Baskaran Ayyalusamy

Baskaran Ayyalusamy
P. A. College of Engineering and Technology | PACET · Pollachi

B.E, M.E, Ph.D

About

12
Publications
51,938
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
166
Citations
Additional affiliations
July 2008 - present
PA College of Engineering and Technology, Coimbatore, India
Position
  • Professor (Associate)
June 2008 - present
P. A. College of Engineering and Technology
Position
  • Professor (Associate)

Publications

Publications (12)
Article
In this study, the first and second law analysis of Dimethyl ether (DME) and its blend refrigerants (R429A, R435A, R 510A) is presented as an alternatives to R134a. A computational model, developed in cycle_D software, is employed for comparing the performance of these refrigerants in vapour compression refrigeration cycle. The thermodynamic proper...
Article
Full-text available
This paper presents the theoretical investigation of effects of sub-cooling on the performance of eco-friendly alternative refrigerants (R152a, RE170 (Dimethyl ether) in a domestic refrigeration system. The study was performed using a vapour compression system with the aim of 􀃶nding a drop-in replacement for R134a. An increase in sub-cooling effect...
Article
Full-text available
¬This study deals with the Thermodynamic evaluation of the use of Di-methyl ether refrigerants in household refrigeration systems which utilize R134a as a working fluid. A theoretical computational analysis was developed for R134a, Di-methyl ether (RE170) and the selected mixtures (R429A, R435A and R510A) in the standard refrigeration cycle ASHRAE,...
Article
Full-text available
This communication deals with the exergetic analysis of a vapour compression refrigeration system with selected refrigerants. The various parameters computed are COP, exergetic efficiency and EDR in the system. Effects of condenser temperature, evaporator temperature and sub-cooling of condenser outlet, super-heating of evaporator outlet and effect...
Article
Full-text available
In this paper the performance of a vapour compression refrigeration system with ZrO2 nanoparticles in the working fluid was studied. Nano refrigerant was synthesized on the basis of the concept of the nanofluids, which was prepared by mixing ZrO2 nanoparticles with R152a refrigerant. The conventional refrigerant R134a has a global warming potential...
Article
Full-text available
In the present study, the possibility of using refrigerant blend of RE170 and R600a as alternative to the refrigerant R134a in domestic refrigerator working on Vapour Compression System has been assessed theoretically. R134a is currently used as the refrigerant in refrigerator replacing the ozone depleting refrigerant R12. Although R134a has no ozo...
Article
Full-text available
R-134a is currently used as the refrigerant in refrigerator replacing the ozone depleting refrigerant R-12. Although R-134a has no Ozone Depletion Potential (ODP), it has a relatively larger Global Warming Potential (GWP) of 1300. In an effort to reduce greenhouse gas emissions, R-152a (difluoroethane) (GWP 130) and Hydrocarbons (GWP 20) are being...
Article
Full-text available
The parametric investigations of actual Vapour Compression Refrigeration (VCR) cycle in terms of Coefficient of Performance (COP), Exergy Destruction (ED) and exergetic efficiency of refrigerants R134a, R152a and RE170 have been predicted with the help of vapour compression cycle design software (CYCLE_D4.0). The present investigation has been carr...
Article
Full-text available
In the present study, the possibility of using refrigerant blends of RE 170, R152a and R600a as alternative to the refrigerants R12 and R134a in domestic refrigerators working on Vapour Compression System has been assessed theoretically. R134a is currently used as the refrigerant in refrigerator replacing the ozone depleting refrigerant R12. Althou...
Article
Full-text available
This paper presents the analysis results of R429A, R430A, R431A and R435A as drop in substitute for R152a at various evaporating temperature with condenser temperature 30°C, 40°C and 50°C. A theoretical study of thermodynamic properties such as pressure, density, and specific volume, latent heat of vaporization compression index, and critical value...
Article
Full-text available
A performance analysis on a vapour compression refrigeration system with various eco-friendly refrigerants of HFC152a, HFC32, HC290, HC1270, HC600a and RE170 were done and their results were compared with R134a as possible alternative replacement. The results showed that the alternative refrigerants investigated in the analysis RE170, R152a and R60...

Network

Cited By