Article
Full-text available
District heating and cooling systems can aid in decarbonisation and the provision of efficient heating and cooling in Europe. However, whereas these systems have achieved high penetration rates in colder climates of Northern, Central and Eastern Europe, they remain marginal in milder climates of Southern Europe. In terms of network design, district...
Article
Wind power only received occasional attention since the introduction of electricity until the 1970s, when a revived interest in alternative energy sources spurred the development thread that led to today’s wind turbines. Although attention and financial support at the time were directed toward government-funded MW-scale wind turbines, the small mod...
Article
Full-text available
We review the development of wind turbines for generating electricity from the late 19th century to the present, summarizing some key characteristics. We trace the move from two and four blade wind turbines to the three blades common today. We establish that it was not the governmental-funded wind programs with its large-scale prototypes of the 197...
Article
Full-text available
We review the development of wind turbines for generating electricity from the late 19th century to the present, summarizing some key characteristics. We trace the move from two to four blade wind turbines to the three blades common today. We establish that it was not the governmental-funded wind programs with its large-scale prototypes of the 1970...
Article
Full-text available
Energy is essential to human survival, and with increasing concerns regarding the global warming caused by greenhouse emissions, the energy field has become a global focal point [...]
Article
In this study, the sizing of primary side components for preparation of domestic hot water are analysed, both qualitatively and based on measurements of domestic hot water demand in one multi-family building with 268 apartments. The collected data spans a period of 18 days during the end of 2020 and is collected in 15-min, 1-min, and 6-s intervals....
Article
Full-text available
Based on data from 2083 wind turbines installed in Sweden from 1988 onwards, the accuracy of the predictions of the annual energy production (AEP) from the project planning phases has been compared to the actual wind-index-corrected production. Both the electricity production and the predicted AEP come from Vindstat, a database that collects inform...
Article
Full-text available
Based on data from 1162 wind turbines, with a rated power of at least 1.8 MW, installed in Sweden after 2005, the accuracy of the annual energy production (AEP) predictions from the project planning phases has been compared to the wind-index-corrected production. Both the production and the predicted AEP data come from the database Vindstat, which...
Article
Full-text available
This paper presents the wind energy potential and wind characteristics for 25 wind sites in Eritrea, based on wind data from the years 2000–2005. The studied sites are distributed all over Eritrea, but can roughly be divided into three regions: coastal region, western lowlands, and central highlands. The coastal region sites have the highest potent...
Article
A simple model for accounting for tower mass when estimating the first-mode eigenfrequency of a semi-guy-wired tower has been derived. This extends previous work where an analytical model of the semi-guy-wired tower of a 200-kW vertical-axis wind turbine was developed. The model was primarily used to estimate the eigenfrequencies as a result of add...
Article
Full-text available
Models of inflow-turbulence noise and turbulent-boundary-layer trailing-edge noise are compared to earlier measurements of a 200-kW vertical axis wind turbine so that conclusions regarding the origin of the aerodynamic noise can be drawn. The measurement campaigns, which aimed at establishing the noise emission value and locating the aerodynamic no...
Article
Full-text available
This paper summarizes wind turbines of Swedish origin, 50 kW and above. Both the large governmental-funded prototypes from the early 1980s and following attempts to build commercial turbines are covered. After the 1973 oil crisis, a development program for wind turbine technology was initiated in Sweden, culminating in the early 1980s with the 2 an...
Article
Full-text available
This paper summarizes and introduces all vertical axis wind turbine (VAWT) projects where 100 kW or larger turbines have been installed. The basis for the review is both existing literature and personal correspondence with people once involved in the different developments. By citing the most relevant work for each project, the paper will also work...
Article
Noise levels emitted from a 200 kW H-rotor vertical-axis wind turbine have been measured using a microphone array at four different positions, each at a hub-height distance from the tower. The microphone array, comprising 48 microphones in a spiral pattern, allows for directional mapping of the noise sources in the range of 500 Hz to 4 kHz. The pro...
Thesis
Full-text available
Vertical-axis wind turbines (VAWTs) have with time been outrivaled by the today more common and economically feasible horizontal-axis wind turbines (HAWTs). However, VAWTs have several advantages which still make them interesting, for example, the VAWTs can have the drive train at ground level and it has been argued that they have lower noise emiss...
Article
Full-text available
The influence of turbulence intensity (TI) on the tip speed ratio for maximum power coefficient, here called λCp_max, is studied for a 200 kW VAWT H-rotor using logged data from a 14 month period with the H-rotor operating in wind speeds up to 9 m/s. The TI - λCp_max relation is examined by dividing 10 min mean values in different turbulence intens...
Article
The relation between power performance and turbulence intensity for a VAWT H-rotor is studied using logged data from a 14 month (discontinuous) period with the H-rotor operating in wind speeds up to 9 m/s. The turbine, designed originally for a nominal power of 200 kW, operated during this period mostly in a restricted mode due to mechanical concer...
Article
Full-text available
The noise emission from a vertical axis wind turbine (VAWT) has been investigated. A noise measurement campaign on a 200 kW straight-bladed VAWT has been conducted, and the result has been compared to a semi-empirical model for turbulent-boundary-layer trailing edge (TBL-TE) noise. The noise emission from the wind turbine was measured, at wind spee...
Conference Paper
Initial noise measurements were performed on a 200kW vertical axis wind turbine (VAWT) and results were compared to that of a Vestas V27, a similar size horizontal axis wind turbine (HAWT). Multiple recording units were placed in line downwind of the turbine to investigate noise propagation. The frequency distribution of the noise were analyzed ind...
Article
Eigen frequencies of a vertical axis wind turbine tower made out of laminated wood which are both bolted to the ground and supported by guy wires are studied and compared. Using beam theory, an analytical model taking the guy wires into account for calculating the first mode eigen frequency of the tower has been derived. The analytical model is the...
Conference Paper
Resonance analysis for a vertical axis wind turbine is performed. The turbine may be described as semi-guy wired, being bolted stiffly to the ground as well as supported by guy wires. The influence of the first mode eigen frequency of the guy wires and how it is affected by wind load is examined. Using beam theory, an analytical model for calculati...

Network

Cited By