Bart L Kaptein

Bart L Kaptein
  • PhD. MSc
  • Medical Imaging in Orthopaedics at Leiden University Medical Centre

About

145
Publications
19,570
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
2,994
Citations
Introduction
Bart L Kaptein currently works at the Department of Orthopedic Surgery, Leiden University Medical Centre.
Current institution
Leiden University Medical Centre
Current position
  • Medical Imaging in Orthopaedics
Additional affiliations
January 1988 - January 1993
Delft University of Technology
Position
  • PhD Student
January 2001 - present
Leiden University Medical Centre
Position
  • Medical Imaging in Orthopaedics

Publications

Publications (145)
Article
Full-text available
Background and purpose Standardized reporting on methodology and results in clinical RSA research papers facilitates evaluation of quality and interpretation of results. We aimed to assess the extent to which radiostereometric analysis (RSA) and computed tomography-based RSA (CT-RSA) studies adhered to the items of the new RSA reporting guideline f...
Article
Full-text available
To our unpleasant surprise, we discovered that we have mistakenly included incorrect values in Table 2 (Reported accuracy of CT-RSA) for the paper by De Laat et al. (2024). The paper by De Laat (2024) is from our group as well. In the draft version of the systematic review manuscript, we included data from a draft manuscript of the paper by De Laat...
Article
Full-text available
Background and purpose: Computed tomography-based radiostereometric analysis (CT-RSA) is an alternative to conventional radiostereometric analysis (RSA) in measuring implant migration, circumventing the need for operative insertion of tantalum markers. The accuracy and precision of different CT-RSA techniques in various joints are still unclear, an...
Article
Full-text available
Background and purpose Early migration of the uncemented cruciate-sacrificing rotating platform ATTUNE and Low Contact Stress (LCS) tibial components was classified as at-risk for aseptic loosening rates exceeding 6.5% at 15 years based on recent fixation-specific migration thresholds. In this secondary report of a randomized controlled trial (RCT)...
Article
Aseptic loosening remains one of the top causes of revision surgery of total knee arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure implant migration, however limitations prevent its clinical use. New methods have allowed the same measurements as RSA to be performed with computed tomography (CT) scanners (CT‐RSA)....
Article
Full-text available
Radiostereometric analysis (RSA) is the current gold standard to determine implant migration, but it requires bone markers and special equipment. Therefore, we developed VoluMetric Matching Micromotion Analysis (V3MA), a software program for Computed Tomography‐based radiostereometric analysis (CT‐RSA). This study aimed to determine the accuracy an...
Article
Though radiostereometric analysis (RSA) is the gold standard for migration tracking, computed tomography‐based RSA (CT‐RSA) does not require marker beads and is available for clinical adoption. This study investigated CT‐RSA in comparison to RSA for assessing hip implant stability with inducible displacement (ID) examinations. Patients ( n = 48) fr...
Article
Full-text available
Background and purpose: The low-dose EOS Imaging System is an emerging tool for 3-dimensional measurements in orthopedics. The clinical feasibility for measuring total hip arthroplasty (THA) liner wear has not yet been investigated. We aimed to evaluate the feasibility of using EOS to measure THA liner wear by examining the experimental accuracy us...
Article
Introduction: The inelasticity of ceramic bearings might affect primary stability and migration of implants in press-fit total hip arthroplasty (THA). This randomised controlled trial compares migration patterns of the uncemented Delta-TT cup and H-MAX S stem between ceramic and polyethylene liners, up to 5 years follow-up. Methods: Patients rec...
Article
Aims: The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims includ...
Article
Background Radiostereometric analysis (RSA) provides highly accurate data about the migration of a total knee arthroplasty (TKA) component. However, patient-reported outcome measures (PROMs) reflect the patients’ perspective of their functional status, pain, and overall health after TKA. The aim of this study was to evaluate the association between...
Article
Full-text available
Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and c...
Article
Aims The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling....
Article
Full-text available
Aims Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research...
Article
Full-text available
Background and purpose: Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all...
Article
Purpose This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed‐bearing, posterior‐stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert. Me...
Article
Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods: Overall, 87 patients undergoin...
Article
Full-text available
Background Loosening is a major cause for failure of total hip and total knee arthroplasties (THAs/TKAs). Preemptive diagnostics of asymptomatic loosening could open strategies to prevent gross loosening. A multitude of biomarkers may discriminate between loosened and stable implants, but it is unknown which have the best performance. The present s...
Article
Aims Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported...
Article
The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures. A total of 50 patients...
Article
Full-text available
Background: Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their ceme...
Article
The best treatment method of large acetabular bone defects at revision THR remains controversial. Some of the factors that need consideration are the amount of residual pelvic bone removed during revision; the contact area between the residual pelvic bone and the new implant; and the influence of the new acetabular construct on the centre of rotati...
Article
Aims The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and pa...
Article
Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners...
Article
Full-text available
Introduction Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). Materials and methods A cohort of 44 patients (mean age 7...
Article
Aims: The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A...
Article
Radiostereometric analysis can be used for computing movement of a tibial baseplate relative to the tibia (termed migration) to detect baseplate instability. Quantifying migration in six degrees of freedom requires establishing a coordinate system in which to express the movement. Establishing consistent migration directions among patients and base...
Article
Full-text available
Aims: The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods: A total of 40 patients with end-stage osteoarthritis were includ...
Article
Full-text available
Purpose Dynamic radiostereometric analysis (dRSA) enables precise non-invasive three-dimensional motion-tracking of bones for assessment of joint kinematics. Hereby, the biomechanical effects of arthroscopic osteochondroplasty of the hip (ACH) can be evaluated in patients with femoroacetabular impingement (FAI). The aim was to investigate the pre-...
Article
Full-text available
Background Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. Methods RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arco...
Article
Full-text available
Background and purpose: Ceramic liners may reduce early stability of uncemented acetabular components due to higher stiffness. However, the bone ingrowth capacities of porous trabecular titanium might compensate for this effect. This prospective randomized trial quantifies migration patterns of the Delta-TT cup, and compares polyethylene and ceram...
Article
Full-text available
Background and purpose: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). Patients and methods: 6 patients with Anatomical Dual Mobility acetabular components were included....
Article
Full-text available
Background and purpose: In total knee arthroplasty (TKA), metal-backed (MBT) and all-polyethylene (APT) designs have shown comparable implant migration up to 2 years postoperatively using radiostereometric analysis (RSA). However, studies comparing mid-term migration of both designs are lacking. Furthermore, continuously migrating TKAs up to 2 yea...
Article
Full-text available
Background and purpose – The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods – In this prospective, multi-arm study, 10...
Article
Background Mixed results for functional outcomes and long-term fixation have been reported for first metatarsophalangeal arthroplasty. This prospective study was designed to evaluate the migration of the BioPro metatarsophalangeal-1 (MTP-1) joint hemiprosthesis with Roentgen stereophotogrammetric analysis (RSA). Migration patterns of the prosthesis...
Article
Full-text available
Background Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. Methods The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four gr...
Article
Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient a...
Article
Background: Orthopaedic surgeons aim for mechanical alignment when performing total knee arthroplasty (TKA) as malalignment is associated with loosening. Loosening may be predicted by migration as measured with radiostereometric analysis (RSA), but previous RSA studies on postoperative alignment have shown contradictory results and have been limit...
Article
Aims: The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). Methods: A randomized controlled radiostereometric analysis (RSA) trial was conducted includi...
Article
Full-text available
BACKGROUND Pediatric occipitothoracic fusion can be challenging because of small size pedicles and thin occipital bone. Three-dimensional (3D) printing technology can help with accurate screw insertion but has not been described for occipital keel plate positioning so far. OBJECTIVE To describe the novel use of 3D technology to position occipital...
Article
Full-text available
Introduction: Excellent long-term survival has been reported for both the Taperloc and the Mallory-Head cementless stems. However, little is known about the migration behaviour of these stems which have different design rationales. The purpose of this randomised clinical trial was to compare the migration and clinical outcomes of these stems durin...
Article
Background Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR). The aim of this study was to determine if cementless UKR fixation is as good as cemented by comparing the five-year migration measured radiostereometric analysis (RSA) in a randomised controlled trial. Methods Thirty-nine patients were randomised...
Article
Full-text available
Background and purpose — Modular-neck hip stems have been identified with corrosion-related problems from the neck–stem junction. We report an ongoing varus deformity of modular-neck hip stems with simultaneous metal ion release observed during a study comparing the migration of modular vs. standard hip stems. Patients and methods — We followed 50...
Article
Full-text available
Background and purpose — Little is known about the long-term migration pattern of cementless stems in total hip arthroplasty (THA). Furthermore, the role of bioactive coatings in fixation, and thus migration, remains uncertain. Hydroxyapatite (HA) is the most commonly used bioactive coating. However, delamination of the coating might induce looseni...
Article
Objectives: This study evaluated whether patients with a left-sided femoral neck fracture (FNF) treated with a sliding hip screw (SHS) had a higher implant failure rate than patients treated for a right-sided FNF. This was performed to determine the clinical relevance of the clockwise rotational torque of the femoral neck lag screw in a SHS, in re...
Article
Full-text available
Aims The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Mea...
Article
Aims: Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. Thi...
Article
Background: The number of revisions after TKA is expected to rise because of aging populations in many countries and because patients are undergoing TKA at younger ages. Aseptic loosening is a major reason for late revision, which can be predicted by radiostereometric analysis (RSA) of small groups of patients at 2 years of follow-up. RSA is there...
Article
Full-text available
Background and purpose — The uncemented Symax hip stem has shown early proximal ingrowth as result of the BONIT-hydroxyapatite (HA) coating and the distal DOTIZE surface treatment. We evaluated 2-year postoperative radiostereometric analysis (RSA) migration of the Symax hip stem in THA patients. We also investigated the correlation between migratio...
Article
Introduction: Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. Methods: A femoral stem with 3 bead-towers w...
Article
Full-text available
Background and purpose — The all-polyethylene tibial (APT) component, introduced in the early 1970s, was surpassed by metal-backed tibial (MBT) trays as the first choice for total knee arthroplasty (TKA). With improved polyethylene, the modern APT components can reduce costs, and have shown equivalent results in survivorship and early migration of...
Article
Full-text available
Background Compliance rates with patient-reported outcome measures (PROMs) collected alongside arthroplasty registries vary in the literature. We described the feasibility of a routinely collected set PROMs alongside the Dutch Arthroplasty Register. Methods The longitudinal Leiden Orthopaedics Outcomes of OsteoArthritis Study is a multicenter (7 h...
Article
Full-text available
Background and purpose — Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method...
Article
Full-text available
Background and purpose — Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplast...
Article
Full-text available
Background An anterior cruciate ligament (ACL) rupture often occurs during rotational trauma to the knee and may be associated with damage to extracapsular knee rotation–stabilizing structures such as the anterolateral ligament (ALL). Purpose To investigate ex vivo knee laxity in 6 degrees of freedom with and without ALL reconstruction as a supple...
Article
Full-text available
Objectives To validate the precision of digitally reconstructed radiograph (DRR) radiostereometric analysis (RSA) and the model-based method (MBM) RSA with respect to benchmark marker-based (MM) RSA for evaluation of kinematics in the native hip joint. Methods Seven human cadaveric hemipelves were CT scanned and bone models were segmented. Tantalu...
Article
Full-text available
Frailty is highly prevalent in the elderly, increasing the risk of poor health outcomes. The Groningen Frailty Indicator (GFI) is a 15-item validated questionnaire for the elderly. Its value in patients with end-stage hip or knee osteoarthritis (OA) has not yet been determined. This study assesses the validity of the GFI in this patient group. End-...
Article
Full-text available
Background Dynamic RSA (dRSA) enables non-invasive 3D motion-tracking of bones and may be used to evaluate in-vivo hip joint kinematics including hip pathomechanics such as femoroacetabular impingement (FAI) and the biomechanical effects of arthroscopic cheilectomy and -rim trimming (ACH). The study aim was to evaluate the kinematic changes in the...
Article
Objectives: Static radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin mar...
Article
PurposeLittle is known about the anterolateral ligament’s (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. Methods Eight human donor...
Article
Full-text available
Background and purpose — Implant inducible micromotions have been suggested to reflect the quality of the fixation interface. We investigated the usability of dynamic RSA for evaluation of inducible micromotions of the Oxford Unicompartmental Knee Arthroplasty (UKA) tibial component, and evaluated factors that have been suggested to compromise the...
Article
Aims The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogra...
Article
Aims: The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotog...
Article
Full-text available
Objectives: An important measure for the diagnosis and monitoring of knee osteoarthritis is the minimum joint space width (mJSW). This requires accurate alignment of the x-ray beam with the tibial plateau, which may not be accomplished in practice. We investigate the feasibility of a new mJSW measurement method from stereo radiographs using 3D sta...
Article
Full-text available
While the anterior cruciate ligament (ACL) is considered one of the most important ligaments for providing knee joint stability, its influence on rotational laxity is not fully understood and its role in resisting rotation at different flexion angles in vivo remains unknown. In this prospective study, we investigated the relationship between in viv...
Article
Full-text available
Background and purpose Stability and survival of cemented total hip prostheses is dependent on a multitude of factors, including the type of cement that is used. Bone cements vary in viscosity, from low to medium and high. There have been few clinical RSA studies comparing the performance of low- and high-viscosity bone cements. We compared the mig...
Article
Full-text available
Background Self-reported knee instability has been reported in 60–80% of all patients suffering from mild to moderate knee osteoarthritis (OA) [1], but the prevalence of self-reported knee joint instability in patients with end-stage OA is unknown. So far, a clear cause for this sense of instability has not been elucidated. Two opposing hypotheses...
Article
Purpose A concern that arises with any new prosthesis is whether it will achieve satisfactory long-term implant stability. The gold standard of assessing the quality of fixation in a new or relatively new implant is to undertake a randomized controlled trial using radiostereometric analysis. It was hypothesized that both mobile-bearing total knee a...
Article
Full-text available
Purpose: Clinicians do not currently have a simple means of identifying patients at risk for developing incident and persisting knee symptoms in osteoarthritis (OA). We examined whether a clinically detected knee effusion predicts this. Methods: Data were extracted from the Osteoarthritis Initiative. All participants (n ¼ 4646) and the subgroup wit...
Article
Background: Implant migration can be accurately quantified by model-based Roentgen Stereophotogrammetric Analysis (RSA), using an implant surface model to locate the implant relative to the bone. In a clinical situation, a single reverse engineering (RE) model for each implant type and size is used. Questions/purpose It is unclear to what extent t...
Article
Full-text available
The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamm...
Article
The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs. A total of 43 patients were randomised to receive either a cemented or a cementles...
Article
Full-text available
Introduction: Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conv...
Article
Measuring the minimum-joint-space-width (mJSW) in total knee arthroplasty (TKA) in Roentgen stereophotogrammetric analysis (RSA) provides valuable information on polyethylene wear, a leading cause for TKA failure. Most existing studies use non-weight-bearing (NWB) patient positioning. The latter may compromise mJSW measurements due to knee laxity w...
Article
Full-text available
Knee contact mechanics play an important role in knee implant failure and wear mechanics. Femoral condylar contact loss in total knee arthroplasty has been reported in some studies and it is considered to potentially induce excessive wear of the polyethylene insert.Measuring in vivo forces applied to the tibial plateau with an instrumented prosthes...
Article
High-flexion total knee arthroplasty was introduced to meet the demands of daily activity requiring increased knee flexion. However, concerns have been raised regarding the fixation of high-flexion total knee arthroplasty components and increased rates of loosening have been reported. To date, migration, and thus fixation, of high-flexion total kne...
Article
Full-text available
Background Model-based Roentgen Stereophotogrammetric Analysis (MBRSA) allows the accurate in vivo measurement of the relative motion between an implant and the surrounding bone (migration), using pose-estimation algorithms and three dimensional geometric surface models of the implant. The goal of this study was thus to investigate the effect of su...
Article
Implant failure related to polyethylene wear remains an important issue in total knee arthroplasty. Polyethylene wear is usually assessed in vivo by measuring the remaining insert thickness on X-ray images of the knee. To reflect the amount of wear debris more accurately, a 3-dimensional overlap measurement has been suggested, which is based on imp...
Article
Full-text available
We present a prospective, two-centre radiostereometric analysis (RSA) regarding the stability of a flattened pole titanium press-fit cup (EP-FIT PLUS), and whether additional hydroxyapatite coating leads to faster bone ingrowth into the porous coating. Forty-two postmenopausal female patients (44 hips) undergoing total hip arthroplasty for primary...
Article
This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB o...
Article
Full-text available
The purpose of this in vitro study was to investigate the influence of aneurysm wall stiffness and of the presence of intraluminal thrombus (ILT) on aneurysm wall movement. Three latex aneurysms were used with different wall stiffness. The aneurysms, equipped with 20 tantalum markers, were attached to an in vitro circulation model. Fluoroscopic roe...
Article
Excessive early migration of femoral stems following total hip arthroplasty and tibial components following total knee arthroplasty is associated with their long-term survival and allows reliable early evaluation of implant performance. However, a similar relationship involving acetabular components following hip arthroplasty has not been evaluated...
Article
Studying joint kinematics is of interest to improve prosthesis design and to characterize postoperative motion. State of the art techniques register bones segmented from prior computed tomography or magnetic resonance scans with X-ray fluoroscopic sequences. Elimination of the prior 3D acquisition could potentially lower costs and radiation dose. T...

Network

Cited By