Andrew Webb

Andrew Webb
Leiden University Medical Centre | LUMC · Department of Radiology

PhD

About

613
Publications
86,619
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
22,789
Citations
Introduction

Publications

Publications (613)
Article
Full-text available
Purpose To evaluate accelerated T1‐ and T2‐mapping techniques for ultra–low‐field MRI using low‐rank reconstruction methods. Methods Two low‐rank–based algorithms, image‐based locally low‐rank (LLR) and k‐space–based structured low‐rank (SLR), were implemented to accelerate T1 and T2 mapping on a 46 mT Halbach MRI scanner. Data were acquired with...
Preprint
Full-text available
Nuclear magnetic resonance instruments are becoming available to the do-it-yourself community. The challenges encountered in the endeavor to build a magnetic resonance imaging instrument from scratch were confronted in a four-day hackathon at Singapore University of Technology and Design in spring 2024. One day was devoted to educational lectures a...
Article
Full-text available
Objective To investigate the trade-off between magnet bore diameter and the distance between the conductive Faraday shield and RF head coil for low-field point-of-care neuroimaging systems. Methods Electromagnetic simulations were performed for three different Faraday shield geometries and two commonly used RF coil designs (spiral and solenoid) to...
Article
Full-text available
Purpose Ultra‐high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B 1+$$ {}_1^{+} $$ field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface t...
Article
This study aims to assess the statistical significance of training parameters in 240 dense UNets (DUNets) used for enhancing low Signal-to-Noise Ratio (SNR) and undersampled MRI in various acquisition protocols. The objective is to determine the validity of differences between different DUNet configurations and their impact on image quality metrics...
Preprint
Full-text available
Objective: This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Methods: Each coil element was created by shaping a twisted pair of wires into a circle. One wire was interrupted at the top, wh...
Article
The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have “MR Conditional” (i.e., an item with demonstrated safet...
Article
Full-text available
Purpose Concomitant gradient fields have been extensively studied at clinical field strengths. However, their effects have not yet been modeled for low‐field point‐of‐care (POC) systems. The purpose of this work is to characterize the effects associated with concomitant fields for POC Halbach‐array‐based systems. Methods The concomitant fields ass...
Article
Full-text available
Direct spectroscopic quantification of small molecules using low cost, low field (< 0.1 T) large bore portable magnets is not possible using conventional techniques due the presence of strong homonuclear coupling which results in complicated spectral patterns with resonances separated by much less than the achievable spectral linewidth. In contrast...
Preprint
Full-text available
Background Radial k-space sampling is compared with conventional Cartesian k-space sampling in small field-of -view respiratory-triggered Turbo Spin Echo (TSE) T2-weighted imagingof the pancreas regarding image quality and artifacts in a screening program for hereditary pancreatic cancer. Methods Small field-of-view radial and Cartesian k-space sam...
Article
The use of 7 Tesla (T) magnetic resonance imaging (MRI) is expanding across medical specialties, particularly, clinical neurosciences and orthopedics. Investigational 7 T MRI has also been performed in cardiology. A limiting factor for expansion of the role of 7 T, irrespective of the body part being imaged, is the sparse testing of biomedical impl...
Article
Full-text available
In March 2022, the first ISMRM Workshop on Low‐Field MRI was held virtually. The goals of this workshop were to discuss recent low field MRI technology including hardware and software developments, novel methodology, new contrast mechanisms, as well as the clinical translation and dissemination of these systems. The virtual Workshop was attended by...
Preprint
Full-text available
Direct spectroscopic quantification of small molecules using low cost, low field (< 0.1 Tesla) large bore portable magnets is not possible using conventional techniques due the presence of strong homonuclear coupling which results in complicated spectral patterns with resonances separated by much less than the achievable spectral linewidth. In cont...
Article
Full-text available
We have investigated an approach for obtaining ¹ H NMR spectra of different alcohols on a large-bore (27 cm diameter), B 0 = 0.05 T ( f 0 = 2 MHz) portable MRI scanner. We used a Carr–Purcell–Meiboom–Gill (CPMG) sequence to acquire multiecho data from solutions of different alcohols, focusing on ethanol, a molecule of relevance to many applications...
Article
Full-text available
Objective: Low-cost low-field point-of-care MRI systems are used in many different applications. System design has correspondingly different requirements in terms of imaging field-of-view, spatial resolution and magnetic field strength. In this work an iterative framework has been created to design a cylindrical Halbach-based magnet along with int...
Article
Full-text available
Objective To implement magnetic resonance fingerprinting (MRF) on a permanent magnet 50 mT low-field system deployable as a future point-of-care (POC) unit and explore the quality of the parameter maps.Materials and methods3D MRF was implemented on a custom-built Halbach array using a slab-selective spoiled steady-state free precession sequence wit...
Article
Full-text available
Objective To review the major hardware components of low-field point-of-care MRI systems which affect the overall sensitivity. Methods Designs for the following components are reviewed and analyzed: magnet, RF coils, transmit/receive switches, preamplifiers, data acquisition system, and methods for grounding and mitigating electromagnetic interfer...
Article
Full-text available
Purpose Activated brown adipose tissue (BAT) enhances lipid catabolism and improves cardiometabolic health. Quantitative MRI of the fat fraction (FF) of supraclavicular BAT (scBAT) is a promising noninvasive measure to assess BAT activity but suffers from high scan variability. We aimed to test the effects of coregistration and mutual thresholding...
Article
Full-text available
Objective We outline our vision for a 14 Tesla MR system. This comprises a novel whole-body magnet design utilizing high temperature superconductor; a console and associated electronic equipment; an optimized radiofrequency coil setup for proton measurement in the brain, which also has a local shim capability; and a high-performance gradient set....
Article
Full-text available
Objective: To simulate the magnetic and electric fields produced by RF coil geometries commonly used at low field. Based on these simulations, the specific absorption rate (SAR) efficiency can be derived to ensure safe operation even when using short RF pulses and high duty cycles. Methods: Electromagnetic simulations were performed at four diff...
Article
Purpose: to describe the construction and testing of a portable point-of-care low-field MRI system on site in Africa. Methods: all of the components to assemble a 50 mT Halbach magnet based system, together with the necessary tools, were air-freighted from The Netherlands to Uganda. The construction steps included individual magnet sorting, fill...
Article
Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpens...
Article
Full-text available
Does the Halbach magnetization rotation rule that is used for designing circular magnet arrays for achieving the best homogeneity hold also for an elliptical or other non-circular cross-section? In this article, it is shown that a new numerically optimized magnetization rotation rule can provide more than three orders of magnitude improvement in fi...
Article
Parallel transmission (pTX) techniques are required to tackle a number of challenges, e.g., the inhomogeneous distribution of the transmit field and elevated specific absorption rate (SAR), in ultra-high field (UHF) MR imaging. Additionally, they offer multiple degrees of freedom to create temporally- and spatially-tailored transverse magnetization...
Article
Full-text available
Purpose High permittivity dielectric pads are known to be effective for tailoring the RF field and improving image quality in high field MRI. Despite a number of studies reporting benign specific absorption rate (SAR) effects, their “universal” safety remains an open concern. In this work, we evaluate the impact of the insulation material in betwee...
Article
One of the main challenges for point-of-care (POC) MRI systems is electromagnetic interference (EMI), since such systems are intended for use outside conventional Faraday-shielded rooms. Many methods have been proposed based on EMI detection via sensors external to the MRI system, followed by different types of signal processing to reduce artifacts...
Article
Full-text available
MR scans of low-gamma X-nuclei, low-concentration metabolites, or standard imaging at very low field entail a challenging tradeoff between resolution, signal-to-noise, and acquisition duration. Deep learning (DL) techniques, such as UNets, can potentially be used to improve such “low-quality” (LQ) images. We investigate three UNets for upscaling LQ...
Article
Full-text available
Infrared thermography (IRT) is widely used to assess skin temperature in response to physiological changes. Yet, it remains challenging to standardize skin temperature measurements over repeated datasets. We developed an open-access semi-automated segmentation tool (the IRT-toolbox) for measuring skin temperatures in the thoracic area to estimate s...
Article
Full-text available
MRI technology has profoundly transformed current healthcare systems globally, owing to advances in hardware and software research innovations. Despite these advances, MRI remains largely inaccessible to clinicians, patients, and researchers in low resource areas, such as Africa. The rapidly growing burden of non-communicable diseases in Africa und...
Article
Full-text available
Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360mT in different settings, all of whi...
Article
The use of 7 Tesla (T) magnetic resonance imaging (MRI) is expanding across neurosurgical and neurologic specialties. However, few neurosurgical-related implants have been tested for safety at 7 T, limiting its use in patients with cranial fixation, shunt placements, and other implants. Implant safety can be determined via the American Society for...
Preprint
Full-text available
Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpens...
Article
Full-text available
Microvascular function is an important component in the physiology of muscle. One of the major parameters, blood perfusion, can be measured non‐invasively and quantitatively by arterial spin labeling (ASL) MRI. Most studies using ASL in muscle have only reported data from a single slice, thereby assuming that muscle perfusion is homogeneous within...
Article
Full-text available
In a standard spin echo, the time evolution due to homonuclear couplings is not reversed, leading to echo‐time (TE) dependent modulation of the signal amplitude and signal loss in the case of overlapping multiplet resonances. This has an adverse effect on quantification of several important metabolites such as glutamate and glutamine. Here, we prop...
Article
Full-text available
Purpose Brown adipose tissue (BAT) increases metabolic heat production in response to cold exposure. Body size and composition are involved in the human cold response, yet the influence of BAT herein have not fully been explored. Here, we aimed to study the association of the cold-induced shivering threshold time with body composition, BAT, the per...
Poster
Full-text available
Synopsis We examined access to MRI in Sub-Saharan Africa to provide a novel framework to address MRI needs. A 68-question needs assessment survey was distributed to collaborators, radiologists and radiographers in Africa, yielding 158 unique responses. Survey responses were analyzed to provide insight into challenges and opportunities for MRI acces...
Preprint
Full-text available
MRI technology has profoundly transformed current healthcare and research systems globally. The rapidly growing burden of non-communicable diseases in Africa has underscored the importance of improving access to MRI equipment as well as training and research opportunities on the continent. The Consortium for Advancement of MRI Education & Research...
Article
Full-text available
Low-field MRI scanners are significantly less expensive than their high-field counterparts, which gives them the potential to make MRI technology more accessible all around the world. In general, images acquired using low-field MRI scanners tend to be of a relatively low resolution, as signal-to-noise ratios are lower. The aim of this work is to im...
Article
Comments about the above article [1] were proposed. We thank and reply to the authors of the comments about our model of high-permittivity dielectric ring resonators used as microscopy magnetic resonance probes. In this prospect, we reply part by part to the comments.
Article
Full-text available
This article reviews recent developments in designing and testing new types of materials which can be: (i) placed around the body for in vivo imaging, (ii) be integrated into a conventional RF coil, or (iii) form the resonator itself. These materials can improve the quality of MRI scans for both in vivo and magnetic resonance microscopy application...
Article
Full-text available
Purpose Parallel RF transmission (PTx) is one of the key technologies enabling high quality imaging at ultra‐high fields (≥7T). Compliance with regulatory limits on the local specific absorption rate (SAR) typically involves over‐conservative safety margins to account for intersubject variability, which negatively affect the utilization of ultra‐hi...
Preprint
Full-text available
Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which...
Article
Full-text available
Background Accuracy and precision assessment in radiomic features is important for the determination of their potential to characterize cancer lesions. In this regard, simulation of different imaging conditions using specialized phantoms is increasingly being investigated. In this study, the design and evaluation of a modular multimodality imaging...
Article
Full-text available
In Becker muscular dystrophy (BMD), muscle weakness progresses relatively slowly, with a highly variable rate between patients. This complicates clinical trials, as clinically relevant changes are difficult to capture within the typical duration of a trial. Therefore, predictors for disease progression are needed. We assessed if temporal increase o...
Article
Full-text available
Objective Neonatal brain and cardiac imaging would benefit from the increased signal-to-noise ratio levels at 7 T compared to lower field. Optimal performance might be achieved using purpose designed RF coil arrays. In this study, we introduce an 8-channel dipole array and investigate, using simulations, its RF performances for neonatal application...
Article
Full-text available
We present a combination of a CNN-based encoder with an analytical forward map for solving inverse problems. We call it an encoder-analytic (EA) hybrid model. It does not require a dedicated training dataset and can train itself from the connected forward map in a direct learning fashion. A separate regularization term is not required either, since...
Article
Full-text available
As low-field MRI technology is being disseminated into clinical settings around the world, it is important to assess the image quality required to properly diagnose and treat a given disease and evaluate the role of machine learning algorithms, such as deep learning, in the enhancement of lower quality images. In this post-hoc analysis of an ongoin...
Article
Full-text available
Enhanced activity of the glutamatergic system has been linked to migraine pathophysiology. The present study aimed to assess the involvement of the glutamatergic system in the onset of attacks. We provoked attacks by infusion of glyceryl trinitrate (GTN; 0.5 µg/kg/min over 20 min) in 24 female episodic migraineurs without aura and 13 female age-mat...
Article
Full-text available
Purpose To employ an off‐resonance saturation method to measure the mineral‐iron pool in the postmortem brain, which is an endogenous contrast agent that can give information on cellular iron status. Methods An off‐resonance saturation acquisition protocol was implemented on a 7 Tesla preclinical scanner, and the contrast maps were fitted to an es...
Article
Full-text available
Objective: To visualize the encoding capability of magnetic resonance fingerprinting (MRF) dictionaries. Materials and methods: High-dimensional MRF dictionaries were simulated and embedded into a lower-dimensional space using t-distributed stochastic neighbor embedding (t-SNE). The embeddings were visualized via colors as a surrogate for locati...
Article
Full-text available
Study design: This was a survey of the surgeon members of the Lumbar Spine Research Society (LSRS). Objective: The purpose of this study was to assess trends in surgical practice and patient management involving elective and emergency surgery in the early months of the coronavirus pandemic. Summary of background data: The novel coronavirus has...
Article
Full-text available
Purpose Low‐field (B0 < 0.1 T) MRI has generated much interest as a means of increased accessibility via reduced cost and improved portability compared to conventional clinical systems (B0 ≥ 1.5 Tesla). Here we measure MR relaxation times at 50 mT and compare results with commonly used models based on both in vivo and ex vivo measurements. Methods...
Article
The ability to control the electromagnetic near field with metasurfaces offers potential applications over the frequency range from radio frequency to optical domains. In this work, we show an essential feature of metasurfaces, subwavelength field confinement via excitation of a large number of eigenstates in a narrow frequency range, and demonstra...
Article
Full-text available
Introduction/Aim Duchenne and Becker muscular dystrophies (DMD, BMD) are characterized by fat replacement of different skeletal muscles in a specific temporal order. Given the structural role of dystrophin in skeletal muscle mechanics, muscle architecture could be important in the progressive pathophysiology of muscle degeneration. Therefore, the a...
Preprint
Full-text available
As low-field MRI technology is being disseminated into clinical settings, it is important to assess the image quality required to properly diagnose and treat a given disease. In this post-hoc analysis of an ongoing randomized clinical trial, we assessed the diagnostic utility of reduced-quality and deep learning enhanced images for hydrocephalus tr...
Article
Full-text available
Low-field permanent magnet-based MRI systems are finding increasing use in portable, sustainable and point-of-care applications. In order to maximize performance while minimizing cost many components of such a system should ideally be designed specifically for low frequency operation. In this paper we describe recent developments in constructing an...
Article
Full-text available
Three-dimensional contrast source inversion-electrical properties tomography (3-D CSI-EPT) is an iterative reconstruction method that estimates the electrical properties of tissue from transmit field magnetic resonance data. However, in order to bring 3-D CSI-EPT into practice for complex tissue structures and to understand the origin and effect of...