Ana Pequenín

Ana Pequenín
  • University of Alicante

About

9
Publications
1,597
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
92
Citations
Introduction
Skills and Expertise
Current institution
University of Alicante

Publications

Publications (9)
Article
Experimental isobaric vapor–liquid–liquid and vapor–liquid equilibrium (VLLE and VLE) data for the ternary system water (1)–hexane (2)–toluene (3) and the quaternary system water (1)–ethanol (2)–hexane (3)–toluene (4) were measured at 101.3 kPa. An all-glass, dynamic recirculating still equipped with an ultrasonic homogenizer was used to determine...
Article
Full-text available
Experimental isobaric vapor–liquid–liquid and vapor–liquid equilibrium data for the ternary system water (1)–cyclohexane (2)–toluene (3) and the quaternary system water (1)–ethanol (2)–cyclohexane (3)–toluene (4) were measured at 101.3kPa. An all-glass, dynamic recirculating still equipped with an ultrasonic homogenizer was used to determine the VL...
Article
Full-text available
Experimental isobaric (vapor + liquid + liquid) and (vapor + liquid) equilibrium data for the ternary system {water (1) + cyclohexane (2) + heptane (3)} and the quaternary system {water (1) + ethanol (2) + cyclohexane (3) + heptane (4)} were measured at 101.3 kPa. An all-glass, dynamic recirculating still equipped with an ultrasonic homogenizer was...
Article
An overview of the multicomponent systems for which isobaric (vapor + liquid + liquid) equilibrium (VLLE) data has been published, is presented. This overview comprises 36 ternary and three quaternary systems. For each one of these systems is specified a reference, pressure range, experimental method and the amount of equilibrium data determined. T...
Article
Experimental isobaric vapor-liquid-liquid and vapor-liquid equilibrium data for the ternary system water (1) -cyclohexane (2) -isooctane (3) and the quaternary system wafer (1) -ethanol (2) -cyclohexane (3) -isooctane (4) were measured at 101.3 kPa. An all-glass, dynamic recirculating still equipped with an ultrasonic homogenizer was used to determ...
Article
Full-text available
Emission factors of carbon oxides, light hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), polychlorodibenzodioxin/furans (PCDD/Fs), and dioxin-like polychlorinated biphenyls (PCBs) were determined in the combustion of a mixture of pine needles and cones in a residential stove. Furthermore, several combustion experiments were carried out in a...
Article
In an initial effort to minimize some of the uncertainty regarding the open burning of biomass, emission factors of carbon oxides, light hydrocarbons, PAHs, PCDD/Fs and dioxin-like PCBs were determined in the combustion of tomato plant in a residential stove and in two runs at 500 degrees C and 850 degrees C in a laboratory scale reactor. In all th...
Article
An all-glass, dynamic recirculating still equipped with an ultrasonic homogenizer has been used to determine vapor–liquid (VLE) and vapor–liquid–liquid (VLLE) equilibria. Consistent data have been obtained for the ternary water+ethanol+p-xylene system at 101.3kPa for temperatures in the range of 351.16–365.40K. Experimental results have been used t...

Network

Cited By