Adam HamiltonUniversity of Western Australia | UWA · Division of Oral Rehabilitative Sciences
Adam Hamilton
BDSc, DCD
About
41
Publications
35,176
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
730
Citations
Introduction
Skills and Expertise
Publications
Publications (41)
Introduction
Using mini implants as transitional implants (TIs) for complete arch implant‐supported rehabilitations may overcome limitations associated with mucosa‐supported surgical guides and facilitate immediate fixed provisionalization. This study aimed to assess the success of TIs in supporting surgical guides for implant placement and fixed p...
Objective
This study aims to present the bio‐restorative approach in implant dentistry, which combines biological and restorative concepts through digital planning. This concept combines periodontal, surgical, and prosthetic variables, aiming to reduce patient morbidity while achieving satisfactory esthetic and functional outcomes in implant‐suppor...
Computer-assisted implant planning allows for a comprehensive treatment plan by combining radiographic data provided by a Cone Beam Computed Tomography (CBCT) with surface optical scan (IOs) data that includes patient intraoral situation and the intended restorative planning. Integrating a tailored restorative design with the patient's anatomical c...
Digital implant planning, utilizing the convergence of digital surface scanners, cone beam computer tomography (CBCT) scans, and advanced planning software, has transformed dental implantology. The merging of these data sets through triangulation of landmarks provides a detailed digital model of the jaws, facilitating precise implant positioning in...
Background
For over three decades, digital technologies have been used in Implant Dentistry, beginning with the introduction of planning software for Static Computer‐Assisted Implant Surgery (S‐CAIS). During this time, this field has witnessed the emergence of diverse methodologies and a proliferation of technological advancements. Today, S‐CAIS is...
Objective
This in‐vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches.
Methods
Twenty‐two abutment‐level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning...
Introduction:
The interforaminal region is considered more favorable for implant placement than the posterior mandible in edentulous patients, mainly because of the interference of the inferior alveolar nerve with implant placement in the severely resorbed posterior mandible. However, complications in the interforaminal region may occur due to the...
Objective
To provide technical and clinical recommendations for implementing a digital workflow in Static Computer‐Aided Implant Surgery in the anterior maxilla.
Clinical Considerations
An optimal 3D implant position is crucial for achieving satisfying results in implant rehabilitation in the esthetic area. Due to its complexity, implant placement...
Objectives: The aim of this study was to assess the following PIO question: In adult patients treated with an indication for single tooth extraction in the maxillary esthetic zone (15-25), what is the influence of an immediate implant placement and immediate loading protocol on the clinical performance (primary aim) and esthetic outcomes (secondary...
Objectives
The aim of this study was to assess the following PIO question: In adult patients treated with an indication for single tooth extraction in the maxillary esthetic zone (15–25), what is the influence of an immediate implant placement and immediate loading protocol on the clinical performance (primary aim) and esthetic outcomes (secondary...
Objectives
The aim of this study was to review available evidence for Type 1A (immediate implant placement and immediate loading) of single tooth replacement in the maxillary esthetic zone.
Materials and Methods
An electronic search was conducted utilizing the databases of MEDLINE, Embase, and Cochrane to identify publications reporting on the out...
Objectives
Working Group 5 was convened to discuss and find consensus on the topics of implant placement and loading protocols associated with single missing teeth in the anterior maxilla (aesthetic zone). Consensus statements, clinical recommendations, patient perspectives and future research suggestions were developed and presented to the plenary...
Objective:
To describe a strategy using digital technologies for improving the diagnosis, treatment planning, and surgical execution of patients with excessive gingival display (EGD) due to altered passive eruption (APE).
Clinical considerations:
An important component for successful patient's management is to fulfill their esthetic expectations...
Removal of cement-retained complete arch implant-supported zirconia restorations can be challenging. A predictable and minimally invasive technique combining cone beam computed tomography (CBCT) and intraoral scans with a virtual implant planning software program is described to identify the location of the screw access channels during the retrieva...
Objective:
This study aims to report the implant survival rate of dental implants of partially dentate patients in the anterior mandible and the potential risk indicators for implant failure.
Material & methods:
Patients with implant supported restorations of single or multiple teeth in the anterior mandible restored with fixed partial implant s...
Over the past decade, emerging evidence indicates a strong relationship between prosthetic design and peri‐implant tissue health. The objective of this narrative review was to evaluate the evidence for the corresponding implant prosthodontic design factors on the risk to peri‐implant tissue health. One of the most important factors to achieve an ac...
Objectives:
Registration of intra-oral surface scans to cone beam computer tomography (CBCT) is critical in the digital workflow for static computer-aided implant surgery (sCAIS). This study aimed to assess the impact of CBCT field of view (FoV) on the precision of digital intra-oral scan registration.
Materials and methods:
CBCT data and intra-...
This case report describes a new digital workflow for computer-assisted implant surgery in an edentulous patient using transitional implants to support a fixed surgical template and interim prosthesis. The accuracy of the final implant position using the described protocol was evaluated and compared to the outcomes obtained using other types of sur...
Purpose:
This study aimed to assess the influence of implant diameter and taper on the proximity of virtually planned maxillary central incisor implants to the nasopalatine canal and adjacent anatomical structures.
Materials and methods:
Virtual implant planning was performed in the maxillary central incisor position. The distance between the im...
A method for the digital articulation of complete arch digital implant scans using the implant abutment prosthetic interfaces is described. This technique provides an effective and efficient method for articulating digital scans without the need for matching soft tissue references or fiduciary markers. This allows for a streamlined workflow with fe...
Static computer assisted implant surgery (s‐CAIS) is an integral part of the digital workflow in implant dentistry and provides the link between the virtual planning environment and surgical field. The accuracy of s‐CAIS is influenced by many cumulative factors including the fit of the template which is related to the manufacturing process. This cr...
Purpose:
To review the factors that affect the ability to deliver a CAD/CAM implant-supported provisional restoration designed from a virtually planned implant position prior to surgical placement with static computer-assisted implant surgery (sCAIS).
Materials and methods:
Data were collected on patients treated with single-tooth implant treatm...
Objectives
This study aimed to determine whether distally angulating an implant is a successful strategy to avoid the maxillary sinus and the need for bone augmentation, while increasing the anterior-posterior (A-P) implant distribution in the edentulous maxilla.
Materials and Methods
In 115 patients with edentulous maxillae, virtual implant plann...
A method is described for the verification and correction of a digital scan of a complete-arch implant-supported prosthesis for a completely edentulous patient. The technique provides an efficient way to integrate a highly accurate and precise scan of an implant index cast with a digital intraoral implant scan by using a computer-aided design and c...
Purpose:
To analyze the effect of implant placement and loading protocols (protocol types) on the survival of single implant tooth replacements in different locations.
Materials and methods:
An electronic search was conducted to identify clinical trials regarding outcomes of single implants subjected to different treatment protocols. A weighted...
Sinus floor elevation with the lateral window approach has proven to be an effective treatment modality for vertical bone augmentation in the posterior region of the maxilla. The simultaneous implant placement during the procedure can be achieved if enough remaining bone height is available to obtain implant primary stability. However, the proper i...
This clinical report describes a completely digital workflow for the rehabilitation of the maxillary and mandibular arches with implant-supported fixed interim prostheses. Computer-assisted implant planning was used to fabricate a multifunctional surgical template for the guided placement of transitional and endosteal dental implants. Advantages of...
Statement of problem
The fit of a 3D printed surgical template will directly influence the accuracy of guided implant surgery. Various 3D printing technologies are currently available with different levels of resolution and printing accuracy; however, how the different systems affect accuracy is unclear.
Purpose
The purpose of this in vitro study...
A method for creating a complete-arch digital trial tooth arrangement for completely edentulous patients is described. The technique demonstrates an effective way to reproduce the dental and gingival anatomies by using a free 3D modeling software program. This cost-effective, time-saving, and versatile method allows dental professionals to digitall...
This case report describes a digital workflow for a computer-aided design/computer-assisted manufacturing (CAD/CAM) healing abutment used in immediate implant placement in the esthetic zone. The design of the healing abutment was based on the existing tooth anatomy in order to provide anatomical support to the gingival tissues and to preserve the g...
Block anesthesia for the maxillary division (V2) of the trigeminal nerve is a suitable approach when an entire quadrant of teeth and/or associated structures are involved. The most effective approach to anesthetize the maxillary branch is intraorally via the greater palatine canal. This case report describes the use of a computer-aided design/compu...
A procedure is described for fabricating a removable resilient soft-tissue replica that accurately replicates the contoured emergence profile of an interim implant-supported restoration on a cast fabricated by 3D printing. The technique uses digital scanning and 3D printing technologies to
produce a 3D printed replica of the implant-supported inter...
A procedure for registering digital intraoral surface scans onto cone beam computed tomography in the presence of significant scatter artifact is described. The technique uses chairside-fabricated composite resin markers placed on well-distributed teeth to serve as common landmarks in each digital data set for accurate registration. This straightfo...
Objectives:
Cone beam CT (CBCT) machines do not always allow for patients to be scanned in the ideal position for image acquisition. This study aimed to investigate the influence of the position/angulation of the mandible relative to the X-ray beam of a CBCT machine.
Methods:
Five sequential CBCT scans were captured of a human mandible at each a...
Objectives
To systematically review the evidence for the clinical outcome of fixed implant prostheses treated with different combinations of implant placement and loading protocols in partially edentulous patients.
Materials and methods
An electronic search was performed in Medline, Embase, and Central to identify studies investigating the outcome...
Objectives
Working Group 2 was convened to address topics relevant to prosthodontics and dental implants. Systematic reviews were developed according to focused questions addressing (a) the number of implants required to support fixed full‐arch restorations, (b) the influence of intentionally tilted implants compared to axial positioned implants wh...
Purpose:
This in vitro study aimed to evaluate the accuracy of surgical templates fabricated using three different 3D printing technologies.
Materials and methods:
Ten identical surgical templates were printed using four 3D printers (two of an identical make and model). Each of the surgical templates was scanned by a reference scanner and then i...
Purpose:
This study aimed to compare the fit of computer-aided design/computerassisted manufacture (CAD/CAM) abutments provided by a single system with proprietary prefabricated abutments on various implant systems.
Materials and methods:
Titanium CAD/CAM abutments were compared with prefabricated abutments on five different implant types. The s...