on liver vessel segmentation on 2D CT cross-sectional views, which do not take into account the global liver-vessel topology. To maintain this global vessel topology, we rely on the underlying...
Article
Aims Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) and optical coherence tomography (OCT) can assess coronary plaque pathology but are limited by time-consuming and expertise-driven image analysis. Recently introduced machine learning(ML)-classifiers have expedited image processing, but their performance in assessing plaque pathol...
Article
Full-text available
Aims Segmental pressure gradients post-percutaneous coronary intervention (PCI) can detect residual disease and optimization targets. Ultrasonic flow ratio (UFR) or optical flow ratio (OFR) offer simultaneous physiological and morphological assessment using a single imaging catheter. This study evaluated the utility of UFR and OFR in identifying re...
Article
Background: Coronary computed tomography angiography (CCTA) has been proposed as an alternative to intravascular imaging for assessing plaque pathology. Aims: We aimed to assess the efficacy of CCTA against near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) in evaluating atheroma burden and composition and for guiding coronary inter...
Article
Full-text available
Objectives This study aimed to investigate the impact of calcific (Ca) on the efficacy of coronary computed coronary angiography (CTA) in evaluating plaque burden (PB) and composition with near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) serving as the reference standard. Materials and methods Sixty-four patients (186 vessels) were...
Article
Full-text available
Purpose The assessment of vulnerable plaque characteristics and distribution is important to stratify cardiovascular risk in a patient. Computed tomography angiography (CTA) offers a promising alternative to invasive imaging but is limited by the fact that the range of Hounsfield units (HU) in lipid-rich areas overlaps with the HU range in fibrotic...
Article
Full-text available
Background Coronary artery calcium score (CACS) is an established marker of coronary artery disease (CAD) and has been extensively used to stratify risk in asymptomatic individuals. However, the value of CACS in predicting plaque morphology in patients with advanced CAD is less established. The present analysis aims to assess the association betwee...
Article
Full-text available
Significance Near-infrared fluorescence imaging still lacks a standardized, objective method to evaluate fluorescent dye efficacy in oncological surgical applications. This results in difficulties in translation between preclinical to clinical studies with fluorescent dyes and in the reproduction of results between studies, which in turn hampers fu...
Article
Full-text available
Patients with acute coronary syndromes caused by plaque erosion might be managed conservatively without stenting. Currently, the diagnosis of plaque erosion requires an invasive imaging procedure. We sought to develop a deep learning (DL) model that enables an accurate diagnosis of plaque erosion using coronary computed tomography angiography (CTA)...
Article
Full-text available
The use of serial coronary computed tomography angiography (CCTA) allows for the early assessment of coronary plaque progression, a crucial factor in averting major adverse cardiac events (MACEs). Traditionally, serial CCTA is assessed using anatomical landmarks to match baseline and follow-up scans. Recently, a tool has been developed that allows...
Article
Full-text available
Simple Summary Thermal ablation is an established treatment for primary and secondary liver tumors. As ablation treatment planning is a fast-emerging field, accurate and patient-specific ablation zone simulation may contribute to higher efficacy of thermal ablation. Computational modeling could facilitate these simulations. This systematic review a...
Article
Background: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI....
Article
Background/Introduction Several studies have shown either favorable or unfavorable effects of dissection following drug-coated balloon (DCB) angioplasty. However, there is no established method to precisely assess the extent of dissection during DCB treatment and the relationship between dissection and late lumen gain (LLG) remains unclear. Purpos...
Article
Full-text available
Aims Coronary computed tomography angiography (CCTA) is inferior to intravascular imaging in detecting plaque morphology and quantifying plaque burden. We aim to, for the first time, train a deep-learning (DL) methodology for accurate plaque quantification and characterization in CCTA using near-infrared spectroscopy–intravascular ultrasound (NIRS–...
Article
Full-text available
Introduction Changes in coronary artery luminal dimensions during the cardiac cycle can impact the accurate quantification of volumetric analyses in intravascular ultrasound (IVUS) image studies. Accurate ED-frame detection is pivotal for guiding interventional decisions, optimizing therapeutic interventions, and ensuring standardized volumetric an...
Article
Full-text available
Advances in image reconstruction using either single or multimodality imaging data provide increasingly accurate three-dimensional (3D) patient’s arterial models for shear stress evaluation using computational fluid dynamics (CFD). We aim to evaluate the impacts on endothelial shear stress (ESS) derived from a simple image reconstruction using 3D-q...
Article
Intravascular ultrasound (IVUS) is recommended in guiding coronary intervention. The segmentation of coronary lumen and external elastic membrane (EEM) borders in IVUS images is a key step, but the manual process is time-consuming and error-prone, and suffers from inter-observer variability. In this paper, we propose a novel perceptual organisation...
Article
Full-text available
Safety and efficacy of coronary drug-eluting stents (DES) are often preclinically tested using healthy or minimally diseased swine. These generally show significant fibrotic neointima at follow-up, while in patients, incomplete healing is often observed. The aim of this study was to investigate neointima responses to DES in swine with significant c...
Article
Full-text available
Purpose: The primary objective of this study was to determine the feasibility of ablation margin quantification using a standardized scanning protocol during thermal ablation (TA) of hepatocellular carcinoma (HCC), and a rigid registration algorithm. Secondary objectives were to determine the inter- and intra-observer variability of tumor segmenta...
Article
Full-text available
Introduction: To minimize the risk of local tumor progression after thermal ablation of liver malignancies, complete tumor ablation with sufficient ablation margins is a prerequisite. This has resulted in ablation margin quantification to become a rapidly evolving field. The aim of this systematic review is to give an overview of the available lit...
Preprint
Background Complete vessel reconstruction (CVR) with incorporation of side branches is essential for accurate evaluation of wall shear stress (WSS) distribution. However, CVR is time consuming and blood flow simulation is computationally expensive, while there is no evidence that WSS computed by CVR, enables better prediction of disease progression...
Article
Full-text available
Endothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative coronary artery bypass graft are yet unclear. This report aims to examine the interplay between ESS and the morphological alterations of a biorestorative c...
Article
Aims: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). Methods and results: A total of...
Article
Objectives: The objective of the present study was to compare plaque burden (PB) calculated from optical coherence tomography (OCT) using deep learning (DL) with PB derived from co-registered intravascular ultrasound (IVUS). Background: A DL algorithm was developed for automated plaque characterization and PB quantification from OCT images. Howe...
Article
Full-text available
Background: The optical coherence tomography (OCT)-deep learning (DL) emerged as a promising tool for automated plaque characterization. However, its findings have not been compared with optical and ultrasound signals. Objectives: The objective was to cross-validate the calcified plaque detected by OCT-DL, using comprehensive tissue characterizatio...
Article
Full-text available
Vascular inflammation, lipid metabolism, and thrombogenicity play a key role not only in atherogenesis but also in the development of acute coronary syndromes. Biomarkers associated with coronary high-risk plaques defined according to intravascular imaging have not been systematically studied. A total of 69 patients with coronary artery disease who...
Article
Introduction Use of serial coronary computed tomography angiography (CCTA) allows for the early assessment of coronary plaque progression which may aid in the prevention of major adverse cardiac events (MACE). However, assessment of serial CCTA is done by using anatomical landmarks for matching baseline and follow-up scans. Recently, a tool has bee...
Article
Full-text available
Purpose To assess the quantitative minimal ablation margin (MAM) in patients with colorectal liver metastases (CRLM) treated with percutaneous thermal ablation (TA) and correlate the quantitative MAM with local tumour recurrence (LTR). Method Thirty-nine of 143 patients with solitary or multiple CRLM who underwent a first percutaneous TA procedure...
Conference Paper
Objective We developed and validated a novel deep-learning (DL)-methodology for coronary CT angiography (CCTA) plaque quantification and characterisation trained using near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS). Methods Seventy patients with stable angina were prospectively recruited, and underwent 3rd generation, dual-source...
Article
Background Advances in coronary computed tomography angiography (CCTA) reconstruction algorithms are expected to enhance the accuracy of CCTA plaque quantification. We aim to evaluate different CCTA reconstruction approaches in assessing vessel characteristics in coronary atheroma using intravascular ultrasound (IVUS) as the reference standard. Me...
Article
Full-text available
Background The relationship between gut microbiota and in vivo coronary plaque characteristics has not been reported. This study was conducted to investigate the relationship between gut microbiota and coronary plaque characteristics in patients with coronary artery disease. Methods and Results Patients who underwent both optical coherence tomogra...
Article
Full-text available
Background: Robotic liver surgery represents the most recent evolution in the field of minimally-invasive liver surgery. For planning and guidance of liver resections, surgeons currently rely on preoperative 2-dimensional (2D) CT and/or MR imaging and intraoperative ultrasonography. Translating 2D images into digital 3-dimensional (3D) models may i...
Article
Full-text available
Patient-specific coronary endothelial shear stress (ESS) calculations using Newtonian and non-Newtonian rheological models were performed to assess whether the common assumption of Newtonian blood behavior offers similar results to a more realistic but computationally expensive non-Newtonian model. 16 coronary arteries (from 16 patients) were recon...
Article
Full-text available
Purpose This study aims to investigate the correlation between myocardial area at risk at coronary computed tomography angiography (CCTA) and the ischemic burden derived from myocardial computed tomography perfusion (CTP) by using the 17-segment model. Methods Forty-two patients with chest pain complaints who underwent a combined CCTA and CTP prot...
Article
Background Local hemodynamics are known to play an important role in the development of plaque erosion. Recent studies showed that erosion patients might be treated conservatively without stent implantation. We investigated evolution of hemodynamic parameters on the plaque erosion site in conservatively treated patients. Methods Computational flui...
Article
Background and aims Accurate classification of plaque composition is essential for treatment planning. Intravascular ultrasound (IVUS) has limited efficacy in assessing tissue types, while near-infrared spectroscopy (NIRS) provides complementary information to IVUS but lacks depth information. The aim of this study is to train and assess the effica...
Article
Objectives: This study aimed to investigate the impact of mechanical factors at baseline on the patency of a restorative conduit for coronary bypass grafts in an ovine model at serial follow-up up to 1 year. Methods: The analyses of 4 mechanical factors [i.e. bending angle, superficial wall strain and minimum and maximum endothelial shear stress...
Article
Full-text available
This study aimed to determine the ability of single fiber reflectance (SFR) spectroscopy incorporated in endoscopic ultrasound fine needle biopsy (EUS-FNB) procedures in the pancreas to distinguish benign and malignant pancreatic tissue in patient with pancreatic masses suspected for malignancy. Methods: This study was designed as a prospective obs...
Article
Cardiac allograft vasculopathy (CAV) remains a leading cause of long-term mortality after heart transplantation. Both preventive measures and treatment options are limited. This study aimed to evaluate the short-term effects of high-intensity interval training (HIT) on CAV in de novo heart transplant (HTx) recipients as assessed by optical coherenc...
Article
Full-text available
We aimed to evaluate the diagnostic agreement between radiofrequency (RF) intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for thin-cap fibroatheroma (TCFA) in non-infarct-related coronary arteries (non-IRA) in patients with ST-segment elevation myocardial infarction (STEMI). In the Integrated Biomarker Imaging Study (IBIS-4),...
Article
Background: Tissue necrosis, a consequence of inadequate tissue oxygenation, is a common post-operative complication. As current surgical assessments are often limited to visual and tactile feedback, additional techniques that can aid in the interrogation of tissue viability are needed to improve patient outcomes. In this bi-institutional pilot st...
Article
Full-text available
Background Volumetric intravascular ultrasound (IVUS) analysis is currently performed at a fixed frame interval, neglecting the cyclic changes in vessel dimensions occurring during the cardiac cycle that can affect the reproducibility of the results. Analysis of end-diastolic (ED) IVUS frames has been proposed to overcome this limitation. However,...
Article
Full-text available
We aimed to assess a possible difference of the neointimal coverage status and its quality after implantation of the current-generation metallic stents in patients with acute coronary syndrome (ACS) vs. stable coronary lesions (non-ACS). We comprehensively analyzed three prospective single-center observational studies RESTORE (UMIN000033009), HEAL-...
Article
Full-text available
Coronary luminal dimensions change during the cardiac cycle. However, contemporary volumetric intravascular ultrasound (IVUS) analysis is performed in non-gated images as existing methods to acquire gated or to retrospectively gate IVUS images have failed to dominate in research. We developed a novel deep learning (DL)-methodology for end-diastolic...
Article
Full-text available
Aims The aim of this study is to develop and validate a deep learning (DL) methodology capable of automated and accurate segmentation of intravascular ultrasound (IVUS) image sequences in real-time. Methods and results IVUS segmentation was performed by two experts who manually annotated the external elastic membrane (EEM) and lumen borders in the...
Article
Full-text available
Introduction: The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results: A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%); two or mo...
Article
Full-text available
Background:Intravascular polarization-sensitive optical frequency domain imaging (PS-OFDI) offers a novel approach to measure tissue birefringence, which is elevated in collagen and smooth muscle cells, that in turn plays a critical role in healing coronary thrombus (HCT). This study aimed to quantitatively assess polarization properties of coronar...
Article
Full-text available
Brain iron accumulation has been found to accelerate disease progression in amyloid-β(Aβ) positive Alzheimer patients, though the mechanism is still unknown. Microglia have been identified as key players in the disease pathogenesis, and are highly reactive cells responding to aberrations such as increased iron levels. Therefore, using histological...
Article
Introduction: Safety and efficacy of novel drug-eluting coronary stents (DES) are often preclinically tested using healthy swine coronary models. These only show fibrotic neointima (NI) response, while in humans we also observe uncovered struts and minimal NI thickening. Therefore, healthy swine models only allow limited conclusions. Hypothesis: In...
Article
Intravascular polarimetry (IVP) with polarization-sensitive (PS-) optical frequency domain imaging (OFDI) measures polarization properties of the coronary arterial wall in parallel with the conventional OFDI images (Figure 1A). Tissues rich in collagen and smooth muscle cells (SMCs) appear birefringent, while the presence of lipid and macrophages c...
Article
Full-text available
Background Despite the efficacy of novel drug eluting stents (DES) in preventing restenosis, this complication still occurs, as do neo-atherosclerosis development and poor stent strut coverage that are associated with stent thrombosis. Safety and efficacy of novel coronary stents are preclinically being tested using an established porcine coronary...
Article
Full-text available
Background and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES) remains elusive. The aim of this study was to determine whether the relationship between ESS and remodeling patterns differs in BRS from those seen in metalli...
Article
Aims To investigate local haemodynamics in the setting of acute coronary plaque rupture and erosion. Methods and results Intracoronary optical coherence tomography performed in 37 patients with acute coronary syndromes caused by plaque rupture (n = 19) or plaque erosion (n = 18) was used for three-dimensional reconstruction and computational fluid...
Article
Full-text available
Accumulation of iron within the cortex of Alzheimer’s disease (AD) patients has been reported by numerous MRI studies using iron-sensitive methods. Validation of iron-sensitive MRI is important for the interpretation of in vivo findings. In this study, the relation between the spatial iron distribution and T2∗-weighted MRI in the human brain was in...
Article
Full-text available
We aimed to quantitatively assess a possible difference of the neointimal quality between biodegradable polymer- (BP-) and durable polymer drug-eluting stents (DP-DESs). We conducted a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful OCT examination at planned 3-month follo...
Article
Full-text available
Heterogeneous neointimal response has been observed after implantation of all generations of coronary stents. Our aim was assessing local factors of shear stress (SS) and plaque characteristics in neointimal response after implantation of bioresorbable scaffolds (BRS) in bifurcations. Ten patients from the BIFSORB pilot study were analysed. Follow-...
Article
Full-text available
Purpose Fractal analysis can be used to quantitatively analyze the retinal microvasculature and might be a suitable method to quantify retinal capillary changes in sickle cell disease (SCD) patients. Retinal oximetry measurements might function as a proxy for the pathophysiology of cerebrovascular diseases. Moreover, hypoxia has an important role i...
Article
Background:Attenuation-compensated (AC) technique was recently introduced to improve the plaque characterization of optical coherence tomography (OCT). Histological validation demonstrated promising results but the efficacy and reproducibility of this technique for assessing in-vivo tissue composition remains unclear. Methods and Results:OCT images...
Article
Background and aim Scaffold design and plaque characteristics influence implantation outcomes and local flow dynamics in treated coronary segments. Our aim is to assess the impact of strut embedment/protrusion of bioresorbable scaffold on local shear stress distribution in different atherosclerotic plaque types. Method Fifteen Absorb everolimus-el...
Article
Background Local haemodynamic disturbances in coronary blood flow are associated with abnormal endothelial shear stress (ESS) and progressive atherosclerosis. However, standard techniques to estimate ESS lack the diagnostic specificity necessary for future clinical utility. Possible improvements include use of a more realistic non-Newtonian model o...
Article
Background Although blood is a non-Newtonian fluid, most clinical computational fluid dynamic (CFD) studies assume blood to be a Newtonian fluid with constant viscosity. At higher blood flow rates in larger arteries, the two models should present similar results, and the Newtonian assumption can be considered acceptable. However, whether the Newton...
Article
Background Polarization-sensitive (PS-) optical frequency domain imaging (OFDI) measures polarization properties of tissue together with conventional cross-sectional OFDI images of subsurface microstructure. PS-OFDI offers refined insight into plaque morphology and composition, which are implicated in the pathogenesis of acute coronary syndromes (A...
Article
Background Despite being a shear-thinning non-Newtonian fluid, most computational fluid dynamic (CFD) simulations assume blood to be a Newtonian fluid with constant viscosity. The use of more realistic assumptions may deepen mechanistic understanding of the relationship between blood flow disturbances and atherosclerosis, and improve the diagnostic...
Article
Full-text available
The aim of this manuscript is to provide guidelines for appropriate use of CFD to obtain reproducible and reliable wall shear stress maps in native and instrumented human coronary arteries. The outcome of CFD heavily depends on the quality of the input data, which include vessel geometrical data, proper boundary conditions, and material models. Ava...
Article
Full-text available
Objectives: The aims of this first-in-human pilot study of intravascular polarimetry were to investigate polarization properties of coronary plaques in patients and to examine the relationship of these features with established structural characteristics available to conventional optical frequency domain imaging (OFDI) and with clinical presentati...
Article
Full-text available
We aimed to evaluate feasibility, early healing and self-correcting properties of the Desolve 150 bioresorbable scaffold (BRS) implanted in bifurcation lesions, using the simple, provisional side branch (SB) stenting technique. BIFSORB pilot was a proof-of-concept study enrolling 10 patients with stable angina pectoris and a bifurcation lesion with...
Article
Aims: Scaffold design and plaque characteristics influence implantation outcomes and local flow dynamics in treated coronary segments. Our aim is to assess the impact of strut embedment/protrusion of bioresorbable scaffold on local shear stress distribution in different atherosclerotic plaque types. Methods and results: Fifteen Absorb everolimus...
Article
Full-text available
Malapposition is a common finding in stent and scaffold thrombosis (ScT). Evidence from studies with prospective follow-up, however, is scarce. We hypothesized that incidental observations of strut malapposition might be predictive of late ScT during subsequent follow-up. One hundred ninety-seven patients were enrolled in a multicentre registry wit...
Article
Objectives The purpose of this study was to derive a biomechanical stress metric that was based on the multifactorial assessment of coronary plaque morphology, likely related to the propensity of plaque rupture in patients. Background Plaque rupture, the most frequent cause of coronary thrombosis, occurs at locations of elevated tensile stress in...
Article
Full-text available
Objectives We aimed to evaluate the mechanical properties and healing patterns 6 and 9 months after implantation of the sirolimus-eluting Fantom bioresorbable scaffold (BRS). Background The Fantom BRS (Reva Medical, San Diego, USA) has differentiating properties including radiopacity, strut thickness of 125 µm, high expansion capacity and has demo...

Network

Cited By